Version 1.0. Plumbers Handbook. Scan code for details & installation instructions

Similar documents
Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owner s Guide and Installation Instructions Commercial Storage Tank

Owner s Guide and Installation Instructions Gas Domestic Indoor Water Heater

7 Year Warranty 1 RHEEM 4 STAR GAS STORAGE WATER HEATER FEATURES WHY CHOOSE RHEEM GAS STORAGE HOT WATER? , 135 & 170L

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

RHEEM CONTINUOUS FLOW GAS HOT WATER YEAR WARRANTY ENERGY L/MIN GAS HOT WATER THAT NEVER RUNS OUT. factor COMES ON STEADY, HOT AND STRONG INSTALL A

RHEEM DOMESTIC HOT WATER

Owner s Guide and Installation Instructions Electric Domestic Water Heater

Owners Guide and Installation Instructions Gas Domestic Indoor Water Heater

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

RHEEM DOMESTIC HOT WATER

RHEEM DOMESTIC HOT WATER

Owner s Guide and Installation Instructions Stainless Steel Electric Domestic Water Heater

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions Air Sourced 310 Heat Pump Water Heater

Owner s Guide and Installation Instructions Commercial Stainless Steel Storage Tank

Owners Guide and Installation Instructions

Operation / Installation Manual

OWNER S MANUAL SOLAR WATER HEATERS

Owner s Guide and Installation Instructions

Streamline. Open Circuit SOLAR WATER HEATER OWNER S MANUAL AND WARRANTY / INSTALLATION INFORMATION. Solahart Industries Pty Ltd ABN

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

RAYPAK HOT WATER & HEATING

Owner s Guide and Installation Instructions

Owner s Guide and Installation Instructions

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Owner s Guide and Installation Instructions Rheem Commpak CP02-CP06 Commercial Hot Water Systems

Owner s Guide and Installation Instructions Rheem Tankpak Series 2 Commercial Hot Water Systems

Owner s Guide and Installation Instructions Rheem Commpak CP21-CP36 Commercial Hot Water Systems

The Offer. Hot Water Solutions Offered in - Natural Gas - Electric - LPG

DUX WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

RAYPAK HOT WATER & HEATING

economy environment engineering excellence Advanced Commercial Hot & Warm Water Solutions

Owner s Guide and Installation Instructions

Operation Installation Manual Rinnai Split Solar Hot Water Systems

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

Operation / Installation Manual

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

DUX WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

Owner s Guide and Installation Instructions

Owners Guide and Installation Instructions Commercial Air Sourced Heat Pump Water Heater

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

Operation / Installation Manual

Hot Water South Australia

Owner s Manual. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater 135ZB4N / 135ZB4P 170ZB4N / 170ZB4P

INSTALLATION MANUAL Roof Mount Solar Hot Water System

HOT WATER. decisions guide

Installation Manual. HOTFLO (EHFA/EHFD) Series. Mains Pressure Vitreous Enamel Electric Storage Water Heater

Owner s Guide and Installation Instructions

Installation Instructions Air Sourced 310 Heat Pump Module

Owners Guide and Installation Instructions Rheem HS Series

Soak in the Sunshine. Solar Hot Water

DUX WATER HEATERS GAS HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

Operation & Installation Manual

Operation & Installation Manual

Owner s Guide and Installation Instructions

RHEEM CONTINUOUS FLOW GAS WATER HEATERS

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Models: GHF4135N GHF4170N

Installer s Guide IMPORTANT INFORMATION Read This Document First On completion, sign and leave with owner

Models: GHF4135N GHF4170N

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

25 per cent of energy used in the home is used to heat water.

IT S NOT JUST SOLAR IT S SOLAHART

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

WATER. 12 page of what s hot this winter! BONUS! BONUS! Buy any Rheem Metro continuous flow hot water unit and get a bonus safety pack *

COMMERCIAL & INDUSTRIAL

HOT WATER SYSTEMS.

Hot Water South Australia

DUX WATER HEATERS ELECTRIC HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

CONTENTS. HOUSEHOLDER - We recommend you read pages 3 to 44. The other pages are intended for the installer but may be of interest.

Combined electric boiler and domestic hot water store

Owner s Manual. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater 170ZN / 170ZL

COMMERCIAL SOLAR SOLUTIONS

Operation / Installation Manual

The Offer. Hot Water Solutions Offered in - Natural Gas - Electric - LPG

INSTALLATION MANUAL Ground Mount Solar Hot Water System

COMMERCIAL & INDUSTRIAL

Installation/Operating Instructions. MODELS Bosch 17e Bosch 21e Bosch 25e Bosch 26e INSTALLATION MANUAL

2009 Rheem Builder Solutions.

DUX WATER HEATERS ENVIRONMENTAL HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

Transcription:

2017 Version 1.0 Plumbers Handbook

To receive updates of the Rheem Plumbers Handbook register at rheem.com.au/trade-promotions How to Download a QR Code Reader to your Mobile Device Open your mobile app store (App Store, Google Play, Windows Marketplace, etc.) Search for QR code reader. Check out the list of QR code readers for mobile phones to find the right one for you. Simply download the QR code reader to your phone, open it and you are ready to scan the codes that appear in the Rheem Plumbers Handbook. 2

Contents Installation - Checklist General 4 Electric Water Heaters/Heat Pump 5 Gas Water Heaters 6 Solar Water Heaters 7 Hot Water Recirculation Systems 8 Anode Selection & Water Supplies 9 Water Connections 11 Pipework and Pipe Sizing 14 Specific Applications 15 Electric Storage Models Gas Storage Models Gas Continuous Flow Models & Accessories Solar Models Heat Pump Models 17 45 65 91 111 3

Installation Checklist General Water Heater position Read the Installation Instructions, to familiarise yourself with the unit the water heater must be installed, operated and maintained in accordance with the Owner s Guide & Installation Instructions and local state regulations. Water heaters must be installed and serviced by a qualified person. Keep the tank vertical at all times during transport and installation. Not applicable to solar thermosiphon tanks or Stainless Steel water heaters. Locate close to point of use or the most frequently used hot water outlet: Closer to the most often used tap will help reduce running costs. Minimising the length of hot water pipework reduces the time taken for hot water to reach the tap, heat loss and water wastage. Leave headroom of approximately one water heater height to allow anode inspection and replacement (storage water heaters and hot water storage tanks). Not applicable to Stainless Steel water heaters. Ensure controls can be easily operated. Ensure serviceable parts such as TPR (temperature pressure relief) valve are accessible. Ensure rating label/data plate can be easily read. Ensure service access covers are easily removable. For OUTDOOR storage water heaters: Must be installed on a level plinth 50mm above surrounding ground. Gas storage units must be installed up against a wall or rigid vertical support via the brackets provided. DO NOT place in direct contact with concrete that is less than 2 months old and not fully cured as this may attack the metal coating of the jacket. A moisture barrier between the two surfaces should be used in this instance. 4

Installation Checklist Electric Water Heaters/Heat Pump Location Water heaters installed in roof spaces local authorities have regulations regarding such installations, so check with your local authorities. Ensure the front covers, thermostats and elements can be removed for service. Installation Standards & Safety The water heater is supplied with a thermostat and a overtemperature cut-out and a combination temperature pressure relief valve (TPR). These devices MUST NOT be tampered with or removed, except for authorised service. The water heater must not be operated unless each of these devices is fitted and in working order. Operation of the over-temperature cut-out indicates a possibly dangerous situation. Only reset the control after the cause of its operation has been determined and any fault corrected. The water heater must be installed By a qualified person In accordance with the Installation Instructions and in compliance with Standards AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulations. Safe Tray Where property damage could occur in the event of a leak, the water heater must be installed in a safe tray Safe tray construction, installation and draining must comply with AS/NZS 3500.4 and local codes/regulations; check all relevant requirements before installing. 5

Installation Checklist Gas Water Heaters A flue of up to 150mm internal diameter must be 25mm clear of combustible materials such as timber walls and cupboards. A flue exceeding 150mm internal diameter requires clearances of 75mm from unprotected surfaces and 50mm from protected surfaces. Outdoor gas water heaters (all types) must have minimum clearances from the flue terminal to certain building features such as openable windows/doors and to fences/walls. Refer to AS/NZS 5601.1 for these clearances. Leave clearance to allow removal of the burner assembly if required. Leave adequate clearance on all sides for ventilation and safety and ensure flue terminal and air inlet are free from any obstruction (Gas storage and Continuous Flow). Ensure the combustion air supply is not likely to be contaminated with substances that are corrosive or would become corrosive after passing through a flame. Outdoor storage models must be installed against a wall or rigid vertical support. Outdoor models must have free and balanced airflow at both the air intake and flue outlet. Indoor water heaters require correct ventilation - check AS/NZS 5601.1 for requirements Gas Continuous Flow The high gas consumption of these water heaters often necessitates larger diameter gas supply pipe. Undersized pipe will affect performance and hot water capacity. Size the gas supply pipe using the MJ rating marked on the appliance. Large capacity (27L/minute) Continuous Flow water heaters may, due to their gas consumption, require greater clearance distance from doors and windows check AS/NZS 5601.1 requirements. 6

