Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Similar documents
TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Komo Thermostatic Bar Shower. Excluding Shower Kit

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Thermostatic Bath Shower Mixer. Without shower kit.

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Union coupling. copper x copper. Cone joint to BS 1010.

Basin Tap. Time delay maximum 2 seconds

Heating Controls Thermostatic and Manual Radiator Valve range

Male elbow, copper x BSP taper male thread

The new Terrier Belmont Thermostatic Radiator Valve range

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Varsity Concealed Shower System

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Dual Control Thermostatic Bath and Shower Mixer

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Mikrotherm. Manual Radiator Valves With presetting

Thermostatic valves with radiator connection systems

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Intatherm Safe Touch Basin Tap IT1008CP

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Multilux 4-Eclipse-Set

Flow Solutions Valves for Heating System Control

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Radiator Valve Program

HW3 Handwash Installation and Operating Instructions

LOCKSHieLD. ReMOTe ADJUSTeR. MANUAL VALVeS. Belmont commercial radiator valves. Pegler Yorkshire

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Installation, Operating and Maintenance Guide

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

RA2000 Commercial TRVs

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

Standard. thermostatic valve body without presetting

Inta City Concealed Shower Mixing Valve CT80010CP

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

TRV 300 RADIATOR VALVES

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Frequently Asked Questions

SOLUTIONS GUIDE. For total efficiency

Electronic Frost Thermostat

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Art-Line. Absolutely Brilliant Temperature control was never so good

caleffi hydronic valves page 1 of 12

Franke Specialist Range Pilatus Tap

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Section - A. Radiator Valves

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

FSW300 Series Flow Switch

Installation Instructions Flute Tap Range

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Thermostatic Bar Valves

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

X62 Tap Range. Please keep these instructions for future reference

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Enzo Concealed Shower Mixing Valve

Mercury Mixing Kit (Code: ME1053)

thermostatic valve body with stepless precision presetting

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Varsity Exposed Shower Systems

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

STRAIGHT AND ANGLED THERMOSTATIC VALVES

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Regulux. Radiator lockshield with drain-off facility. To be precise.

In-line thermostatic mixing valves

LOW SURFACE TEMPERATURE RADIATORS

Wet stove installation guide

2 DESCRIPTION OF SYSTEM COMPONENTS

Control valves for floor heating systems. Floor Heating Manifolds

Thermostatic valve bodies

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

Radiator Trap Radiator Valve

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Thermostatic Concealed Shower Valve

Dual Zone Wine Cellar

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Puro Mini Dual Control Shower Mixer PU90010CP

PENSOTTI TOWEL BAR WARMERS

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Transcription:

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT Straight pattern TRV & drain off lockshield pack Code A B C D E F Pegler Yorkshire reserve the right to change specifications Thermostatic and Manual Radiator Valves Pegler Yorkshire Customcare 5 Year Guarantee - Terms & Conditions Products are subject to a 5 year guarantee that is between Pegler Yorkshire and the final purchaser of the product. The guarantee is subject to proof of purchase being supplied. This guarantee does not affect any statutory rights the consumer may have in law. The guarantee covers manufacturing or material defects and is not applicable where the product is fitted contrary to conditions of use in our literature. The guarantee is subject to the following limitations: 1. The valves are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. 2. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions (Maximum) System Water Temperature (at 5bar) : 120 C Operating pressure (at 65 oc) :10 bar 3. Under no circumstances must they be used to in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer s instructions. 4. Damage caused by abusive behaviour and accidental damage to the product are not covered by this guarantee The extent of Pegler Yorkshire liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages.

