ATS2402E 8-64 zone integrated security panel EN50131 Grade 3, France

Similar documents
600 Range Dialer Installation Manual. Version 1.0

A Smart & Integrated Security solution

Pro Express catalogus

Professional Security Made Simple. The new CS Panel range

Catalogue. Security. systems

IC60 Sintony 60 Intrusion Control Panel

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

UltraSync Modular Hub

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

MKTCTBLEFURTINC R001. Catalogue nd Edition

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

SI120 Guarto Easy I. Alarm system. Fire & Security Products

IP & SMS Alarm Communicator

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

NEW GENERATION WIRELESS ALARM SYSTEMS

New generation wireless alarm systems

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

YOUR PARTNER IN FIRE & GAS DETECTION

Intrunet SPC series advanced security for a connected world

Solution F2. Fire Alarm Control Panels one step ahead.

CV-350 TCP/IP Access Control System. System Overview

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

ATS2000/3000/4000/4500 Control Panel. Programming guide

Flair 500 Series Annunciators

ALARM SECURITY PRODUCTS

ITALIAN SECURITY MANUFACTURER

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

TECOM SYSTEMS NETWORK MASTER

IntesisBox BACnet/IP Server - Notifier ID3000 series

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

HRX3000. Technical Manual

EC-BOS-602/616 AX Security

IRIS Touch Firmware Enhancements and Additions from Version to Version

SC-F3G User Manual 1.0

GSE PAC SYSTEM INSTALLATION MANUAL

ATS1250/ door/4-lift DGP. Programming Guide

Advisor Advanced Mobile Application User Manual

Fratech Multipath-IP

OmniPro II. Technical Sheet. DESCRIPTION

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

The Omni IIe Controller

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

ACTIVE INFRARED BARRIER

LIGHTNING PROTECTION SYSTEM

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Security designed for your lifestyle

IRIS Touch Engineering Manual. Version 1.2

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Common Questions & Answers

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Instructions manual. By-alarm. By-alarm Manager software

The Omni LTe EN50131 and PD6662 Compliant Controller

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Panel XT210/610/ Description. Supervised Wireless Technology

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SIMATRIX NEO Modular Video Matrix

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

idware Idware Remote Site Monitoring Solution

The future of security, secured IP by security professionals, for the professional security industry

JVA Electric Security Fence System. perimeter intruder detection system

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

KT-100 Door Controller

IRIS Touch Engineering Manual. Version 1.2

Remotely programmable and controllable alarm system

DS7400Xi Addressable Control/ Communicator

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Installation Manual Premier 412/816/832. Issue 10

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

The Omni IIe EN50131 and PD6662 Compliant Controller

CA60Plus. Installation manual

Model A1700 Series Annunciator

EVO192 v3.0 Fire and Burglary What s New

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Integrated Security Solutions

ATS125x/1260 Four- Door/Four-Lift DGP Programming Guide

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

The complete wirefree security alarm solution

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

EasyAlarm ELEVATOR LEITRONIC AG

High-End Wireless Security

alarm system VERSA Plus

Appendix 1 LACCD Districtwide Security Performance Requirements

SEE DISCLAIMER ON REVERSE

Access Professional Edition. The flexible access control system that grows with your business.

Panel XTO210/610/710 GPRS

BAT WIFI SKU: IPD-BAT--WIFI

Monitoring Solutions

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Alliance System Ordering Guide

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Intelligent security solutions UNCOMPROMISED SECURITY FOR YOUR COMPANY ALARM CONTROL PANEL INTEGRA

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

FC700A Fire detection control unit

Transcription:

