QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Similar documents
Room Temperature Controllers

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

1592P01. for liquids in piping DN

Duct Temperature Sensors

Frost Protection Thermostat

Room Temperature Controller

Room thermostat with 24-hour time switch and large LCD

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Output module (230 V)

Room thermostats with LCD RDD100..

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Multi line separator module

Input module, input/output module

Wall-mounted room thermostat with LCD

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Electronic timeswitch

Use. For 2-pipe fan coils

RVL479. Heating Controller. for use with a partner unit

Wireless room thermostat with LCD

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Flush-mounted room thermostats

Room thermostat with independent DHW control

Input module, input/output modules

Flush-mounted room thermostat

Room Temperature Sensors

Room thermostat with Auto Timer, independent DHW

Frost Units for air temperature monitoring

Mimic display driver, LED ribbon cable

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Semi flush-mount room thermostats

OH720, OP720, HI720, HI722

Room thermostats with LCD for wall mounting

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Interbases. Sinteso FDSB221, FDSB228, FDSB229

DM1131 / DM1133 / DM1134 Manual call points

FDOOT221, FDO221, FDT221

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDCW241 Radio gateway Mounting

for relative humidity and temperature

Room thermostat with Auto Timer, Option External Input

Room Temperature Controller

FDCL221-M Multi line separator module

Room thermostat with Auto Timer, Option External Input

RAB21 RAB21.1. For two-pipe fan coils

Indoor Air Quality Controller

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

QFM21... Duct sensors. Symaro. for relative humidity and temperature

for relative humidity and temperature

Semi flush-mount communicating room thermostats

Duct Temperature Sensors

Heating Element. Building Technologies HVAC Products

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDOOT241-A9-Ex Multisensor fire detector

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room thermostat with Auto Timer, Option External Input

Room Air Quality Sensors

Radio fire detection system

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Touch Screen Flush-mount Room Thermostats with KNX Communications

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Call stations and extensions

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Room thermostat with Auto Timer, Option External Input

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

ASA linear smoke detector

PRELIMINARY EDITION

District heating controller

District heating controller

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

FDBZ290 Air sampling smoke detection kit

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Differential pressure sensors

Room Temperature Sensor

FDBZ290 Air sampling smoke detection kit

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

XC10 Extinguishing control panels

Digital Room Thermostat for Heating Applications with 7-Day Time Program

FDM273 Radio manual call point Mounting

RVL480. Heating Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

THERMASREG TR 040 THERMASREG TR 060

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Room Temperature Controller

District Heating Controller

DT1101A / DT1102A / DO110xA Automatic fire detectors

RVL481. Heating Controller. including d.h.w. heating

Transcription:

QXA2100 Condensation monitor QXA2100 Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power. Application Monitors condensation build up in buildings with chilled ceilings or ventilation, air conditioning, and heating plants Prevents condensation on chilled ceilings Prevents condensation at critical points in HVAC plants or buildings (ducts, fans, etc.) Prevents condensation on surfaces Use as a condensation switch A6V10741072_en--_e 2018-07-31 Building Technologies

Functions With the sensing element, the condensation monitor records relative humidity close to the dew point (=100 % r. h.). The resistance of the sensing element raises sharply between 90...100 % r. h. The electronics switch the relay prior to reaching the dew point. For example, switching the relay (2-point output) has the following effect on chilled ceiling applications: 1. The cool output is switched off through valve position or controller until the condensation signal disappears. 2. Water flow temperature is increased immediately to a selectable value (e.g. 1 to 2 K) and then slowly lowered after the signal disappears. The specific control function is required on the controller for this application. SD Q11 Q14 Q12 Q14 Q11 Q12 Key SD Q... 95 100 Switching differential Relay contact output r. F. % 1542D01 Note The diagram shows the relay status when power is on. When power is off the relay contact Q11-Q12 is closed. The detector does not withstand continuous condensation. Technical design The device is planned for AC/DC 24 V power with potential free AC/DC 1...30 V changeover contact or with extension module AQX2000 for AC 230 V power with potential free AC/DC 12...250 V changeover contact. QXA2100 Housing with snap-on cover made of pure white, flame retardant thermoplastics with spring-loaded humidity sensing element, holding relay with changeover contact, connection terminals, and Pg 11 cable entry glands made of plastic. Key 1 Sensing element 2 Fixing screw with strap-on band 3 Terminal block 4 Nose of snap-on facility 5 Slot for lifting the cover with the help of a screwdriver 6 Connection label Siemens Condensation detector QXA2100 / A6V10741072_en--_e 2/10

