FF3 INDUSTRIAL ELECTRIC FAN HEATER PRODUCT MANUAL GENERAL SAFETY. Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug

Similar documents
FH3HT. 3Kw HIGH TEMPERATURE ELECTRIC FAN HEATER PRODUCT MANUAL

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

2.8KW ELECTRIC FAN HEATER

5KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER

3KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

INSTALLATION & USER INSTRUCTIONS

Imperial Electric Fires

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Installation & Operating Instructions

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

model No: ir20.v2 FUSE

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

Installation & Operating Instructions

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner. Instruction Manual

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ST E /ST E / ST E / ST E ST E / ST E / ST E

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

INSTALLATION & USER INSTRUCTIONS

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Whole Room Dryer WRD, WRD/110

INSTALLATION & USER INSTRUCTIONS

PARAFFIN/DIESEL HEATERS

OPERATING & MAINTENANCE INSTRUCTIONS

Oil Panel Heater Instructions for Use

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

INSTALLATION & USER INSTRUCTIONS

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Imperial Electric Fires

24 & 30 INCH DRUM FANS

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

infrared paraffin / kerosene / diesel heater

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Safety Warnings & Advice

INSTRUCTIONS AND WARRANTY

owner s manual & parts list

Drying Cabinet Installation and Operating Manual

Installation and Operating Manual Drying Cabinet

How to get the most from your Integrated Tumble Dryer HJA 8800

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

100 FLUEBOOST

2 KW OIL FILLED RADIATOR

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

GUH52SD 52 cm GUH75 75 cm Canopy Hood

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Electric Riva Flame-Effect Cassette Fire

Models: RP-10, RP-15, RP-20. User Manual

PH1000T PH1500T PH2000T

WET & DRY VACUUM CLEANERS

Operating Instructions

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

DEVIL CERAMIC SPACE HEATERS

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Owner s Manual Phoenix Aquadry TX 200

air conditioner/dehumidifier 9000btu/hr

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

900W OIL FILLED RADIATOR

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

INSTRUCTIONS FOR USE

Installation Instructions & Operating Manual IMPORTANT

INSTRUCTIONS FOR USE - TUMBLE DRYER AWG 367

2 KW OIL FILLED RADIATOR

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

space WARMER PARAFFIN / KEROSENE / DIESEL HEATER

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

HOTLINE:

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

Transcription:

Also available:- Ductable 3 Phase Fan Heaters:- FF13 415v - 16A 415v 3PH + Earth Supply (No Neutral required.) FF29 415v - 32A 415v 3PH + Earth Supply (No Neutral required.) FF42 415v - 63A 415v 3PH + Earth Supply (No Neutral required.) Industrial, high capacity air movers (Fans):- FF3 INDUSTRIAL ELECTRIC FAN HEATER MB30 110v & 230v/240v MB50 110v & 230v/240v MB2000 110v & 230v/240v Industrial Portable Air Conditioning Units:- MCM230 230v 23,000 BTU Mono Bloc MCM280 230v 28,000 BTU Mono Bloc MCM350 230v 35,000 BTU Mono Bloc MCWCS 250 230v 25,000 BTU Water Cooled Split can be piped 30 metres. *Also VF250, VF300 and VF600 Portable Industrial Fume Extractors. PRODUCT MANUAL Models Covered: FF3 ~ FF3T ~ FF3R 230v 13A Plug ~ 110v 16A / 32A Plug GENERAL SAFETY This equipment should only be used by a competent person who has read and fully understood these instructions. Never operate this equipment if you are ill, feeling tired or are under the influence of alcohol or drugs. Always switch OFF and unplug the equipment when not in use. Check condition of the equipment before use. If unit is showing signs of damage contact your supplier immediately.

WARNINGS Notes. These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. Failure to follow these instructions may result in risk of personal injury or damage to the equipment. Damage due to a failure to follow these instructions will invalidate the warranty. The appliance must be commissioned & serviced by qualified engineers in compliance with local regulations. The appliance must be switched off and disconnected from the power supply before any work is carried out. There are no user controls inside the appliance casing. Do not place anything on top of the appliance. Do not use in the vicinity of a pool, bath or shower. An air gap of at least 300mm should be allowed at the rear of the unit to ensure a clear airflow. Do not site the unit close to soft fabrics or combustible materials. Allow the unit to cool by running fan only for a minimum of 5 minutes before switching off. Do not disconnect the appliance from the supply under load. For internal use only. Do not use out of doors. Extension cables should be correctly rated for the load,fully unwound and never run through water or over sharp edges. NEVER cover the air inlet or outlet!

MACHINE SPECIFICATIONS MODEL FF3 WEIGHT 11 kg IP RATING IP20 MAXIMUM CURRENT 230v 12A 110v 25A POWER SUPPLY FF3 230V 230V 1 PHASE 50Hz FF3 110V 110V 1 PHASE 50 Hz ------------------------------- Standards Applied:- EN 55014-1: 2017 EN 55014-2: 2015 EN 61000-3: 2014 EN 12100-1: 2010 EN 12100-2: 2010 EN 60335-1: 2012 EN 60335-2: 2012 ------------------------------- Notes. Specifications: The FF3 is a single phase industrial electric fan heater. It is supplied as a 230v machine or a 110v machine. The 230v appliance is connected to a 13Amp 50Hz power supply and comes fitted with the appropriate UK mains plug. The 110v 3kW appliance is connected to a 32Amp 110v 50Hz supply and comes fitted with the appropriate plug. The 110v 1.5kW appliance is connected to a 16Amp 110v 50Hz supply and comes fitted with the appropriate plug. The FF3 is fitted with a high quality axial fan motor. The FF3 is fitted with an internal thermostat as standard. *If connecting a 110v machine to a transformer, please ensure it is CONTINUOUSLY RATED. Setup and operation: To start: Please note! The control panel is at the rear of the appliance. Site the appliance on a firm level surface. Connect to the appropriate power supply. Switch the rocker switch to I. Set the thermostat to the desired temperature. To stop: Turn the thermostat fully anti-clockwise and allow the fans to run for a minimum of five minutes to cool the machine. Failure to follow this procedure will damage sensitive components and invalidate the warranty. Switch the rocker switch to 0 when the heat has dissipated. If the heater is not in regular daily use disconnect from the power supply. Protective /safety devices: The FF3 is fitted with a safety limit thermostat. Should the maximum design operating temperature be exceeded it will shut down the heating element and leave the fan running. This device will automatically reset as the temperature reduces.

Spare parts: Maintenance: Fan motors, elements and switch gear are not customer serviceable components. General maintenance should include regular inspection of: 1. Mains cable. Check for signs of damage to the insulation.replace if necessary. 2. Air intake & outlet grills: ensure grills are free from accumulated debris. Blow out with compressed air if required. 3. Fixings: Check all fixings are present and secure.

Fault finding: Ducting A 2 metre length of ducting is available for use with the FF3 spigot models ask your supplier for details. When using ducting with an FF3, for safety reasons please observe the following:- Never extend the ducting beyond 2 metres. 2 metres is the maximum safe duct length. Always stretch the ducting to its full length to ensure good air flow. Keep the ducting as straight as possible. Never use the ducting with bends in it.