GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY

Similar documents
INSTALLATION INSTRUCTIONS GB/IE

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

BLACK KNIGHT 2 - Classic Collection

MODEL 466 Radiant / Convector Gas Fire Black Beauty

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

Stockton 7 & 8 Inset Convector Stove

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

Baxi Solaire Super Gas Fire Natural Gas Comp N o /95

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

Model Apex Falcon, Titan & Zenit

CF1 L GAS APPLIANCE THE CONNELLY COLLECTON INSET CONVENTIONAL FLUED GAS FIRE

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner

VASKA C11. gas -fireplace installation guide

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS

Baxi Ebony Super Gas Fire Comp N o Issue 4 10/99

THESE INSTRUCTIONS TO BE LEFT WITH THE END USER

COAL EFFECT BALANCED FLUE GAS FIRE

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

JEWEL HOLE IN THE WALL Horizon trim version

Castelle INSET FUEL EFFECT GAS FIRE. Hand these instructions to the user following installation

Installation & Service Instructions

ENIGMA II SLIMLINE. Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

Passion CONVENTIONAL FLUE LOG EFFECT GAS FIRE

Full Depth Convector MC / SC

Dovre 250 Cast Iron Gas Stove

Installation & Servicing Instructions. To be left with the user MELODY BBU. Fire Front GC No

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

VASKA B11. gas -fireplace installation guide

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

ENIGMA II SLIDE CONTROL Owner's Book

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

installation and user instructions

Windsor HE HIGH EFFICIENCY FUEL EFFECT GAS FIRE

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE

CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE

Chimney Renovation Kit

Integra Convector Plus Manual

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Plus Model BR645 VA (G.C )

Commissioning of Heat Producing Appliances Burning Solid Fuel

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Melody Calypso PC COAL EFFECT GAS FIRE. Installation and Maintenance Instructions

Model 348 Brava RADIANT / CONVECTOR GAS FIRE

INSET LIVE FUEL EFFECT GAS FIRE

Osprey 2 CFL

C&J DGT5000 Suite Shelf or Slab Burner. Owner's Book

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLATION, USERS AND SERVICING INSTRUCTIONS

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

Clear Installation guide

FIRECHARM LF ELECTRONIC

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

INSTALLER S GUIDE. Model BG C-2. (GC No ) INSET LIVE FUEL EFFECT GAS FIRE. (Manufacturer ref. BR658VA)

Do not use this vent pipe or fittings for venting incinerators of any kind.

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

Decorative Fuel Effect Appliances

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

INSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE

Torch framed Installation Guide

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

PARAGON 2000 Xtra SLIDE CONTROL Owner's Book

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

Duet XL /0929. Installation guide

Model 347. Firelite 4 Oxysafe Regency 4 Oxysafe INSTALLER GUIDE. INSTALLER: Please leave this guide with the owner RADIANT / CONVECTOR GAS FIRE

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

installation and user instructions

INSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

INSTALLATION & USER INSTRUCTIONS

Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE

SLIMLINE RADIANT GAS FIRE

PARAGON SYMPHONY CF OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLER AND OWNER GUIDE

Sonnet Plus Anthem Genesis Soraya

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Conventional Flue. Instructions for Installation. For use in NZ (New Zealand). IMPORTANT

ATHENA R.S. LPG. Room Sealed Inset Live Fuel Effect Gas Fire. PRODUCT No. A99011 G.C. No Installation and Servicing Instructions

Hestia Installation Guide

Sonnet Plus Anthem Genesis Soraya

ENIGMA HE Remote Control

INSTALLATION & OPERATING MANUAL

Studio. Built-In Convector. Instructions for Use, Installation & Servicing. For use in AU (Australia)

INSTALLATION AND OWNER GUIDE

THE HOTBOX H.E. Heater Suitable For Natural Gas at Inlet Pressure 20mbar or Propane at Inlet Pressure 37mbar

Kalahari RC & Camber RC

Baxi Bermuda SL3. Fireside Gas Central Heating Unit Comp No Issue 4 1/00. Installation and Servicing Instructions

Apex. Model Options Liberty 6 & 10. Information & Installation Guide

L23 BLACK P23 CONTEMPORARY GLASS

Broadway, Valor Landscape 2 Gas or Vermont fascia

Transcription:

INSTALLATION INSTRUCTIONS GB/IE GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY DRU VERWARMING B.V. HOLLAND 957.669.00

CONTENTS Site: 3 Important 3 Foreword 4 Instructions for installation 4 Ventilation 4 Chimney and Flue System 4 Preparing the appliance for installation 5 Checking the Class 1 Chimney s Performance Prior to Building the Builders Opening 5 Builders Opening Requirements 6 Preparing the Convection Box for Installation into the Builders Opening 6 Using a Flue Liner 7 Fitting into a Conventional Class1 Chimney 7 Connecting the Appliance 8 Spillage Test 10 Figures 2

