PRE-INSTALLATION GUIDE

Similar documents
PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

Installation & Operation

DENTAL AIR SYSTEM. AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C International. Installation and Operation Manual

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy.

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Utility Room Accessories. Take your equipment s performance to the next level.

Vacuum Plumbing Layout Recommendations

User s and Installation Manual

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

RP, GP, XP Pro Series Installation Instructions

Read Only Document Not For Distribution

Installation Instructions Remote Blowers

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

PowerVac G Single to Twin Conversion Kit [ ]

VENTILATION FAN / LED LIGHT

Special Requirements For Health Care Facilities

WineZone Ceiling Mount Ductless Split 15

USER MANUAL/Installation Instructions LRV-4

Quest Power Electric Heat EHS 31 Pro

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

HUMIDITY SENSING BATH FAN

SF180 Installation Instructions

IN020 Rev F Page 1 of 8

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

MODEL CDB8 INSTALLATION INSTRUCTIONS

Installation Instructions

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Quest 105, Dry155, and 205 Dual

Owner s Manual Phoenix FireBird

RP / RPc Series Installation Instructions

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Quest Dry 105, 155, and 205 Dual

Quest Power Electric Heat EHS 62 Pro

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MODELS B1PA024, 030 AND 036

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Essential Utilities. Your practice depends on dental compressed air and vacuum. AirStar. STS. VacStar. Steadfast reliability for your peace of mind.

Model LF-310 Air Operated

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Owner s Manual for. PennStoker

Ergoline Affinity 500

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Dear Concessionaire,

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

IN014 Rev P Saber Way, Ward Hill, MA radonaway.com

Installation Manual CARBONATOR With Plain-Water Booster

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

APPLICATION DATA SHEET

IMPORTANT INSTRUCTIONS READ & SAVE

IN065 Rev C Page 1 of 8

Installation Instructions. Revision Date: 05/16/12

Integrated Ventilation System

RDT Refrigeration Book

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

Safety and Installation Instructions Model 1700

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

STERI-VAC CENTRAL SUCTION SYSTEM

Ergoline Open Sun 1050

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

745 Clark Ave. Bristol, CT Toll Free: Fax: General Air Dryer Installation Guidelines and Design Considerations

Downdraft Raised Vent

VetPro Solo Installation

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Please Read And Save These Instructions.

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

R E D I C O N T R O L S

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

HS Series Installation & Operating Instructions RadonAway

INSTRUCTIONS! DO NOT DISCARD!

Nominal Circuit Capacities: 9,000 12,000 18,000 & 24,000 Btuh units.

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

APPENDIX J ILLUSTRATIONS

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Installation Instructions

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Install Configurations

High Output Vacuum/Pressure Pump

VENTILATION FAN WITH LIGHT AND HEATER

HS Series Installation & Operating Instructions RadonAway

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

ECO1ZN3P, ECO2ZN4P ECO

Installation Instructions Induction Cooktop

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

FT1000S BASE FLIGHT-TYPE DISHWASHER

IMPORTANT INSTRUCTIONS READ & SAVE

Transcription:

DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS50, VS50H, VS80 & VS80H Model VS50 Model VS50H Model VS80 Model VS80H This VacStar Model is being installed: (AS CHECKED) VS50 VS80 VS50H VS80H Doctor: Address: Phone#: Dealer: Dealer Address: PRODUCT SPECIFICATIONS Electrical VS50 VS50H VS80 VS80H Voltage Rating 230 230 230 230 Voltage Min./Max. 205/253 205/253 205/253 205/253 Full Load Amps 16 16 26.8 26.8 Water Inlet Water Pressure (psi) 20-100 20-100 20-100 20-100 Flow Rate Per Pump (gal/min) w/ HydroMiser N/A 0.12 N.A. 0.18 Flow Rate Per Pump (gal/min) w/o HydroMiser 0.50 N/A 0.75 N/A Inlet Water Temperature ( F) 40-75 40-75 40-75 40-75 Power and Heat (@ 100% duty cycle) Watts per Hour 1,500 1,875 2,460 3,075 BTU per Hour 5,119 6,398 8,394 10,493 Vacuum Level Preset at Factory (In Hg) 10 10 10 10 Physical Characteristics Shipping Weight in pounds 160 170 200 210 Height x Width x Depth Dimensions in inches 22 x 28 x 16 25 x 28 x 16 22 x 28 x 16 25 x 28 x 16 All installations must conform to local codes.

