Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating.

Similar documents
MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

FEATHERWEIGHT PRO USER GUIDE 1703 SERIES

Installation and assembly instructions. for standard configuration radial blowers

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Airbrush Compressor & Vacuum Pump AS20W ARTICEL 34202

GWC1815 GWC1820PC.

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Propane Flame Projector Safety instructions and operating manual

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

EN Z Subject to change due to technical improvements! Operating instructions

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

HELMUT KÄMPKEN GMBH OPERATING MANUAL

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

SILENT compact /

YOUR PORTABLE AIR PURIFIER

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

INSTRUCTION MANUAL W-400

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

User manual UV Flash Dry C1

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Read these instructions before using and keep them available at all times!

GB Operating instructions

Test Unit GTL 100 for Fire Detectors

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Operation Manual. For. Herbicide Sprayer

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Operating Instructions

YOUR AROMATHERAPY DIFFUSER

PJ130S High Pressure Cleaner

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

MULTI Hand Vacuum USER GUIDE 1985 SERIES

Operator s manual. Battery charger C 48/ en / 03

Register your new Bosch now: Sensixx x DA70. en Operating instructions

55-Gallon Dispenser Package

WET & DRY VACUUM 1250W 12L WARRANTY INSTRUCTION MANUAL SPECIFICATIONS VWD-1212 WHAT S IN THE BOX

EtherCAT Box Modules (EPxxxx-xxxx)

Operating Instructions!

infrared paraffin / kerosene / diesel heater

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors

POWER CUT Hedge Trimmer 46 Model No. 101HT450

Combivac Operating Instructions Combivac

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

IMpORTANT SAFETy INSTRUcTIONS

MULTI REACH Stick Vacuum

L / -014L / -015L

Operating Instructions. Rotating Vacuum Filter Type VRF

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

55-Gallon Dispenser Package

POWER CUT Cordless Hedge Trimmer Model No. 101HT18V

Product Manual Glue Applicators MS 80 and MS 200

Operation Manual. Pond Pump Series HJ and CQP

ATRIX REVO RED bagless HEPA CANISTER VACUUM CLEANER

Ozonizer XT Instructions

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

CO 2 EXTINGUISHING SYSTEMS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

2-IN-1 UPRIGHT HANDHELD VACUUM CLEANER INSTRUCTION MANUAL

RISK ENGINEERING GUIDELINE.

Operating Manual. VIENNA Hot Display

USER S MANUAL ATH WH220

Operating and Maintenance Instructions

GETZ MANUFACTURING PART # CYLINDER DRYER

1 HP Air Mover. Owner s Manual

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

User instructions. egger EL 1 REF (230 V) REF (115 V)

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

V-ZUG Ltd. Range hood. Mistral/Bora. Operating instructions

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

SAFETY AND OPERATING MANUAL

PERFECT CURLS 2-IN-1

SAFETY AND OPERATING MANUAL. All-in-One blower/ vac/mulcher WG502E

4-GALLON MOBILE PARTS WASHER

Read these instructions before using and keep them available at all times!

T 5263 TEAMSHO S 220V-240V

10cm Desk Fan User Manual

Screw-in heater (EHK)

VOLUME UP STRAIGHTENING BRUSH

Operating instructions

Operation Manual. Read and follow the operating instructions and safety information before using for the first time.

Variable Temperature Digital Solder and Desolder Station

TTV 4500 / TTV 4500 HP / TTV 7000

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

PARTS OVERVIEW GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

POWERFORCE HELIX. Vacuum USER GUIDE 2110 & 2111 SERIES. (Model 2110 Shown)

FHA 1100 A1 Domestic Water Pump

V-ZUG Ltd. Range hood. Levante. Operating instructions

PROLUXE SALON STRAIGHTENING BRUSH

MPK-09CRN2 / MPK1-09CRN1 / MPK1-12CRN1 DE EN IT FR NL

TDS12.. Operating instructions

Mini oil filled radiator OR320-6

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

Instruction manual. Water treatment Boiler system D 30 L

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Transcription:

Revision A Date 23.11.2012 author NH This operating instruction is not subject to updating Air Blower 95001 1

This air blower is a quality product with special focus on high functionality, easy handling, safety and reliability. As technical work equipment this air blower is designed for use in industrial commerce and for operators that have been trained by qualified personnel to use technical devices / tools. Customer Care: Within the framework of our individual customer care we are well prepared to answer your questions regarding use and operation as well as regarding any possibly arising problems. Service and Maintenance: To maintain the high technical productivity and reliability of our air blower for many years we recommend regular inspection and maintenance. Our customer service provides optimal support which we offer within the framework our service and maintenance agreement. Please do ask for our quotation. Carl Kurt Walther GmbH & Co. KG Westfalenstraße 2 42781 Haan Germany Postfach 42 04 44 42404 Haan Germany Phone: +49 (0) 2129/567-0 Telefax: +49 (0) 2129/567-450 E-Mail: info@walther-praezision.de Internet: www.walther-praezision.de Contact: Application Engineering and Service Holger R. Figge Phone: +49 (0) 2129/567-591 Telefax: +49 (0) 2129/567-590 Mobile: +49 (0) 162/2090100 E-mail: hfigge@walther-praezision.de Please find further addresses and phone number of our contacts on our homepage www.walther-praezision.de Technical Service. 2