The same as QXA2100, but with remote sensor head (fixed cable connection of 1 m) rather than a directly integrated sensor. View: Sensor head on the mounting side View: Sensor head front side 1 Sensing element 2 Tensioning strap 3 Connector cable 1 m to base housing AQX2000 The AQX2000 extension module consists of base, top section, and printed circuit board with lateral connection terminals. Note RXZ40.1 The AQX2000 extension module is not supplied anymore. The RXZ40.1 terminal cover is available as an option for the AQX2000 extension module. It provides protection against electric shock and keeps terminals free from dust and dirt. When fitting the terminal cover, ensure that it engages correctly. 1542Z02 Removal of terminal cover Siemens Condensation detector QXA2100 / A6V10741072_en--_e 3/10

Type summary Type Order number Designation QXA2100 S55770-T375 Condensation monitor. S55770-T376 Condensation monitor with offset sensor Scope of delivery a QXA2100 condensation detector or a condensation detector with offset sensor. a tensioning strap for pipe diameters of 10...100 mm. thermal conductive paste. mounting instructions. Accessories Type Order number Designation AQX2000 BPZ:AQX2000 Extension module *) RXZ40.1 BPZ:RXZ40.1 Terminal cover *) Not supplied anymore Equipment combinations All devices that can work with AC/DC 24 V power and the condensation signal from the potential free AC/DC 1...30 V relay changeover contact with the help of the AQX2000 extension module, with AC 230 V power, it can work the condensation signal from potential free AC/DC 12...250 V relay changeover contact. Notes Engineering Mounting Condensation detector QXA2100/ The AQX2000*) extension module is operated with AC 230 V power. It provides AC 24 V power for the condensation detector and the condensation signal on the potential free AC/DC 12...250 V relay changeover contact. *) not available any more Pipe mounting with tensioning strap (pipe diameter 10...100 mm) Surface-mounting on walls or ceilings with 4 screws The condensation monitor performs its function only if the humidity sensing element assumes the same temperature as the surface to be protected against condensation. Please note: Apply a thin layer of thermal conductive paste on the mounting surface Mount at the coldest spot of the chilled ceiling (plant) Mount on the water inlet pipe on water-cooled chilled ceilings Note Protect the sensing element against aggressive chemicals and dirt, since this can adversely affect the proper operation of the monitor and significantly shorten its life. The condensation detector is supplied with mounting instructions. Mounting AQX2000 extension module AC 230 V Top hat rails EN 60 715 TH 35-7.5 Wall mounted (with the help of screws) Maximum cable length to condensation detector: 20 m Siemens Condensation detector QXA2100 / A6V10741072_en--_e 4/10

Installation Caution! Electrical voltage Electric shock Work on electrical installations may only be carried out by qualified electricians or by instructed persons working under the guidance and supervision of a qualified electrician, in accordance with the electrical regulations. Terminal cover RXZ40.1 must be used when using the AQX2000 extension module outside a closed panel. Caution! Electrical wiring can loosen from the terminals Fire hazard or risk of injury from electrical shock or short circuiting Strain relief required on AC 230 V terminals. Fix wiring with cable bindings (see image below) to the tabs in the housing base. 1542Z03 Commissioning A functional test can be conducted if needed, by exhaling slowly onto the sensing element several times to simulate condensation. Note Power lines AC 230 V Disposal Do not expose the sensing element to tap water as this can cause electrolytic corrosion. Local regulations regulate sizing and fusing of power lines. Power lines must be fused in the extension module AQX2000 with strain relief (see Engineering). The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local, applicable regulations Siemens Condensation detector QXA2100 / A6V10741072_en--_e 5/10

