Product data sheet AIRWIN additional modules Accessories AIRWIN

Similar documents
Process Alarm Module RTA 421

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Key benefits. Why Condair CP3?

02/11/2015

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Temperature Controllers

Gas Controller Module GC-06

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Lift Station Level Controller

02/11/2015

KMF Environmental test chamber for constant climate

General Specifications

Multi-Gas-Controller MGC2

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Condair Mk5. Getting rid of scale. The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy

On the job around the clock 24/7: Fire detection systems

Model D12-IR. Digital Gas Transmitter...

LC1350 Level Controller

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Alarm Modules Section E

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

DGC-1000 DIGITAL GENSET CONTROLLER

Constant climate chambers

Constant climate chambers

Series Temperature Controller Instruction Sheet

Plant growth chambers

Danfoss gas detection Controller unit

DGC-500 DIGITAL GENSET CONTROLLER

Turbimax CUE21 / CUE22

/8 DIN Level Indicator

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

HTC-915-CONT. Heat-Trace Control system

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Heating controller Lago

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

INSTALLATION & USER MANUAL

Two-Channel Gas Controller

Remote alarm indicator and test combination MK2430

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Constant climate chambers

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

FUNCTIONAL SAFETY MANUAL

Constant climate chamber with ICH-compliant illumination

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Duct and Rough Service Carbon Monoxide Sensor

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Environmental simulation chamber for complex alternating climate profiles

Constant climate chambers

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Constant climate chambers

Dew point set DS 400

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

Danfoss gas detection units

PRELIMINARY EDITION

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

I/A Series 716C 1/16 DIN Temperature Controller

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Instrumentation Products and Applications

Universal fault annunciator for panel mounting

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Nov 08 PRODUCT SPECIFICATION SHEET

UDC 700 Universal Digital Controllers and Indicator Specifications

Multiview Monitor / Controller

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Fire control panel detect 3004 plus and accessories

Ionisation single-tube smoke detector for duct mounting

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

Constant climate chamber with humidity

ECL Comfort V a.c. and 24 V a.c.

561-MB256 plus. Intruder alarm control panel. Performance features

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Series Digital Controller Instruction Sheet

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Transcription:

Product data sheet AIRWIN additional modules Ozone module Item no. 2002004 Hygiene fresh produce humidification UB-12/18/24 Fan module KMB Item no. 2002003 Airflow AquaDrain module Item no. 2002001 Hygiene management AquaDrain KMB BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching, limit comparators, program start, status signal BO-CT1 Option board analog input 2 Item no. 0002213 external setpoint setting BO-CT1 Option board interface RS422/485 Item no. 0002214 Communication GLT, modbus

Product data sheet AIRWIN additional modules BO-CSA-6 Isolation amplifier Item no 6100114 Control signal amplifier

Product data sheet AIRWIN Ozone module The Ozone module is a product of the AIRWIN brand of. It may be integrated in universal air humidifiers of the UB-12/18/24 series. The use of ozone for hygienic purposes plays an important role in the humidification of fresh produce such as fruit and vegetables. It consists of a power pack and two ozone generators that are built into the humidifiers in a flowoptimized way. The dimensioning follows the maximum workplace concentrations. The ozone module is supplied only as an installed component in connection with one of the above-mentioned universal air humidifiers, or is retrofit in our factory in existing humidifiers. Power supply with two ozone generators Integrated in UB-12/18/24 For the ozonisation of the aerosol distribution system Protection of fresh produce Max. power consumption 2.88VA Max. ozone generation 60 mg/h Operating voltage of ozone generator 12 VDC Ozone generator - height x width x depth 34 x 85 x 34 mm Power supply - height x width x depth 36 x 98 x 112 mm Weight 0.55 kg Power supply 48 / 50 V / Hz Ambient temperature 5...45 C 2 ozone generators Power pack Ozone module Item No. 2002004

Product data sheet AIRWIN Fan Module KMB Humidifier for minimum quantities The fan module is a product of the AIRWIN brand of. It belongs to the optional accessories of the humidifier for minimum quantities KMB. If the KMB cannot be operated with an available air flow, the supporting air flow that transports the aerosols out of the KMB is missing. The fan module KMB is ready to plug-in and can be placed on the KMB. The integrated fan generates the supporting air flow. The humdification output can also be controlled either via the potentiometer in the fan module or via control signal 0-10 V. Housing made of demineralised water-resistant stainless steel Easy connection of the fan module to the KMB Easy replacement of the air filter mat The humidification output is set via potentiometer Max. air volume flow 13 m³/h Power consumption 0.8 VA height x width x depth 73 x 107 x 50 mm Weight 0.34 kg Power supply 24 VDC Ambient temperature 5...45 C Fan module KMB Installation and operating instructions Connection cable for fan module KMB Spacers for mounting Fan module KMB Item No. 2002003

