Detector switch - Dual Tech

Similar documents
Detector switch - Dual Tech SCS

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

SCS motion sensors Surface/wall mounting - PIR

Green Switch HD/HC/HS L/N/NT4658N - AM5658. Technical sheets - Automation MY HOME 1. Front view 8

Controller - 4 x 1-10 V outputs - BUS/KNX

Configuration tool with screen

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

User Manual 120/240/300 Outdoor Motion Detector

11,1 30. Ordering data

, ,

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

LPC3BSP65 & LPC3BDP65

Lighting Management Solutions

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PMCSF6 OCCUPANCY SENSOR

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LPCMPIRM65 & LPCMPIRDSI65

IP65 High Bay Dual Sense Sensor

FR-A180 FR-A360. Occupancy detector. Use

MWS3A-PRM Product Guide

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

UP 258E11 OPTISENS OFFICE

IP65 High Bay Dual Sense Sensor

1. Basic safety information 3 2. Proper use 3

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Integrated PIR detectors

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Ceiling PIR HS presence detector. Product Guide. Overview. Features

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Installation Instructions

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

EWP2WIRELESS MOTION DETECTOR

Installation Guide. Ceiling PIR Detector (311) Features and Connections

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Tebis application software

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

SWITCHLITE MRE SLDM ADJ

Product and Applications Description

Passive infrared ceiling sensor

PIR Occupancy & Motion Sensor

µdim Microwave Sensors User Manual

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Movement-based energy control

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBMHS (standard & slim-line PSU)

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Secure WANDERING INSTALLATION AND USAGE GUIDE

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Installation Instructions

False Ceiling HF Sensors

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Data sheet. Function description. Benefits

Lighting Management Solutions

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

SENSA MRE DDM MR

Detailed operating instructions

Flash 3 times per 3 seconds: Under voltage indication, please

Direct Dim Microwave Presence/Absence Detector

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Analogue Dimming Microwave Presence/Absence Detector

HDCVI PIR Camera User s Manual

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

Detailed operating instructions

Product Specifications

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

18W Round LED Wall/Ceiling Light with Microwave Sensor

Colour Observation System

Movement and presence detectors 10 A. 18 Series. Type Type Type Since 1954, light when you need it

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

LUX Hardwired - Installation Notes

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

EasyAir office sensor advanced grouping SNS200

2. Safety. 4. Function

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

CONTROL YOUR HOME FROM EVERYWHERE

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Transcription:

Page 1. Use.................................... 1 2. Technical characteristics................1 3. Dimensions............................ 2 4. Connection........................... 2 5. Installation........................... 3 6. Operation............................. 3 7. Settings................................ 4 8. Performance.......................... 5 9. Care.................................. 6 10. Standards and approvals.............. 6 11. Troubleshooting...................... 6 0 670 94 0 784 52 0 792 52 5 740 49 5 740 99 1. Use 2. Technical characteristics (continued) This device allows a light source to be controlled automatically through the detection of any presence in the surveillance zone using local controls. Presence sensor with 180 detection angle. Detection type: infrared (PIR) and ultrasound (US) Assembly type: wall flush mounted 2. Technical features 230 V~ 2 2000 W 1000 W 4 1000 VA 8.5 A 110 V~ 3 US Detector / Sensor 6 7 4.3 A 5x(2x36 W) US Detector / Sensor ON - OFF button 10x(2x36 W) LEARN button LED 5 4.3 A LED detection PIR Detector / Sensor Voltage: 100-240 V~ Frequency: 50/60 Hz No-load power consumption: 0.4 W Output via normally open contact connected to the phase Wiring: 2 x 2.5 mm2 Flush-mounting box: 40 mm min. Weight: 60 g Impact resistance: IK04 Penetration by solid and liquid matter: IP20 Usage temperature: - 5 C to + 45 C Storage temperature: - 20 C to + 70 C Number of terminals: 4 Type of terminals: screw Terminal capacity: 2 x 2.5 mm2 Stripping length: 8 mm 1 Light level cell 8 1000 VA 2.1 A 250 VA 9 4.3 A 2.1 A I max. 2A 250 VA 1 - Halogen bulb 6-C ompact fluorescent bulb with built-in electronic ballast 2 - ELV halogen bulb with separate electronic ballast 7-C ompact fluorescent bulb with separate ferromagnetic ballast 3 - ELV halogen bulb with separate ferromagnetic ballast 8 - Compact fluorescent bulb with separate electronic ballast 4 - Fluorescent tube with separate ferromagnetic ballast 9 - LED bulb 5 - ELV fluorescent tube with separate electronic ballast 10 - Contactor Technical data sheet: S000066736EN-1 Updated: Created: 17/12/2012 1/6

