Operating Manual Ionizer

Similar documents
Operating manual Electronic Moisture Analyser

Operating Manual Electronic Moisture Analyser

Operating Manual Electronic Moisture meter

Operating manual Electronic Moisture Analyser

KERN MPK Version GB

KERN MGD Version GB

Operating Manual Bathroom Balance

IDEAL IDEAL Modular conveyor belt system. Operating Instructions

KERN MFB Type MGE Version GB

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

Operating Instructions

The CE Marking Access to the European Market

Ionizer (Static Remover) STABLO-EX Instruction Manual

KERN MRS Operating Instructions Moisture Analyzer

DL/DLM. Operating instructions Manuel d instructions Instrucciones de uso

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY

Operating instructions For Vibration level switch. Model NSV

DECLARATION OF CONFORMITY KONFORMITÄTSERKLÄRUNG

Manual OW Caution:

User Manual. WR10-CP-LED 10 W Art.-No.: WR20-CP-LED 20 W Art.-No.: WR30-CP-LED 30 W Art.-No.

Operating Instructions for Liquid Level Transducer Model : MM Series

VACOOK. Thermocirculator for Sous Vide cooking USE AND MAINTENANCE MANUAL

QBx Sub. Powered Subwoofer Owner s Manual

MANUAL. for heat press. Secabo TC2

MULTI-MAX. A) Application - Operating with wheels Do not work without protection cover

Physikalisch-Technische Bundesanstalt

EG KONFORMITÄTSERKLÄRUNG EC DECLARATION AND MANUFACTURER S DECLARATION OF CONFORMITY CE DÉCLARATION DE CONFORMITÉ CE DICHIARAZIONE DI CONFORMITÀ

CTC EcoZenith C 530 l 510

REC LRD0 / LGD0 DE EN FR IT ES NL RU PL LT LV SR CZ RO BG HU

MANUAL. for heat presses. Secabo TC5 and TC7

IONTO-COMED INSTRUCTION MANUAL IONTO-COMFORT XDREAM BED

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

Pizza Oven. Instruction manual. Model: CP868

Instruction Manual Captive Air Level Control. Model NLP

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

Induction Cooker Instruction Manual. Model Modèle Modell Modello Modelo Malli : CN203

Spice / Coffee Grinder Instruction Manual

MULTISTAGE ELECTRIC PUMPS

Slim Bottle Cooler. Instruction manual. Model: CS586

Operating manual Electronic Moisture Analyser

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Hamburger Machine Instruction manual

Instructions: Erkopress _motion. Erkopress ci motion

Slush/Chilled Drinks Dispenser Instruction Manual

Induction hob. Instruction manual. Model Modèle Modell Modello Modelo Malli: DF824

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Manual Isolating Barrier D461R1 (Revision 01)

Dual Temp Counter. Instruction manual. Model: DA994/DA995/DA996/DA997

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

TriScroll TM 600 Series Dry Scroll Vacuum Pump

Manual Isolating Barrier D461 (Revision 05)

Stainless Steel Multideck Display Instruction manual

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

GLASS WASHING MACHINE INSTRUCTION MANUAL

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Chest Freezer Instruction manual

Reference Manual. Ionizer Module for XPR Analytical Balances

Manual. Monitoring Device BS

Operating Instructions. Gharieni MLX Treatment Bed. Service-Hotline:

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

Hazardous Location Heaters. 50W and 80W Models INSTRUCTION MANUAL. Rev. I 2018 nvent P/N

OPERATING INSTRUCTIONS

Operating Instructions TSF 010. Power Failure Venting Unit PM BNE/L (0007)

Steam Cleaner Wasi-Steam 2

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

User Manual for Convection Oven

Hardware User s Manual

Suction Drawers LSG-02 D and LSG-02 DE

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

GB Operating instructions

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

02PN8 HI-PE/CF --- Rev. F044GB60K10 1

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

High Throughput Diffusion Pumps

KREBS DUO. - Assembly instructions. - Safety indications. - How to start and handle the machine. - Inspection and maintenance

OPERATING MANUAL RAY-NC 1000 SERIES

Hardware User s Manual

Centrifugal inline fans

Hardware User s Manual

Instructions SCHICK ceramic - milling set

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

OPERATING INSTRUCTIONS

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

Mercury Burner. No / / Description / Applications. 2. Installation / Operation ENGLISH

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Vacuum cleaner Instruction manual

Operating Instruction SCHICK ceramic - milling set

Millo / Millo pro. Nr x000 / 1805-x000

Plaster model trimmer HSS-99 with solenoid valve

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Transcription:

