PROFESSIONAL - SSE Stainless steel interior and exterior (with galvanized back and bottom) Innovative variable speed compressor with adaptive control technology Energy efficient thermostatic expansion valve, self contained refrigeration system Two years parts and labor warranty
VSC COMPRESSOR MODULE CAUTION! Do not attempt to repair the compressor electronic unit COMPRESSOR OPERATION The compressor adjusts its speed in steps to any in-creasing or decreasing cooling demand, within the minimum and maximum speed limits. If the thermo-stat switches the compressor "ON": After a 60-minute running time, the speed will increase stepwise every 15 minutes, depending on the latest speed used, until the maximum is reached. If the thermostat switches the compressor "OFF": After each "ON", the compressor either restarts with lower speed steps than the recently used, until the minimum is reached, or increases its speed stepwise, after a new 60-minute running time. Comp Circuit Diagnosis: If Comp does not start, check for 115VAC at K1 connector pin #10 gray (GY) wire to any white (W) neutral wire. If 115VAC is not present, CB is bad and must be replaced. If 115VAC is present, check for 115VAC at Comp relay coil gray (GY) wire to any white (W) neutral wire. If 115VAC is present, and Comp is not on, check for 115VAC at Comp relay orange (O) wire to Comp relay red (R) wire. If 115VAC is present, Comp relay is bad and must be replaced. If 115VAC is not present, check for 115VAC at Comp relay red (R) wire to any white (W) neutral wire. If 115VAC is not present, electronic unit is bad and must be replaced. If 115VAC is present, and Comp is not on, remove the electronic unit to access Comp terminals. Next, check for 80VAC from each Comp terminal to ground. If 80VAC is not present, electronic unit is bad and must be replaced. If 80VAC is present, check Comp continuity.
SSE CONTROL CIRCUIT -SSE CONTROL BOARD RIBBON CABLE DISPLAY BOARD
Professional CLICK LABEL FOR PRINTABLE VERSION
SSE SERIES CONTROLLER ADJUSTMENT GUARDED ACCESS MENU Press the UP and DOWN keys together for three seconds. Press both buttons at the same time
SSE SERIES CONTROLLER ADJUSTMENT GUARDED ACCESS MENU 1st Adjustment: Temperature Setpoint Average cabinet temperature 2nd Adjustment: Defrost Frequency Refrigerator: Automatic defrost df X has no effect Freezer: Ex. df 4 = 4 defrost per day 3rd Adjustment: Units of display: F = Fahrenheit C = Celsius
TEMPGUARD (SSE) DISPLAY CODES Alarm display~ Alternates between code and box temp. E1- High Cabinet temperature ~ 3 Beeps 25 F above set point for more than 4 hours E2- Low cabinet temperature ~ 4 Beeps 8 F Below set point for more than 1 hour E3- Freezer defrost over 1 hour ~ 5 Beeps E4- High pressure 3 x in 1 hour ~ 6 Beeps (5 x cuts off) E6 - E7 High voltage (8 Beeps) and Low voltage (9 Beeps) E8 - E9 Defrost or Cabinet temperature sensor failure (Continuous buzzer) E10 Communication error (Dual Temp only) def Unit in defrost or recovery door~ Displays when open~ 2 Beeps if open>3 Min CF~ Clean filter ~ 1 Beep.
