Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Similar documents
TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Domestic fire sprinkler systems

Retrofitting AFSS in Social Housing Highrises

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Fire risk management plan. MH/05/Revised/06/17

Fire Safety. A TUC guide for trade union activists

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Information File. Sprinklers in Warehouses. Revision 3 June 2015 BIF 5

WELSH GOVERNMENT DOMESTIC FIRE SPRINKLER PILOT STUDY. Colin Blick Building Standards Technical Manager Welsh Government

WELSH GOVERNMENT SPRINKLER PILOT STUDY

Waking Watch / Common Fire Alarm. Guidance to support a temporary simultaneous evacuation strategy in a purpose-built block of flats

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

Automatic Sprinkler Systems Care and Maintenance

Association of Irish Risk Management An Introduction to Sprinklers 12th September 2012

Dangerous Assumptions

Fixed fire protection solutions

Fire Safety in HMOs - Automatic Fire Sprinklers Ian Gough, BAFSA

FIRE RISK ASSESSMENT AND PROTECTION

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

ISLE OF WIGHT FIRE & RESCUE SERVICE

NOTTINGHAM CITY HOMES

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Loss Prevention Standards

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire Risk Assessment. Do-it-Yourself ekit. Guidance Manual

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Fire Risk Assessment Safety Checklist

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

F I R E S A F E T Y R E G I S T E R

Electrical Safety Policy

Fire safety and high rise student accommodation

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Implementing the Domestic Fire Safety Regulations 2013

Fire Safety Protocol

Fire Management Guide

Policy for the Supply of Water to Automatic Fire Sprinkler Systems. October 2014

Water Heating UK 14 th May 2016

Statutory Compliance Checklist

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

MEDIUM-DENSITY HOUSING # 7. Fire safety

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005

Maintenance of Fire Systems

Policy for Safe Evacuation of Persons with Disabilities

Title: Room-sealed fanned draught flue systems concealed within voids

Lakanal House inquest: Statement from the Fire Sector Federation

Your specialist partner for total electrical compliance. Electrical Testing

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

The Macro Quallty Assurance System for Fire Safety Engineering

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response

Fire Performance of external thermal insulation for walls of multistorey buildings

A BARBOUR GUIDE. Fire Precautions and Fire Protection

Fire Risk Assessment Guidance

Consumer unit replacement in domestic and similar premises

fire risk assessment For use by landlords of small premises Premises Address

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

ESSEX POLICE, FIRE AND CRIME COMMISSIONER FIRE & RESCUE AUTHORITY Essex County Fire & Rescue Service

Bristol City Council Private Rented Sector Fire Safety Standards

Domestic and Residential Fire Sprinklers Design Policy

Storage Questionnaire

5 Key Stages to Risk Assessment

Fire Risk Management Policy. UK September 2017

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

Barnsley Accredited Landlord Scheme Accredited Property Registration Form

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

Fire Risk Assessment 2017

A basic guide to... Fire Safety for Scout Premises

Certificate No: EWS534

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Fire Safety Policy Date: 0

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Charlotte Building, 17 Gresse Street, London W1T 1QL

Installation and Maintenance Requirements

Personal Protection Systems (PPS)

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

Effectiveness of sprinklers in residential premises:

Fire Safety in Places of Worship An Insurers Perspective. Kevin Thomas, FCII, CFIRM Principal Risk Management Surveyor

Additional Requirements for Watermist Systems Protecting High-rise Buildings

EMERGENCY LIGHTING COMPLETION CERTIFICATE For small installations and verification of existing installations

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Thank you for your letter of 26 June regarding the Committee s scrutiny of building regulations in Scotland.

Fire Risk Assessment

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

Fire Sprinkler Courses

Transcription:

01 A sprinkler system is a pipework distribution system charged with water, with a network of heatsensitive sprinkler heads supplied via a tank/reservoir or a water main. If the temperature rises above a critical point, the sprinkler head will activate and a water spray will be emitted. Key points: only the sprinkler head or heads subject to the heat source will activate the sprinklers must be correctly rated according to the level of protection required/type of risk. Sprinkler systems are designed to control fires at a very early stage in their development and not necessarily to halt the advance of an already established fire. There is no general legal requirement for sprinkler systems to be installed in a place of work but there may be circumstances where sprinklers are required as detailed in the section below. There is no general legal requirement to install sprinklers in places of work have traditionally been installed in UK commercial buildings, particularly in warehouses with high-value stock. Residential sprinkler systems have been very unusual until recently, but are becoming more popular, particularly for developments where more vulnerable people reside or as an alternative to other requirements in order to meet the requirements of Building Regulations. The Welsh Assembly has introduced requirements for the installation of sprinklers in new and refurbished care homes, hostels and homes in multiple occupation since April 2014, and in all new dwellings since January 2016. In Scotland, since May 2005, all new care homes, sheltered housing and high-rise residential accommodation above 18 metres high have had to be fitted with sprinklers. In England, sprinklers have been required in new high rise buildings with floor levels in excess of 30 metres since 2007. Prior to the Grenfell Tower disaster, and particularly since, there have been calls for retrofitting of sprinklers in to high rise residential accommodation. Legal Requirements There is no general legal requirement to install sprinklers in places of work, although certain types of premises may require sprinkler systems under the requirements of the Building Regulations. However, properly maintained sprinkler systems are often required as a condition of insurance for high-risk premises. They may also be a necessary feature, as part of a suite of fire precautions, included in a building s design, to persuade Building Control Authorities to approve a building s layout. are often included to offset other parameters which would otherwise be unacceptable such as large unsegregated areas, high-rise buildings or long travel distances. Specific requirements regarding sprinklers apply to high-rise buildings in central London and in Wales. Where a fire safety risk assessment concludes that lifeprotection measures would not be sufficient without sprinkler provision, or the fire strategy for the building, as constructed required, sprinkler protection to offset other PAGE 1 > BARBOUR SAFE IN OUR KNOWLEDGE