Installation Checklist Solar Water Heaters The correct type of solar water heater is to be selected for the area. Consideration must be given to whether freeze protection is required and to the chemistry of the water to be supplied to the water heater. For a split system, consideration must also be given to the position of the collectors in relation to the solar storage tank. There are limitations on both the maximum length of the solar hot and solar cold pipes and the maximum height between the storage tank and the collectors. Refer to the installation supplied with the product. The collectors must be installed in a shade free position. The surrounds should be checked for higher buildings or trees which may cause shade at other times of the year and for small trees which may grow and shade collectors in the future. The installation must comply with the requirements of either AS/NZS 3500.4 or AS/NZS 3500.5:2012 Section 3 (for a Class 1a or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements. The installer must ensure the structural integrity of the building is not compromised by the solar water heater installation and the roof structure is suitable to carry the full weight of the collectors and frame (if one is installed). If in any doubt of the construction or the condition of the roof, the roof should be suitably strengthened. Consult a structural engineer. Maximum performance is achieved with an orientation facing true north. Always check for true north using a compass or other suitable device. The performance of a system reduces as the orientation of the collectors moves away from true north, resulting in the need for increased boosting to supply the same hot water load. Where it is not possible or practical to install collectors facing north, they may be oriented up to 90 from north (subject to installation code requirements). It may be desirable to install an additional collector or higher performance collectors to help make up for the reduction in solar performance. Each option should be discussed with the system owner. If neither of these options is possible or acceptable to the system owner, then the system owner needs to be made aware of, understand and accept that increased boosting may be required to meet their hot water requirements. Frames are available from Rheem to raise the inclination of the collectors, and for high wind (cyclone) areas. 7

Installation Checklist Hot Water Recirculation Systems When water heaters are installed on a hot water flow and return recirculation system, the following should be included: A suitable pump correctly aligned, oriented and weather protected with a check valve and isolation valves. To reduce energy costs a timer to activate circulation in periods of regular demand. Suitable pipe insulation to minimise heat loss. A Temperature Limiting Device positioned on individual branch lines to ablution areas, not in the main flow line to the building. Where multiple water heater are manifolded, correct Equa-flow principles must be followed. 8

Anode Selection & Water Supplies Every Rheem water heater is manufactured to suit the water conditions of most public reticulated water supplies, but some water chemistries can have detrimental effects on the water heater s operation and life expectancy. Ask the local Water Supply Authority for information on the water chemistry, which you can check against the Rheem guidelines below. A water heater cylinder or heat exchanger can be affected by the chemistry of the water supply. The cylinder of the water heater is only covered by Rheem warranty when the total dissolved solids (TDS) in the water supply is below 2500mg/L and the correct colour anode is used. Using the wrong coloured anode may also shorten the life of the cylinder. Use the following table to select the correct colour anode to be fitted: Total Dissolved Solids Anode colour code 0-40 mg/l Green 40-150 mg/l Green or Black 150-400 mg/l Black 400-600 mg/l Black or Blue 600-2500 mg/l Blue 2500 mg/l + Blue (no cylinder warranty) The anode will slowly dissipate over time while protecting the cylinder. The life of the cylinder may be extended by replacing the anode. If the anode is not replaced at the 5 year service, the maximum time when it should be replaced is not more than 8-10 years (depending upon the model refer to the Owner s Guide & Installation Instructions). For water supplies that are softened, desalinated or where the water supply may alternate between tank water and reticulated public supply or another supply, it is recommended the anode be replaced within 5 years of installation and every 5 years thereafter. Saturation Index is a measure of the water s corrosive or scaling properties. A corrosive water supply can attack copper components. Where the saturation index is less than -1.0: Water is very corrosive A corrosion resistant element must be used for the Rheem warranty to cover the element 9

Anode Selection & Water Supplies - cont d In a scaling water supply calcium carbonate is deposited onto any hot metallic surface. Where the saturation index exceeds +0.4: Water is very scaling An expansion control valve must be fitted on the cold water line after the non-return valve for the Rheem warranty to cover the cylinder and TPR valve Where the saturation index exceeds +0.8: Rheem warranty does not cover a standard watts density element A low watts density element must be used for the Rheem warranty to cover the element SATURATION INDEX (SI) HEATERS no warranty applies to a: - standard watts density element - direct (open circuit) solar collector - heat pump heat exchanger - stainless steel cylinder - continuous flow copper heat exchanger WITHIN WARRANTY SPECIFICATION no warranty applies to a: temperature pressure relief valve or a water heater cylinder unless an expansion control valve is fitted. no warranty applies to a: - standard watts density element - direct (open circuit) solar collector - heat pump heat exchanger - stainless steel cylinder - continuous flow copper heat exchanger very corrosive -1.0 0 +0.4 +0.8 SATURATION INDEX (calculated @ 80 C water temperature) corrosive scaling very scaling Stainless Steel cylinders are not suitable for installation in some areas, where water chemistry is such that the cylinder can be affected. Installation in these areas may void the cylinder warranty. Before installing, check the Rheem website for suitable installation areas: www.rheem.com.au/stellar 10

Water Connections Cold Water Connection191025 The following may be required on the cold water inlet pipework (see figure below for order of installation) Isolating Valve Non-Return Valve Duo Valve Pressure Limiting or Pressure Reducing Valve Expansion Control Valve Disconnecting Union Also known as a stop cock Required for service and maintenance Also known as a check valve Soft seat type preferred Located between stop cock and water heater Do not fit to inlet of continuous flow water heater Combination isolating and non return valve Can be used instead of two separate valves Required if supply pressure is likely to exceed 80% of relief valve setting. Recommended use on supply to the entire building to ensure same pressure of cold and hot water Required for all storage water heaters in QLD, WA, SA and any other area where the water supply has a saturation index exceeding +0.4 Last valve before water heater Final fitting on the cold water plumbing. Pressure Limiting Valve Expansion Control Valve To Union Connector Stopcock Non-Return Valve 11

Water connections - cont d Hot Water Connection191025 The following are required for the hot water outlet Temperature Limiting Device/Tempering Valve/ Thermostatic mixing valve Required for bathrooms, basins, not required for kitchen, laundry Pipe Insulation The pipe work must be insulated in accordance with AS/NZS 3500.4 All piping with circulating water is to be insulated Disconnecting union First fitting after the water heater. Note: Vacuum break valves are not normally necessary. Note: Heat traps are only required on Rheem Stainless Steel top outlet water heaters. (Dip tube on other Rheem models acts as an integral heat trap). In Western Australia heat traps are required on all electric storage water heaters. Control of Delivery Temperature AS/NZS 3500.4 stipulates a maximum of up to 50 o C hot water temperature to ablution areas (bathrooms). This may be reduced to 45 o C depending on the building s use. This is mandatory for all new installations. The above requirement is mandatory in some states for replacement installation also. Check local regulatory requirements in your area for new and replacement installations. This is achievable via: For 50 C applications tempering valve, thermostatic mixing valve or an AS 3498 compliant 50 O C limited water heater model eg: Rheem Gas Continuous Flow model, RheemPlus Heat Pump, RheemPlus Gas or Electric storage For 45 C applications thermostatic mixing valve 12

Water Connections TPR and ECV Drain Line191025 The relief valve must be fitted with a drain pipe, with the following requirements: The minimum diameter of the pipe is DN15 on 15 mm valves, and DN20 on 20 mm valves. The drain pipe must be of copper. The drain pipe must be of minimum possible length and have a continuous fall to its outlet. Where the distance from the valve to the final point of discharge is greater than 9 m, the valve drain line must discharge into a tundish that is drained in accordance with AS/NZS 3500.4 Relief Valve drains must terminate in a position that is visible, will not cause nuisance or damage and will not cause injury. Local regulations may require that the discharge from relief valves terminate to a drain. In frost prone areas additional requirements apply, refer to AS/NZS 3500.4 13

Pipework and Pipe Sizing Pipe material All pipe material used must comply with the requirements of AS/NZS 3500.4. Plastic/synthetic pipe: Cannot be used for the last metre into and first metre out of the water heater these sections must be copper. Must be rated to the same maximum working pressure and temperature the water heater is capable of supplying. MUST NOT be used for solar flow and return installations. Pipe Sizing Calculating the correct pipe diameter for the installation involves 3 steps: 1. Estimate the peak required flow rate along the length of the pipe. Application Flow Rate (Hot Water) Litres/min Litres/sec Domestic Bath 18 0.3 Domestic Shower 6 0.1 Hand Basin 6 0.1 Kitchen Sink and Laundry Tub 7 0.12 Washing Machines and Dishwashers 12 0.2 Note: if the home is fitted with water saving fixtures the required flow rate will be reduced. 2. Calculate the pressure gradient along the pipe. 3. Refer to the pipe supplier s product handbook to determine the recommended pipe diameter For most domestic installations, it is acceptable to base pipe sizing for hot water reticulation on known average requirements. 14