Description Minimum Operating Pressure (bar) Maximum Cold Working Pressure (bar) Maximum Hot Working Pressure (bar) Straight Pattern TRV & Drain Off Lockshield Pack No Minimum Operating Pressure 10.0 bar at temperatures up to 120oC Not Suitable for Maximum Hot Working Pressure Care The TRV can be easily cleaned with a soft damp cloth wiping over the handle (plastic) and valve body. Maintenance No maintenance is required for this product. When removing the TRV head for decorating or replacement purposes, turning the head setting to 5, this enables an easier removal. A manual shut off cap is provided with the product to protect the valve whilst any surrounding maintenance work is undertaken. For any further help or replacement parts please contact the Service Support Team on: 0800 1560050. Regulations Terrier thermostatic radiator valves are approved to EN 215. For valves with compression connections, the connections are approved to BS EN1254-2; threaded connections comply with BS 21 or BS 2779. They are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions Maximum System Water Temperature (at 5bar) 120 C Operating pressure (at 65 C) 10 bar Under no circumstances must they be used in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer's instructions. Terrier heating controls are manufactured to a strict quality assurance system in accordance with ISO 9000: 2001. Component Body Head Gland Flow Spindle Capnut Cone Adaptor Thermal Head Cover/Body Thermal Head Element/Housing Body Head Spindle/Valve Glandnut/Gland Adapter Capnut Cone Set Screw Lockshield Material TRV - Forged Brass Chrome Plated TRV - Brass Bar TRV - Brass Bar TRV - Stainless Steel TRV - Forged Brass Chrome Plated TRV - Brass Bar TRV - Brass Bar Chrome Plated TRV - ABS TRV - Noryl DLS - Forged Brass Chrome Plated DLS - Brass Bar DLS - Brass Bar DLS - Brass Bar DLS - Forged Brass Chrome Plated DLS - Forged Brass Chrome Plated DLS - Brass DLS - Brass DLS - Polypropylene 59 Nipple (Groove x Thread)

Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Telephone: Phone +44 (0) 844 243 4400 Fax: +44 (0) 844 243 9870 Website: www.pegleryorkshire.co.uk Registered office : Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Company no : 00401507

4. Range Limiting or Fixed Set Temperature The terrier TRV has the facility for fixing the thermal head at a set temperature or to limit the range of operation. This is achieved by using two pegs. 5. How to use limiting pins 5. How to use limiting pins To obtain a fixed set point, locate a peg in the slot either side of the To selected obtain setting a fixed and set push point, home. locate a peg in the slot either side of the selected setting and push home. To set a limited range for temperature control, first locate a peg in the To slot set to a the limited right range of the for viewing temperature window control, for the lowest first locate temperature a peg in setting the slot required. to the Adjust right of the the valve viewing head window to display for the maximum lowest temperature temperature setting required. desired. Locate Adjust a the peg valve in the head slot to to display the left the side maximum of the viewing temperature window. desired. Push both Locate pegs a home. peg in The the head slot to will the now left be side adjustable of the viewing between window. the Push selected both range pegs of home. temperature. The head will now be adjustable between the selected range of temperature. * If you require this facility please call 0870 1200281 and order your free * If pins you on require order code this facility 850888. please call 0870 1200281 and order your free pins on order code 850888. 6. Frost Protection 6. Frost Protection If you plan to be away from home for any length of time the TRV can be If turned you plan to the to frost be away protection from home setting for. any If length the temperature of time the TRV falls can below turned 7 C the to valve the frost will automatically protection setting open. giving If the protection temperature against falls freezing. below 7 C (Provided the valve that will the automatically boiler remains open in operation giving protection via a frost against stat.) freezing. (Provided that the boiler remains in operation via a frost stat.) 7. Removal of Radiator 7. Removal of Radiator The 0 Setting on the TRV is a positive Off position. This will enable a The radiator 0 Setting to be removed on the TRV for maintenance is a positive Off purposes. position. This will enable a radiator to be removed for maintenance purposes. To avoid accidental operating of the valve or damage whilst decorating To the avoid manual accidental shut off operating cap may be of used the valve for added or damage security whilst instead decorating of the the TRV manual head. In shut this off case, cap remove may be the used TRV for sensor added head security by unscrewing instead of the TRV securing head. ring In this and case, replacing remove with the the TRV manual sensor cap head BEFORE by unscrewing removing the the securing radiator. ring and replacing with the manual cap BEFORE removing the radiator. TWO WAY THERMOSTATIC RADIATOR VALVE TECHNICAL DATA Temperature range 7 C - 28 C Maximum Test Pressure 20bar Maximum Static Pressure 10bar at 120 C Maximum Differential Pressure 0.6bar Maximum Water Flow Temperature 120 C Pegler Yorkshire Pegler Yorkshire Group Limited, St. Catherine s Avenue, Doncaster, DN4 8DF. Pegler Limited, Tel: 0844 St. Catherines 243 4400 Fax: Avenue, 0844 Doncaster 243 9870DN4 8DF. Telephone: 01302 560560 Fax: 01302 367661 TWO WAY THERMOSTATIC RADIATOR VALVE Installation and User Guide SENSOR HEAD VALVE BODY MANUAL SHUT OFF CAP 1/2 BSP TAIL VALVE BODY STRAIGHT