features, then sprinklers and their maintenance effectively become a legal requirement under The Regulatory Reform (Fire Safety) Order 2005 and equivalent Country legislation. Following the Lakanal House high-rise housing fire in July 2009, in which six residents died, the coroner recommended that the retrofitting of sprinklers in high-rise housing blocks be considered. In 2011, the British Automatic Fire Sprinkler Association (BAFSA) sponsored a project in conjunction with Sheffield Council to retrofit sprinklers into an occupied 13 storey residential tower block to illustrate that this could be possible and achieved at a reasonable price. The project was achieved at a cost (2011 prices) of 1,150 per flat including the common water supplies. The annual maintenance cost for the whole block of 47 flats was estimated at 250 per year. The annualised total cost per flat of the installation and maintenance over a 30 year period, was considered to be 40 per flat. BAFSA published an update to the report following the Grenfell fire in 2017. Although some local authorities have retrofitted sprinklers to high rise residential accommodation, generally this was rare prior to the Grenfell House fire in June 2017, when 71 residents died in a fire which spread rapidly due to a combustible external cladding. The building was not fitted with sprinklers. Since this disaster, retrofitting of sprinklers in such high rise buildings has become more common and calls for the mandatory fitting of sprinklers in high rise residential buildings have been made. The current position is that in Scotland, since 2005, all new care homes, sheltered housing and high-rise residential accommodation above 18 metres high have had to be fitted with sprinklers. In addition, sprinklers are required in all covered shopping centres in Scotland. In Wales, since April 2014, all new and refurbished residential care homes, homes in multiple occupation and hostels (as well as certain other types of premises) must be fitted with an approved fire-suppression system. Since January 2016 all single-family dwellings in Wales, including houses and flats, must be protected with approved automatic fire-suppression systems. In England, since 2007, all newly constructed high rise buildings with floor levels in excess of 30 metres are required to be fitted with sprinklers. Information a. Brief System Description: All areas of the building to be protected are covered by a grid of pipes with sprinkler heads fitted at regular intervals. Water from a tank via pumps or from town main (if it can give sufficient flow) fills the pipes. Each sprinkler head is a heat-sensitive valve, which will open when it reaches a specific temperature and spray water onto the fire (on standard sprinkler systems, once activated, the head will remain open). The hot gases from a fire are usually enough to make it operate. The exact temperature of activation depends on the design criteria for the system, although generally the temperature set is 68oC with the exception of heads in areas exposed to high temperatures under normal conditions. Only the sprinklers over the heat source open; the others remain closed. As the water flows from the head, it strikes a deflector plate creating a water spray. Sprinkler heads can be placed in enclosed roof spaces and into floor ducts to protect areas where a fire can start without being noticed. In a large warehouse sprinklers may be placed in the storage racks as well as the roof. It is important that storage, and other obstructions within the area, do not come within close proximity as this will affect the ability of the sprinkler to quench the fire. Each system will have its own requirements but commonly the clearance distance for ceiling-mounted heads is 0.5 metres or more. The sprinkler heads are delicate and vulnerable to accidental damage. Managers of premises therefore need to ensure that working practices avoid accidental activation and the consequent water damage. At the point where the water enters the sprinkler system, or section of the system, there is a valve. This can be used to shut off the system for maintenance. For safety reasons, this should be kept locked open, and only authorised persons should be able to close it. If a sprinkler opens and water flows through the valve it lets water into a secondary pipe which hydraulically activates an alarm bell. Sprinkler systems are also commonly connected to the building fire alarm system via electrically operated pressure or flow switches. b. Types of Sprinkler System: The most common types of sprinkler system currently in use are: y Wet system: the whole system is full of water permanently to its design pressure allowing water to PAGE 2 > BARBOUR SAFE IN OUR KNOWLEDGE