Specific Applications Rheem water heaters (other than Commercial specific models such as Commpak or Heavy Duty models) are designed for use in a single family domestic dwelling for the purpose of heating potable water. Use in any other application may shorten the life of the water heater. If an uninterrupted hot water supply is necessary for the application or business, there should be back-up redundancy built into the system design, to ensure supply continuity in the event of the water heater becoming inoperable. We recommend you provide advice to the system owner regarding their needs and building back-up redundancy into the hot water supply system. 15

Water connections Electric Storage 17

18

Rheem Electric 25L 191025,191025/P 1 Indoor/ Outdoor Small diameter - 400mm Fast, easy like-for-like replacement Dual handed connections Plug & lead indoor models 2.4kW only 7 year cylinder warranty 1 7 WYEAR CYLINDER A R R A N T Y 400 430 106 142 60 26 O 26 O 64 O 64 O 436 MODEL 191025 191025/P Hot Water Delivery (L) 25 kw Rating 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 19 19

Rheem Electric Compact 25 111025,111025/P 1 Indoor/ Outdoor The smallest Rheem electric water heater Small diameter - 385mm Fast, easy like-for-like replacement Plug & lead indoor models 2.4kW only 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 385 390 130 420 116 60 26 O 65 O MODEL 111025 111025/P Hot Water Delivery (L) 18 kw Rating 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 20 Water Connections RP 3 /4 Approx. Weight (Empty) kg 18

Rheem Electric Compact 47 191045 1 Indoor/ Outdoor 7 WYEAR CYLINDER A R R A N T Y The most compact available in the over-40l capacity range Smallest Diameter 400mm Just 670mm HIGH (including anode cap) 47L delivery* Available in 3.6kW rating only Recessed plug fittings Dual handed easier to install 7 year cylinder warranty 1 HOT 400 670 347 T&PR VALVE 436 142 60 26 O 26 O 59 O 59 O *Rated Hot Water Delivery (L) is 40L in accordance with AS/NZS4692.1. Actual delivery is 47L when tested to AS/NZS4692.1. MODEL 191045 Hot Water Delivery (L) 47 kw Rating 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 25 21

Rheem Electric 50L 191050,191050/P 1 Indoor/ Outdoor 7 WYEAR CYLINDER A R R A N T Y Small diameter - 400mm Designed for restricted space installations Dual handed connections Plug & lead models 2.4kW only Recessed plug fittings Safe for wall mounting - Wall mounting bracket 299120 7 year cylinder warranty 1 400 695 397 436 26 o 26 o 142 60 59 o 59 o MODEL 191050 191050/P Hot Water Delivery (L) 50 kw Rating 1.8, 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 22 Water Connections RP 3 /4 Approx. Weight (Empty) kg 26

Rheem Electric 80L 191080 1-2 Indoor/ Outdoor Small diameter - 480mm Fast, easy like-for-like replacement Designed for restricted space installations Dual handed connections Recessed plug fittings Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 RELIEF VALVE 480 702 945 515 64 CABLE ENTRY 66 24 o 24 o 60 o 60 o MODEL 191080 Hot Water Delivery (L) 80 kw Rating 1.8, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 36 23

Rheem Electric 125L 191125 2-3 Indoor/ Outdoor Small diameter - 480mm Fast, easy like-for-like replacement Designed for restricted space installations Dual handed connections Recessed plug fittings Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 RELIEF VALVE 480 1340 1102 515 24 o 24 o 64 CABLE ENTRY 66 60 o 60 o MODEL 191125 Hot Water Delivery (L) 125 kw Rating 1.8, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 24 Water Connections RP 3 /4 Approx. Weight (Empty) kg 49

Rheem Electric 160L 191160, 192160 2-4 Indoor/ Outdoor Fast, easy like-for-like replacement Dual handed inlet and outlet fittings Twin element model - 192160 All models suit connection to concessional (off-peak) tariffs Mains pressure water delivery Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 HOT T&PR VALVE 480 1610 1332 1081 515 23 o 58 o 58 o 104 66 MODEL 191160 192160 Hot Water Delivery (L) 160 kw Rating 1.8, 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 55 25

Rheem Electric 250L 491250,492250 3-5 Indoor/ Outdoor Easy retrofit Dual handed inlet and outlet fittings Commercial grade enamel Thicker sacrificial anode Twin element model - 492250 Australian made 10 year cylinder warranty 1 RELIEF VALVE 640 1395 680 1117 988 32 O 88 O 92 O CABLE ENTRY 73 103 MODEL 491250 492250 Hot Water Delivery (L) 250 kw Rating 1.8, 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 26 Water Connections RP 3 /4 Approx. Weight (Empty) kg 76

Rheem Electric 315L 491315,492315 4-6 Indoor/ Outdoor Easy retrofit Dual handed inlet and outlet fittings Commercial grade enamel Thicker sacrificial anode Twin element model - 492315 Australian made 10 year cylinder warranty 1 RELIEF VALVE 640 1640 1317 680 1228 32 O 88 O 92 O CABLE ENTRY 113 103 MODEL 491315 492315 Hot Water Delivery (L) 315 kw Rating available 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP 3 /4 Approx. Weight (Empty) kg 97 27

Rheem Electric 400L 491400,492400 5-9 Indoor/ Outdoor Easy retrofit Dual handed inlet and outlet fittings Commercial grade enamel Thicker sacrificial anode Twin element model - 492400 Australian made 10 year cylinder warranty 1 RELIEF VALVE 690 1840 1479 730 121 CABLE ENTRY 105 1323 30 83 97 MODEL 491400 492400 Hot Water Delivery (L) 400 kw Rating 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 28 Water Connections RP 3 /4 Approx. Weight (Empty) kg 118

RheemPlus Electric 125L 121125 2-3 Indoor/ Outdoor Fast, easy like-for-like replacement 50 C temperature limited model supplies hot water at a maximum 50 C in accordance with AS/NZS 3500.4 Left hand connection Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 HOT T&PR VALVE 545 480 1340 1102 183 515 64 84 23 o 58 o MODEL 121125 Hot Water Delivery (L) 125 kw Rating 1.8, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections G 3 /4B Approx. Weight (Empty) kg 49 29

RheemPlus Electric 160L 121160 2-4 Indoor/ Outdoor Fast, easy like-for-like replacement 50 C temperature limited model supplies hot water at a maximum 50 C in accordance with AS/NZS 3500.4 Left hand connection Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 HOT T&PR VALVE 1610 1332 183 545 480 104 84 515 23 o 58 o MODEL 121160 Hot Water Delivery (L) 160 kw Rating 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections G 3 /4B Approx. Weight (Empty) kg 57 30

RheemPlus Electric 250L 121250 3-5 Indoor/ Outdoor Fast, easy like-for-like replacement 50 C temperature limited model supplies hot water at a maximum 50 C in accordance with AS/NZS 3500.4 Left hand connection Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 1395 HOT T&PR VALVE 705 640 1117 262 680 73 128 32 o 88 o MODEL 121250 Hot Water Delivery (L) 250 kw Rating 3.6 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections G 3 /4B Approx. Weight (Empty) kg 74 31

RheemPlus Electric 315L 121315 4-6 Indoor/ Outdoor Fast, easy like-for-like replacement 50 C temperature limited model supplies hot water at a maximum 50 C in accordance with AS/NZS 3500.4 Left hand connection Australian made 7 WYEAR CYLINDER A R R A N T Y 7 year cylinder warranty 1 HOT T&PR VALVE 1640 1317 705 640 262 113 128 680 32 o 88 o MODEL 121315 Hot Water Delivery (L) 315 kw Rating 3.6 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections G 3 /4B Approx. Weight (Empty) kg 99 32

Rheem Electric Stellar SS 50L 4A1050 1 Indoor/ Outdoor Compact design to fit into cupboards and under bench Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater 4.8% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 TPR VALVE HOT (LH) 400 695 385 432 (LH) 145 27.5 o 27.5 o 60 o 60 o POWER LEAD & PLUG (APPLICABLE MODELS ONLY) MODEL 4A1050 Hot Water Delivery (L) 50 kw Rating 1.8, 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 17 33

Rheem Electric Stellar SS 80L 4A1080 1-2 Indoor/ Outdoor Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater 24% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 TPR VALVE HOT 495 885 510 CABLE ENTRY 185 110 55 o 25 o 500 125 o MODEL 4A1080 Hot Water Delivery (L) 80 kw Rating 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 34 Water Connections RP 3 /4 Approx. Weight (Empty) kg 25

Rheem Electric Stellar SS 125L 4A1125 2-3 Indoor/ Outdoor Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater 17% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 HOT TPR VALVE 920 1295 495 185 CABLE ENTRY 110 o 25 55 o 500 125 o MODEL 4A1125 Hot Water Delivery (L) 125 kw Rating 1.8, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Approx. Weight (Empty) kg 30 35

