ACOUSTICAL DESIGN OF THE CONCERT HALL OF PÉCS CONFERENCE AND CONCERT CENTRE

Similar documents
AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS

THE ROOM ACOUSTIC DESIGN OF THE GUANGZHOU OPERA HOUSE

Acoustic Study of the Manuel de Falla Auditorium: Design Evolution and Acoustic Simulation

o Rear HVAC columns (Priority 1: Item 3) the rear ceiling area: be more dead for the organ and traditional music. (Priority 2: Item A)

The Acoustical Performance Analysis of Bilkent Amphitheater: Proposal for Acoustical Renovation

Lecture 18 Auditorium Acoustics

Power Amplifiers. Equalizers

Acoustics in open-plan offices A laboratory study

SPEECH PRIVACY DISTANCE IN 3 OPEN-PLAN OFFICE LAYOUTS: COMPUTER MODELLING AND SIMULATION APPROACH

Optimum Room Acoustic ComfortTM (RACTM) can be achieved by using a selection of appropriate acoustic descriptors

New Generation Loudspeakers

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Lindsey Beane. Executive Summary

AFMG. Design for Speech Intelligibility Using Software Modeling. Stefan Feistel, Bruce C. Olson AHNERT FEISTEL MEDIA GROUP

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

A Survey Study of Today s Monitoring Conditions

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES

Shape the Design with Sound Performance Prediction

Acoustics & Beam Steering Technology. Media Infrastructure Architect

U of I Borah Theater. A Performance Space. Michael Joseph Scott Shores. Site Location

Magneplanar 20.7 Instruction Manual

FAN WALL Technology. Product

THE COMPARISON OF THE RESULTS OF A FULL SCALE EVACUATION TEST TO THE CALCULATION METHOD OF HUNGARIAN REGULATIONS AND TO THE PATHFINDER SOFTWARE

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

Music Sculptures of Glass and Gold

AUDITORIUM SEATING SERIES CONFERENCE AND LECTURE HALL SEATING SERIES TS CUSTUM DESIGN

Signal Corps Recording: Room Analysis and Correction

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

The cooling capacity of the Thermo Active Building System combined with acoustic ceiling

Grand Auditorium of the Maison De La Radio By AS Architecture Studio

Low-noise fans are not a product of chance

Recent BRANZFIRE enhancements and validation

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

THE TIVOLI THEATRE. by John F. Allen

Room Acoustic Design in Open-Plan Offices

Typologies of Hybrid Ventilation in Schools

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Corn drying experiments by pilot dryer

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

CYS National Annex to CYS EN :2002

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

TEST REPORT No. EN-2160/057/15-098/15

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Aaron Geoffrey Kelsey

Using BIM model for Fire Emergency Evacuation Plan

Magneplanar 3.7i Instruction Manual

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Room Acoustics, PA Systems and Speech Intelligibility for Voice Alarm Systems using the example of the Cruise Center Steinwerder

Sound absorption coefficient Equivalent sound absorption area Sound absorption coefficient Sound absorption class

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

Fire Risks of Loviisa NPP During Shutdown States

Thermal Comfort with Convective and Radiant Cooling Systems

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

Magneplanar 1.7i Instruction Manual

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Laboratory study of the effects of green roof systems on noise reduction at street levels for diffracted sound

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM

FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

THREE DIMENSIONAL SLOPE STABILITY

Loudspeaker Test. Report

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Fire safety engineering applied to high-rise building facades

QUANTIFICATION OF TONAL PENALTIES IN ENVIRONMENTAL NOISE ASSESSMENTS

A study of radiant cooling for a room with daytime application in tropical climate

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

Case Study 1 Underground Car Park

HARRY RANSOM HUMANITIES RESEARCH CENTER

TABLE OF CONTENTS WHY KLIPSCH? KI SERIES TRACTRIX HORN SUBWOOFERS SPECIFICATIONS

Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Compact Horn Subwoofers

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

Ceiling air diffuser INDULTHERM INDULTHERM-e

D Implementation of a DEMO system related to Smart Fault Management in LV network (normal/storm conditions)

Senior Thesis Presentation

Performance. Placement In A Cabinet. The BeBop can be placed horizontally or vertically within a cabinet.

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Setting up Studio Monitors

Analysis of the Design of an HVAC System in a Public Building

Transcription:

ACOUSTICAL DESIGN OF THE CONCERT HALL OF PÉCS CONFERENCE AND CONCERT CENTRE András Kotschy and Attila B. Nagy Kotschy and Partners Ltd., Álmos vezér u. 4., Törökbálint, Hungary bandi@kotschy.hu Abstract The Pécs Conference and Concert Centre is a new building complex in southern Hungary built on the occasion of Pécs being one of the three Cultural Capitals of Europe in 2010. It consists of a large concert hall in its core surrounded by section halls, rehearsal rooms as well as ballet and other dance rooms. It hosts the Pécs Symphonic Orchestra, but will be used also for conferences and other social events, theatrical performances and pop/rock music concerts. The concert hall was designed in a cooperation of two consulting companies. This paper presents the design of this concert hall. The hall is a modified shoebox-shaped hall with asymmetric layout, two level balconies. Most surfaces are covered with wooden panels, the walls are equipped with pyramid shape diffusers and there is a canopy above the stage consisting of 7 individually moveable parts. During the detailed design phase two different room acoustical modelling software were used in parallel for the evaluation of the acoustic design. Altogether six different hall configurations were examined (configuration for symphonic orchestra, opera, rock music, rehearsal, banquet and conference). These configurations differ in the setting of the stalls that can be raised (slanted) or lowered to be flat and horizontal, the setting of the orchestra pit that can be covered and also raised to give an extension to the stage, the curtains around the stage and the occupancy of the seats and of the stage. In all cases the spatial distribution of the main acoustical parameters (reverberation times, early decay time, clarity, strength, lateral efficiency and stage parameters were determined and optimized. In order to have reliable absorption value for the chairs, both empty and occupied, laboratory measurements were carried out. The results of these measurements together with the simulation results of both software are shown and evaluated. 1. Introduction On the occasion of being one of the three cultural capitals of Europe in 2010, the leaders of Pécs, a city in southern Hungary, have decided to have a new concert hall and conference centre built. The complex, that is to be opened in December, 2010, is called the Pécs Conference and Concert Centre. It consists of a large concert hall in its core with section halls, rehearsal rooms as well as ballet and other dance rooms surrounding it. In order to achieve excellent acoustics in the concert hall, the detailed design was carried out in a cooperation of two acoustic consultants, Mr. A. Chr. Gade (Gade & Mortensen Akustik A/S) 1

who had already been involved in the tender design phase as well, and Mr. A. Kotschy (Kotschy and Partners Ltd.). The two consultants have access to different modelling software (Odeon and CATT), and although both software performed very well in earlier Round Robins (see [1] and [2]), this cooperation seemed to be a great opportunity to compare them in a real situation, by analysing the Pécs Concert Hall in different configurations. Altogether six different configurations were examined (configuration for symphonic orchestra, opera, rock music, rehearsal, banquet and conference). These configurations differ in (1) the setting of the stalls that can be raised (slanted) or lowered to be flat and horizontal, (2) the setting of the orchestra pit that can be covered and also raised to give an extension to the stage, (3) the curtains around the stage and the occupancy of the (4) seats and of the (5) stage. In all cases the spatial distribution of the main acoustical parameters (reverberation times (T30), early decay time (EDT), clarity (C80), strength (G), lateral efficiency (LFC, LF)) and stage parameters (STearly, EDTstage) were determined and optimized. The results of these simulations were discussed in [3], the reverberation times are shown here as well. At the submission of that paper the type of seats were already chosen, but there was no data available on their absorption coefficients. Laboratory measurements were carried out in order to determine these data, both for empty and occupied chairs, and the authors also had the opportunity to perform basic room acoustical measurements in the empty hall before the installation of the chairs. In the following the results of these measurements are shown and evaluated. 2. The design of the concert hall 2.1 Basic layout of the concert hall The concert hall is a modified shoe-box shaped hall with an asymmetric layout and two level balconies. The volume is app. 13000 m3, the maximum extents are about 42 22 18 m (length width height). The hall seats altogether 1000 people, the stage is designed to have enough place for large symphonic orchestra and choir. The walls and balcony fronts are covered with wooden panels, and the walls are equipped with pyramid shaped diffusers of different sizes. Above the stage there is a canopy consisting of 7 individually moveable parts. The architect's model of the concert hall from the final design phase is shown in Fig. 1, and a photo of the almost finished concert hall without the seats is shown in Fig. 2. Figure 1. Architect's model of the concert hall of the final design phase 2.2 Acoustical studies The basis for the simulations was a three dimensional architect s drawing, that was adopted in different ways to suit each modelling software's needs. Two typical room acoustical model views are shown in Fig. 3. All configurations were analyzed with both software. Being the acoustically most demanding configuration, the symphonic orchestra setting was examined more thoroughly than the others: all combinations of 6 source and 61 receiver positions (6 of which on the stage) were verified. The main attributes of the different settings are given in Table 1. Beside these, the curtains around the stage and the occupancy of stage were changed. As the most popular parameter for de- 2

Odeon 1985-2009 Licensed to: Gade & Mortensen Akustik A/S scribing the acoustics of the hall, the spatial average of the predicted reverberation times of the different settings are shown in Fig. 4. Figure 2. The concert hall without the chairs October, 2010 Figure 3. Model view of symphonic concert settings (left, CATT Acoustic, Kotschy and Partners Ltd.) and of banquet settings (right, Odeon, Gade & Mortensen Akustik A/S) TABLE 1. Main properties of different settings for the room acoustical simulations Setting Pit area Stalls Occupancy Symphony Extended stage Raised All seats occupied Opera Orchestra pit Raised All seats occupied Rock Extended main floor Raised All seats occupied Conference Extended main floor Flat Main floor seats occupied, balconies full Banquet Extended main floor Flat Tables and chairs on main floor, balconies empty Rehearsal Extended stage Raised All seats empty 3