ATS2402E 8-64 zone integrated security panel EN50131 Grade 3, France Intrusion Alarm System The Advisor MASTER (ATS Classic) offers a full-blown intrusion alarm system with more than 79 different input types, including support for EN50131 grade 3 Anti Mask detectors using only 1 input. A maximum of 128 zones (inputs) can be configured to operate in 8 independent alarm systems (areas). Zones may be assigned to a specific area (offices, stores, etc.) or common to multiple areas (reception, canteen). Each area may have a dedicated keypad (RAS) or can be controlled from any keypad. Areas support fullset and partset and can be controlled through PIN codes, cards or wireless keyfobs. Alarms can be reported through various communication paths like PSTN, IP, GSM or ISDN using standard protocols like SIA, XSIA or Contact-ID. The system is EN50131:2009 Grade 3 compliant. Integrated Access Control All ATS Classic panels control 16 doors up to 64 doors. Intrusion and access control is fully integrated allowing users to access doors while at the same time being able to control their areas. All panels also feature the exclusive "3 times badging" to arm. Complete Family The ATS Classic range is a family of control panels that all share the same features, software, accessories & manuals and only differ in enclosure size, number of zones and number of areas. Modular RS-485 data bus The ATS Classic panels communicate with up to 16 keypads and readers (RAS's) & 15 expanders (DGP's) using the RS485 data bus. All remote devices on the bus are continuously polled to ensure correct operation and availability. Different wiring schemes are supported to allow both new installations as well as retro-fit installations. The bus can be extended using additional modules like repeaters, splitters, optical fiber modules or RS485 to Ethernet converters. Les points forts Integrated alarm & access control system for up to 128 zones, 8 areas & up to 64 doors Modular RS485 data bus with continuous polling of up to 16 keypads/readers (RAS) and 15 expanders (DGP) PLC with 24 macro logic equations 255 free configurable outputs Built-in PSTN dialer. IP and GSM optional 2 or 4 state monitored analogue inputs including grade 3 anti-mask support Programming and servicing by PC either directly on site or from a remote location European software Switched mode power supply Steel enclosures EN50131:2009 Grade 3 compliant; Enviromental Class 2 Alarm reporting ATS Classic panels are capable of reporting alarms and specified events using a variety of formats (SIA, XSIA, CID, voice messaging and more) via different Page 1 sur 5

communication paths like IP, GSM, ISDN or PSTN (builtin). The system also supports multiple paths for primary and backup reporting. Page 2 sur 5

ATS2402E 8-64 zone integrated security panel EN50131 Grade 3, France Caractéristiques techniques Système Type de produit Contrôle d'accès intégré Type panneau Hybride Nbre de claviers / lecteurs 16 Panneaux (DGP) de collecte de données 15 Nombre de groupes d'alarmes 138 Câble spécifié WCAT52 WCAT54 Entrées Nbre max. d'entrées 64 Entrées embarquées 8 Plug-in extension d'entrées 32 Support ATS1202 3 Sorties Nombre de sorties 255 Nbre de sorties embarquées 4 Zone Nombre de zones 4 Utilisateur/cartes Nombre maximal d utilisateurs plus de 1000 Utilisateurs avec nom 200 Nbre max. de cartes 2000 Nbre max. de codes PIN 2000 Contrôle d'accès Portes standards sur centrales 16 Groupes de portes 128 Groupes d'étages 64 Portes intelligents sur 4 portes DGPs 48 Communication Type de transmission embarquée Extension de transmission Type de Databus Journal des événements Journal des événements d'alarme 1000 Journal des événements d'accès 1000 Électrique Tension de fonctionnement Type de bloc d alimentation Valeur de l'alimentation Consommation de courant Consommation de la carte mère Puissance d'alimentation Aux. maximum Fusibles détecteur de bris de verre PSTN GSM/GPRS/IP RS485 13.8 VDC supplied by the panel 230 VAC 230 V 50 Hz/23 VAC 56 VA 250 ma 130 ma 1A 7 (main panel) + 8 (ATS1840) Page 3 sur 5

En tant que société d'innovation, UTC Fire & Security se réserve le droit de modifier les spécifications des produits sans préavis. Pour les dernières spécifications du produit, visitez le site web d'utc Fire & Security ou contactez votre représentant commercial. 1 October 2018-9:34 AM Page 4 sur 5