Operating Manual Ionizer KERN YBI-01 Version 1.1 03/2013 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com YBI-01-BA-e-1311

YBI-01-BA-e-1311 2

GB KERN YBI-01 Version 1.1 03/2013 Operating Manual Ionizer Table of Contents 1 GENERAL... 4 2 BASIC SAFETY PRECAUTIONS... 4 3 TECHNICAL DATA... 7 4 APPLIANCE OVERVIEW... 8 5 UNPACKING, SETUP AND COMMISSIONING... 9 Unpacking... 9 Placing... 9 Mains connection... 11 6 COMMISSIONING... 11 Turning on the ionizer... 11 Turning on the fan... 11 Applications:... 12 7 SERVICE, MAINTENANCE, DISPOSAL... 13 Cleaning... 13 Maintenance Service... 13 Disposal... 13 8 DECLARATION OF CONFORMITY... 14 3 YBI-01-BA-e-1311

1 GENERAL The ionizer has conductive peaks supplied by high voltage which, based on corona discharge, generate positively and negatively charged ions in the immediate vicinity. These are attracted by the electrostatic charge of goods to be weighed and, thus, neutralise the interfering electrostatic charge. This also does away with the forces falsifying the weighing (such as falsified weighing result, weighing value drifted). 2 Basic Safety Precautions WARNING The use of ionizer is only intended in combination with electronic weighing balances. Do not use for any other purposes. Never operate the ionizer in explosive environment. The serial version is not explosion protected. Protect the ionizer against high air humidity / temperature, steams and dust; Take care to select a location free of water and oil Do not expose the ionizer to strong humidity for extended periods. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected ionizer for ca. 2 hours at room temperature. Whilst the ionizer is switched on, do not touch the ion source; see sticker on the left side. In case of smoke development, smell of fire, strong heating-up of the ionizer or when the red LED starts glowing, turn off the ionizer immediately and disconnect it from the mains. If water or other foreign matter enters the ionizer, turn off the master switch immediately and disconnect it from the mains. YBI-01-BA-e-1311 4

On account of the high voltage technology, handle the ion source and exits with care. Do not take apart or modify the ionizer. Prevent damage caused by dropping, vibration or shock; see sticker on the left side. Always use the genuine power pack. The stated voltage value must be the same as the local voltage. Risk of injury! The peaks of the ion source are sharp and cutting. The ionizer generates poisonous ozone; ensure sufficient ventilation. For maintenance and repair work disconnect the ionizer from the mains. Disconnect the ionizer from the mains during periods of idleness. 5 YBI-01-BA-e-1311

CAUTION Maintain and clean the ionizer at regular intervals. Clean the ion source after 100 hours. Replace the ion source after 10 000 hours. Starting up a damaged ionizer may result in a short circuit, fire or electric shock. Starting up out of doors and inside vehicles is prohibited and will result in total loss of warranty. The occurrence of electromagnetic fields may result in major display deviations (incorrect weighing results). Discharge sample at a sufficient distance from the weighing balance. During normal operation the green LED will be glowing, in case of a breakdown the red LED. If the red LED is glowing, turn off the ionizer at the master switch and turn it on again. If the red LED continues to glow, inform the manufacturer. The ionizer may heat up slightly during operation. Prior to ionising powdery goods to be weighed, turn off the fan. Ionisation results are better when the fan is turned on and the period required for discharging the sample will be shortened. YBI-01-BA-e-1311 6

3 Technical Data Distance sample ion source Discharge time Ozone concentration Ion source Maximum air volume Weight Ambient conditions AC adapter (primary) Rated electric power supply Pollution Degree 2 Overvoltage Category Altitude Installation Site c. 5 50 cm 8 s/5 cm, 12 s/10 cm, 100 s/50 cm (with fan turned on) 0.04 ppm (2cm from ion source) Stainlees steel 0.06 cm 3 /min Ionizer 110 g, frame 430 g 0-40 C, 35 80 % air humidity (non-condensing) 100 240V, 400 ma 50/60Hz DC 12V, 1. A Category II Up to 2000 m device may only be used indoors 7 YBI-01-BA-e-1311

4 Appliance overview 1 7 9 10 2 5 6 3 8 11 4 1. Ionizer 2. Ion source 3. Discharge direction 4. Frame 5. LED Ionizer operation (green = normal operation, red = breakdown) 6. LED fan operation (blue = on) 7. Fan on- and off-switch 8. Knob for setting height / angle of inclination 9. Main switch 10. Mains adapter connection 11. Knob for permanent fixing of ionizer YBI-01-BA-e-1311 8

