UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

Similar documents
UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Flow Control for Fire Protection

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Flow Control for Fire Protection

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

F4060 RESILIENT SEATED GATE VALVES

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Facility Fire-Suppression Water-Service Piping

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

INFACT CORPORATION WATERWORKS PRODUCTS FLEX REDUCER SPECIFICATION S TOLL FREE:

Port of St Helens SIA Aircraft Hanger Scappoose, OR

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

SECTION FIRE PROTECTION

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

MARLOW PUMPS RECIRCULATION

#2 ECLIPSE POST HYDRANT PARTS LIST. O-Ring for Top Screw (requires 2 per screw)

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

B. Related Sections: The following Sections contain requirements that relate to this Section.

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

DIVISION 21 - FIRE SUPPRESSION

Full-line Product Overview

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SECTION DRY-PIPE SPRINKLER SYSTEMS

DIVISION 21 - FIRE SUPPRESSION

Anvil International is the largest and most complete fitting and hanger manufacturer in the world. TODAY

Orange Township Fire Department Fire Prevention Bureau

SPRINKLERS TABLE OF CONTENTS

Troubleshooting the MPH 24FP Series Pedestal Hydrant

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

SECTION FIRE-SUPPRESSION STANDPIPES

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

SECTION FIRE PUMP AND CONTROLS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Used Fluid Handling Portable Used-Oil Gravity Drains

A. This section includes design and performance information for fire protection and suppression systems.

Lubrication Tools and Equipment Portable Oil Drains

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION DOMESTIC WATER PIPING SPECIALTIES

Used Fluid Handling Portable Used Oil Gravity Drains

VALVES SECTION 15100

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

KEENER GRINDER PUMPS

SIHI multi Modular multistage pumps

SECTION SECTION DESIGN REQUIREMENTS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Worldwide Contacts. Technical Data

ADDENDUM NO. 3 March 19, 2018

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Technical Data. Sizes 2 12 Inch (DN50 DN300)

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

1.02 SUMMARY A. This Section includes piping and specialties for combined potable-water and fire-protection water service outside the building.

SECTION AUTOMATIC SPRINKLER PIPING

LINDOFLAMM thermal engineering.

Zurn Fire Protection - Overview. December 2018

CONTRACT FOR USE OF FIRE PROTECTION SYSTEM

Series 1140 and 1141 Temperature Regulators

A. This Section includes the following domestic water piping specialties:

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

TYPE LF/LC/LCV END SUCTION PUMPS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Operation, Maintenance and Installation Manual

HOMA Pump, Ansonia Connecticut

SECTION FIRE SUPRESSION

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

SULLAIR DESICCANT DRYERS

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

INSTRUCTION AND REPAIR MANUAL

Transcription:

UL/FM Fire Protection Products Reliable fire protection products for your commercial, industrial, or institutional property.

Reliable UL/FM Fire Protection Products Markets Power Institutional Company Overview U.S. Pipe Valve & Hydrant is a leader in high-quality commercial and institutional fire protection products, offering a broad range of carefully designed, durable, reliable and easily maintained fire protection products compliant to UL/FM requirements. Plus, all U.S Pipe Valve & Hydrant products are backed by the company s expert technical support, superior service, and ready parts availability. U.S Pipe Valve & Hydrant UL/FM fire protection products set the standard for performance and reliability year after year. U.S Pipe Valve & Hydrant Water Distribution Products are available through Authorized Stocking Distributors in all parts of the United States, and are sold around the world through qualified distributors and representatives. U.S Pipe Valve & Hydrant s flow control and fire protection products are used in the building and maintenance of infrastructure. This includes Power, Institutional, Oil & Gas, Chemical and more. Oil & Gas Core Values U.S. Pipe Valve & Hydrant has a set of Core Values to help us think, act and work together to benefit all of our stakeholders from our employees who are our most valued assets, to our customers who expect quality products and service. Chemical These Core Values are not an end in themselves. Rather, they form the foundation of our culture, define behaviors required of us all and guide our decision making. As a company and as individuals, we will: Act with integrity do the right thing Treat each other with respect Build relationships Promote a culture of innovation and continuous improvement Deliver exceptional results Foster a safe and environmentally responsible culture