Rheem Electric Stellar SS 160L 4A1160 2-4 Indoor/ Outdoor Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater 12% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 HOT TPR VALVE 1240 1615 495 185 CABLE ENTRY 110 o 25 55 o 500 125 o MODEL 4A1160 Hot Water Delivery (L) 160 kw Rating 2.4, 3.6 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 36 Water Connections RP 3 /4 Approx. Weight (Empty) kg 40

Rheem Electric Stellar SS 250L 4A1250, 4A2250 3-5 Indoor/ Outdoor Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater Twin element model- 4A2250 19% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 HOT 1440 TPR VALVE 990 625 230 CABLE ENTRY 145 60 o 30 o 630 120 o MODEL 4A1250 4A2250 Hot Water Delivery (L) 250 kw Rating 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP 3 /4 Approx. Weight (Empty) kg 45 37

Rheem Electric Stellar SS 315L 4A1315, 4A2315 4-6 Indoor/ Outdoor Stainless steel cylinder and water fittings resist corrosion for longer, extending product life Dual handed fittings located on the front of the water heater Twin element model- 4A2315 17% better performance than MEPS reduces energy use, saving money Up to 42% lighter 2 - for easier handling and installation Australian made 10 year cylinder warranty 1 HOT TPR VALVE 1310 625 1760 230 CABLE ENTRY 145 60 o 30 o 630 120 o MODEL 4A1315 4A2315 Hot Water Delivery (L) 315 kw Rating 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 38 Water Connections RP 3 /4 Approx. Weight (Empty) kg 55

Rheem Electric Heavy Duty 50L 613050 235-295* FIRST HR DEL Indoor/ Outdoor Ideal for cafés, hair salons and small business applications Larger mass anode Quick recovery 5 year commercial warranty on cylinder 1 HOT 440 675 405 TPR VALVE 90 80 30 O 90 O 480 *First hour delivery calculated @ 50 o C rise MODEL 613050 Hot Water Delivery (L) 50 kw Rating (3 elements) 3.6, 4.8 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP1 1 /4 Approx. Weight (Empty) kg 34 39

Rheem Electric Heavy Duty 315L 613315 500-625* FIRST HR DEL Indoor/ Outdoor Ideal for cafés, hair salons and small business applications 3 element model Larger mass anode Quick recovery 5 year commercial warranty on cylinder 1 HOT Ø640 TPR VALVE 1640 1294 32 O 680 128 130 90 O *First hour delivery calculated @ 50 o C rise MODEL 613315 Hot Water Delivery (L) 315 kw Rating (3 elements) 3.6, 4.8, 6.0 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 40 Water Connections RP1 1 /4 Approx. Weight (Empty) kg 100

Rheem Electric Heavy Duty 315L 616315 685-935* FIRST HR DEL Indoor/ Outdoor Ideal for cafés, hair salons and industrial applications 6 element model Larger mass anode Quick recovery 5 year commercial warranty on cylinder 1 HOT Ø640 TPR VALVE 1640 1294 32 O 680 128 130 90 O *First hour delivery calculated @ 50 o C rise MODEL 616315 Hot Water Delivery (L) 315 kw Rating (6 elements) 3.6, 4.8, 6.0 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP1 1 /4 Approx. Weight (Empty) kg 104 41

Rheem Wall Mounting Bracket 299120 Indoor/ Outdoor Suitable for 25L, 50L & 80L To be only used on walls that can support the load of a filled water heater For fixing to wood use Tek screws for fixing to concrete, brick masonry and natural stone use Dynabolts TM with 8mm masonry drill (nominal embedment 32mm). Dynabolts TM are not suitable for fixing to mortar or soft masonry (not included) Slotted Top Plate 152 18 117 6 Bottom Angle Support 29 95 17 17 8 5 152 89 152 140 89 13 127 13 127 152 57 8 Offset Plate 110 17 17 95 13 10 o 8 10 25 130 MODEL 299120 42 For suitable for Rheem models 191025, 111025, 191045, 4A1050, 191050, 4A1080, 191080

Conditions apply: 1 See the Rheem warranty in the product s Owner s Guide or view product warranties at www.rheem.com.au/warranty 2 Up to 42% lighter than comparable Rheem vitreous enamel water heater models of the same capacity. 43

44

Gas Storage 45

Rheem Gas Internal 135L 300135 2-4 Indoor Suitable for indoor installations Mains pressure to service multiple hot water demand at once An easy replacement for most existing 3 Star models Natural and propane gas model Australian made 5 year cylinder warranty 1 Ø75 NOM. HOT Rheem 425 1615 988 TPR VALVE 1490 500 GAS 58 328 297 MODEL 300135 Storage Capacity (L) 135 Hourly Recovery (L) 120 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 54 47

Rheem Gas Internal 170L 300170 3-5 Indoor Suitable for indoor installations Mains pressure to service multiple hot water demand at once An easy replacement for most existing 3 Star internal models Natural gas model 5 year cylinder warranty 1 Australian made Ø75 NOM. 1915 1213 HOT TPR VALVE 425 1790 500 403 GAS 297 58 MODEL 300170 Storage Capacity (L) 170 Hourly Recovery (L) 126 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 63 48

Rheem 4 Star Gas 90L 347090 1-2 Outdoor 4 Star energy efficiency Mains pressure at multiple taps Easy replacement common fittings with standard 3 Star models Natural gas model 7 year cylinder warrany 1 7 WYEAR CYLINDER A R R A N T Y 1078 HOT RELIEF VALVE 1158 588 GAS 916 328 298 208 473 502 422 MODEL 347090 Storage Capacity (L) 90 Hourly Recovery (L) 100 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 48 49

Rheem 4 Star Gas 135L 347135 2-5 Outdoor 4 Star energy efficiency Mains pressure at multiple taps Easy replacement common fittings with standard 3 Star models Natural and propane gas model 7 year cylinder warrany 1 7 WYEAR CYLINDER A R R A N T Y HOT RELIEF VALVE 1558 988 1478 GAS 1316 328 298 208 473 502 422 MODEL 347135 Storage Capacity (L) 135 Hourly Recovery (L) 113 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 59 50

Rheem 4 Star Gas 170L 347170 2-5 Outdoor 4 Star energy efficiency Mains pressure at multiple taps Easy replacement common fittings with standard 3 Star models Natural and propane gas model 7 year cylinder warrany 1 7 WYEAR CYLINDER A R R A N T Y 1858 1213 HOT RELIEF VALVE 1778 403 GAS 298 1616 208 473 502 422 MODEL 347170 Storage Capacity (L) 170 Hourly Recovery (L) 113 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 69 51

Rheem 5 Star Gas - 265 350265 2-5 Outdoor 7 WYEAR CYLINDER A R R A N T Y 5 Star energy efficiency Mains pressure at multiple taps Strong recovery to have you back in hot water fast 275L first hour capacity of hot water Compact size 490mm diameter Natural gas model 7 year cylinder warranty¹ 1600 988 HOT RELIEF VALVE 556 528 240 490 RELIEF VALVE GAS 332 302 605 300 95 MODEL 350265 Storage Capacity (L) 130 Hourly Recovery (L) 145 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 75 52

Rheem 5 Star Gas - 295 350295 3-5 Outdoor 7 WYEAR CYLINDER A R R A N T Y 5 Star energy efficiency Mains pressure at multiple taps Strong recovery to have you back in hot water fast 305L first hour capacity of hot water Compact size 490mm diameter Natural gas model 7 year cylinder warranty¹ HOT RELIEF VALVE 490 1900 1213 556 528 240 RELIEF VALVE GAS 407 302 605 300 95 MODEL 350295 Storage Capacity (L) 160 Hourly Recovery (L) 145 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 85 53

RheemPlus 5 Star Gas - 265 354265 2-4 Outdoor 5 Star energy efficiency Mains pressure at multiple taps 50 C temperature limited models supply hot water at a maximum 50 C in accordance with AS 3498 Natural gas model 7 year cylinder warranty¹ 7 WYEAR CYLINDER A R R A N T Y HOT RELIEF VALVE 545 490 1600 988 556 528 240182 RELIEF VALVE GAS 332 302 605 300 95 MODEL 354265 Storage Capacity (L) 130 Hourly Recovery (L) 145 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections G 3 /4B 54 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 76

RheemPlus 5 Star Gas - 295 354295 3-5 Outdoor 5 Star energy efficiency Mains pressure at multiple taps 50 C temperature limited models supply hot water at a maximum 50 C in accordance with AS 3498 Natural gas model 7 year cylinder warranty¹ 7 WYEAR CYLINDER A R R A N T Y HOT RELIEF VALVE 545 490 1900 1213 556 528 240182 RELIEF VALVE GAS 407 302 605 300 95 MODEL 354295 Storage Capacity (L) 160 Hourly Recovery (L) 145 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections G 3 /4B Gas Connections RP 1 /2 Approx. Weight (Empty) kg 86 55