3.0 2.8 2.6 T30 [s] 2.4 2.2 2.0 1.8 1.6 Symphonic Opera Rock Conference Banquet Rehearsal 1.4 1.2 1.0 125 250 500 1000 2000 4000 Frequency [Hz] Figure 4. Spatially averaged predicted reverberation times of the different settings 3. Absorption of the chairs Unfortunately, at the time of the design, there was no decision yet regarding the type of the chairs, therefore we had to use a typical absorption data recommended by Beranek [3] for occupied seats, and an average data for the unoccupied case (medium upholstered concert hall chairs). In June, 2010 laboratory measurements of the seat absorptions were performed according to the MSZ EN ISO 354:2003 standard. The chairs of the hall and a picture taken during the measurement of occupied seats are shown in Fig. 5, the measurement results and the previously used data by Beranek are given in Table 2. It can be seen that despite the quite heavy upholstering, the chair absorption is much lower than expected, both occupied and unoccupied. Figure 5. Seats (left) and measurement of chair absorption (right) TABLE 2. Absorption coefficients (α) of seating with and without audience (in percents) Frequency 125 250 500 1000 2000 4000 Beranek's data for occupied seats 62 72 80 83 84 85 Medium upholstered concert hall chairs 56 64 70 72 68 62 Measured audience absorption 40 45 40 60 75 60 Measured seat absorption 20 35 30 40 50 55 4

4. Measurements in the empty hall In the beginning of October, 2010, basic room acoustical measurements were carried out in the hall before the installation of the chairs. An omnidirectional loudspeaker for mid and high frequencies was used together with a subwoofer to cover the whole frequency range from octaves of 63 Hz up to 4 khz. Alltogether 8 source-receiver arrangements were measured. The measured reverberation times are shown in Fig. 6, and the averaged results are given in Table 3. Results of different measurement positions show good agreement. 4.5 4.0 T30 [s] 3.5 3.0 2.5 2.0 Meas. 1 Meas. 2 Meas. 3 Meas. 4 Meas. 5 Meas. 6 Meas. 7 Meas. 8 1.5 1.0 63 125 250 500 1000 2000 4000 Frequency [Hz] Figure 6. Measured reverberation times in the empty hall, without chairs TABLE 3. Average of the measured reverberation times (empty hall, without chairs) Frequency [Hz] 63 125 250 500 1000 2000 4000 Averaged T30 [s] 2.5 2.9 4.1 4.2 3.9 3.5 2.8 5. Expected reverberation times The measurement results shown above are promising if we take into account the additional absorption that will be introduced with the chairs. However, in the lowest frequency bands the reverberation times are somewhat lower than expected, the reason for which is not yet clarified. There are two main assumptions: the resonator effect of the pyramid diffusers on the sidewalls and the resonator effect of the ventilation blow-in grids on the floor, with a large cavity behind it when the stalls are raised. As the pyramids were designed in a way that their filling can be modified and thus they can be hardened up, the reverberation time can be fine tuned later on. By combining the reverberation times of the empty hall with the absorption data of the occupied seats, a rough estimate can be made on the expected acoustics of the hall. The estimated reverberation times for fully occupied and empty halls (without modification of the diffusers) are given in Table 4. 5

TABLE 4. Rough estimate on the reverberation times in the hall with all seats installed Frequency [Hz] 125 250 500 1000 2000 4000 Empty hall 2.4 2.7 2.9 2.5 2.2 1.9 Fully occupied hall 2.1 2.5 2.6 2.2 1.9 1.8 6. Summary During the detailed design phase of the concert hall of the Pécs Conference and Concert Centre we have used two different room acoustical modelling software to evaluate the acoustical design. At this phase there was no absorption data available on the chairs to be installed, therefore a typical recommended data were chosen and used. During Summer of 2010 laboratory measurements were carried out on the selected seats and their absorption were determined for both empty and occupied case. Later on room acoustical measurements were also performed in the empty hall before the installation of the chairs. The results of the simulations and the recently performed measurements are shown in this paper. The measurement results are promising, however, a fine tuning (increasing) of reverberation times in the lower frequency range might be necessary. The reason for the low reverberation time values is not yet clarified. REFERENCES [1] Bork, Ingolf. "A Comparison of Room Simulation Software The 2nd Round Robin on Room Acoustical Computer Simulation. Acta Acustica, Vol. 86, 2000, pp 943-956. [2] Bork, Ingolf. "Report on the 3rd Round Robin on Room Acoustical Computer Simulation Part II: Calculations. Acta Acustica United with Acustica, Vol. 91, 2005, pp 753-763. [3] Nagy, A.B., Kotschy, A., Gade, A. Chr., Johannessen, H. "Room acoustical modelling differences and their consequences. Proceedings of Internoise 2010 Conference, 13-16 June, 2010, Lisbon, Portugal [4] Beranek, Leo L, Takayuki Hidaka. "Sound absorption in concert halls by seats, occupied and unoccupied, and by the hall's interior surfaces. J. Acoust. Soc. Am. Vol. 104, 1998 6