CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

Similar documents
VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

AMBIRAD.... Vision Radiant Tube Heating Systems...

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

RHC GAS FIRED HEATING COILS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

We offer ceramic radiant heaters and infra-red radiant tubes.

AMBIRAD. HEATI NG AND VENTILATION S OLUTIONS... Product Overview... AMBIRAD AIRBLOC NORDAIRNICHE BENSON

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Introduction. Craig Hale National Sales Manager. Advanced Radiant Systems, Inc. Fishers, IN. Signature Flight Support

Warm air heating equipment

RHC & RHCE gas fired heating coils

DF-IDF air handling units

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... DF / IDF Gas fired combined heating and ventilation ...

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

GARAGE / WORKSHOP INFRARED HEATERS

Gas-fired unit heaters for indoor installation

IT-KN 7-7 kw. Dimensions. Heat load / Output (kw) 7.0. Angle of installation 15 / 30 / 45 / 60. Gas consumption. natural gas (m 3 /h) 0.

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Radiant heating equipment

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

PREEVA air handling unit

... UDSA - UDSBD Gas fired unit heaters...

PT Radiant Heater Range

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

CATALOG: HVAC - Gas Space Unit Heating

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Heating Systems. An ideal temperature in every pig house

ELECTRIC HEATERS. Fireball Electric Heaters. 10,200btu HEAT OUTPUT. heating. 30,706btu HEAT OUTPUT. 9,600btu. sales hotline

Cumberland Heating Systems

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

AMBIRAD VISION SCHOOL HEATER KIT INSTALLATION MANUAL

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

LBF RANGE BALANCED FLUED WATER HEATERS

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Copper-Fin GAS-FIRED BOILERS

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Model VPT 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

BENSON.... Variante3 Fired Unit Heaters...

Max-3 Steel Shell Boiler

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

NOZ2. Multi-Directional Heating & Cooling Solutions

INSTALLATION AND OPERATING MANUAL. Vision VS Radiant

Saving energy comes naturally to us.

LARGE CAPACITY HEATERS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

THE BURNING ISSUE FOR BODYSHOPS

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

VPC Gas Cabinet Heater Range

Copper-Fin GAS-FIRED WATER HEATERS

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

BM2 patent NEW INFRARED OIL HEATER FIRE 45

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VSXUS INFRA-RED HEATERS

BENSON LINEAR RADIANT TUBE

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Residential Heating Boilers

MX RANGE PACKAGED STEAM BOILERS

Transcription:

CI/SfB 56.83 X Vision RADIANT TUBE HEATING SYSTEMS

Vision RADIANT TUBE HEATING SYSTEMS Introduction The new range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms of efficiency and the potential to reduce energy costs. The foundation of this exciting new development is a new high efficiency advanced burner. Features New advanced burner technology Choice of burner ratings from 15 to 50kW depending on model type All units are CE approved NO x emissions as low as 55ppm on certain models 40% lower than standard radiant heater Combustion occurs entirely within the firing tube. Not only does this reduce the size and weight of the traditional burner control housing but it also helps to reduce noise levels (as quiet as 47 db(a) 3m free field) New slim-line burner head provides a long evenly distributed flame that dramatically improves temperature distribution along the entire length of the heater, delivering a more even floor coverage The inclusion of a recuperative heat exchanger on RVSXE models (patent P308150GB), mounted adjacent to the burner housing, significantly increases thermal efficiencies up to 90% and enhances radiant efficiency above 55%. Model Range There are two Vision ranges: The standard RVS range, which is available in U tube, single linear and double linear models The high efficiency RVSXE range, with recuperative heat exchanger, which is available as a U tube model RVSA models are available on request (aluminised reflectors with no end caps). All models can be roof or wall mounted. RVS RVSLF RVSDL RVSXE

Benefits Easy to install and maintain On forced gas burner models all electrical wiring is contained at one end of the product, which is particularly time saving when installing single linear (RVSLF) heater models All units require straight forward annual maintenance Additional control at the touch of a button All models are compatible with Reznor SmartCom control systems. SmartCom units incorporate a host of features such as self-learning optimised start-up to ensure increased comfort and energy savings. Optimum economy and fuel savings The elimination of both distribution and standby losses coupled with high operational efficiencies at the point of use enable fuel savings of up to 65% compared with conventional heating systems Excellent radiant performance. More of the available heat generated is distributed to floor level thereby improving efficiency and reducing energy consumption High efficiency models are included on the Government s Energy Technology List and may be eligible for Enhanced Capital Allowances (ECA) SmartCom control panel Radiant black bulb sensor (Please refer to separate leaflet SmartCom Energy Management Control for full details.)

