ENERVEX MFD MECHANICAL FIREPLACE DAMPER

Similar documents
MFD Mechanical Fireplace Damper

ENERVEX MDF MODULATING DAMPER

ENERVEX ADC100 DRAFT CONTROL

ADC150 Automatic Draft Control

ENERVEX RSV CHIMNEY FAN

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

ENERVEX GSV GREASE FAN

ENERVEX IPVB INLINE POWER VENTER

IPVB EC inline power venter

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

EBC 12 Modulating Fan Control

RS chimney fan for gas and oil applications

MEC 18 Mechanical Exhaust Control

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RS Chimney Fan for Gas & Oil Applications

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

EW 40 Wireless Fan Control

ENERVEX GSV GREASE FAN

RS Chimney Fan for Gas & Oil Applications

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

ELECTRONIC FIREPLACE DAMPER

External Roof-mounted Power Vent System

ELECTRONIC FIREPLACE DAMPER

RSIB Power Venter

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

ENERVEX BEF BOX VENTILATOR

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

ENERVEX TDF POWER VENTER

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

ENERVEX BEF BOX VENTILATOR

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Installation Instructions

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Integrated Ventilation System

SECTION (15820) - AIR DUCT ACCESSORIES

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

GSV Grease Fan

Installation Instructions Remote Blowers

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

INSTALLATION INSTRUCTIONS

Installation Manual PS-225 & PS-275

INSTALLATION INSTRUCTIONS

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

GB162 Concentric Horizontal Vent Kit

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Installation Instructions VITOTRONIC 200

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

OWNER S GUIDE COMMERCIAL POWER VENTER KITS USED IN CONJUNCTION WITH FLUE DAMPERED COMMERCIAL WATER HEATERS TABLE OF CONTENTS

Crown Boiler Company

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Installation Manual PS-200 & PS-201

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Requirements for Models:

EEMAX SERIES-TWO WATER HEATERS

EUTECTIC EC-10DV Series

WAIWELA SERIES-TWO WATER HEATERS

2 PREPARE THE OPENING

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

INSTALLATION INSTRUCTIONS

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

T4398A,B Precision Electric Heating Thermostat

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SECTION AIR DUCT ACCESSORIES

Multistory Fireplace & Exhaust System

TO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

CLe-series Dishwashers

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

AVANI Grinding Booth

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Mighty Venter Power Vent System

Pellet Stove. Flex Pipe. Appliance Connector

Transcription:

ENERVEX MFD MECHANICAL FIREPLACE DAMPER Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E467733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@enervex.com www.enervex.com

UL File E467733 This symbol shows that the ENERVEX MFD Mechanical FIreplace Dampers are listed in the US and certified for Canada under Underwriters Laboratories Inc. file no. E467733. IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION. PROPER JOINT ASSEMBLY IS ESSENTIAL FOR A SAFE INSTALLATION. FOLLOW THESE INSTRUCTIONS EXACTLY AS WRITTEN. CHECK SECURENESS OF JOINTS UPON COMPLETION OF ASSEMBLY. Symbol Legend The following terms are used throughout this manual to bring attention to the presence of potential hazards, or to important information concerning the product. DANGER: Indicates an imminent hazardous situation which, if not avoided, will result in death, serious injury or substantial property damage. WARNING: Indicates an imminent hazardous situation which, if not avoided, may result in personal injury or property damage. How to use this manual This installation manual does not contain any system design documentation. System design documentation is available from any authorized ENERVEX representative. Accessories, fans, and variable frequency drives are not covered by this manual. Please refer to these component s individual manuals. TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK OR INJURY TO PERSONS, OB- SERVE THE FOLLOWING: 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed on the front of the manual. 2. Before servicing or cleaning the unit, switch off at service panel and lock service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards. 4. Follow the appliance manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers ASHRAE), and the local code authorities. 5. This unit must be grounded. 2

Content 1. PRODUCT INFORMATION 1.1 Function...4 1.2 Shipping...4 1.3 Warranty...4 1.4 Components...4 2. SPECIFICATIONS AND DIMENSIONS 2.1 Dimensions and Capacities...5 3. MECHANICAL INSTALLATION 3.1 Actuator and Cover...6 3.2 Location...6 4. ELECTRICAL INSTALLATION 4.1 General...7 4.2 Wiring of a Gas Fireplace with a Damper...8 5. STARTUP AND CONFIGURATION 5.1 Set Up...9 5.2 Sequence of Operation...9 6. MAINTENANCE 6.1 Cleaning...9 3

1. PRODUCT INFORMATION 1.1 FUNCTION The ENERVEX MFD is a low profile, automated fireplace damper. It is for use only in conjunction with an ENERVEX ADC100 control and RS model chimney fan as part of the EcoDamper System. It prevents excess heat from escaping through the chimney when the fireplace is not in use. The MFD is designed for chimney top installations and is for use with gas fireplaces only. The MFD is powered by a 120 or 24 VAC actuator. The actuator is interlocked to the control so it only operates when the fireplace is in use and the fan is running. When there is a call for heat from the fireplace, the ADC100 control begins its operational sequence to open the damper and start the chimney fan. Once the damper opens and there is sufficient draft in the chimney, the control releases the gas valve for fireplace operation. The actuator has two endswitches to prove damper position (open or closed) and is equipped with the Enerdrive fail safe system to open the damper in the event of an electrical or mechanical failure. The damper is rated for temperatures up to 575 o F (300 o C). The damper is sized to provide sufficient clearance between the damper blade and the fan inlet when open. The MFD is constructed of 18 gauge, type 304 stainless steel. System installation must conform to the requirements of the authority having jurisdiction. When required by the authority having jurisdiction, the installation must also conform to the NFPA31, NFPA54 or NFPA211. All electrical wiring must be in accordance with the requirements of the authority having jurisdiction or, in absence of such requirements, with the National Electric Code, NFPA 70. 1.2 SHIPPING Damper, actuator, cover and hardware are shipped as a unit. * If other components are shipped, they will appear as separate items on the packing list. 1.3 WARRANTY 2-Year Factory Warranty. Complete warranty conditions are available from ENERVEX, Inc. 1.4 COMPONENTS Components of the MFD are listed below: a. Actuator / Acuator Cover b. Stop Flange c. Fan Adapter d. Collar e. Damper Blade a c d e b Fig. 1 4