Table of Content 1 Table of Content 1 TABLE OF CONTENT... 3 2 GENERAL... 4 3 WARRANTY... 5 4 SAFETY INSTRUCTIONS... 6 5 PRODUCT DESCRIPTION... 8 5.1 INTENDED USE... 8 5.2 TECHNICAL DESCRIPTION... 8 5.3 TECHNICAL DATA... 8 6 INSTALLATION MANUAL... 9 7 OPERATING INSTRUCTION... 10 8 MAINTENANCE AND FUNCTIONAL TESTING... 11 9 TESTING... 12 10 STORAGE... 13 11 PLACING OUT OF OPERATION... 14 12 INDEX... 15 3

General 2 General This operating instruction includes any and all rules for operation, placing into operation and maintenance of the air blower. All details and notes in this operating instruction were prepared subject to the applicable regulations, the latest engineering stage of development as well as according to our long-term knowledge and experience. The translations of the operating instruction were carried out according to the best of knowledge. However, we exclude any liability for translation errors. The enclosed German version of this operating instruction shall be decisive. The actual scope of delivery may vary from the descriptions and drawings as provided here when it comes to special design, additional order options or due to latest technical changes. Please contact us for any questions. This operating instruction must be read carefully prior to any work on or with the device, in particular before any placing into operation! The manufacturer shall not assume any liability regarding defect and malfunction resulting from any non-observation of this operating instruction. The operating instruction must be kept absolutely close to the device and must be accessible for all persons working on or with the device It is not permitted to provide this operating instruction to any third party, any provision may result in damage claims if applicable. We reserve the right to further claims. Prior to placing the device into operation it must be checked for being free of defects and for working technically correct. The original version is in the German language. We reserve our right to technical changes on the product within the framework of improvement of the functional characteristics and further development. This operating instruction is our property. Any copying, use or notification to third parties is criminal and liable to prosecution (German Copyright Act against Unfair Competition, German Commercial Code). All rights reserved for the case of patent right issue (section 7, subsection 1 German Patent Law) or GM registration (section 5, subsection 4 GMG). 4

Warranty 3 Warranty The warranty is subject to: to the terms and conditions as agreed in the purchasing agreement and in the General Terms and Conditions of Deliveries and Services of C.K. Walther GmbH & Co. KG in the version as applicable on the date of execution of the purchasing agreement. Generally, wearing parts are excluded from any warranty. Typical wearing parts in the product range of C.K.Walther GmbH & Co. KG are e. g.: seals springs 5

Safety instructions 4 Safety instructions The application of this operating instruction does not release the operator from the observation of any applicable occupational safety regulation, e.g. the Operational Safety Regulation. The operator of the air blower must perform its duty of care by planning measures for ensuring a proper operation and by controlling implementation. Hazard Notes - No air blower is admitted for air cleaning of dirt particles on clothes, glasses, gloves or similar on the body. Despite nozzles formed to markedly reduce the risks and hazards when dealing with the energy source air, direct body contact must be avoided because severe injuries may occur. - When working with air blowers well fitting safety glasses must be worn (also by nearby persons) because chips or other coarse material are moved with much - The maximum admissible working pressure must never be exceeded (see Technical Data). - Never use oxygen, flammable gases or halogenated hydrocarbons as energy. - Check all connections and hoses for tight fit and serviceability. Loose hoses may be a risk of severe injury. - Prior to adjustment works, fault clearance and long-term non-use as well as maintenance works disconnect the air blower from the pressure source. - Air blowers must not be diverted from its intended use or rebuilt. Only use original equipment. Not recommended equipment has a risk potential - Do not use the device when it does not work properly or when it was damaged. Do not try to repair it on your own. The operator must in particular ensure that - the air blower is used only according to the intended use. - the air blower is operated in a perfect working condition. - persons with limited physical, sensory or mental abilities do not use the air blower unless when supervised and trained by an advisor. - any and all parts of the sets are kept out of the reach of children. The air blower is no toy. - the operating instruction is at all times available to the operating personnel in a complete and legible state. - the operating personnel is familiar with the safety notes and principle of operation of the air blower. - The nozzles may develop a very high noise level (90dB(A)). In general, for air-cleaning of blind holes or blowing against edges it is known that indefinable noise frequencies can occur that may damage the hearing. To prevent any such, ear protectors must be worn for long lasting works without interruption. - during the operation of the air blower so safety devices are removed and / or deactivated. 6