PHYSICAL CHARACTERISTICS Model VS50 Model VS50H Model VS80 Model VS80H Height 21 inches (53 cm) Height 24 inches (61 cm) Height 21 inches (53 cm) Height 24 inches (61 cm) Width 28 inches (71 cm) Width 28 inches (71 cm) Width 28 inches (71 cm) Width 28 inches (71 cm) Depth 16 inches (41 cm) Depth 16 inches (41 cm) Depth 16 inches (41 cm) Depth 16 inches (41 cm) 16.00 16.00 16.00 16.00 21.00 24.00 21.00 24.00 28.00 28.00 28.00 28.00 Shipping Weight Shipping Weight Shipping Weight Shipping Weight 160 lbs. (73 kg) 170 lbs. (77 kg) 200 lbs. (91 kg) 210 lbs. (95 kg) SITE REQUIREMENTS 24V CONNECTIONS Electrical VS50 VS50H VS80 VS80H Min. Circuit Breaker Rating Wire Size AWG (Min. Gauge) Buck/Boost Transformer Ambient Temperature 2 ea. 15A or 1 ea. 30A 2 ea. 14 or 1 ea. 10 2 ea. 15A or 1 ea. 30A 2 ea. 14 or 1 ea. 10 #67002 #67002 (40-104 F 5-40 C) 40-104 F (5-40 C) 2 ea. 20A or 1 ea. 40A 2 ea. 12 or 1 ea. 8 #67002, 2 ea. 40-104 F (5-40 C) Important: Each pump should have a dedicated circuit panel. 2 ea. 20A or 1 ea. 40A 2 ea. 12 or 1 ea. 8 #67002, 2 ea. 40-104 F (5-40 C) Vacuum Pump Yellow 2 Brown 4 Orange 3 Connection to 24 V Switch Only Interconnect Cable Remote Switch for Future Use Use 18 Gauge, 4 Conductor, Interconnect Cable Between VacStar Pump and Remote Switch ELECTRICAL CONNECTIONS Figure 1 - Interior View 2 4 3 Connection without 24 V Switch 2 Yel 3 Org 4 Brn Interior Electrical Box Connections If voltage falls below the minimum 205 or maximum 253 during operation, a Buck/ Boost Transformer must be installed. See Product Specifications. All VacStars must be wired directly from an electrical box that complies with local electrical codes to the VacStar s Electrical Connections. See Figure 1. Green Black White Blue Red Pumps Right Left Power Leads (L1) Black (L2) White (L1) Red (L2) Blue CLASSIFIED MEDICAL ELECTRICAL EQUIPMENT WITH RESPECT TO ELECTRICAL SHOCK, FIRE, MECHANICAL AND OTHER SPECIFIED HAZARDS ONLY IN ACCORDANCE WITH UL-60601-1, CAN/CSA C22.2 NO.601.1 66CA Page 2

PLUMBING SITE REQUIREMENTS Plumbing VS50 & VS50H VS80 & VS80H Min. CFM @ 0" Hg 32 44 Air Exhaust with Hydromiser 2" schedule 40 pipe 2" schedule 40 pipe Overhead Plumbing Main Line Dia. Min./Max. ID in inches 1¼ to 1½" 1½ to 2" End Fitting 1" FNPT 1" FNPT Overhead Main Line 1/2" ID 1/2" ID Floor Plumbing Main Line Dia. Min./Max. ID in inches 1¼ to 1½" 1¼ to 2" End Fitting 1" FNPT 1" FNPT Branch Line Dia. Min./Max. ID in inches Note: Suction piping must slope at least a ¼ for each 10 feet of run towards the pump. Use PVC Schedule 40 or Copper Type M. 1 to 1½" 1 to 1½" Equipment Room Temperature The VacStar equipment must be used in a controlled temperature environment. Maintain equipment room temperature between 40 and 105 degrees Fahrenheit. Adequate forced ventilation must be provided across the unit by placing an appropriate exhaust fan opposite an equivalent air intake vent. The fan should be higher than the associated intake vent. Exhaust Vent Protection. VENTILATION REQUIREMENTS If the exhaust piping is venting to the outside of the building, precautions must be taken to protect the equipment room from weather elements and animal intrusion. This can be accomplished by using one of the three methods shown below. Shroud & Screen Screen Shroud & Screen Roof-Mounted Outside Vent Protection Wall-Mounted Outside Vent Protection Make sure to use the required pipe type for associated system Page 3

