Inspection Report John Property Address: 1234 Sample Way Sarasota FL 34238 Front View Left View Right View Rear View
Shawn Staggs HI8446 4029 Crockers Lake Blvd Unit 1821 Sarasota, FL 34238 (941) 676-2375 1234 Sample Way Page 2 of 12
Table of Contents Cover Page...1 Table of Contents...3 Intro Page...4 1 Plumbing Systems...5 2 Electrical Systems...7 3 HVAC Systems...9 4 Roofing Systems... 11 1234 Sample Way Page 3 of 12
Date: 12/23/2015 Time: Report ID: Property: 1234 Sample Way Sarasota FL 34238 Customer: John Comment Key or Definitions Real Estate Professional: The following definitions of comment descriptions represent this inspection report. A Four-Point Insurance Inspection is typically performed for a homeowner when requested by their insurance company to obtain a new insurance policy or renewing an existing policy. Latent or unobserved defects may be present. This report does not guarantee the insurability of the inspected property. This is NOT a Home Inspection! (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this home or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. In Attendance: Buyer's Agent Type of building: Single Family (1 story) ISO Classification (Construction): ISO 2 - Joisted Masonry Total Building Square Footage: 1272 Total Under Air Square Footage: 1173 Year Built: 1977 Temperature: Over 65 (F) = 18 (C) Weather: Clear Ground/Soil surface condition: Dry Rain in last 3 days: Yes 1234 Sample Way Page 4 of 12
1. Plumbing Systems Kitchen Plumbing Master Bathroom Plumbing Master Bathroom Plumbing Toilet Connection Washer Connection Water Heater 1234 Sample Way Page 5 of 12
TPR Valve Water Heater Data Plate Styles & Materials Plumbing Water Supply: Copper Plumbing Waste: PVC Water Heater Location: Garage Update Year Of Plumbing System: 2015 Plumbing Water Drain: PVC Water Heater Power Source: Electric Water Heater Manufacture Year: 2015 Estimated Remaining Life Of Plumbing System: 40-45 Years Plumbing Water Vent: Cast Iron Manufacturer: RHEEM Plumbing Updates: Partial Items A. Plumbing Drain, Waste and Vent Systems B. Plumbing Water Supply, Distribution System and Fixtures C. Hot Water Systems, Controls, Chimneys, Flues and Vents 1234 Sample Way Page 6 of 12
2. Electrical Systems Electrical Panel Main Breaker 200A Electrical Panel (Inside) Service Entrance Wiring (Aluminum) Styles & Materials Electrical Service Conductors: Overhead service Aluminum 220 volts Electric Panel Manufacturer: ITE Wiring Updates: Partial Panel capacity: 200 AMP Branch wire 15 and 20 AMP: Copper Update Year Of Electrical System: 2015 Panel Type: Circuit breakers Wiring Methods: Romex Estimated Remaining Life Of Electrical System: 35-40 Years Items A. Service Entrance Conductors 1234 Sample Way Page 7 of 12
B. Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels C. Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage D. Connected Devices and Fixtures E. Location of Main and Distribution Panels 1234 Sample Way Page 8 of 12
3. HVAC Systems Condenser Unit Condenser Unit Data Plate Air Handler Air Handler Data Plate Styles & Materials Heat Type: Heat Pump Forced Air (also provides cool air) Manufactured year of heating system: 2007 Central Air Manufacturer: RHEEM Energy Source: Electric Heat System Brand: RHEEM Manufactured year of cooling system: 2007 Number of Heat Systems (excluding wood): One Cooling Equipment Type: Heat Pump Forced Air (also provides warm air) Items A. Heating Equipment 1234 Sample Way Page 9 of 12
B. Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) C. Cooling and Air Handler Equipment 1234 Sample Way Page 10 of 12
4. Roofing Systems Roof Covering Roof Covering Roof Covering Roof Covering Styles & Materials Roof Covering: 3-Tab fiberglass Age of roof covering (main roof): 11 Years Old Viewed roof covering from: Walked roof Estimated life remaining (main roof): 7-8 Years Number of roof layers: One Items A. Roof Coverings B. Flashings C. Skylights, Chimneys and Roof Penetrations 1234 Sample Way Page 11 of 12
D. Roof Drainage Systems 1234 Sample Way Page 12 of 12