Technical data QXA2100, Power supply G (G+), G0 (G ) Functional data Output Q11, Q12, Q14 Connections Protective data Environmental conditions Directives, standards Operating voltage SELV/PELV AC/DC 24 V ±20 % Frequency 50/60 Hz Power consumption Max. 1 VA External fuse Transformer with secondary current limit of max. 10 A or external secondary current fuse with max. T 10 A non-renewable fuse or max. C 13 A circuit breaker Required under all circumstances Switching point on increase in humidity 95 ±4 % r. F. Switching differential (fixed) Ca. 5 % r. h. Response time in static air 80 to 99 % r. h. Max. 3 min 99 to 80 % r. h. Max. 3 min Relay output Current range at AC/DC 24 V Starting current at AC/DC 24 V Switching capacity External fuse Mechanical Electrical connections Screw terminals for 1.5 mm 2 Potential free changeover contact 0,02...1 (1) A 5 A for 20 ms min. AC/DC 1 V, 1 ma max. AC/DC 30 V, 1 A External fuse at max. T 4 A nonrenewable fuse required strap-on band for pipe Ø 10...100 mm Housing IP 40 per EN 60 529 Protection class III as per EN 60 730 Transport to Climatic conditions Temperature Humidity Mechanical conditions Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions IEC 60 721-3-2 Class 2K2 25...+60 C <95 % r. h. Class 2M2 IEC 60 721-3-3 Class 3K5 5...+50 C 5...95 % r. h. (noncondensing) Class 3M2 Product standard Automatic electronic controls for household and similar use EN 60730-1 EU conformity (CE) A5W00004359 1) RCM conformity CB1T3302en_C1 1) EAC compliance Eurasian compliance Materials and colors Housing Thermoplastic, pure white, flame retardant Dimensions (weight) Including packaging QXA2100 0.126 kg 0.126 kg 1) Documents can be downloaded at http://siemens.com/bt/download. Siemens Condensation detector QXA2100 / A6V10741072_en--_e 6/10

AQX2000 Power L, N Operating voltage AC 230 V ±10 % Frequency 50/60 Hz Power consumption Max. 4 VA External fuse External secondary current fuse with max. T 10 A non-renewable fuse or max. C 13 A circuit breaker Required under all circumstances Inputs Outputs Status signal input D, GND Contact voltage Contact current Voltage output G, G0 Rated voltage range Frequency at AC 24 V durable Relay output Q11, Q12, Q14 Rated voltage range Rated current range Switching capacity DC 37 V (SELV/PELV)) 13 ma AC 24 V ±20 % (SELV/PELV) 50/60 Hz max. 1 VA Potential free changeover contact Not suitable for connecting to SELV/PELV circuits Line fusing requires strain relief AC/DC 12...250 V 0,01...6 A Min. AC/DC 12 V, 10 ma Max. AC/DC 250 V, 6 A 1500 V Connections Protective data Environmental conditions Directives, standards Insulation against power (L, N) External fuse External secondary current fuse with max. T 6 A non-renewable fuse or max. C 6 A circuit breaker Required under all circumstances Electrical connections Screw terminals for Max. 2 x 1.5 mm 2 or 1 x 2.5 mm 2 Wire length to QXA2100, Max. 20 m Degree of protection of housing With terminal cover and wall-mounting without top hat rail Safety class to EN 60 730 Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport to Climatic conditions Temperature Humidity Mechanical conditions IP30 to EN 60 529 device suited for use with equipment of safety classes I and II IEC 60 721-3-3 Class 3K5 5...+50 C <85 % r. h. Class 3M2 IEC 60 721-3-2 Class 2K2 25...+60 C <95 % r. h. Class 2M2 Product standard Automatic electronic controls for household and similar use EN 60730-1 EU conformity (CE) CE1T1542xx 1) RCM conformity CB1T3302en_C1 1) EAC compliance Eurasian compliance Materials Housing Terminal cover ABS + PC ABS + PC Dimensions (weight) Including packaging 0.2 kg 1) Documents can be downloaded at http://siemens.com/bt/download. Siemens Condensation detector QXA2100 / A6V10741072_en--_e 7/10

Connection diagrams Internal diagrams QXA2100, G (G+) Operating voltage AC 24 V or DC 24 V G0 (G ) System neutral Q... Potential free changeover contact AC/DC 1...30 V n/c Do not use AQX2000 G G0 D GND L N Q12 Q11 Q14 1542G02 G Operating voltage AC 24 V G0 System neutral D, GND Status signal input DC 37 V for potential free changeover contact of the QXA2100, L, N Operating voltage AC 230 V Q... Potential free changeover contact AC/DC 12...250 V Connection diagram F1 Condensation detector QXA2100 / U1 AQX2000 extension module AC 230 V Siemens Condensation detector QXA2100 / A6V10741072_en--_e 8/10

Dimensions QXA2100 AQX2000 Dimensions in mm Top hat rails Siemens Condensation detector QXA2100 / A6V10741072_en--_e 9/10

Issued by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2015 Delivery and technical specifications subject to change 10/10 Siemens Condensation detector QXA2100 / A6V10741072_en--_e