INSTALLATION Directions for use: Angle TRV The universal terrier TRV is designed to operate with water flow in either direction. The 15mm size may be fitted in either the horizontal OR vertical position. The most effective position is to have the head in a horizontal position where the greatest efficiency will be obtained. Straight TRV Straight bodied valves should not be used in the top connection of a radiator as heat from the radiator will affect the sensor. Correct installations Correct installation and maximum performance will be achieved if: The thermostatic head is not concealed behind furniture, curtains or drapes, hidden under shelves, panelling or in a recess where air pockets can occur. The thermostatic head is not exposed to direct sunlight or draughts. Straight TRV x Fitting 1. Thoroughly clean any pipe work to be connected to the valve. 2. Drain down existing system, connecting a hosepipe to the lowest drain off point available. 3. Screw 1/2 BSP tail into radiator tapping, using suitable jointing material e.g. PTFE tape. 4. Connect valve body to tail and tighten nut. 5. Cut and fit copper tube to valve body - tightening nut and cone. 6. Remove manual shut off cap and store safely. 7. Turn Sensor head to indicate 5 in setting window. 8. Position sensor head so that setting window can be viewed and hand tighten securing ring to valve body. 9. Set sensor head to required temperature setting. 10. When fitting a lock shield valve, this must be set to control the water flow through the radiator to the correct level. PLEASE NOTE: To avoid the problem of hydronic (water flow) noise it is recommended that the differential pressure does not exceed 0.2 bar. It is strongly recommeded that a differential pressure valve should be fitted to any system with TRV s (Pegler order code for differential pressure valve 678021/22mm) will be suitable for most domestic installations. Larger sizes are available if required. USER INSTRUCTIONS 1. Operating Description The influence of uncontrolled heat gains from cooking, lighting and sunshine etc., can lead to wasteful overheating. The terrier TRV is designed to react to temperature fluctuations and allow you to control individual room temperature. The sensor head contains a powerful wax-filled sensor which senses temperature changes. These variations cause expansion and contraction of the thermal element which is transmitted to a valve seat which regulates the water flow to the radiator 2. Setting the TRV Initially set the TRV to the required room temperature from the table below e.g. Position 3/ 20 C. The TRV should be left for at least 1 hour to allow the temperature to stabilise. If a higher or lower room temperature is required simply adjust the setting accordingly and repeat the process. 3. Temperature Settings The TRV settings are factory calibrated as indicated in the table below. 0 1 2 3 4 5 Shut Off 7 C 11-13 C 15-17 C 19-21 C 23-25 C 27-29 C Note: These temperatures may vary slightly, depending upon the nature of the installation Angle TRV

This is to certify that: Pegler Yorkshire Group Limited Belmont Works St Catherine's Avenue Doncaster South Yorkshire DN4 8DF United Kingdom Holds Certificate Number: 003-CCC3-E00002 In respect of: BS EN 215 Thermostatic Radiator Valves The right and certificate to use the CEN/CENELEC Internal Regulations. The CEN/CENELEC European Mark System, governing the use of the Keymark, which may be periodically updated by CEN/CENELEC and the Specific CEN Keymark Scheme Rules for Thermostatic Radiator Valves. The Keymark is authorized to be affixed to products manufactured at the above address and in conformity with the stated European Standards detailed in the following pages(s). For and on behalf of BSI: Gary Fenton, Global Product Certification Director Page: 1 of 7 Page: 1 of 7