Fire Hydrants U.S. Pipe Valve & Hydrant fire hydrants are known throughout the fire protection industry for superior flow characteristics, dependability, ease of repair, and aftermarket support. Metropolitan /M-94 and Sentinel hydrants are manufactured in an ISO 9001 facility in Albertvile, Alabama, USA and are backed by a 10-year limited warranty on materials and workmanship. Sentinel 250 Fire Hydrant M-94 / Metropolitan Fire Hydrant Mueller Centurion Monitor Style Fire Hydrant Sentinel 250 and Metropolitan/M-94 Fire Hydrant Features Ductile iron bonnet features no bolts to disassemble Anti-friction bearing made of tough, wear-resistant polymer for easy operation Sealed lubricant reservoir is a closed system, where all-temperature grease coats the stem threads, thrust collar, and anti-friction bearing Large, smooth radius hose and pumper openings on upper barrel reduce friction loss and promote full flow; threaded-in hose and pumper nozzles are field-replaceable Two-piece standpipe coupling design uses two bolts to connect upper and lower standpipes Reversible compression-type main valve closes under pressure for tight seal; provides a convenient replacement (Sentinel hydrant only) Meets of exceeds all applicable parts of AWWA C502 & C550, UL246 and FM1510 10-year limited warranty Inlet connections: Flanged, Mechanical Joint, D-150 Mechanical Joint, and Slip-On Pressure rating: Up to 250 psig Mueller Centurion Monitor Style Features Eliminates possible leak path with separate monitor nozzle attachment Full flow 4-way openings: 4 monitor elbow, one 4 1 /2 pumper nozzle and two 2 1 /2 hose nozzle Integral monitor mounting allows easier monitor nozzle hook-up.

Gate Valves & Check Valves U.S. Pipe Valve & Hydrant Resilient Wedge Gate Valves feature a forged bronze stem and thrust collar (through 16 ) for superior strength, an elastomer-encapsulated ductile iron wedge and engineered polymer guides to stabilize the wedge and prevent binding. Connection options include: mechanical joint (MJ), flanged (FL), slip-on (SL), radial compression (RAD), and threaded (THD). Styles: NRS, PIV, and OS&Y. U.S. Pipe Valve & Hydrant UL listed and FM approved check valves are gravity operated, swing check design. These check valves are rugged in construction and simple in design. 350psi Post Indicator Resilient Wedge Gate Valve (PIV) (P-USP1) OS&Y Resilient Wedge Gate Valve (R-USP1) Swing Check Valve (Mueller A-2120-6BB) Gate Valve Features 100% encapsulated wedge with extended wedge guides Polymer guide cap bearings on wedge guides resist wear and provide easy operation Smooth, oversized, unobstructed flow way provides superior flow characteristics; reduces pumping costs Mueller Pro-Gard fusion bonded epoxy coating Bi-directional flow 10-year limited warranty Pressure ratings: P-USP1 (4-12 ) = 350 psig; R-USP1 (2-12 ) = 350 psig; R-USP1 (14-16 ) = 250 psig; R-USP1 (18-24 ) = 175 psig UL Listed/FM Approved (2-24 ) Mueller Check Valve Features Removal of all parts through the top of the valve, without removing the valve from the line Directional arrow leaves no doubt of flow direction Check valves bossed on both sides of the body for connecting bypasses and are bossed at the bottom under inlet end to allow drain valve attachment; tapping is optional Check valves available with either rubber or bronze disc facings Pressure ratings: 2 1 /2-12 = 200 psig

Indicator Posts U.S. Pipe Valve & Hydrant indicator posts are used in fire protection systems and perform several functions. The indicator post provides a means to operate a buried or otherwise inaccessible valve. Also, the indicator post readily and clearly indicates whether the valve is open or shut. Wall-Type Indicator Post (U-20814 4-14 ) Adjustable Indicator Post (U-20806 4-14 & U-20807 16-24 ) Indicator Post Features Easy to see targets indicates whether the valve is open or closed Designed to withstand up to 900 ft.-lbs. of operating torque Unique operating wrench design makes indicator post tamper-proof Designed to operate 4 through 24 post indicator valves, requiring 14 to 75 turns, respectively, to open For trench depths from 1 4 to over 17 feet. All styles have a cast boss on the upper barrel tapped with 1 /2 NPT to allow for optional supervisory switch installation UL Listed (4-24 ); FM Approved (4-14 )

Our Products Mueller Co. manufactures U.S. Pipe Valve & Hydrant fire hydrants and gate valves, as well as a variety of other water distribution and fire protection products. Our valves and hydrants are manufactured in the United States at plants specifically designed to make only these products. These plants are ISO 9001 certified, your assurance they operate under the highest quality standards. Our People Our customer service representatives are dedicated to helping you with your water distribution flow control needs. Their experience and thorough understanding of valves and hydrants means you can count on getting the assistance you are looking for when you call our toll-free number. For more information about U.S. Pipe Valve & Hydrant water products, please visit www.uspvh.com or call customer service at 800.871.2194. U.S. Pipe Valve & Hydrant, LLC 500 Eldorado St. Phone: 217.425.2194 Decatur, IL 62522 Toll Free: 1.800.871.2194 www.uspvh.com support@uspvh.com Copyright 2017 U.S. Pipe Valve & Hydrant, LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of U.S. Pipe Valve & Hydrant, LLC, its affiliates or other third parties. Products above marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your U.S. Pipe Valve & Hydrant Sales or Customer Service Representative concerning any other application(s). Form 12590 - Rev 5/18