Important These installation instructions are supplementary to the Installation Manual and User Manual; especially to paragraph 6.4 and 6.5 of the Installation manual. The Concise installation guide also applies. Gas Safety Regulations (for Installation and Use) 1998. In your own interest and that of Safety, it is Law that all Gas Appliances are Installed by Competent Persons in Accordance with the above Regulations. Failure to do so could result in prosecution. CORGI-The Council of Registered Gas Installers, whose Members are Identified by the CORGI Emblem are all required to work to these Recognised Regulations. Foreword Dear Customer, In this booklet you will find instructions for the Installation of the appliance in a builder s opening/fireplace connected to an existing chimney (class 1 chimney). Please read the Installation manual and these Instructions carefully to familiarize you with the Appliance. If you require any further support, please do not hesitate to contact your supplier. The Installation must also be in accordance with all relevant parts of the Local and National Building Regulations where appropriate, the Building Regulations (Scotland Consolidation) issued by the Scottish Development Department, and all applicable requirements of the following British Standards and Codes of Practice. - BS 6891,Installation of Gas Pipe work - BS 5440, Parts 1 & 2 Installation of Flues and Ventilation - BS 1251, Open Fire Place Components - BS 715, Metal Flue Pipe for Gas Appliances - BS 6461, Part 1 Installation of Chimneys and Flues. - BS 7977-1, Specification for safety and rational use of energy of domestic gas appliances. Radiant/convectors English 3 Fitting into a Conventional Class1 Chimney

INSTRUCTIONS FOR INSTALLATION Caution - This fire is fitted with an Oxygen Sensing Pilot that will cut the fire off if the fire is not working Safely. This normally indicates a Chimney, Flue or Ventilation Problem. If this problem is experienced with the fire seek expert advice. - If this fire cuts off within 2 minutes of being lit it is quite likely that the flue or Chimney is Blocked. Ventilation The Global 40 CF is a open-flued appliances. As a result, the room in which the appliance will be placed has to be ventilated sufficiently. Observe the applicable (installation) regulations. If the Chimney is clear yet the fire fails the spillage smoke match test then check for a lack of Adequate Ventilation. A quick check is to slightly open a door or window to see if this corrects the spillage smoke match problem, this will indicate the need for additional purpose provided ventilation, seek expert advise before proceeding. Chimney and Flue System The Fire can be installed into the following: - A traditional Class One 9 by 9 chimney with a minimum effective height of at least 3 meters. If the Chimney has been previously used, it must be swept. The debris shield shall be assembled. - A chimney lined with a 80mm liner with a minimum effective height of 3 meters. The liner must be connected directly to the spigot on the fire and terminate at the top of the chimney. The chimney should firstly be professionally swept before installing the appliance. The chimney should be fitted with an effective chimney cowl, to ensure a good draught in the chimney to help safe guard against the effects of Down Draught and prevent Birds falling down the Chimney. The type of chimney cowl and the position of the opening must meet any applicable local standards, to ensure it works properly. If the fire is installed in an existing chimney with a chimney kit, there may be a slight loss in heat input. Preparing the appliance for installation The design of this fire is such that the convection box can be completely built-in first, into a Builders Opening / Fireplace (of non-combustible and heat-resistant material) and the Fire itself slid into place afterwards. 4

The construction options are given in the Concise installation guide. Caution - Do not install the appliance in a bathroom or room that contains a bath or shower; - Always install the appliance into a non-combustible and heat-resistant wall; - Place the appliance on supports made of non combustible and heatresistant material; - Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material; - Do not make any changes to the appliance; - Make sure that combustible objects and/or materials have a distance from the appliance of at least 500 mm. Determine the location of the appliance; see fig. 1 for the dimensions of the builder s opening. Determine the construction height of the appliance. Provide a gas connection at the location. For details, see section 6.3 of the Installation manual. Checking the Class 1 Chimney s Performance Prior to Building the Builders Opening Apply a smoke pellet to the base of the chimney. If the smoke is drawn into the chimney, continue and build the builders opening. If there is little to no flow into the chimney, preheat the chimney and repeat the smoke pellet test. If there is still no flow, Seek Expert Advise as the chimney may need attention and it may be necessary to use a flue liner with the Chimney. Builders Opening Requirements (fig. 1) To build the convection box into the fireplace, a rectangular hole or Builders Opening must be made that is between 560mm and 570mm high and between 410mm and 420mm wide. The builders opening should be at least 300 mm deep. Construct the Builders Opening accurately ensuring it is square and level to the front face of the Opening. The front face around the Builders Opening must be flat for at least 30mm to ensure the foam seal fitted to flanges of the convection box forms a seal against the opening. Caution The convection box must be Fully Sealed to the Front of the Builders Opening. Failure to do so will Result in a Spillage Problem. English 5 Fitting into a Conventional Class1 Chimney