EN 215 Thermostatic Radiator Valves Terrier II Two Way Terrier II Two Way Chrome Belmont Mistral II B1301-0/4 B1401-0/4 Thermostatic radiator valve / sensor head remote B1701-0/4 Thermostatic radiator valve / sensor head remote Mistral II Chrome Bulldog PTS Boss TRV Thermostatic valve / sensor head integral Page: 2 of 7

EN 215 Thermostatic Radiator Valves PTS Boss TRV Chrome Regis Regis Chrome Regis II Chrome Page: 3 of 7

EN 215 Thermostatic Radiator Valves Plumbase Contract Page: 4 of 7

EN 215 Thermostatic Radiator Valves CEN Information declared by manufacturer Terrier TRV Range ½ x 15mm Angle TRV Valve ½ x 15mm Straight TRV Valve ½ x 15mm Mistral II Angle TRV Valve ½ x 15mm Mistral II Straight TRV Valve Terrier Thermal Head Terrier Thermal Head Chrome Plated Mistral II Thermal Head Mistral II Thermal Head Chrome PTS Boss TRV PTS Boss TRV Chrome Bulldog Regis Regis Chrome Plated Thermal Head Iflo contract Regis II Regis II Chrome Plated Bulldog Gen 2 Thermal Head Nominated Flow Rates ½ x 15mm Angle TRV Valve Forward and Reverse Flow 190 kg/h ½ x 15mm Straight TRV Valve Forward and Reverse Flow 190 kg/h ½ x 15mm Mistral II Angle TRV Valve Forward and Reverse Flow 190 kg/h ½ x 15mm Mistral II Straight TRV Valve Forward and Reverse Flow 190 kg/h 190 kg/h Hysteresis All Thermal Heads Differential Pressure Influence All Thermal Heads Water Temperature Influence Thermal Heads with plain base Thermal Heads with Chrome plated base Response Time All Thermal Heads 0.75 K 0.6 K 0.15 K 0.1 K 0.9 K 1.2 K 1.1 K 20 min 20 min Page: 5 of 7

EN 215 Thermostatic Radiator Valves CEN Information declared by manufacturer Terrier Décor TRV Range ½" x 15mm Angle TRV Valve ½" x 15mm Straight TRV Valve Terrier Decor White Thermal Head Terrier Decor Anthracite Thermal Head Terrier Decor Chrome Thermal Head Nominated Flow Rates ½" x 15mm Angle TRV Valve Forward and Reverse Flow 190 kg/h ½" x 15mm Straight TRV Valve Forward and Reverse Flow 190 kg/h Hysteresis All Thermal Heads Differential Pressure Influence All Thermal Heads Water Temperature Influence Chrome Thermal Heads White and Anthracite Thermal Heads 0.62 K 0.08 K 0.9 K 1.2 K Response Time All Thermal Heads 20 mins Page: 6 of 7

EN 215 Thermostatic Radiator Valves CEN Information declared by manufacturer Belmont and Boss Range ½ Vertical TRV valve ½ Vertical TRV valve pre-setting ½ Horizontal TRV valve ½ Horizontal TRV valve pre-setting ½ Straight TRV valve ½ Straight TRV valve pre-setting ¾ Vertical TRV valve ¾ Vertical TRV valve pre-setting ¾ Horizontal TRV valve ¾ Horizontal TRV valve pre-setting ¾ Straight TRV valve ¾ Straight TRV valve pre-setting Standard Thermal Head Remote Sensing Thermal Head Remote Adjusting Thermal Head Nominated Flow rates ½ Angle and reverse angle forward flow 206 kg/h ½ Angle and reverse angle reverse flow 220 kg/h ½ Straight pattern forward and reverse flow 195 kg/h ¾ patterns 265 kg/h Hysteresis 0.5 K Differential Pressure influence All variants forwards All variants reverse - 0.15 K 0.25 K Water Temperature Influence Fixed thermal head 0.9 K Remote sensing and remote adjusting heads 0.5 K Response time All TRV head variants - vertical All TRV head variants - horizontal 24 minutes 20 minutes Page: 7 of 7