Rheem Stellar Gas - 330 850330 2-5 Outdoor 5 Star energy efficiency uses less gas than 3 or 4 Star water heaters 200L/hour hot water recovery Advanced technology the Stellar Superflue Mains pressure to service multiple hot water demands at once Natural gas model 10 year cylinder warranty 1 Australian made 252 HOT 485 1600 252 252 988 558 TPR VALVE GAS 299 93 328 210 298 520 MODEL 850330 Storage Capacity (L) 130 Hourly Recovery (L) 200 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 70 56

Rheem Stellar Gas - 360 850360 3-6 Outdoor 5 Star energy efficiency uses less gas than 3 or 4 Star water heaters 200L/hour hot water recovery Advanced technology the Stellar Superflue Mains pressure to service multiple hot water demands at once Natural gas model 10 year cylinder warranty 1 Australian made 252 HOT 485 1900 252 252 1213 558 TPR VALVE GAS 299 93 409 210 298 520 MODEL 850360 Storage Capacity (L) 160 Hourly Recovery (L) 200 Relief Valve Setting (kpa) 1400 Expansion Control Valve (kpa) 1200 Max Water Supply Pressure: with ECV (kpa) 960 without ECV (kpa) 1120 Water Connections RP 3 /4 Gas Connections RP 1 /2 Approx. Weight (Empty) kg 80 57

Rheem Heavy Duty Gas 260L 630260 385L* FIRST HR DEL Outdoor Supply large quantities of hot water Double layer of vitreous enamel Adjustable thermostat Equa-Flow system allows for flexibility in installation Natural gas & Propane model 5 year commercial warranty on cylinder 1 HOT TPR VALVE 990 1640 1520 680 655 295 27 O GAS 330 300 420 590 *First hour delivery calculated @ 50 o C rise MODEL 630260 Storage Capacity (L) 260 Thermal Input (MJ/hr) 51 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 /4 Gas Connections (BSPF) RP 1 /2 Approx. Weight (Empty) kg 106 58

Rheem Heavy Duty Gas 260L 620260 385L* FIRST HR DEL Indoor Supply large quantities of hot water Double layer of vitreous enamel Adjustable thermostat Equa-Flow system allows for flexibility in installation Natural gas & Propane model 5 year commercial warranty on cylinder 1 100 HOT 1660 TPR VALVE 590 1520 1320 GAS 670 27 O 330 300 *First hour delivery calculated @ 50 o C rise MODEL 620260 Storage Capacity (L) 260 Thermal Input (MJ/hr) 51 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 1 /4 Gas Connections (BSPF) RP 1 /2 Approx. Weight (Empty) kg 98 59

Rheem Heavy Duty Gas 265L 631265 620L* FIRST HR DEL Outdoor Multi-Fin technology means faster, more efficient heating Electronic ignition for economy Equa-Flow system allows for flexibility in installation Digital adjustable thermostat to 82 C for sanitisation applications BMS option available Natural gas, Propane & Butane model 5 year commercial warranty on cylinder 1 750 HOT TPR VALVE 1835 1655 710 660 302 36 O GAS 700 380 420 610 *First hour delivery calculated @ 50 o C rise MODEL 631265 Storage Capacity (L) 265 Thermal Input (MJ/hr) 110 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 /4 Gas Connections (BSPF) RP 3 /4 Approx. Weight (Empty) kg 146 60

Rheem Heavy Duty Gas 265L 621265 620L* FIRST HR DEL Indoor Multi-Fin technology means faster, more efficient heating Electronic ignition for economy Equa-Flow system allows for flexibility in installation Digital adjustable thermostat to 82 C for sanitisation applications BMS option available Natural gas, Propane & Butane model 5 year commercial warranty on cylinder 1 125 HOT TPR VALVE 750 1655 1795 610 302 700 GAS 750 660 36 O 380 *First hour delivery calculated @ 50 o C rise MODEL 621265 Storage Capacity (L) 265 Thermal Input (MJ/hr) 110 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 1 /4 Gas Connections (BSPF) RP 3 /4 Approx. Weight (Empty) kg 137 61

Rheem Heavy Duty Gas 275L 970L* 631275 FIRST HR DEL Multi-Fin technology means faster, more efficient heating Electronic ignition for economy Digital adjustable thermostat to 82 C for sanitisation applications Outdoor installation or Indoor room sealed with kit (purchased separately) BMS option available Natural gas, Propane & Butane model 5 year commercial warranty on cylinder 1 Indoor/ Outdoor 760 HOT TRP VALVE 1865 1695 780 722 320 36 O GAS 700 340 320 640 *First hour delivery calculated @ 50 o C rise MODEL 631275 Storage Capacity (L) 265 275 Thermal Input (MJ/hr) (MJ) 200 110 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 1 /4 Gas Connections (BSPF) RP 3 /4 Approx. Weight (Empty) kg 132 187 62

Rheem Heavy Duty Gas 275L 621275 970L* FIRST HR DEL Indoor Multi-Fin technology means faster, more efficient heating Electronic ignition for economy Equa-Flow system allows for flexibility in installation Digital adjustable thermostat to 82 C for sanitisation applications BMS option available Natural gas, Propane & Butane model 5 year commercial warranty on cylinder 1 200 HOT TPR VALVE 760 1695 1895 640 320 700 GAS 780 722 36 O 340 *First hour delivery calculated @ 50 o C rise MODEL 621275 Storage Capacity (L) 275 Thermal Input (MJ/hr) 200 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections (BSPF) RP 1 1 /4 Gas Connections (BSPF) RP 3 /4 Approx. Weight (Empty) kg 172 63

Conditions apply: 1 See the Rheem warranty in the product s Owner s Guide or view product warranties at www.rheem.com.au/warranty 2 Up to 42% lighter than comparable Rheem vitreous enamel water heater models of the same capacity. 64

Gas Continuous Flow 65

66

Rheem 12L 876612, 874612 1-2 Outdoor ENERGY EFFICIENT STAR 12 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options Accessories: Pipe cover 299841, Recess Box 299842, 299842/WA Security Cage 299867 50 C models available, requiring no tempering valve 3 LED display for easy fault diagnosis Natural gas & Propane models 10 year heat exchanger warranty 1 350 90 MOUNTING HOLES 592 560 520 490 592 54 HOT GAS CONNECTION 10 16 163 5357 126 125 43 POWER LEAD CONNECTION GAS CONNECTION HOT 51 43 45 164 C L MODEL 876612 874612 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 94 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 16 67

Rheem Standard Flue Diverter 299881 - suitable for 12L/16L Outdoor Enables compliance with relevant national and local regulations for installation in covered open areas.* Suitable for Rheem 12L or Rheem Metro 16L Offers added flexibility in installation Fits simply to the water heater Natural gas model Suitable for installation with Recess Box 299842, 299842/WA Pipe Cover 299841 5 24 379 262 160 520 350 *Confirm with your local authorities that the installation complies with all regulations applicable in your area. 68 PART 299881 To suit models: 876612NF, 874612NF 876E16NF, 874E16NF

Rheem Metro 16L 876E16, 874E16 1-3 Outdoor ENERGY EFFICIENT STAR 16 L/min continuous hot water delivery @ 25 o C rise 60ºC hot water for kitchen and laundry 50ºC models provide added safety Remote Temperature Controller options for added convenience and safety LED display for easy fault diagnosis Natural gas & Propane models 10 year heat exchanger warranty¹ 350 90 MOUNTING HOLES 592 560 520 490 592 54 HOT GAS CONNECTION 10 16 163 5357 126 125 43 POWER LEAD CONNECTION GAS CONNECTION HOT 51 43 45 164 C L MODEL 876E16 874E16 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 126 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 16 69

Rheem 20L 876620, 874620 ENERGY EFFICIENT STAR 2-4 Outdoor 20 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options 50 C models available, requiring no tempering valve 3 LED display for easy fault diagnosis Natural gas & Propane models Accessories: Pipe Cover 299841, Recess Box 299842, 299842/WA Security Cage 299867 10 year heat exchanger warranty 1 350 90 MOUNTING HOLES 592 560 520 490 592 54 HOT GAS CONNECTION 10 16 163 5357 126 125 43 POWER LEAD CONNECTION GAS CONNECTION HOT 51 43 45 164 C L MODEL 876620 874620 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 153 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 16 70

Rheem Metro Plus 24L 875E24, 871E24 4-5 Outdoor ENERGY EFFICIENT STAR 24 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options 50 C models available, requiring no tempering valve 3 Digital display for easy fault diagnosis Natural gas & Propane models Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867 MOUNTING HOLES 350 90 10 year heat exchanger warranty 1 19 44 605 565 562 647 HOT POWER CONNECTION HOT 132 17 92 GAS CONNECTION 21 GAS 10 16 205 50 65 127 112 C L 53 103 MODEL 875E24 871E24 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 19 71