Product data sheet AIRWIN AquaDrain Module Humidifier for minimum quantities The AquaDrain Module is a product of the AIRWIN brand of. It is used as an accessory for the humidifier for minimum quantities KMB with the hygiene management AquaDrain. Via the built-in week timer, the drainage cycle can be freely preset. Splash-proof plastic housing incl. weekly timer with LCD display Connected magnetic valve with 2 m of cable length Easy connection to the discharge system with hose Ø 8 mm Smallest adjustable time interval 2 s Connection cable AquaDrain Module 0.5 m Power consumption 55 VA Protection class housing IP54 of housing - height x width x depth 175 x 105 x 110 mm Hose connections Ø 8 mm Weight 1 kg Power supply 230 / 50 V / Hz Ambient temperature 5...45 C AquaDrain Module Installation and operating instructions Hose D/d = 8/6 mm (2 m) AquaDrain Module Item No. 2002001

Product data sheet AIRWIN Continuous Controller BO-CT1 The Continuous Controller BO-CT1 is a product of the AIRWIN brand of. It takes over continuous proportional power control of humidifiers with the reference variable relative air humidity, which must be supplied by a humidity sensor. The continuous controller is freely configurable and can be adjusted to the requirements of the customer. Its functionality may be extended with optional modules. Continuous proportional control of up to 5 humidifiers High-contrast multi-color LCD display for actual value, setpoint and operator guidance Operation via four front panel buttons Analogous input for sensor signal, control output for control signal, 2 relay outputs, power supply for external humidity sensor, 2 binary inputs Power supply 110...240 / 48...63 V/Hz Power consumption 13 VA Voltage output sensor 17 / 20 V/mA Relay outputs 230 / 3 V/A Input measuring signal voltage 0 (2)...10 V resistance > 100 kω Input measuring signal power 0 (4)...20 ma resistance < 100 Ω Output control signal voltage 0...10 / 2...10 V / V load resistance 500 Ω Output control signal power 0...20 / 4...20 ma / ma load resistance 500 Ω Protection class front / rear IP 65 / IP 20 Installation dimensions - height x width x depth 57.1 x 99 x 90 mm Panel cut-out - height x width 48 x 96 mm Weight 0.55 kg Ambient temperature 0...55 C Position front panel mounting according to DIN IEC 61554 Continuous controller BO-CT1 Operating manual Seal Fastening elements BO-CT1 continuous controller Item no. 6100101

Product data sheet AIRWIN Extension BO-CT1 Accessories AIRWIN The continuous controller BO CT1 serves as continuous proportional controller for ultrasonic humidifiers of the AIRWIN brand of. The functionality of the controller can be extended by a maximum of two function boards. For this purpose, the optional boards come with 2 binary inputs, analogous input 2 for external setpoint setting and interface RS422/485. Plug-in board for functional extension of the continuous controller BO CT1 Inclusion of up to two additional test boards Optional board with binary inputs to be used for setpoint switch-over, limit comparators, software start, status message Optional board with analogous input to be used as an extension of the input signals, e.g. for external setpoint setting Optional board interface RS422/RS485 for communication between a master and up to 31 slaves Optional board binary inputs Number of binary inputs potential-free 2 Optional board for analogous input Voltage 0(2)...10 V Input resistance voltage > 100 kω Current 0(4). 20 ma Input resistance current < 100 Ω Optional board interface RS422/485 Interface model RS422/RS485 Protocol Modbus, Modbus Integer Baud rate 9600, 19200, 38400 Bd Device address 0...255 Max. number of participants 32 Plug-in board for continuous controller BO-CT1 - height x width x depth 13 x 68 x 21 mm Integration in continuous controller BO CT1 Optional board for use in continuous controller BO CT1 BO-CT1 optional board Use Item no. 2 binary inputs Signal contacts 0002212 Analogous input 2 External setpoint setting 0002213 Interface RS422/485 Communication with BMS 0002214 see chart Item no. see chart

Product data sheet AIRWIN BO-CSA-6 Isolation Amplifier The isolation amplifier BO-CSA-6 is a product of the AIRWIN brand of. It helps to reinforce the proportional control signal 0-10 VDC and can be integrated in the control cabinet SUR/P and SUR/PT. The reinforcement of the control signal by the isolation amplifier allows the proportionate control of up to six humidifiers. By using five isolation amplifiers up to 30 ultrasonic air humidifiers can be controlled. Add-on housing made of PA / V0 Unipolar inputs and outputs 3-way galvanic isolation between input, output and auxiliary voltage Snap-in mounting for standard rail TS35 High reliability Connection with M3 screw terminals 0.14-2.5 mm², rigid or flexible Supply voltage 19.2...30 VDC Power consumption 2 VA Transmission frequency 25 Hz Input control signal voltage 0...10 V Load 100 kω Max overload 50 V Output control signal voltage 0...10 V Current max. 20 ma installation dimensions - height x width x depth 70.4 x 17.5 x 90.5 mm Weight 68 g Ambient temperature 0...50 C Protection IP20 BO-CSA-6 isolation amplifier Installation and operating instructions BO-CSA-6 Item no. 6100114