We offer ceramic radiant heaters and infra-red radiant tubes.

Similar documents
IT-KN 7-7 kw. Dimensions. Heat load / Output (kw) 7.0. Angle of installation 15 / 30 / 45 / 60. Gas consumption. natural gas (m 3 /h) 0.

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

AMBIRAD.... Vision Radiant Tube Heating Systems...

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

The Tube Heater Principle

"HC" AIRFLO. In-duct firing line burner

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

INFRARED HEATERS APPLICATIONS INFRARED HEATING

SECTION GAS-FIRED RADIANT HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

CATALYTIC EMITTER - An old idea in new clothes

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

Cumberland Heating Systems

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

Greater temperature control

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

PHYSICS OF FOIL HEAT GAIN/LOSS IN BUILDINGS

HEATXL RVS. Electric Infrared Heater

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

INFRARED RADIANT HEATERS

PUSHING THE LIMITS OF WHAT IS POSSIBLE

1 - High-velocity gas burners

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

FIRE IR SENSOR Flame Detection

Detroit Radiant Products Company MANUFACTURER OF GAS-FIRED INFRARED RADIANT HEATING EQUIPMENT SINCE 1955

Brant Radiant Heaters Limited MANUFACTURER OF GAS-FIRED INFRARED RADIANT HEATING EQUIPMENT SINCE 1965

L O S S C O N T R O L

PORTABLE HEATERS MCS GROUP.

SECTION AUXILIARY HEATER

Introduction. Craig Hale National Sales Manager. Advanced Radiant Systems, Inc. Fishers, IN. Signature Flight Support

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

SHP High Pressure Radiant Gas Brooder Series

PORTABLE HEATERS FOR PROFESSIONAL use

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Removing the moisture contents of coal using solar drying

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

LEARNING SPECIAL HAZARD DETECTION TYPES

'7 Infrared Drying and Curing Systems w4

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

DH-Direct Fired Poultry Farm Diesel Heater

Poultry Housing Tips Radiant Tube Heater Floor Heating Patterns Volume 17 Number 5 April, 2005

Brooders. Better Brooding for Your Chicks... Since 1924

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

"NP" & "RG" AIRFLO. In-duct firing line burner

DELTA-TE III. Nozzle-mix line burner

Solution of I Mid Term Steam Engineering 6ME5A

Physics. Mr Rishi Gopie THERMAL ENERGY TRANSFER

Testing Emission Source ITES Operating Manual OM

A. Product Data: Include rated capacities, furnished specialties and accessories.

Radical CPD BIM.

Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Copyright 2011 AIA MasterSpec Full Length 06/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CALCANA USA LTD.

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Waste/Multi Oil Boilers from Flexiheat

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

LOW NOx MODULATING GAS BURNERS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

PART NO. THROUGH THE ROOF VENT CAP

Gas heaters and convectors ROBUR

Installation, Operation and Service Instructions H RANGE STANDARD EFFICIENCY HIGH INTENSITY HEATERS

Heating with Wood. Part 2

2017 / 2018 //HEATING AND COOLING TECHNOLOGY

50% * Save up to. Better Equipped. to keep you working this Winter. off our range of heating products

Efficient Steam System Design

PART NO. COMBUSTION AIR TERMINATION CAP

Industrial infrared heater IR

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

advanced : technology

Series LV AIRFLO. In-duct firing line burner

Synergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION

Drying in series deserves the right control Dryers of the GDZ Series

25 Years IBS GmbH. Innovative and taylormade burner systems

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

PORTABLE HEATERS FOR PROFESSIONAL USE

FOR YOUR SAFETY. Applies to: Models RIH, RIHV, RIHVN, and RIHVL Gas-Fired High-Intensity Infrared Heaters. Models RIH/RIHV

Max Fire Box Users Guide

Trends for Radiant Tube Heated Strip Lines

Installation, Operation and Service Instructions HD RANGE SINGLE STAGE DIRECT SPARK HIGH INTENSITY HEATERS

INFRARED RADIANT TUBE HEATER

Incident Summary (II )

Transcription:

When considering the choice of a new energy-efficient heating system for halls, warehouses, workshops or greenhouses, we should definitely consider gas-powered radiant heating. State-of-the-art heating systems for largespace buildings are increasingly based on gas radiant heaters. Gas radiant heaters provide heat to objects and people by direct transfer of heat energy, without heat loss to the air. We can compare the heat emitted with the Sun's rays. Heat passes through the air without transmission losses and it is absorbed by people and objects in its path and the ambient air is heated in turn from the surface of these elements. Radiant heating eliminates the basic defect of convection heating systems, which is heating the upper parts of buildings, which are not used. Gas radiant heaters emit heat almost immediately after start up and therefore it is not necessary to preheat the area before. Gas radiant heaters can heat individual work-places or we can create separate heating zones without heating the entire hall. Gas radiant heaters can be powered by natural gas or LPG. Gas radiant heaters are particularly effective when used to heat buildings such as: production halls and warehouses, workshops, aircraft hangars, sports halls and large religious buildings. We offer ceramic radiant heaters and infra-red radiant tubes.