PROFESSIONAL SSE REFRIGERATOR
PROFESSIONAL SSE REFRIGERATOR DEFROST INIATION LED 5 (ConFM) is ON LED 3 is OFF (EvapFM ON), when the DTh cools to 13 the 20 min. minimum off cycle defrost starts. Cabinete temperature displayed on DB, EvapFM continues ConFM continues or energizes DEFROST TERMINATION LED 4 (Comp) & LED 5 (CondFM) ON When the DTh warms to 40 EvapFM and ConFM continue, the 2.5 minute Comp delay timer terminates and the Comp. energizes SWITCH ON LED 3 is OFF (EvapFM ON), 2.5 min. Compressor delay timer starts, Cabinet temp. appears on display after the CB revision # (r##) COOL DOWN LED 4 (Comp) & 5 (ConFM) are ON EvapFM continues, the 2.5 min. Comp. minimum run timer starts COOL DOWN RESTART LED 4 (Comp) & LED 5 (ConFM) are ON CTh warms to 3 above the set point, EvapFM continues, Comp. and ConFM energize 2.5 min. Comp. minimum run timer starts COOL DOWN ACHIEVED LED 3 is OFF (EvapFM ON) CB monitors the CTh when it cools to 3 below set point the Comp. and ConFM de-energize EvapFM Continues and the 2.5 min. Comp. minimum off timer starts
PROFESSIONAL SSE Freezer
PROFESSIONAL SSE Freezer DEFROST RECOVERY (DRIP TIME) P5 and earlier LED 4(Comp) & 5 (ConFM) are ON LED 3 is OFF (EvapFM is ON) DTh warms to 100 or the 1 hr. timer terminates. DH de-energizes 5-min. later Comp & ConFM energizes EvapFM continues P6 & later LED 3 (EvapFM OFF), 4 (Comp), & 5 (ConFM) are ON, DTH warms to 100 or 1 hr. timer terminates DH de-energizes 5-min. later Comp. & ConFM energize When the DTh cools to 70 or lower the EvapFM energizes. DEFROST COMPLEATION LED 4(Comp) & 5 (ConFM) are ON, LED 3 (EvapFM is OFF) when the CTh reads 15 above the set point or less Cabinet temp. will now be displayed SWITCH ON P5 & Earlier LED 3 ON (evap. Fan off) 2.5 min. comp. delay timer starts, cabinet temperature appears on display board P6 and later LED 3 off (evap. Fan ON) 2.5 min. comp. delay timer starts, cabinet temperature appears on display board NOTE: Evap. Fan motor operation LED 3 OFF fan ON, LED 3 On fan OFF. P5 and earlier S3 dip switch 7 or 8 (OFF) = EvapFM cycles on and off with compressor, as well as with door. P6 and later S3 dip switch 7 or 8 (ON) =EvapFM on continuous from start-up, only shuts off when door opens COOL DOWN P5 and earlier LED 4(comp) & 5 (ConFM) are ON, LED 3 is OFF (EvapFM) ON Time or manual-initiated Defrost (The time initiated def. is factory set 6 times per day or every 4 hours) P5 and earlier LED 1 (DH) & 3 are ON (EvapFM OFF) DT terminates or manual defrost initiated, 20 minute minimum timer starts, 1 hour max timer starts and def is displayed P6 and later LED 1 (DH,DrH,DcTH, and CordH) and 3 are ON (EvapFM OFF) DT terminates or manual defrost initiated, 20 minute minimum timer starts, 1 hour max timer starts and def is displayed COOL DOWN RESTART P5 and earlier LED 4(Comp) and 5 (ConFM) are ON, LED3 OFF (EvapFM ON) CTh warms to 3 above setpoint 2.5 min. Comp delay timer terminates (Comp., ConFM, and EvapFM energize) P6 and later LED 4(Comp) and 5 (ConFM) are ON, LED3 OFF (EvapFM ON) CTh warms to 3 above setpoint 2.5 min. Comp delay timer terminates (Comp., ConFM, and EvapFM continues and Comp. and ConFM energize COOL DOWN ACHIEVED P5 and earlier LED 3 ON (EvapFM OFF) CB monitors CTH when box gets 3 below set point (Comp, ConFM, & EvapFM de-energize ) P6 and later LED3 OFF (EvapFM ON) CB monitors CTH when box gets 3 below set point EvapFM continues, Comp and CondFM de-energize P6 and later LED 4&5 (comp., ConFM) ON, LED 3 OFF (EvapFM) ON continuous