Rheem 24L 875624, 871624 ENERGY EFFICIENT STAR 4-5 Outdoor 24 L/min continuous hot water delivery @ 25 o C rise Flamesafe overheat protection Remote temperature controller options 50 C models available, requiring no tempering valve 3 Digital display for easy fault diagnosis Natural gas & Propane models 10 year heat exchanger warranty 1 MOUNTING HOLES 350 90 19 44 605 565 562 647 HOT POWER CONNECTION HOT 132 17 92 GAS CONNECTION 21 GAS 10 16 205 50 65 127 112 C L 53 103 MODEL 875624 871624 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 21 72

Rheem Metro Plus 24L Standard Flue Diverter 875E24NF-FD 4-5 Outdoor Enables compliance with relevant national and local regulations for installation in covered open areas.* Adjustable to deliver 50 O C at the nearest tap Recess Box available -299842 to set water heater into the wall. Compatible with flue diverter. Digital display for easy fault diagnosis and service Natural gas model 10 year heat exchanger warranty¹ 33 379 350 305 205 119 137 *Confirm with your local authorities that the installation complies with all regulations applicable in your area. MODEL 875E24NF-FD Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 19 73

Rheem Metro Plus 24L Extended Flue Diverter 875E24NF-FE 4-5 Outdoor Enables compliance with relevant national and local regulations for installation in covered open areas.* Digital display for easy fault diagnosis Natural gas model 10 year heat exchanger warranty¹ 350 no greater than 695 Edge of balcony 591 938 66 350 Edge of balcony 305 205 119 137 565 *Confirm with your local authorities that the installation complies with all regulations applicable in your area. MODEL 875E24NF-FE Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connections R 3 /4 Approx. Weight (Empty) kg 19 74

Rheem Metro Max 26L 875E26, 871E26 4-5 Outdoor ENERGY EFFICIENT STAR 26 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options 50 C models available, requiring no tempering valve 3 Digital display for easy fault diagnosis Natural gas & Propane models Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867 MOUNTING HOLES 350 90 10 year heat exchanger warranty 1 19 44 605 565 562 647 HOT POWER CONNECTION HOT 132 17 92 GAS CONNECTION 21 GAS 10 16 205 50 65 127 112 C L 53 103 MODEL 875E26 871E26 Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 199 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 21 75

Rheem 27L 876627, 874627 4-6 Outdoor ENERGY EFFICIENT STAR 27 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options for added convenience and safety 50 C models available, requiring no tempering valve 3 Digital display for easy fault diagnosis Natural gas & Propane models 10 year heat exchanger warranty 1 351 269 90 17 42 669 601 669 54 POWER LEAD CONNECTION HOT 84 132 127 226 GAS CONNECTION 28 C L 64 97 227 MODEL 876627 874627 Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connection R 3 /4 Approx. Weight (Empty) kg 24 76

Rheem 27L Internal 866627, 864627 4-6 Indoor ENERGY EFFICIENT STAR 27 L/min continuous hot water delivery @ 25 o C rise Remote Temperature Controller options for added convenience and safety Rheem co-axial flue system 50 C models available, requiring no tempering valve 3 Digital display for easy fault diagnosis Natural gas model 10 year heat exchanger warranty 1 351 240 331 131 Ø127 17 763 707 650 49 38 53 HOT POWER LEAD CONNECTION GAS CONNECTION 21 10 to 40 POWER LEAD CONNECTION 132 127 5 GAS CONNECTION HOT 107 C L 28 240 119 86 MODEL 866627 864627 Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205 Max Water Supply Pressure (kpa) 1000 Min Water Supply Pressure (kpa) 140 Water Connections R 3 /4 Gas Connections R 3 /4 Approx. Weight (Empty) kg 24 77

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627 295116 Horizontal Terminal 295117 Vertical Terminal 97 227 Ø233 Ø208 Ø127 Ø76 300 260 140 295118 90 Bend Approx 207 Approx 255 Approx 192 Approx 400 Approx 270 Approx 500 Approx 380 295119 45 Bend 260 400 210 280 Approx 153 78 PART DESCRIPTION WHERE USED 295116 Horizontal Terminal Required where flue terminates horizontally 295117 Vertical Terminal Required where flue terminates vertically 295118 90º Bend Maximum of 3 per installation Maximum of 6 per installation (with no 90º 295119 45º Bend bends) Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation.

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627 295122 Straight Length 900mm 295123 FF Adapter 213 887 295124 MM Adapter 187 295125 Trim Ring Ø230 Ø133 295126 Straight Length 300mm 277 PART DESCRIPTION WHERE USED 295122 Straight Length 900mm Long straight sections 295123 Female Female Adapter Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues 295124 Male Male Adapter 295125 Trim Ring (optional) Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues Conceal internal and/or external hole in wall or ceiling terminating flues 295126 Straight Length 300mm Short straight sections Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation. 79

Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627 295127 Adjustable Straight 560 890mm 890 MAX 560 MIN 295129 Bracket 145 180 Ø127 25 295139 Condensate Trap PART DESCRIPTION WHERE USED 295127 295129 Bracket Adjustable Length 560 890mm 295139 Condensate Trap Allows to trim flue to exact length required Support flue at intervals not exceeding 2m and after any bend Required with every condensate drain. Can be connected to a common waste 80 Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation.

Rheem Continuous Flow Flue System Typical Internal Flue Installation Refer to Rheem Owner s Guide and Installation Instruction for details. Horizontal termination to adjacent wall 13.5m MAXIMUM LINEAL LENGTH* SUBTRACT 1.5M PER 90 BEND OR 0.75m PER 45 BEND 295124 295127 295122 295123 295116 295118 295126/ 295122/ 295127 20mm SLOPE 1000mm 295125 Direct Vent Horizontal Wall Direct Vent Vertical Termination 295118 295126 295116 295117 VERTICAL TERMINAL 295125 (optional) FLASHING (not supplied) 13.5m MAXIMUM* 295122 295126 295139 * Note: Maximum flue length with no bends is 13.5m. Reduce the maximum length by 1.5m for every 90 bend and reduce the maximum length by 0.75m for every 45 bend. Flue termination must comply with the requirements of AS/NZS 5601.1 81

Controllers Rheem Standard and Deluxe Electronic Temperature Controllers Suitable for all Rheem Continuous Flow models Allows you to choose the desirable hot water temperature Standard or Deluxe models Deluxe controllers offer a bath fill mode to turn off the water flow once the bath is filled Temperature Controller with cable 299850 - Kitchen 299851 - Bathroom 1 299852 - Bathroom 2 Deluxe Temperature Controller with cable 299858 - Kitchen 299859 - Bathroom 1 299860 - Bathroom 2 Controllers and cable also available separately 82

Rheem EZ Link 290141 Suitable for use with all Rheem 12,16, 20 and 27 L/min Continuous Flow gas water heater models Flexible delivery of up to 54 L/min Staged heating, so energy usage corresponds only to the hot water demand 2 units means no loss of hot water supply in the event of a unit breakdown Optional remote controller for temperature control, easy fault diagnosis and service MODEL 290141 Suitable for Rheem 12,16, 20 and 27 L/min models Refer to EZ Link Owner s Guide and Installation Instructions for the set up procedure. 83

1030 Rheem Security Cage 299867 Rheem Security Cage for use with all Rheem continuous flow gas water heater models. The kit contains: 1. Security cage 2. Top mounting bracket 3. Bottom mounting bracket 4. Securing fasteners 600 2 508 261 4 1 3 565 84

Rheem Security Wall Bracket 299868 Suitable for most Rheem Continuous Flow units A Hole size Ø7mm B Flat Security Bracket to be fixed to the masonry wall with supplied anchors and shear-off nuts. A 233 190 42 117 30 U Shaped Security Bracket to be fastened to flat bracket using a padlock (padlock not supplied) B 86 33 42 168 PART 299868 Suitable for models: 875E24, 871E24, 875624, 871624, 875E26, 871E26, 876627, 874627 85

Rheem Recess Box 299842 (12-26L), 299831 (27L) Galvanised Steel Especially designed for standard double brick construction, WA models suit solid brick construction In-built anti-theft bracket Easy access door Security Bracket Requires Padlock (not Supplied) TH 0 0 PART NO. FASCIA CAVITY Height Width Depth Height Width Depth A B C D E F 299842 (12-26L) 1088 425 25 1010 347 160 299831 (27L) 1081 435 50 1010 352 160 299842/WA (12-26L) 1088 425 59 1015 347 125 299831/WA (27L) 1091 435 85 1018 353 125 The installation position of the Rheem Continuous Flow unit must comply with AS 5601 or AS/NZS 5601.1. This should be considered when choosing the installation position of the Recess box. 86

Rheem Pipe Cover Kit 299841, 299848, 299830 3-5 Indoor/ Outdoor The Pipe Cover is to be installed after the Continuous Flow water heater has been installed. The pipe cover is designed to be installed underneath the water heater to cover the pipe work and valves, but cannot cover the external GPO. The kit contains: 1. Pipe cover housing 2. Pipe cover access panel 1 2 MODEL 299841 suitable for 12-20L/min 299848 suitable for 24L/min and 26L/min 299830 suitable for 27L/min 87

