Designer & Application Notes. Securtiy Termination. belfuse.com/cinch

Similar documents
M7100 Pressure Transducer

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

P125 High Pressure Sensor

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Open-area Smoke Imaging Detector. Engineering Specification

89BSD Digital Output

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Thermostatic Valve and Trim

Sensepoint XCL Fixed Gas Detector

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

R B10 Series : SMB CARLOCK

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Filabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth

CONSTANT SUCTION UNIT

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Tools. Contents Tools for contacts Han D Tools for contacts Han E Tools for contacts Han C

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

RP SERIES THERMAL PROTECTORS

Tools. Contents Tools for contacts Han D Tools for contacts Han E Tools for contacts Han C

Net Safety ST3 XChem Toxic Gas Sensor

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers

U5300 Industrial Pressure Transducer

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

4TM SERIES COMPRESSOR CONTROL Motor Protector Refrigeration Compressors

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

THE HYTORC WASHER SYSTEM

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

ADPRO PRO Series by Xtralis

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Autocalibration Systems for In Situ Oxygen Analyzers

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

PORTABLE HAND POWER THREADER 1/2-2

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Tools for other contacts Tools for FOC contacts Crimping machine TK-M Crimping machine TC-C

Norminal Sprinkler Temperature Rating

MJTG09 Technical Guide

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Enraf Servo Gauge 854 XTG

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Supervisor Standard Edition

Authentic experience in a powered, secured display.

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

EXTRAORDINARY SOUND DESIGNS FOR EXTRAORDINARY PEOPLE

Audi-Larm Audible Alarm

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Environmental Monitoring Card

RF one-step BNC/TNC connectors for coaxial cable termination

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Temperature controllers TW, TO and TP, Speedy Therm

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Centro-Matic Automated Lubrication Systems System Controls

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

M5200 Industrial Pressure Transducer

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Manual Vane Anemometer PCE-VA 20

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

XYR 6000 SmartCET Wireless Corrosion Monitoring Transmitter

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Safety Photo Beam UL MONITORED DEVICE

F AN-ASPIRATED RADIATION SHIELD

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

OPERATION MANUAL MODEL & ACCELEROMETER

Enraf Servo Gauge 854 ATG

Product Specification

Return loss measurement of fiber optic components

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Incutrol/2 Regulator

TESS WIRELESS SENSOR TAG DEMO V1.1

OPERATION MANUAL MODEL 8102 ACCELEROMETER

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

ACQUITY UPLC HT Column Heater Instructions

Microwave Doppler Sensors Applications. for Komantech

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Wireless Occupancy Sensor:

910 Series Single-point heat-tracing control system

Connector Maintenance

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Service Instruction. Reset of LCU and LCA for VISIONLINE

Chimera Aqua Assembly

Transcription:

Designer & Application Notes Securtiy Termination

Applications Security termination solve the problem of unauthorized or accidental removal of terminations and potential damages to RF or microwave assemblies caused by high levels of reflected signals. 1. Test Equipment Maintains accuracy and repeatability of the measurements and protects the test equipment. 2. Test Laboratories Can be used in calibrated test setups to insure consistency and repeatability of the tests. Figure 1 3. Production Equipment To terminate RF test points not designated to be accessed by users for security and/or equipment protection reasons. Figure 2 4. High Power Equipment Ensuring that the test points are always properly terminated to reduce possibilities of equipment damage due to high levels of reflected signals. Figure 3 Figure 4

Technical Information SMA Male Security Termination Part Number Frequency, GHz Internal Termination VSWR, max. TRM-2443-MS-SMA-02 26.5 TRM-2443-M0-SMA-02 1.3 TRM-2444-MS-SMA-02 18 TRM-2444-M0-SMA-02 1.19 TRM-2444-MS-SMA-02 8 TRM-2444-M0-SMA-02 1.11 Nominal Impedance, Ω 50 Average power, W 0.5* Operating Temp., C -55~125 Material and Finish Application Tool Passivated stainless steel TLS-0017-ST-SMA-02 * at 25 C, derated to 0 W at 125 C Mechanical Dimensions Application Tool Model TLS-0017-ST-SMA-02 Security Termination Model TRM-244x-MS-SMA-02

Product Training Materials (PTM) Security termination performs an electrical function of standard RF termination but can be mechanically removed only with a tool specifically designed for this purpose. Inside of the shell of the security termination is Midwest standard termination model TRM-244x-M0-SMA-02 selected upon the required frequency of operation. Security termination should be applied by hand first to ensure proper threading of the SMA interface. Tool should be used at the end to create a final recommended SMA torque and prevent the security termination from being removed without the tool. Applying the Security Termination Step 1 Apply the security termination by hand until you feel the shell slipping Step 3 Apply the final mating torque using an SMA torque wrench. For brass SMA interfaces 3-5 in-lbs, for stainless steel SMA interfaces 7-10 in-lbs Step 2 Align the security termination tool with the security terminations openings and insert inside of the termination. Continue turning the tool by hand in clockwise direction until the termination is hand tight. Step 4 Security termination is now properly mated, it electrically terminates the port as per its electrical specifications and can only be removed using a proper tool.

Product Training Materials (PTM) Removal of the Security Termination Step 1 Align the security termination tool with the security terminations openings and insert inside of the termination. Using an SMA wrench untighten the part in counter clockwise direction. Step 3 Remove the security termination with your hands and keep in safe location together with the tool. Step 2 Continue turning the tool by hand in counter-clockwise direction until the termination is completely lose. Asia Pacific +86 21 5442 7668 ccs.asia.sales@as.cinch.com Europe, Middle East & Africa +44 (0) 1245 342060 CinchConnectivity@eu.cinch.com North America +1 507.833.8822 ccsorders@us.cinch.com 2018 Cinch Connectivity Solutions an-ccs-mwm-security-termination-app-note 04102018