3. Dimensions 4. CONNECTION 45 51 4.1 Wiring with auxiliary control: 45 35 100 m max. 4. CONNECTION (continued) 4.2 Wiring for several loads connected in parallel 100 m max. S1 S2 SN L1 L2 LN 4.3 Wiring for a single load connected in parallel 100 m max. S1 S2 SN L Technical data sheet: S000066736EN-1 Updated: Created: 17/12/2012 2/6

5. INSTALLATION 6. OPERATION 5.1 Sensor positioning 6.1 More than one sensor and more than one load Manual ON/Automatic OFF mode Pressing the auxiliary control allows the load to be switched on or off manually. If the control is not pressed, the sensor will cut off the load at the end of the time delay or when the light level threshold has been reached. Auto ON/OFF mode: The load will be switched on and off automatically. Option: It is possible to control the sensor by infrared remote control using: Cat. Nos. 0 882 00/01/20/31/32/33. PIR US Synchronising the products is done in two stages: - one long press () all the sensors (S) switch to the ON state - one short press all the sensors (S) switch to the OFF state 5.2 Recommended light exposure 1m 2.5 m 2.5 m * 5.3 Positioning ( ) 2 * ( ) 1 + * Not supplied Updated: ( ) Technical data sheet: S000066736EN-1 Created: 17/12/2012 3/6

6. OPERATION (continued) 7. Settings 6.2 Several sensors connected to a single load 7.1 Detection parameters Sensor parameters L OFF Time delay L OFF Modes Inactive Walk-through mode Inactive Active Manual on/auto off <1 s + L OFF PIR and US PIR and/or US, PIR, US Maintain PIR or US PIR and/or US, PIR, US Restart PIR or US PIR and/or US, PIR, US, Inactive Initial Time delay: Length of time the load is on after detection. PIR Low, medium, (very high)/ high, very high US (high) Auto on/auto off Alarm 0-59 min 59 s Detection system 15 mins 3, 5, 10, 15, 20 min Configuration tools 0 882 30 0 882 35 Modifiable parameters Default value : Detection range setting. Modes: Auto on/auto off mode: Comes on automatically: -A t the detection of a presence if there is an insufficient natural level of light. Turns off automatically: - If no presence is detected and at the end of the time delay set. - Or if the natural light level is sufficient (regulation activated) Another detection causes automatic switch-on if there is insufficient light. Walk-through mode: - If no presence is detected in the 20 seconds following an initial detection, the product will cut off the load after 3 minutes. - I f another presence is detected in the 3 minutes following initial detection, the device will cut off the load at the end of the set time delay. Manual on/auto off mode: Comes on via a manual switch, automatic switch off: - Where no presence is detected and at the end of the time delay set. After switch-off, any new detection within a 30 second period triggers an automatic switch-on. The Restart function must be activated. After 30 seconds the device is switched on via a manual switch. Detection system: Initial detection: The load is switched on as soon as the first detection occurs if the natural light level is below the light level threshold. Maintain: The load remains active if another presence is detected. Restart: In manual mode. After switch-off, any new detection within a 30 second period triggers an automatic switch-on. After 30 seconds the device must be switched on manually. Alarm: an audible signal is emitted before switch-off. (1 minute before, then 30 seconds, then 10 seconds). Technical data sheet: S000066736EN-1 Updated: Created: 17/12/2012 4/6