Safety instructions After finishing mounting and installation works of the air blower and prior to the placing it into operation the following points must be observed: Check again all screw connections for tight fit. Prior to placing the air blower into operation a functional testing must be carried out. 7

Product Description 5 Product Description 5.1 Intended Use - The air blower is intended for air-cleaning of objects and places difficult to access as well as blow drying of damp places. 5.2 Technical Description material: plastics - to avoid any negative influence on the material property (plastic) of the housing of the air blower, the air blower must not be cleaned with benzene or alcoholic cleaning agents. Similarly, when heavily oily it should be cleaned with water only. - Should damage occur on the plastic housing despite the observation of these notes the air blower must not be used further. Bursting or yielding of the thread on the nozzle connection is possible. 5.3 Technical Data The air blower can be equipped with various connections. These connections can be inquired at the manufacturer Walther-Präzision. The nozzles are designed in such way to provide a wide protection against improper use so that any excessive buildup of pressure is avoided when placed on skin. Nevertheless the blowing force is underestimated. Pressure is often unnecessarily increased for subjective reasons, this is not necessary. Working pressure: 5-6- bar Max. working pressure: 8 bar Operating temperature: -10 C bis +50 C Noise level: (measured in ca. 1m distance to the air blower) see table Inlet pressure Noise level 1 bar 70 db/a 2 bar 72 db/a 3 bar 74 db/a 4 bar 76 db/a 5 bar 78 db/a - the air blower is not intended for any other usage and technical values than indicated in the product description. 6 bar 80 db/a - If the air blower is used not according to the intended use and the respective technical values no safe operation can be ensured. - Regarding any and all personal injuries and damage to property resulting from any and all use not according to the intended use or to the technical values not the manufacturer but the operator of the air blower is responsible and liable 8

Installation Manual 6 Installation Manual The air blower must be integrated into a network under consideration of the general accident prevention regulation in such way that: - proper operation according to the operating instruction is possible. - any outer damage of the unit as well as of the moving parts is excluded After the mounting works are completed a functional testing according to the operating instruction is to be carried out both in depressurized and pressurized state. 9

7 To avoid any possibly life endangering injuries of the personnel and damage to the air blower during operation only the conditions of use as indicated under the point product description must be used. There are two alternatives for manual pick up Valve closed (no air flow) Valve open (air flows) 10

Maintenance and Functional Testing 8 Maintenance and Functional Testing Preventive Maintenance Measures The WALTHER- air blower must be handled in such way that any outer damage to the elements and to all moving parts can be excluded. Maintenance To always ensure the functioning of the air blower and therefore the protection of the operator a maintenance and functional testing must be carried out in suitable intervals depending on the operating conditions. The maintenance includes the following points: - A visual inspection regarding possible damage and soiling must be carried out - Soiling of the functional area (seal area, actuating elements) accessible from outside can be removed by simply wiping it off. - When parts are damaged, torn or corroded the air blower must be demounted and sent to the manufacturer for repair. Warning! When repair is carried out individually a pressure and leak test must be absolutely effected, this can also be carried out during the working process. The procedure and scope of this test is described under the section Testing. Warning! The manufacturer Walther-Präzision does not provide and expressly excludes any warranty for any repair not carried out by the manufacturer Walther Präzision. 11

Testing 9 Testing Description: Testing the fitting by immersion testing according to the following table values. Series air blower 2 bar absolute - Test assembly and test sequence air blower air blower water quench - Notes and Remarks: The holding time per test is 10 sec. Taking into account a leak rate of 10-2 mbar x l/s 3 gas bubbles with a diameter of 4 mm may escape in these 10 sec. After the testing the fitting must be dried in warm air as soon as possible. (Recommendation: 45 55 C, ca.30 min in air current, 2 h in static air, depending on the device) - Documentation: Testing must be documented by recording the test pressure, test fluid and name/date. 12

Storage 10 Storage The air blower must be stored in such way that no damage may occur to the air blower. The storing conditions of the air blower must be subject to the guidelines regarding the seals because the seals may alter by improper storage. The following points must be observed: - The air blower must be stored in a dry place. - For a safe conservation of the seals, the seals and thus the air blower should be stored in a dry place without any day light. 13

Placing out of Operation 11 Placing out of Operation At the end of the service life the air blower or its single parts must be disposed of in an environmentally sound manner and according to the legal requirements. For this purpose local public or private disposal firms should be commissioned. 14

Index 12 Index A air... 10 air blower... 2 C Contact... 2 Customer Care... 2 G General... 4 H Hazard Notes... 6 I Intended Use... 8 M manual pick up... 10 Max. working pressure... 8 N Noise level... 8 O Operating temperature...8 P particular...6 Placing... 14 S Safety instructions...6 Service...2 Storage... 13 T Table of Content...3 Test assembly... 12 test sequence... 12 translations...4 W Warranty...5 Working pressure...8 15