EVA-SCM-SCI Sounder Control Module

Similar documents
Instruction Manual EVA-S6 Base

Instruction Manual EVA-STB-RL

Instruction Manual EVA-PY

Instruction Manual EVA-DPH

FW-RA-LED Remote Multiplex Annunciator Panels

Booster Power Supply Manual

1. POWERPATH Operation

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

SC-6 Six Supervised Control Module

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Figure 1. Figure 2. See notes 1 and 2 below.

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Dimensions of the Optional Mounting Box (BB-400R/W)

FireNET Plus Wiring Instructions

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Touch Screen 1 loop Addressable Fire Alarm Panel

PSN-1000 & PSN 1000(E) Installation Manual

Addressable NAC Output Module D327A

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

* These Remote Mics must be SPRM-GP

CZ-6A Six Zone Interface Module

INSTALLATION INSTRUCTIONS

SIGA-CC1 Single Input Signal Module Installation Sheet

TrueAlert Addressable Notification Appliances

MODEL 5100 BROADBAND ALARM COMMUNICATOR INSTALLATION & USER S GUIDE PRODUCT ID #

Ultrasonic Reflective Sensor

TrueAlert Notification Appliances

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

SECTION FIRE ALARM SYSTEMS

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

TrueAlert Addressable Notification Appliances

Print Specification. Publication. Instructions. Specific requirements. General requirements

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

OPERATION & INSTALLATION MANUAL

Addressable Fire Alarm Control Panel

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

LifeAlarm Fire Alarm Controls

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

ACL TC 200 TEMPERATURE CONTROLLER

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

Installation and Testing of Inverted Bucket Steam Traps Manual

Multiple Input and Output Modules

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

These instructions detail procedures to follow in order to avoid damage to equipment.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

! "! # Please read these installation and operating instructions completely and carefully before starting.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

RAX-LCD-LITE. Remote Annunciator. Installation and Operation Manual

Installation and Operations Manual

Macurco HD-11 Hydrogen Gas Detector

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Nittan SPERA NETWORK FIRE ALARM/ DETECTION SYSTEM SPECIFICATION

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

July 14, 1999 DF C-100.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Signature Series Auto-Sync Output Module (CC1S)

ELECTRONIC SOUNDER STROBE Model : AVD-C407

/5121/5122 TrueAlert Power Supply Installation Instructions

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

External Wireless Sounder

Ultrasonic Reflective Sensor

Preamplifier Power Supply PPS-02 user's guide

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

TrueAlert Addressable Notification Appliances

Model Number Structure

Model pictured: ST6001

Clean Steam Generators

Addressable Detectors & Bases

Remote NAC Power Supply D7038

PAD100-6DB & PAD100-4DB PAD100-PD

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

FMR Installation Instructions. Addressable Fire System Controller

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

RSA2CL6SS model pictured

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

TrueAlert Addressable Notification Appliances

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Transcription:

Instruction Manual EVA-SCM-SCI Sounder Control Module NITTAN COMPANY, LIMITED 1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully and keep for future reference. The information in this document is subject to change without notice. For updates please refer to our website. the module operates NAC devices, and Output LED (red) illuminates. Trouble condition: If an overcurrent occurs because SLC (Signaling Line Circuit) is shorted, SCI LED (yellow) illuminates, and the module communicates to the control panel the short status. The module also communicates to the control panel the open/short status of NAC. SCI (short circuit isolator) Function The module has a built-in short circuit isolator. SCI circuit prevents entire loop failure in the event of a short between L+ and L- on the loop. If a short is detected between L+ and L-, the yellow LED indicator is illuminated. The line between Lin- and Lout- is disconnected automatically to isolate the short circuit, and short circuit status is Note: Follow the requirements for the installation of the product in accordance with the Specifications. Otherwise it may cause malfunction. Note: Do not install the product in any location where oil, dust, iron communicated to the control panel. Upon removal of the short condition, the module will automatically connect between Lin- and Lout- to restore the entire loop to the normal operating status. powder, chemicals, or hydrogen sulphide may occur or affect the product. It may cause malfunction. This package contains the following items: Main unit 1 Outer cover EVA 1 Instruction Manual 1 Output LED (RED) Polling LED (GREEN) SCI LED (YELLOW) Address Setting Port Tapping screw 2 Pan head screw 2 EOL Resister (RE-10k) 1 Figure 1 General Description EVA-SCM-SCI Sounder Control Module with Short Circuit Isolator is an output module intended for use in addressable two wire systems, which provides the control of NAC (Notification Appliance Circuit) devices. The Notification Appliance Circuit can be wired on Class A (Style Z) and Class B (Style Y). General Operation Normal standby condition: The module receives polling from a control panel at the regular interval. Polling LED (green) flashes. Active condition: When receiving a control signal from the control panel, Figure 2 mm(in) 1