2. SPECIFICATIONS AND DIMENSIONS 2.1 DIMENSIONS AND CAPACITIES Fan Model RS009 and RS012 Chimney Size 6" 8" 10" 11" 12" 13" 14" 16" in 5.87 7.87 9.87 10.87 11.87 12.87 13.87 15.87 Ø A mm 149 200 251 276 302 327 352 403 iin 15.60 15.60 15.60 15.60 15.60 15.60 15.60 19.70 BxB mm 396 396 396 396 396 396 396 500 Dimensions in 15.75 16.75 17.75 18.25 18.75 19.25 19.75 22.80 C mm 400 425 451 463 476 489 502 579 in 2.11 2.27 2.44 2.52 2.61 2.69 2.77 2.94 D mm 54 58 62 64 66 68 70 75 Fan Model RS014 and RS016 Chimney Size 8" 10" 11" 12" 13" 14" 16" 18" 20" in 7.87 9.87 10.87 11.87 12.87 13.87 15.87 17.87 19.87 Ø A mm 200 251 276 302 327 352 403 454 505 iin 19.70 19.70 19.70 19.70 19.70 19.70 19.70 23.30 24.50 BxB mm 500 500 500 500 500 500 500 592 622 Dimensions in 18.80 19.80 20.30 20.80 21.30 21.80 22.80 25.60 27.20 C mm 477 503 516 528 541 554 579 650 691 D in 2.27 2.44 2.52 2.61 2.69 2.77 2.94 3.11 3.27 mm 58 62 64 66 68 70 75 79 83 5

3. MECHANICAL INSTALLATION 3.1 ACTUATOR AND COVER Before installing the MFD on the chimney, a power cable should be wired to the actuator (See Ch. 4) and the actuator cover should be secured. Use 4-conductor cable (min. 18 AWG) with a weatherproof jacket such as rubber or silicone. Install a weatherproof cable connector on the side of the actuator cover to prevent water ingress to the actuator. Use (6) of the included sheet metal screws to secure the actuator cover to the MFD. Once secure, apply a bead of silicone around the seams of the cover. SHEET METAL SCREWS (2) ON TOP SIDE (4) ON BOTTOM SIDE CABLE CONNECTOR Fig. 2 3.2 LOCATION Mount the MFD outdoors at the top of a steel chimney. Slide the collar of the MFD into the steel chimney until the damper rests on the stop flange. Sheet metal screws may be installed around the collar into the chimney for additional support. Once the MFD is secured, place the RS fan on the adapter. Use the mounting holes on the fan base as a drill template to make one mounting hole in each corner of the adapter. Use bolts and locking nuts to secure the fan to the MFD. RS FAN MFD STEEL CHIMNEY Fig. 3 6

4. ELECTRICAL INSTALLATION 4.1 GENERAL DANGER Turn off electrical power before servicing. Contact with live electric components can cause shock or death.! Verify voltage of actuator before connecting to a power supply. Acuator will run on either 120VAC or 24VAC. Wire that actuator for 2 wire/ 2 position operation as shown in Fig. 4 (120 VAC) and Fig. 5 (24 VAC) below. The actuator should be set for clockwise (CW) rotation and should fail to 90 o (MFD will open). Verify settings of the actuator before wiring. CONNECTION OF 120 VAC ACTUATOR CONNECTION OF 24 VAC ACTUATOR 120 VAC 24 VAC Fig. 4 Fig. 5 7

4.2 WIRING OF A GAS FIREPLACE WITH A DAMPER The MFD must be interlocked to an ENERVEX control. When used with a gas fireplace as part of the EcoDamper System, both a RS Chimney Fan and MFD will interlock with the ADC100 control as shown below. Power to the actuator must be supplied externally. Interlock the damper with the control board via terminals 27 and 28 as shown below. The Normally Open and Common terminals of the actuator endswitches should connect to the damper prove terminals (29 and 30). Complete system wiring details are shown in the ADC100 Control Installation Manual. ADC 100 XTP 26 27 28 Fig. 6 8

5. STARTUP AND CONFIGURATION 5.1 SET-UP Once the MFD has been installed, verify operation and rotation of the damper. The end of the damper rod is notched to indicate position of the damper blade. As the actuator opens the damper, the notch will indicate movement from 0 to 90o in the clockwise (CW) direction. If the damper does not operate correctly when power is supplied or if it rotates the wrong direction, verify wiring as shown in Ch. 4 of this manual. 5.2 SEQUENCE OF OPERATION See the Ch. 5 of the ADC100 Control Installation Manual for the sequence of operation of the EcoDamper System. 6. MAINTENANCE AND TROUBLESHOOTING 6.1 CLEANING Clean the MFD periodically at the same time the fan and/or chimney are cleaned. Damper should be cleaned with a cloth or rag. Check for and remove any debris that may be blocking the damper opening or chimney. 9

ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@enervex.com www.enervex.com