PLUMBING INSTALLATION SUB FLOOR INSTALLATION - The sub-floor plumbing layout shown below is the recommended layout for VacStar system installations and should be used whenever possible. Interior Wall Ceiling 2-Inch Exhaust/Vent Black Flex Tubing Junction Box Floor Sink See Note 1 1/2-Inch Diameter Riser Minumum Slope: 1/4 inch per 10 Feet Riser - See Note 2 45 Elbow Main Line From Dental Unit 1/2 Inch Riser 45 Y To Pump RISER to MAIN LINE DETAIL MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. See Notes 3, 4 & 5. Notes: 1. See Optional Drain Connections shown below. 2. 8-Foot Maximum Height from Main Line to pump. 3. Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. 4. Limit branches. Orient main line under junction box or cabinet. 5. When main line is 1-1/2" I.D. or larger, use 45 Y's and elbows only. 6. Long radius 90 elbows can be used as alternates to 45 elbows. All installations must conform to local codes. Page 4

PLUMBING INSTALLATION OVERHEAD INSTALLATION - The overhead plumbing layout shown below is the alternate layout for VacStar system installations and should be used only when unable to use the sub-floor plumbing layout. MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. 45 Elbow 1" Min Main Line 45 Elbow 1/2 Inch Riser 1/2 Inch Diameter 45 Y To STS Pump Minumum Slope: 1/4 inch per 10 Feet RISER to MAIN LINE DETAIL Interior Wall Ceiling 1/2-Inch Diameter Riser 10-Foot Maximum Height from Riser Trap to Main Line 2-Inch Exhaust/Vent Black Flex Tubing Junction Box Floor Sink Note: See Optional Drain Connections 1/2-Inch Riser To Main Line Dental Unit Note: Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. 1/2-Inch RISER TRAP DETAIL (Using 45 Elbows) CONNECTION DETAILS ALL INSTALLATIONS - 45 Elbow CLEARING AN OBSTRUCTION MAKING TURNS 45 Elbow MAIN LINE DO NOT use 90 elbows except where main line terminates at vacuum pump. Use only 45 elbows to make turns in main line. If piping is diverted to clear an obstruction, DO NOT MAKE A TRAP. DRAIN OPTIONS Direct connection to vented drain. No traps before vent. CLOSED VENTED DRAIN OR Indirect connection (Air gap) with a p-trap. 6 1-1/2 Inch P-Trap OPEN DRAIN PIPE Page 5

UTILITY ROOM Without Hydromiser With or without Air/Water Separator Typical for both VS50 and VS80 Vent vent to outside with 2 schedule 40 pipe Air/Water Separator WARNING: Condensation of Water will occur in vent piping. Avoid Accumulation of water in vent. Slope piping toward separator. Power Connection Water Suppy 1 / 2 copper tube terminate with 1 / 2 FNPT shut-off valve 32 Inches Maximum. 24 VAC Intake from Main Line terminate with 1 FNPT fitting Floor Sink Note: See Optional Drain Connections All VacStar vacuums comply with NFPA 99C level 3 requirements Page 6

UTILITY ROOM with Hydromiser Typical for both VS50H and VS80H If the existing drain is higher than the HydroMiser outlet, the HydroMiser must be mounted so that its outlet is above the drain. The HydroMiser can be installed up to 32 above the base of the VacStar. Order Kit PN 55087. Vent vent to outside with 2 schedule 40 pipe WARNING: Condensation of Water will occur in vent piping. Avoid Accumulation of water in vent. Slope piping toward separator. Power Connection Hydromiser Hydromiser Intake from Main Line terminate with 1 FNPT fitting 24 VAC Water Suppy 1 / 2 copper tube terminate with 1 / 2 FNPT shut-off valve 32 Inches Maximum. Floor Sink Note: See Optional Drain Connections Page 7

You can obtain more information about Air Techniques products by visiting our web site at www.airtechniques.com Additional installation information is available on our Authorized Air Techniques Dealer web site at http://dealers.airtechniques.com Air Techniques Inc. 1295 Walt Whitman Road, Melville, NY 11747-3062 Website: www.airtechniques.com East Coast: 1-800-AIR-TECH (1-800-247-8324) West Coast: 1-800-822-2899 VacStar and Hydromiser are trademarks of Air Techniques, Inc. 2008 Air Techniques, Inc. Part No. 55349, Rev. M April 2014