UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Similar documents
Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

CROWN YEARLY PROPERTY SCHEDULE

LEASEHOLD YEARLY PROPERTY SCHEDULE

New Construction Fire Inspection Process

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Sheetz Inc. Fire Protection Service Guidelines

Self Inspection Program

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Types of Detection. Fusible Link Detection - Most Common

MCCMH MCO Policy FIRE SAFETY IN RESIDENTIAL SETTINGS Date: 5/04/11. Definitions

Equipment ATA 12 April 2016

WHEA FSE inspections.

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Water Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures

ELEVATOR RESCUE PROCEDURE

Final EC Inspection Report 03/2010

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

Model Policy On Portable Fire Extinguishers (Ontario Version)

Winnipeg Fire Department Fire Prevention Branch

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

Checklist For Life Safety

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

2010 Fire Log Fire Log. Annual Fire Safety Report

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Facilities Management

Fire Protection in the Mining Industry. Garry Kwok Board Member

The blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.

MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Attention Seawall and Dock Contractors

GUILFORD COUNTY SCHOOLS

EC 5.10 FIRE PREVENTION MANAGEMENT

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

GENERAL AREAS OF INSPECTION

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

CURTISS-WRIGHT CONTROLS INTEGRATED SENSING (CAGE CODE: 03972).

Basic Vehicle Fire Protection Manual

MASTER PLAN KICK-OFF Open House #1A, April 28, 2015

Checklist For Building Inspection & Fire Safety

a) Establishment of emergency procedures to be followed at the time of an emergency;

WLAC Facilities Committee Meeting. September 18, 2017

Policies, Practices, & Procedures

CENTRAL STATE HOSPITAL PLAN PLANT OPERATIONS UTILITIES MANAGEMENT PLAN

DIVISION 21 FIRE SUPPRESSION

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Austin Independent School District Police Department Policy and Procedure Manual

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire/Life Safety Policy

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Fire Sprinkler Plan Submittal Form

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Resolution Plan for GI-AP1000-IH-01 Internal Fire Safety Case Substantiation.

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Fire Drill Requirements Group E Occupancies

Appendix A. Reference Evapotranspiration (ETo) Table.

Prefunctional Checklist

Osceola County Department of Fire Rescue and Emergency Medical Services

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Established /10/2015. Doran Pruisner Dan Wood

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

Lauzon Life Safety Consulting

UNIVERSITY. Facilities Management

Subject: Hazardous, Universal, and Non Hazardous Waste Accumulation Site Management

5.07 Air Replenishment Systems

DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement. Fire Procedures

OHS WORKPLACE INSPECTION (1) SCHEDULE AND RATINGS

Design & Construction Standards, Revised January

WINNIPEG FIRE PARAMEDIC SERVICE FIRE PREVENTION BRANCH

Laboratory Fume Cupboards

26 of 128 9/23/2014 9:25 AM

F&S Control of Hazardous Energy Program

PORTABLE FIRE EXTINGUISHERS

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

HUDSON VALLEY COMMUNITY COLLEGE BUILDING EMERGENCY ACTION PLAN FOR OUTSIDE EMERGENCY ASSISTANCE: DIAL 911 TO REACH THE SARATOGA CTY POLICE & FIRE

WLAC Facilities Committee Meeting. May 15, 2017

INITIAL FIRE SAFETY ASSESSMENT

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

CHART PERUVIAN TECHNICAL STANDARDS

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Oct. 19, 2017

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

SOUTHEND CARELINE ANNUAL REPORT

Transcription:

Revision No.: 3 Page 1 of 6 I. PURPOSE This policy establishes the steps required for performing the monthly fixed systems inspections and the semi-annual systems testing. Fixed systems include; wet chemical kitchen hoods and special gaseous protection (halon, carbon dioxide and clean agents). II. PERSONNEL AFFECTED Fire Safety Coordinators and Fire Safety Inspector II Fire Protection Service Company Medical Center Facilities River Campus Facilities Eastman School Facilities Information Technology III. DEFINITIONS Clean Agents: Electrically non-conducting, volatile or gaseous fire extinguishant that does not leave a residue upon evaporation 1. Examples include Sapphire, Novec, etc. IV. RESPONSIBILITIES The Fire Safety Coordinator or Fire Safety Inspector II performing the testing is responsible for following the proper procedures and contacting the building representative (if applicable) when scheduling the testing as a courtesy notification. For the semi-annual inspections and tests, the Fire Safety Staff will meet approximately one month prior to the testing month with the fire protection service company to establish the schedule for testing. Physical testing for the systems is performed by a licensed contractor and completed in February and August each calendar year. The vendor provides their own inspection forms and the Fire Marshal s Office maintains proof of the inspections. V. PROCEDURES KITCHEN HOOD SIX MONTH TESTING A. Obtain the special instructions for each system. Instructions are located in the Fixed Systems Instruction Book (EHS main door reception area) or electronically on F:/fire/fixedsystemsinstructions. B. The Fire Safety Coordinator or Fire Safety Inspector II will contact Public Safety Dispatch to advise them of the testing on the kitchen system for that building and by-pass the fire alarm panel per disconnect/reconnect procedure for the specific fire alarm panel. 1 Definition in National Fire Protection Association 2002 Standard on Clean Agent Fire Extinguishing Systems