7. Settings (continued) 7.2 Light parameters 8. Performance Height Sensor parameter Default value Modifiable parameters Configuration tools Light level threshold 300 lux 0 882 30 0 882 35 20, 100, 300, 500, 1000 lux 0-1275 lux 1.2 m m: 4 5 6 8 Advanced mode Calibration 0-99995 lux Regulation Light contribution Active Auto Auto - 1275 lux 6 m (PIR/ US) 3 m (PIR/ US) 90 60 30 0 light level threshold: Value at which the load comes on if the natural light level is less than the setting. Caution: The device becomes a motion detector at 1275 lux. Advanced mode: calibration: The surrounding light level measured with a luxmeter must then be transmitted to the sensor (see data sheet Cat. No. 0 882 30) regulation: Automatic switch-off of the load 10 minutes after the light level threshold is exceeded with an additional safety threshold (to avoid lights switching off at the wrong moment). Light contribution: Quantity of additional lux provided by the load being switched on. When the light contribution parameter is set to "Auto" (value 0) on the configuration tool Cat. No. 0 882 30 the sensor automatically calculates the light contribution. 7.3 Modifying the parameters using the configuration tools 5 m (PIR/US) 8 m (PIR/US) 8.1 PIR detection (Walk-through) Ø (m) Low (25%) 7 Medium (50%) 8 High (75%) 10 Very high (100%) 12 8.2 US detection (Walk-through) 0 (m) 30 (m) 60 (m) 90 (m) Low (25%) Medium (50%) 6 6 6 2 High (75%) 7 7 6 2 Very high (100%) 8 8 7 3 8.3 PIR + US detection (Presence) Side test: m Low (25%) 1 Medium (50%) 1 High (75%) 2 Very high (100%) 5 0 882 35: Simplified configuration tool 0 882 30: Advanced configuration tool When the sensor receives an IR command using the configuration tool it emits a beep acknowledging the modification. For more information about setting parameters, refer to the data sheet for the configuration tool Cat. No. 0 882 30. Range: 1 m. - restore to factory settings: 1 st press: Short press on LEARN: the LED flashes slowly. 2 nd press: Press and hold down LEARN for 10 seconds until the LED flashes quickly. Diagonal then side output test: m Low (25%) 3 Medium (50%) 4 High (75%) 5 Very high (100%) 6 Technical data sheet: S000066736EN-1 Updated: Created: 17/12/2012 5/6

9. Care Keep the lens clean. Clean the surface with a cloth. Do not use acetone, tar-removing cleaning agents or trichloroethylene. Resistant to the following products: - Hexane (EN 60669-1) - Methylated spirit - Soapy water - Diluted ammonia - Bleach diluted to 10% - Window-cleaning products. Caution: Always test before using other special cleaning products. 10. Standards Directive: CE Installation standards: NFC 15-100 Product standards: IEC 60669-2-1 Environmental standards: - European Directive 2002/96/EC: WEEE (Waste Electrical and Electronic Equipment). - European Directive 2002/95/EC: RoHS (Restriction of Hazardous Substances). - Decrees and/or regulations: ERP (public buildings) ERT (workplace buildings) IGH (high-rise buildings) 11. Troubleshooting Problem Causes Solutions Lighting stays on when there is no-one present Lighting does not switch off during the day when there is an adequate level of natural light Lighting switches off when there are people present and the natural light level is not adequate (darkness) Sources of interference can cause false tripping, such as: air current, vibrations, radiators Regulation function not active Light level threshold set too high Light contribution is too high Time delay too short Detection sensitivity too low Light level threshold too low 1- Reduce the sensitivity level 2- If the interference continues: using the configuration tool, go into the Detection system parameters, select Maintain and then choose PIR and US 3- If the interference still continues, move the sensor away from sources of interference Activate the regulation function Reduce the light level threshold Check that the sensor is positioned correctly in relation to the window Decrease the power of the luminaires Increase the time delay 10 to 1 minutes is recommended for work areas Increase the sensitivity Move the sensor closer to the work area Increase the threshold Technical data sheet: S000066736EN-1 Updated: Created: 17/12/2012 6/6