Rheem Pronto 834012 ENERGY EFFICIENT STAR Easy installation matching common mechanical water heater fittings 6 Star energy efficiency 12 L/min continuous hot water delivery @ 25 o C rise Electronic temperature control Overheat protection Indoor/ 13-24 Outdoor Outdoor No electrical connection required Available in natural and propane Optional heat shield available - 299880 10 year heat exchanger warranty 1 285 268 120 120 840 465 R3.5 R8 45 HOT 388 GAS (FLUSH TO BASE) 45 222 70 HOT 70 88 GAS MODEL 834012 Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 99 Natural Nom. Gas Consumption (MJ/hr) 96 Propane Max Water Supply Pressure (kpa) 800 Min Water Supply Pressure (kpa) 120 Water Connections R 1 /2 Gas Connection Rp 3 /4 Approx. Weight (Empty) kg 21 69 55 69 120 120 C L

Rheem Pronto 834016 5.9 ENERGY EFFICIENT STAR Easy installation matching common mechanical water heater fittings 5.9 Star (NG) 5.8 Star (Propane) 16 L/min continuous hot water delivery @ 25 o C rise Electronic temperature control Overheat protection 1-3 Outdoor No electrical connection required Available in natural and propane Optional heat shield available - 299880 10 year heat exchanger warranty 1 285 268 120 120 875 451 R3.5 R8 50 443 HOT GAS (FLUSH TO BASE) 50 222 84 HOT 84 GAS MODEL 834016 Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 128 Natural Nom. Gas Consumption (MJ/hr) 125 Propane Max Water Supply Pressure (kpa) 800 Min Water Supply Pressure (kpa) 140 Water Connections R 1 /2 69 48 69 120 120 C L Gas Connection Rp 3 /4 Approx. Weight (Empty) kg 25 89

Conditions apply: 1 See the Rheem warranty in the product s Owner s Guide or view product warranties at www.rheem.com.au/warranty 2 Up to 42% lighter than comparable Rheem vitreous enamel water heater models of the same capacity. 3 60ºC and higher temperature models and some applications require a tempering valve in accordance with AS 3500.4.

Solar 91

92

Rheem Loline 160L 511161 1-4 Outdoor Split system design vitreous enamel lined cylinder installed at ground level Limited frost protection 4 24 L/min in-series gas booster site integrated or Rheem 27L/min in-series gas booster installed remotely Suitable with CSA2612 collector (VIC & SA) or 2 LCS collectors (VIC only) Eligible for STCs 5 5 year cylinder warranty 1 514 480 695 23 65 47 110 395 SOLAR PREHEAT 1615 SOLAR HOT (FROM COLLECTOR) 987 937 529 61 105 SOLAR (TO COLLECTOR) MODEL 511161 Storage Capacity (L) 165 Solar Collectors (VIC or SA) 1 CSA2612 Solar Collectors (VIC only) 2 LCS Booster Type Gas Weight Empty (kg)- Tank without booster 52 Weight Empty (kg)- Tank with booster 73 Tank Water Connections RP 3 /4 Gas Booster Water Connections R 3 /4 Gas Connection R 3 /4 93

Rheem Loline 270L 511271 2-5 Indoor/ Outdoor Split system design vitreous enamel lined cylinder installed at ground level Limited frost protection 4 Booster choice of electric element or 6-Star continuous flow gas Gas booster tank mounting kit available 2 or 3 NPT200 or 2 LCS collectors Eligible for STCs 5 5 year cylinder warranty 1 640 32 o 680 88 o 32 o HOT SOLAR HOT (FROM COLLECTOR) 1395 1112 TPR VALVE ELECTRICAL CABLE ENTRY 73 412 73 588 SOLAR (FROM COLLECTOR) MODEL 511271 Storage Capacity (L) 270 Solar Collectors 2 or 3 NPT200, 2 LCS Booster Type Electric or Gas Element size (kw) 3.6 Weight Empty (kg) - Tank 71 94 Water Connections RP 3 /4

Rheem Loline 325L 511325 2-6 Indoor/ Outdoor Split system design vitreous enamel lined cylinder installed at ground level Limited frost protection 4 Booster choice of electric element or 6-Star continuous flow gas Gas booster tank mounting kit available 2 or 3 NPT200 or 2 LCS collectors Eligible for STCs 5 5 year cylinder warranty 1 640 680 32 o 88 o 32 o HOT SOLAR HOT (FROM COLLECTOR) 1640 1357 T&PR VALVE 73 481 ELECTRICAL CABLE ENTRY 73 710 SOLAR (FROM COLLECTOR) MODEL 511325 Storage Capacity (L) 325 Solar Collectors 2 or 3 NPT200, 2 LCS Booster Type Electric or Gas Element size (kw) 3.6 Weight Empty (kg) - Tank 87 Water Connections RP 3 /4 95

Rheem Loline 410L 511410 3-7 Indoor/ Outdoor Split System design vitreous enamel lined cylinder installed at ground level Limited frost protection 4 Booster choice of electric element or 6-Star continuous flow gas 2, 3 or 4 NPT200 or 2 or 3 LCS collectors Eligible for STCs 5 5 year cylinder warranty 1 690 30 o 730 82 o 30 o HOT SOLAR HOT (FROM COLLECTOR) 1840 1519 T&PR VALVE ELECTRICAL CABLE ENTRY 81 532 81 795 SOLAR (FROM COLLECTOR) MODEL 511410 Storage Capacity (L) 410 Solar Collectors 2, 3 or 4 NPT200, 2 or 3 LCS Booster Type Electric or Gas Element size (kw) 3.6 Weight Empty (kg) - Tank 111 96 Water Connections RP 3 /4

Rheem Premier Loline 160L 590160 2-5 Outdoor Complete Frost Protection Unique Drain-Back heat exchange technology Complies with regulations in all states Booster 6-star continuous flow gas Compact spilt system design 1 T200, 2 NPT200 or 2 LCS collectors Eligible for STCs 5 5 year cylinder warranty 1 51 423 212 503 211 SOLAR CONNECTIONS SOLAR PREHEAT TPR VALVE 1818 1615 1213 1613 1858 402 MODEL 590160 Storage Capacity (L) 160 Solar Collectors 1 T200, 2 LCS or 2 NPT200 Booster Type Gas Weight Empty - (kg) Tank 93 Tank Water Connections RP 3 /4 Gas Booster Water Connections R 3 /4 Gas Connections R 3 /4 97

Rheem Premier Loline 160L 596160 2-5 Outdoor Complete Frost Protection Unique Drain-Back heat exchange technology Complies with regulations in all states Booster 6-star 20 L/min continuous flow gas (factory fitted) Compact spilt system design 1 T200, 2 NPT200 or 2 LCS collectors Eligible for STCs 5 5 year cylinder warranty 1 51 423 212 1818 408 805 690 503 211 SOLAR CONNECTIONS SOLAR PREHEAT 1613 1858 1206 402 HOT TPR VALVE MODEL 596160 Storage Capacity (L) 160 Solar Collectors 1 T200, 2 LCS or 2 NPT200 Booster Type Gas Weight Empty (kg) - Tank 112 Water Connections RP 3 /4 Gas Booster Water Connections R 3 /4 Gas Connections R 3 /4 98

Rheem Premier Loline 270L 596270 2-5 Outdoor Complete Frost Protection Unique Drain-Back heat exchange technology Complies with regulations in all states Booster 27 L/min 6-star continuous flow gas (site integrated) Full mains pressure for multiple outlets Integrated tempering valve 2 or 3 SPA2000 or T200 collectors Eligible for STCs 5 5 year cylinder warranty 1 648 182 215 324 890 48 o 351 FLUE TERMINAL 1701 1787 510 772 1654 1455 265 MODEL 596270 Storage Capacity (L) 270 Solar Collectors 2 or 3 SPA2000 2 or 3 T200 Booster Type Gas Weight Empty - (kg) Tank without booster 141 Weight Empty - (kg) Tank with booster 165 Water Connections RP 3 /4 Gas Connections R 3 /4 99

Rheem Premier Loline 270L 591270 2-5 Indoor/ Outdoor Complete Frost Protection Unique Drain-Back heat exchange technology Complies with regulations in all states Booster electric element Full Mains Pressure for multiple outlets 2 or 3 SPA2000 or T200 collectors Eligible for STCs 5 5 year cylinder warranty 1 648 324 344385 47 o 73 o 682 HOT 1775 1078 TPR VALVE ELECTRICAL CABLE ENTRY 1701 980 377 MODEL 591270 Storage Capacity (L) 270 Solar Collectors 2 or 3 SPA2000 2 or 3 T200 Booster Type Electric Element size (kw) 3.6 Weight Empty (kg) - Tank 146 Weight Empty - (kg) Solar Collector (each) 48 100 Water Connections RP 3 /4