It is necessary and good practice to fit a Lintel at the top of the Builders Opening to support the brick work, if in doubt always contact a qualified Builder. Where the Builders Opening already exists and is much larger than required the front opening must be reduced to the sizes shown above with non-combustible and heat-resistant materials. The base of the opening must be level with the bottom of the opening, be flat and square with the front of the opening. Where the fire is to be installed into a wall where wall paper is being considered as a wall covering it is recommended that non-combustible and heat-resistant slips such as slate or marble are fixed and sealed around the builders opening. The slips should be at least 20mm thick and 100mm wide. This will help to reduce wall discolouration. Blown vinyl wall paper or coverings must not be used. If you have newly cemented/ plastered the chimney or have had to carry out any other reconstructions /renovations work, you are advised to wait at least 6 weeks before fitting/ lighting the fire, to allow for the walls, floor and ceiling to dry out completely, otherwise cracking may occur. Cracking of the plaster will occur if not dried out properly. Preparing the convection box for Installation into the Builders Opening Remove the glass pane (see installation manual section 6.8). Store the glass pane on a safe place. Unscrew the two self-tapping screws under the combustion chamber and remove this cover (see fig. 2a) Remove the vermiculite tray (see fig. 2b) Unscrew the 4 self-tapping screws of the burner mounting plate and remove the burner mounting plate plus accessories (see fig. 2c) Unscrew the Allen screws (4x) at both sides of the combustion chamber using the supplied Allen key (see fig. 2d) Take hold of the combustion chamber at both sides and remove it (see fig. 2e) Unscrew the 2 self-tapping screws of the flue spigot and remove the flue spigot. Place the convection box in the builder s opening - at the required height - of non combustible and heat-resistant material.!caution Do not allow the appliance to rest on the lower flange (see fig. 2f). Mark the location of the 3 key bolts see (fig. 2g). Remove the convection box and drill holes at the marked places. 6

Using a Flue Liner If a flue liner is to be used the Debris Shield and Plate will not be required. With the flue liner already fitted into the chimney and whilst refitting the convection box guide the liner through the hole in the top of the convection box and secure/seal it to the flue spigot (see fig. 3). Make a gas supply (see fig. 2h). Place back the convection box and make it level. Attach the convection box, using key bolts and flat washers. Place the flue spigot using the 2 self-tapping screws. Continue by connecting the appliance as described below in paragraph Connecting the appliance. Fitting into a Conventional Class 1 Chimney!Caution The debris shield shall be used. Stick the foam seal on the Slips of the convection box. Place back the convection box and make it level. Attach the convection box, using key bolts and flat washers. Caution - Ensure the foam seal is sealing up against the front face of the builders opening. - The convection box must be fully sealed to the front of the builders opening. Failure to do so will result in a spillage problem. If there are any gaps fill them with a high temperature silicone sealant or a non-combustible sealant such as fire cement. There must be no gaps between the Slips and the wall or convection box. Looking through the hole in the top of the convection box and up into the Chimney, check that there is no obstruction and that no part of Chimney is closer than 50mm to the Debris Shield to ensure the flow of Combustion Products passes unaffected. Place the debris shield and fix it to the inside of the convection box using 4 self-tapping screws (see fig. 4) Place the flue spigot using the 2 selftapping screws. Continue by connecting the appliance as described below in paragraph Connecting the appliance. Connecting the appliance Connect the gas pipe to the appliance, as described below. The gas control can be found below the burnerplate. Connect the flexible gas pipe to the gassupply with an elbow: see fig. 2h. Caution - Avoid kinks in the flexible gas pipe; Place the receiver; for details, see section 7.1 of the Installation manual. Set the communication code between the remote control and the receiver; see paragraph 7.2 of the installation manual. English 7 Fitting into a Conventional Class1 Chimney

Caution Do not ignite the appliance until it is fully installed. Check the connections for gastightness as described in paragraph 8.1 of the installation manual. Check the line-pressure as described in paragraph 8.2 of the installation manual. Place the combustion chamber back in the convection box and fix it at both sides with the Allen screws.!caution - Properly connect the flue spigot to the draft diverter when placing back the combustion chamber; see fig. 2i; Place the burner mounting plate plus accessories back and fix it with the self-tapping screws. Place the glass pane after installing the wood set; see paragraph 6.7 et seq. of the installation manual for further instructions. Spillage Test The spillage test is intended to check the draft in the chimney. The spillage test can only be performed if the appliance is fully installed. Reference should be made to section 4.2 in the User Manual on how to ignite the fire. Perform the test as follows: Close all doors and windows of the room in which the appliance has been placed. Ignite the main burner. Operate at its highest level. Extend a smoke match in order to reach the cap in the back of the appliance: see fig. 5. - If the smoke is drawn into the draught diverter towards the flue this shows the test is succesfull. - If the smoke is not drawn into the draught diverter this shows there is spillage and the fire must not be used until this is rectified. 8

English 9 Fitting into a Conventional Class1 Chimney

10

English 2a 2b 2c 11 Fitting into a Conventional Class1 Chimney

INSTRUCTIONS 2d 2e 2f 12

English 2g 2h 2i 13 Fitting into a Conventional Class1 Chimney

3 4a 14

English 4b 5 15 Fitting into a Conventional Class1 Chimney