Vision RADIANT TUBE HEATING SYSTEMS Specification RVSXE model Flueing Units can be installed unflued or individually flued (including concentric flues to minimise building penetrations). Fresh air intake Fresh air can be ducted into the heat exchanger from outside the building to provide clean combustion air, required when there are contaminates in the atmosphere. Burner Burner ratings range between 20 and 50kW in 5kW increments.the new burner head located within the firing tube leg provides a very long flame with even heat distribution. NO x emissions are very low as low as 55ppm on certain models. Heat exchanger Mounted adjacent to the burner housing. Significantly increases thermal efficiencies up to 90% and enhances radiant efficiency above 55%. (Patent P308150GB). Control housing Burner controls are mounted within a chassis that incorporates hinged doors for ease of access for commissioning and maintenance. Turbulators Stainless steel spiral turbulators optimise tube temperatures by scrubbing the flue gases against the tube surface, maximising heat transfer and increasing radiant efficiency.

Standard U tube radiant heater Vision (RVSXE) Burner Burner Burner Vision improves temperature distribution along the entire length of the heater Tube finish CALCOAT tubes a high technology process that applies a tough, dense, highly emissive surface both inside and out that eliminates the need for painting. As a result CALCOAT ensures a long lasting surface that will not rust or flake, protects welds and maintains the highest of emissivity factors throughout the entire life of the heater. U bolts U bolt clamps for ease of installation and assembly

Vision RADIANT TUBE HEATING SYSTEMS Radiant Heating Working in the same way as the sun, radiant heat warms all solid objects and surfaces in its path through electromagnetic waves. Being mounted overhead, Reznor radiant heaters produce infrared heat that is directed downwards to low level by a reflector. Infrared energy passes inertly through the air, dissipating as heat upon contact with people and surfaces thus creating a comfortable, all-round radiant warmth at lower air temperature. This reduces wasteful heating of empty space and makes substantial energy savings over conventional boiler and air systems. Universal Application Radiant heating has traditionally been predominant in industrial and commercial buildings, especially where there are large, high bay areas or where there are a high number of air changes within the environment. Vision has been developed with these markets in mind and with a view to making radiant heating truly competitive within new smaller industrial and commercial buildings. Its application is universal including environments with high air change, frequently opened doors, or where there is a need for zonal heating in very large premises. The highly efficient performance of Vision provides greatly reduced running costs and improved capital payback, setting new industry standards. Vision Applications Aircraft hangars Automotive workshops and showrooms Factories Retail outlets Sports arenas and halls Warehouses Workshops Enhanced Capital Allowances (ECA) The Government s Enhanced Capital Allowance scheme actively encourages industry and commerce to reduce energy consumption by promoting the use of energy efficient equipment. With radiant efficiencies of above 55% and thermal efficiencies of up to 90% (reducing fossil fuel consumption). This symbol verifies that the product has been independently assessed and qualifies for the ECA scheme, an upfront tax relief enabling businesses that invest in energy-saving equipment to claim 100% first-year capital allowances against their taxable profits.

TECHNICAL DATA - All Models Gas Supply Electrical Supply Current rating External fuse rating Ingnition Connection 1/2 BSP internal thread 230 volt 1 phase 50Hz 1.0 amp max (inductive) 3 amp external Exhaust flue twin wall diameter 127 mm (5") Electronic programme start up with spark ignition Vision Standard U Tube Models (induced burner) RVSUT & RVSAUT Note: All technical details shown relate to both the RVSUT & RVSAUT models except for clearance distances as indicated SPECIFICATION Model RVS15UT4 RVS15UT RVS20UT RVS25UT RVS30UT RVS35UT RVS40UT RVS45UT RVS50UT Nominal gross heat input kw 15.8 15.0 19.5 23.5 29.5 36.0 40.0 44.0 48.0 Nominal gas rate per burner m 3 /h 1.5 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.6 Dimensional & weight data Length mm 2219 3417 4142 5066 6029 5709 5709 7471 7471 Bracket height mm 260 240 240 240 240 260 260 260 260 Bracket width mm 675 500 500 500 500 675 675 675 675 Total installed weight kg 41 43 50 60 70 92 92 121 121 Recommended mounting height range For mounting heights above or below those specified contact Reznor Design Office Horizontal m 4 to 5 4 to 5 4.5 to 7 5 to 8 5.5 to 9 6 to 10 6.5 to 11 7 to 12 7.5 to 13 Inclined / wall mounted m 3.5 to 4.5 3.5 to 4.5 3.5 to 5 4 to 5 4 to 6 4.5 to 6.5 5 to 7 5.5 to 8 6 to 9 Minimum clearance distance to combustible surfaces Model RVS15UT4 RVS15UT RVS20UT RVS25UT RVS30UT RVS35UT RVS40UT RVS45UT RVS50UT Above reflector VS models with end caps mm All models 180 Above reflector VSA models no end caps mm All models 280 Above burner & fan assembly flued mm All models 500 Beneath tubes mm 1500 1700 2100 To the sides mm 900 1000 1100 Horizontally from fan outlet unflued mm All models 1200 End of the heater to the wall mm All models 500 Vision Recuperative Heat Exchanger U Tube Models (forced burner) RVSXE Model RVSXE20UT RVSXE25UT RVSXE30UT RVSXE35UT RVSXE40UT RVSXE45UT RVSXE50UT Nominal gross heat input kw 20.0 25.0 32.0 36.0 40.0 44.0 49.5 Nominal gas rate per burner m 3 /h 1.9 2.4 3.1 3.4 3.8 4.2 4.7 Dimensional & weight data Length mm 4100 5900 7660 Bracket height mm All models 420 Bracket width mm All models 670 Total installed weight kg 75 102 130 Recommended mounting height range For mounting heights above or below those specified contact Reznor Design Office Horizontal m 5.5 to 8 6 to 9 6.5 to 10 7 to 11 7.5 to 12 8 to 13 8.5 to 14 Inclined / wall mounted m 4.5 to 6 5 to 6 5 to 7 5.5 to 7.5 6 to 8 6.5 to 9 7 to 10 Minimum clearance distance to combustible surfaces Model RVSXE20UT RVSXE25UT RVSXE30UT RVSXE35UT RVSXE40UT RVSXE45UT RVSXE50UT Above reflector mm All models 180 Above burner & heat exchanger assembly mm All models 500 Beneath tubes mm 2300 2500 To the sides mm All models 1300 Horizontally from heat exchanger outlet unflued mm All models 1200 End of the heater to the wall mm All models 700