Revision No.: 3 Page 2 of 6 C. The vendor will disable the wet chemical system release feature; it is not a requirement to discharge the system during the six month test. Remove the previous inspection tag and fusible links from the manual release station. D. The vendor will replace the fusible links. Take the used links and seal tie them to the manual pull station. For the August test, place the test link with the other used fusible links. E. The vendor will trip test the system. In February, the system is tripped using the manual station and in August the system is tripped using a test fusible link. This ensures both means of activation are tested each year. F. When the system is tripped, verify that all electrical and/or fuel supplies (gas) are shut off. Verify that make-up air fans shut down (if applicable). Refer to the fixed system instructions for specifics on each system. G. To reset the systems, restore electrical power and/or fuel supplies to the appliances. Refer to the fixed system instructions for specifics on each system. Have facilities reset and fire shutters (if applicable) and the vendor will relight pilot lights on any appliances. H. If the system passes inspection; the vendor will place a new tag on the manual pull station with the links. The vendor will date, initial and indicate on the back of the tag that the test was done and outcome (pass). If the system fails for any reason, the vendor will place a RED tag on the system. I. The Fire Safety Coordinator or Fire Safety inspector II will contact the kitchen supervisor and advise them of the outcome of the test. J. Reset and restore the fire alarm system. Contact Public Safety Dispatch and advise them that testing is completed for that building and to treat all alarms per alarm protocol. K. The Fire Safety Coordinator or Fire Safety Inspector II will complete a work order for any deficiencies found during the test. Place a copy of the work order with the test from the vendor for follow-up. The Fire Safety Coordinator will coordinate any retests of the system. SPECIAL GASEOUS SYSTEMS SIX MONTH TESTING A. Obtain the special instructions for each system. Instructions are located in the Fixed Systems Instruction Book (EHS main door reception area) or electronically on F:/fire/fixedsystemsinstructions.

Revision No.: 3 Page 3 of 6 B. The Fire Safety Coordinator or Fire Safety Inspection II will contact Public Safety Dispatch to advise them of the testing on the gaseous system for that building and by-pass the fire alarm panel. C. The vendor will disable the gaseous system release feature; it is not a requirement to discharge the system during the six month test. Remove the previous inspection tag from the system. D. In February, the vendor will do liquid level checks of the tanks and battery load testing for the release panels on halon/clean agent systems. Carbon Dioxide system tanks are weighed. E. In August, the vendor will check tank liquid levels, weigh tanks and load test batteries in addition with trip testing the system. Smoke detectors, heat detectors, pull stations and other system devices are tested in August to satisfy the annual device testing requirement. F. Reset the system release panel (if applicable) before restoring the system. G. If the system passes inspection; the vendor will place a new tag on the system tank(s). The vendor will date, initial and indicate on the back of the tag that the test was done and outcome (pass). If the system fails for any reason, the vendor will place a RED tag on the system. H. The Fire Safety Coordinator or Fire Safety Inspector II will contact the person responsible for the area that the system covers and advise them of the outcome of the test. I. Reset and restore the fire alarm system. Contact Public Safety Dispatch and advise them that testing is completed for that building and to treat all alarms per alarm protocol. J. The Fire Safety Coordinator or Fire Safety Inspector II will complete a work order for any deficiencies found during the test. Place a copy of the work order with the test from the vendor for follow-up. The Fire Safety Coordinator will coordinate any retests of the system. FIXED SYSTEMS MONTHLY INSPECTIONS A. In addition to the test month, the fire safety coordinator or Fire Safety Inspector II will perform a monthly check of each fixed system. Use the monthly inspection form (Appendix A) for guidance in completing the inspections. B. The Fire Safety Coordinator or Fire Safety Inspector II doing the inspection will date, initial and indicate the outcome of the monthly check (i.e. OK, dirty links, etc).

Revision No.: 3 Page 4 of 6 C. Complete a work order for any deficiencies noted during the inspection and attach a copy with the monthly check form. VI. REFERENCES NFPA 12 Standard on Carbon Dioxide Extinguishing Systems VII. NFPA 12A Standard on Halon 1301 Fire Extinguishing Systems NFPA 17A Standard for Wet Chemical Extinguishing Systems NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems APPENDICES/FORMS Kitchen Monthly Inspection Form (Appendix A) Special Gaseous Monthly Inspection From (Appendix B) VIII. REVISION HISTORY Date Revision No. Description 5/6/11 New Initial development of policy 8/22/11 1 Updated Section V and Section VI 10/26/11 2 Updated Section VII 11/2/2014 3 Review and up date

Revision No.: 3 Page 5 of 6 Appendix A MONTHLY INSPECTION 20XX System Location Inspector Nozzle caps are in place, undamaged & intact Fusible links are clean and have little or no grease buildup System components have no obvious physical damage Extinguishing system components are in their proper locations No cooking equipment has been added or existing equipment moved Nozzles are aimed at cooking surfaces they protect Manual actuators are not obstructed Month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Date Tamper indicators and seals are intact Maintenance/Inspection tag or certificate is in place Pressure gauges are in operable range applicable) NOTES (if

Revision No.: 3 Page 6 of 6 Appendix B MONTHLY INSPECTION System Location Inspector 20XX Nozzles are in place, undamaged & intact System components have no obvious physical damage No alterations have been made to the room being protected Month Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Date Doors are self-closing/close automatically and positive latching for agent discharge Maintenance/Inspection tag or certificate is in place Pressure gauges are in operable range Indicate liquid level reading (cm) Indicate pressure gauge reading (psi) NOTES