Compatibility Requirement To ensure proper operation, the module shall be connected to UL listed control panel NFU-7000 series. Before Installing Disconnect power to the control panel before installing the module. If the module is installed in an existing operational system, inform the Note: All wiring is power-limited and supervised. operators and local authorities that the system will be temporarily out of service. Refer to the following table for listed NAC devices to be connected. Model Name Manufacturer Description Mounting Mount the module directly to 4 square electrical box (UL Listed). Secure the module to the electrical box, as shown in Figure 3. EVCA-AP-H NITTAN Horn EVCA-AP-S NITTAN Strobe EVCA-AP-SH NITTAN Horn & strobe EVCA-AP-SWP NITTAN Waterproof Horn EVCA-AP-SHWP NITTAN Waterproof Horn & strobe The number of NAC devices that can be connected varies depending on settings, but shall not exceed 14 devices. Please refer to the specifications of NAC devices for the consumption current and DIP switch setting. Select the temporal tone in each NAC device for a standard evacuation pattern. Figure 3 Address Setting Use EVA-AD2 Programmer for setting the address of the module prior to installation. EVA-SCM-SCI has an address given at random from factory. Connect the Programmer with the address setting port to change the address to any of 1-254 (dec), with reference to the instruction manual of EVA-AD2 Programmer. The address can be set regardless of whether power supply from the control panel is turned on or off. During setting address, the module does not respond to the control panel. Set the address of module according to Job data. Wiring All wiring must conform to applicable local codes, ordinances, and regulations. Install module wiring in accordance with the appropriate wiring diagrams. 2

Style Z Connect Listed synchronization module EVCA-AP-SMD10 for the synchronization of NAC devices. Style Y EOL (10k ohm) is connected between S+ and S- in EVA-SCM-SCI. Refer to Figure 5 for wiring. Connect Listed synchronization module EVCA-AP-SMD10 for the synchronization of NAC devices. Figure 4 Figure 5 Maintenance Routine inspection: Ensure the module is secure and undamaged. Operation Test The purpose of the Operational Test is to confirm the product s correct operation. 1) When carrying out site testing of the product, the control panel shall be set to one-man-walk test mode prior to the test. 2) Take any necessary precautions to limit the sounding of the alarm sounders/bells and any fire service summoning device. 3) Operate a control signal from the control panel to activate NAC devices, and confirm that the Output LED (red) illuminates. Note: If the test cannot be carried out as terminal wiring is connected, remove the wire connected to NAC, and test between terminal S+ and S-(or R+ and R-)to check the module. (In the active status, 24V is output between S+ and S- (or between R+ and R-). 4) After the module is brought into the active condition, reset the 3

module. It may be necessary to allow a short time to elapse before the module is reset. Confirm that the module goes back to the initial status after the active status is reset. (In the normal status, no voltage is output between S+ and S- (or between R+ and R-). 5) Short between terminal Lin+ (Lout+) and Lin- (Lout-), and the SCI LED (yellow) is illuminated. The short circuit isolator isolates the devices connected after the short-circuited area, which makes these devices have no response. Upon removal of the short condition, the area is automatically connected to go back to the normal standby status, and the SCI LED (yellow) turns off. FOR WARRANTY SERVICE, RETURN TO: OVERSEAS BUSINESS DIVISION, NITTAN COMPANY, LIMITED 1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPAN http://www.nittan.com Specifications Applied Voltage SLC Current Consumption SLC Line Impedance Relay(±I) Number of NAC Circuits NAC Circuit Rating NAC Line Impedance EOL Device SCI on Resistance SCI Fault Detection Threshold SCI Isolation Current Visual Indicator (Status LED) Ambient Installation Temperature SLC Rated Range 20 to 38VDC I± Rated Range 16 to 30VDC Standby 0.8mA Activated 3.6mA Up to 50 ohms Switching capacity DC 30V/2A 1 x Class A or 1 x Class B 16 to 30VDC, 2A (max) Up to 50 ohms RE-10k (10k ohms, 1/4W) Class B only 0.2 ohms (max) 10V (min) 22mA (max) Polling LED (GREEN) Output LED (RED) SCI LED (YELLOW) 0 to 49 (32 F to 120 F) Storage Temperature Max Relative Humidity Environment Maximum quantity per loop -20 to 60 (-4 F to 140 F) Up to 93% RH,non-condensing Indoor dry use only 127 units Terminal Screw AWG12 to 22 Address setting Dimensions EVA-AD2 Address Programmer 124mm H x 124mm W x 34.5mm D (4.882 H x 4.882 W x 1.358 D) (Mount to a 4 square by 2⅛ deep box) Weight Conformity Approximately 167g (5.9oz) UL864 4

Warranties 1.1 Nittan warrants to the customers that: (a) all products supplied hereunder will be of merchantable quality and will comply with any specification agreed between Nittan and customer. (b) it is not aware of any rights of any third party in the market which would or might render the sale of the products, or the use of any of the trade marks on or in products, or the use of any of the trade marks on or in relation to the products, unlawful. 1.2 In the event of any breach of the Nittan's warranty in Clause 1.1(a) whether by reason of defective materials, production faults or otherwise, Nittan's liability shall be limited to: (a) replacement of the products in question; or (b) at the Nittan s option, repayment of the price where this had been paid. And the warranty period is three (3) years from the shipment from Nittan s factory. 1.3 Notwithstanding anything to the contrary in this warranty terms, Nittan shall not be liable to the customer by reason of any representation or implied warranty, condition or other term or any duty at common law, or under the express terms of this warranty terms, for any consequential loss or damage whether for loss of profit or otherwise and whether occasioned by the negligence of Nittan or its employees or agents or otherwise, arising out of or in connection with any act or omission of Nittan relating to Nittan or supply of the products, their use by any customer. 1.4 Customer shall indemnify Nittan against all loss, damages, liabilities, costs and expenses which Nittan may suffer or incur as a result of or in connection with any breach by customer of this warranties terms or any laws or regulations of any jurisdiction or any rules of any governing authorities. 5