5 Unpacking, Setup and Commissioning Unpacking Remove device carefully from packaging, remove plastic wrapping and place device at the planned work place. Scope of delivery (1) Ionizer (2) Frame (3) Mains adapter (4) Operating instructions Placing Using it on a desktop The ionizer may be used as a desktop or hand-held device. 2a 1 2b Position knob (1) and tighten it by turning. Insert the ionizer into the V-shaped recess (2a 2b), ensuring a good fit 9 YBI-01-BA-e-1311

If the device is to be used permanently on a desktop, fix it with a set screw (3). 3 Use the knob on the frame to set the height and angle of inclination. Using it as a hand-held device To use it as a hand-held device, remove the ionizer from the frame as illustrated. YBI-01-BA-e-1311 10

Mains connection Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. Turn off the ionizer (master switch OFF ) before connecting it to the mains adapter. 6 Commissioning Turning on the ionizer Set master switch to ON. The green LED starts glowing. During normal operation the green LED will be glowing, in case of a breakdown the red LED. If the red LED is glowing, turn off the ionizer at the master switch and turn it on again. If the red LED continues to glow, disconnect the device from the mains and contact the manufacturer. After use turn off with master switch "OFF". Turning on the fan Ionisation results are better when the fan is turned on and the period required for discharging the sample will be shortened. Information: Turn off fan for powdery, easily whirled up samples. Set switch of fan to ON. The blue LED starts glowing. Ensure sufficient ventilation even when the fan is turned on. 11 YBI-01-BA-e-1311

Applications: The ionizer is designed to be used in combination with electronic weighing balances! Discharge of solids or weighing containers. Ionisation results are better when the fan is turned on and the period required for discharging the sample will be shortened. Use as desktop device. Discharge of powdery samples. Discharge prevents whirling up, problems with toxic samples. Turn off fan for easily whirled up samples. Use as desktop device. Discharge of goods to be weighed, glass wind screen or weighing containers. If your hand is inside the weighing chamber it will generate heat dissipation. Wait 2-3 minutes before reading the weighing value. Use as hand-held device inside weighing chamber. Discharge of beakers etc. Powdery samples are deposited at the inner wall of the glass when being poured into the beaker. This is prevented by discharging the beaker. Use as hand-held device outside the weighing chamber. YBI-01-BA-e-1311 12

7 Service, maintenance, disposal Cleaning WARNING Disconnect the device from the mains before cleaning / change of filter. Do not take apart the ionizer. Insert only completely dried filters. Fig. 1: Do not use aggressive cleaning agents (solvents etc.) instead clean with a soft cloth soaked in mild soap suds. Take care that the device is not penetrated by fluids and polish it with a dry soft cloth. Remove loose sample residues / powder carefully with the help of a brush or hand-held vacuum cleaner. For cleaning the ion source use a cotton stick moistened with alcohol; see fig. 1. Take care that the peaks are not bent. Fig. 2: For cleaning the filter use tweezers to remove it and clean it with water; see fig. 2 Wait until completely dry and reinsert. Maintenance Service Disposal The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. 13 YBI-01-BA-e-1311

8 Declaration of conformity EG-Konformitätserklärung EC- Déclaration de conformité EC-Dichiarazione di conformità EC- Declaração de conformidade EC-Deklaracja zgodności D GB CZ E F I NL P PL Declaration of conformity Prohlášení o shode Declaración de conformidad Déclaration de conformité Dichiarazione di conformitá Konformitätserklärung Conformiteitverklaring Declaração de conformidade Deklaracja zgodności RUS Заявление о соответствии Ionizer: KERN YBI-01 KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de Declaration of conformity EU Directive Standards 2004/108/EC EN 61326-1: 2006 2006/95/EC EN 61010-1: 2010 Tel: 0049-[0]7433-9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de EC-Declaration of -Conformity EC-Declaración de Conformidad EC-Conformiteitverklaring EC- Prohlášení o shode EC-Заявление о соответствии Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. We hereby declare that the product to which this declaration refers conforms with the following standards. Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami. Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt. Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes. Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, jest zgodny z poniższymi normami. Мы заявляем, что продукт, к которому относится данная декларация, соответствует перечисленным ниже нормам. Datum Date 27.03.2013 Signatur Signature Ort der Ausstellung Place of issue 72336 Balingen Albert Sauter KERN & Sohn GmbH Geschäftsführer Managing director KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com YBI-01-BA-e-1311 14