Ceramic infrared radiators work using flame less combustion of air-gas mixture on the surface of ceramic plate. As a result the plate achieves the temperature of 850 900 C. Energy emission is more intensive and the radiator become the spot source of heat. Falling on the surface, radiation is absorbed by the people present within its range. The radiator contains electro valve with double closure and its design protects against uncontrolled gas leakage. The combustion quality of properly set machines meets the requirements of environmental protection, safety and work protection regulations.

Ceramic radiators the highest quality, high-temperature ceramic plate, large ceramic radiant surface; radiator's construction is built with stable and anti corrosive materials; high-effective, made with aluminum screen which directs rays downwards; electronic control system. Ceramic radiator is a self-sufficient device, it doesn t require fumes exhaust through the chimney, it is a light device what guarantee the lower costs of assembly in comparison to other heating devices; Variety of applications buildings can be heated partly, in zones where people stay without the necessity of building division walls; Reliability of devices radiators were tested in order to guarantee high quality and proper operation. System advantages: Technological application Energy economy 30-60% High security level Lack of air movement, lack of dust in the heated room Heat is concentrated on the floor level, in the zone where people stay Short time of starting and immediate thermal effect Automatic regulation Heating and controlling in zone Law investment expenditure Simple service Simple and quick assembly SBC 6 SBC 8 SBC 10 SBC 12 SBC 16 SBC 12+12 SBC 30 A [mm] 595 780 970 1150 1520 1150 970 B [mm] 270 270 270 270 270 270 270 C [mm] 365 365 365 365 365 365 365 D [mm] 255 255 255 255 255 255 255 Model Number of tiles Heated area [m 2 ] Nominal force [kw] Gas consumption NG[m 3 /h] LPG[l/h] Electrical power supply SBC 6 6 35-45 8,6 0,86 1,13 230V-50Hz-25VA SBC 8 8 50-60 11,4 1,14 1,50 230V-50Hz-25VA SBC 10 10 55-65 14,3 1,43 1,88 230V-50Hz-25VA SBC 12 12 60-80 17,1 1,71 2,25 230V-50Hz-25VA SBC 16 16 80-100 22,8 2,28 3,00 230V-50Hz-25VA SBC 12+12 24 100-120 34,2 3,42 4,50 230V-50Hz-25VA SBC 30 30 125-155 42,8 4,28 5,63 230V-50Hz-25VA

Radiant tubes are modern devices designed for the heating of industrial and manufacturing halls. The radiant tubes works by burning the air-gas mixture inside the radiating tube, which as a result heats up to 400 C. The heat streaming directly from the source heats objects located in the zone of radiation. With the current radiant tube reflector, the heat is directed onto the floor of the hall, so the heating effect is felt in the lower areas of the buildings, which are most developed and utilized. The heaters warm people and objects without heating the air. This allows for the reduction of air temperature and maintains optimum comfort.

The radiant tube kit includes: radiating tube aluminized annealed steel type U or I ; gas solenoid valve equipped with double security; electronic control unit controls the work of the solenoid and the ignition burner; fan; differential pressure control of the motor; reflector to direct radiation downwards. Radiant Tubes are manufactured in two basic versions: the U- shaped and the I- shaped, which enables more efficient use in various configurations of buildings. The exhaust gases are discharged through a special exhaust pipe to the outside. Advantages of the radiant tubes: quick start-up and fast thermal effect; fuel saving up to 40%; lack of air movement and the means to limit the flow of dust inside the hall; the possibility of heating specific zones; exhaust fumes are discharged to outside; areas do not require additional ventilation; thermal comfort. Type Capacity [kw] Weight [kg] Length [m] Gas consumption NG[m2/h] LPG[l/h] Electric power[w] SBT 6 30 96 6,3 3,15 2,0 95 SBT 9 42 145 9,3 4,41 2,8 95 SBT 12 42 180 12,3 4,41 2,8 95 SBT 12i 30 93 12,3 3,15 2,0 95 SBT 18i 42 132 18,3 4,41 2,8 95