Rheem 52L Series 52L180 1-2 Outdoor 7 WYEAR CYLINDER A R R A N T Y Suitable for temperate or tropical location Stainless steel cylinder The 52L Series system directly heats the water as it passes through the collectors Booster choice of electric element or 6-Star continuous flow gas Eligible for STCs 5 7 year cylinder warranty 1 with NPT200 collector 10 year cylinder warranty 1 with L, CSA2007 collector* HOT TPR VALVE ELECTRICAL CONNECTION 79 563 2490 1495 1937 1022 1138 * Available through Rheem Solar Specialists only MODEL 52L180 Storage Capacity (L) 180 Solar Collectors 1 NPT200, L, CSA2007 Booster Type Electric or Gas Weight Empty (kg) - Tank 48 Weight Empty - (kg) Solar Collector (each) 33 Water Connections DN15 Compression Gas Connections DN15 Compression 101

Rheem 52L Series 52L300 2-5 Outdoor 7 WYEAR CYLINDER A R R A N T Y Suitable for temperate or tropical location Stainless steel cylinder The 52L Series system directly heats the water as it passes through the collectors Booster choice of electric element or 6-Star continuous flow gas Available in four COLORBOND Steel colours Eligible for STCs 5 7 year cylinder warranty 1 10 year cylinder warranty 1 with L, CSA2007 collector* 563 2180 HOT TPR VALVE ELECTRICAL CONNECTION 79 2490 1937 2094 2198 * Available through Rheem Solar Specialists only MODEL 52L300 Storage Capacity (L) 300 Solar Collectors 2 NPT200, L, CSA2007 Booster Type Electric or Gas Weight Empty (kg) - Tank 72 Water Connections DN15 Compression 102

Rheem Hiline 52S 52S160 1-2 Outdoor Energy efficient Booster choice of electric element or 6-Star continuous flow gas Vitreous enamel lined cylinder Eligible for STCs 5 5 year cylinder warranty 1 HOT TPR VALVE ELECTRICAL CONNECTION 540 1070 79 1937 2490 1022 1138 MODEL 52S160 Storage Capacity (L) 160 Solar Collectors 1 NPT200 Booster Type Electric or Gas Weight Empty (kg) - Tank 70 Hot Water Connection RP 3 /4 Cold Water Connection G 1 /2 B 103

Rheem Hiline 52S 52S300 23-5 Outdoor Energy efficient Booster choice of electric element or 6-Star continuous flow gas Vitreous enamel lined cylinder Eligible for STCs 5 5 year cylinder warranty 1 HOT 540 1865 TPR VALVE ELECTRICAL CONNECTION 79 2490 1937 1022 2094 2198 MODEL 52S300 Storage Capacity (L) 300 Solar Collectors 2 NPT200 Booster Type Electric or gas Weight Empty (kg) - Tank 100 Hot Water Connection RP 3 /4 Cold Water Connection G 1 /2 B 104

Rheem Premier Hiline 52H 52H180 1-2 Outdoor 7 WYEAR CYLINDER A R R A N T Y Complete frost protection Space saving design a complete roof mounted installation Stainless steel cylinder Booster choice of electric element or 6-Star continuous flow gas Eligible for STCs 5 7 year cylinder warranty 1 with SPA2000, NPT200 10 year cylinder warranty 1 with L, CSA2007 collector* HOT TPR VALVE ELECTRICAL CONNECTION 79 563 2490 1495 1937 1022 1138 * Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only MODEL 52H180 Storage Capacity (L) 180 Solar Collectors 1 SPA2000, NPT200, L Booster Type Electric or Gas Weight Empty (kg) - Tank 52 Hot Water Connection DN15 Compression Cold Water Connection DN15 Compression 105

Rheem Premier Hiline 52H 52H300 2-5 Outdoor 7 WYEAR CYLINDER A R R A N T Y Complete frost protection Space saving design a complete roof mounted installation Stainless steel cylinder Booster choice of electric element or 6-Star continuous flow gas Eligible for STCs 5 7 year cylinder warranty 1 with SPA2000, NPT200 10 year cylinder warranty 1 with L, CSA2007 collector* 563 2180 HOT TPR VALVE ELECTRICAL CONNECTION 79 2490 1937 2094 2198 * Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only MODEL 52H300 Storage Capacity (L) 300 Solar Collectors 1 SPA2000, NPT200, L Booster Type Electric or Gas Weight Empty - (kg) Tank 79 Hot Water Connection R 3 /4 Cold Water Connection RP 1 /2 106

Rheem Premier Hiline 300L 52C300 2-5 Outdoor Complete frost protection Energy efficient Booster choice of electric element or 6-Star continuous flow gas Suitable for a range of water supplies Eligible for STCs 5 5 year cylinder warranty 1 HOT T.P.R VALVE ELECTRICAL CONNECTION 77 508 2290 2475 1937 1022 2118 2425 MODEL 52C300 Storage Capacity (L) 300 Solar Collectors 2 NPT200 Booster Type Electric or Gas Weight Empty - (kg) Tank 109 Hot Water Connection DN15 Compression Cold Water Connection R 3 /4 107

Rheem Collectors NPT200, LCS, CSA2007, SPA2000, T200, CSA2612, L Outdoor B A PIPE WORK TO SOLAR COLLECTORS 2.0m 2 Collector A B 1 Collector 1240 1875 2 Collector 2360 1875 3 Collector 3480 1875 3 Collector 3480 1875 2.6m 2 Collector 1 Collector 1340 2165 COLLECTOR DATA Collector Dimension Weight Kg (empty) System NPT200 1943 x 1027 x 82 36 direct/indirect LCS 1943 x 1027 x 82 31 direct/indirect CSA2007 1996 x 1043 x 82 36 direct/indirect SPA2000 1996 x 1043 x 82 45 indirect T200 1943 x 1027 x 82 48 indirect CSA2612 2285 x 1130 x 82 47 direct L 1943 x 1027 x 82 29 direct/indirect 108

Conditions apply: 1 See the Rheem warranty in the product s Owner s Guide or view product warranties at www.rheem.com.au/warranty 2 Up to 42% lighter than comparable Rheem vitreous enamel water heater models of the same capacity. 3 60ºC and higher temperature models and some applications require a tempering valve in accordance with AS 3500.4. 4 Frost protection to 400m altitude above sea level 5 Eligibility criteria apply. 109

110

111 Heat Pump

112

HDi-310 551310 3-6 Outdoor Top Down heating No Solar collectors Energy efficient Back-up element Provides hot water regardless of the weather Fits on a compact footprint LED display to indicate operating status Eligible for STCs 5 5 year cylinder warranty 1 300 MIN 50 O 30 O 100 643 670 TPR VALVE WALL 300 MIN CONDENSATE DRAIN 679 VENTILATION CLEARANCE AIR AIR HOT 1870 1075 108 820 MODEL 551310 Storage Capacity (L) 310 Element Rating (kw) 3.6 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP 3 /4 Approx. Weight (Empty) kg 135 113

MPi-325 Series II 551325 2-5 Outdoor Multi-pass heating Heats the water by passing the water through the heat exchanger multiple times No Solar collectors Back up electric element One man installation can be fully installed by plumbing regular trades LED display to indicate operating status Eligible for STCs 5 5 year cylinder warranty 1 WALL 100 AIR 32 O TPR VALVE AIR 619 275 894 AIR 300 MIN 638 574 VENTILATION CLEARANCE CONDENSATE DRAIN HOT AIR VENTILATION CLEARANCE 300 min 114 1631 114 1317 AIR MODEL 551325 Storage Capacity (L) 325 Element Rating (kw) 3.6 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP 3 /4 Approx. Weight (Empty) kg 130 544 162 ELECTRICAL CONNECTION 1018 872

MPi-325 Series II 554325 2-5 Outdoor Inbuilt temperature control valve, adjustable to deliver 50ºC at first tap Multi-pass heating No Solar collectors Back up electric element One man installation can be fully installed by plumbing regular trades LED display to indicate operating status Eligible for STCs 5 5 year cylinder warranty 1 WALL 32 O TPR VALVE 100 AIR AIR 619 275 894 1006 AIR 300 MIN 638 574 VENTILATION CLEARANCE CONDENSATE DRAIN HOT AIR VENTILATION CLEARANCE 300 min 1636 114 1317 329 ELECTRICAL CONNECTION AIR 544 1018 872 MODEL 554325 Storage Capacity (L) 325 Element Rating (kw) 3.6 Relief Valve Setting (kpa) 1000 Expansion Control Valve (kpa) 850 Max Water Supply Pressure: with ECV (kpa) 680 without ECV (kpa) 800 Water Connections RP 3 /4 Approx. Weight (Empty) kg 130 115

Conditions apply: 1 See the Rheem warranty in the product s Owner s Guide or view product warranties at www.rheem.com.au/warranty 2 Up to 42% lighter than comparable Rheem vitreous enamel water heater models of the same capacity. 3 60ºC and higher temperature models and some applications require a tempering valve in accordance with AS 3500.4. 4 Frost protection to 400m altitude above sea level 5 Eligibility criteria apply. 116