Vision Standard Linear Models (forced burner) RVSLF & RVSALF Note: All technical details shown relate to both the RVSLF & RVSALF models except for clearance distances as indicated Model RVS15LF RVS20LF RVS25LF RVS30LF RVS35LF RVS40LF RVS45LF RVS50LF Nominal gross heat input kw 13.8 19.5 23.5 29.5 36.5 40.0 45.0 50.0 Nominal gas rate per burner m 3 /h 1.3 1.9 2.3 2.8 3.5 3.8 4.3 4.8 Dimensional & weight data Short length option Nominal metres 6 7 8 10.5 10.5 13.5 13.5 13.5 Total installed short length weight option kg 43 49 53 72 103 126 126 126 Long length option Nominal metres 8 10.5 10.5 12.5 13.5 16 16 16 Total installed long length weight option kg 53 72 72 84 126 147 147 147 Bracket height mm All models 390 Bracket width mm 315 470 Recommended mounting height range For heights above or below those specified contact Reznor Design Office Horizontal m 4 to 5 5 to 7 5 to 7 5 to 9 5 to 11 5 to 11 6 to 12 7 to 13 Inclined / wall mounted m 3.5 to 4.5 4 to 5 4 to 5 4 to 6 4 to 7 4 to 7 5 to 8 6 to 9 Minimum clearance distance to combustible surfaces Above reflector RVSLF models with end caps mm All models 150 Above reflector RVSALF models no end caps mm All models 280 Above burner mm All models 500 Beneath tubes mm 1500 1700 2100 To the sides mm All models 750 Horizontally from heater outlet unflued mm All models 1200 End of the heater to the wall mm All models 500 Vision Standard Linear Models (induced burner) RVSLI, RVSALI Note: For all dimensional, weight and clearance details please refer to Vision Standard Linear forced burner section detailed above Model RVS15LI RVS20LI RVS25LI RVS30LI RVS35LI RVS40LI RVS45LI RVS50LI Nominal gross heat input kw 15.0 19.5 23.5 29.5 36.0 40.0 44.0 50.0 Nominal gas rate per burner m 3 /h 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.8 Vision Standard Double Linear Models (induced burner) RVSDL & RVSADL Note: For clearance details please refer to Vision Standard Linear forced burner section detailed above Model RVS15DL RVS20DL RVS25DL RVS30DL RVS35DL RVS40DL RVS45DL RVS50DL Total nominal gross heat input both burners kw 30.0 39.0 47.0 59.0 72.0 80.0 88.0 100.0 Total nominal gas rate both burners m 3 /h 2.8 3.8 4.6 5.6 6.8 7.6 8.4 9.6 Dimensional & Weight Data Short length option Nominal metres 12 14 16 21 21 27 27 27 Total installed short length weight option kg 86 98 106 144 206 252 252 252 Long length option Nominal metres 16 21 21 25 27 32 32 32 Total installed long length weight option kg 106 144 144 168 252 294 294 294 Patent number: P308150GB Document reference number: GB/VS/124/0508 Reznor UK Limited Park Farm Road Folkestone Kent CT19 5DR United Kingdom Telephone: 01303 259141 Facsimile: 01303 850002 Email: marketing@reznor.co.uk Website: www.reznor.co.uk Reznor UK is a registered trademark of AmbiRad Limited. Because of continuous product innovation, AmbiRad reserves the right to change product specification without due notice.