Each sprinkler head is a heatsensitive valve be discharged immediately on activation of a sprinkler head. This is the most common system in use. y Dry system: these systems are permanently charged with air under pressure, and the resulting pressure drop on activation of a sprinkler head activates a water control valve. This should generally only be used where a wet or alternate wet and dry system cannot be used. y Alternate wet and dry system: the system is full of water during warm months and drained and charged with air under pressure in winter months where there may be a risk of freezing. When the system is charged with air it operates as described for dry systems above. y Pre-action system: this system incorporates an electronic form of detection to pre-arm the system with water. The system is generally filled with air under pressure, and activation of a sensor or detector lets water into the system. Water is then released into the space on activation of the sprinkler head. These are used in applications where it is not acceptable to have the pipework full of water at all times. c. Design and Maintenance: The sprinkler system is designed according to the hazard it is protecting against. The classifications within BS EN 12845:2015 are: industrial plant. Annex F of the standard contains provisions for additional measures to improve system reliability and availability. These measures are relevant in systems, for example installed for life safety reasons. The overall standards cover the classification of hazards, provision of water supplies, components to be used, installation and testing of the system and system maintenance. Another useful reference is LPC rules for automatic sprinkler installations. Compliance with these Rules is invariably specified if the sprinkler system is being installed as part of insurance requirements. The Rules incorporate the requirements of BS EN 12845 2015. The sprinkler system must be maintained in accordance with these codes. The installer should provide the client with details of inspection, servicing and maintenance requirements, which should be carried out by trained persons. It is common for weekly bell and alarm connection tests and checks to be carried out by in-house maintenance staff who have received suitable training, and for such work to be supported by an external specialist maintenance contractor who undertakes the more detailed tests and inspections which are required less frequently. A sufficient number of spare sprinkler heads should be kept available in accordance with the specification so that the system can promptly be put back into action following a fire. y Light hazard: This category covers low-risk nonindustrial applications. Typical examples are prisons, offices and schools. y Ordinary hazard: This category covers commercial and industrial applications involving ordinary combustible materials and is split into four further groups: Ordinary hazard Group 1 (includes hospitals, hotels and restaurants) Ordinary hazard Group 2 (includes laboratories, metal working factories and museums) Ordinary hazard Group 3 (includes most other types of factory, plant rooms, department stores, shopping centres and railway stations) Ordinary hazard Group 4 (includes tobacco factories, waste paper processing, theatres, cinemas and exhibition halls). y High hazard: This category covers commercial and industrial applications having abnormal fire hazards due to the activities taking place, the type of goods being stored etc; for example, paint factories, printing works and plastics injection-moulding factories are high hazard process 1 (HHP1). Firework factories are HHP4. BS EN 12845:2015 specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire-sprinkler systems in buildings and Records should be kept of all servicing, testing and maintenance. It is normal practice for insurers to place a warranty on the fire insurance policy where a premium discount is given for the installation of sprinklers, requiring the sprinklers to be maintained and the insurers to be notified if the system is not in service. Failure to comply with such a warranty will invalidate the insurance cover. Key Actions y Identify whether a sprinkler system is needed; such systems are particularly relevant to be considered as a retrofit in sheltered housing, care homes and high-rise residential buildings y ensure that, where a system is installed, it is inspected, serviced and maintained in accordance with the British Standard and the LPC Rules, by competent trained persons y ensure that design drawings of the sprinkler system, and as-built drawings, are retained y ensure that records are kept of all servicing, inspection and maintenance PAGE 3 > BARBOUR SAFE IN OUR KNOWLEDGE

y ensure that managers and staff are aware of the need to keep storage within identified boundaries so as to avoid compromising the sprinklers effectiveness y minimise the risk of sprinkler heads being damaged by identifying hazards and applying risk controls y ensure that, in shared or leased buildings, responsibilities for inspection, servicing and maintenance are clearly understood and allocated y ensure that control valve sets are kept padlocked in the open position using leather or similar straps (unless otherwise required), are protected from damage and that there is sufficient space for persons to work on them safely y maintain a sufficient supply of spare sprinkler heads y ensure that fire insurers are informed of any times when the sprinkler system is not operational and take what action the insurers require. Key Terms Sprinkler system - a pipework distribution system, usually charged with water, with a network of heat-sensitive sprinkler heads supplied via a tank/reservoir or a water main. Further Information and References http://www.bafsa.org.uk is the home page of the British Automatic Fire Sprinkler Association, the principal UK trade association for the fire sprinkler industry. The website contains information about sprinkler installations and a list of registered suppliers and installers. BS 9251:2014 Fire sprinkler systems for domestic and residential occupancies - Code of practice. Components for such systems should comply with BS 9252 2011 Components for residential sprinkler systems - Specifications and Test Methods for Residential. BS EN 12845:2015 Fixed firefighting systems: automatic sprinkler systems: design, installation and maintenance. BS 9999:2017 Code of Practice for Fire Safety in Design, Management and Use of Buildings. Safer High Rise Living- the Callow Mount Sprinkler Retrofit Project BAFSA 2012 There is also a full range of equipment British Standards for sprinkler system components. Date of Review: February 2018 Sprinkler head - a heat-sensitive valve which will open when it reaches a specific temperature and spray water onto the fire. Related Documents Building Regulations Approved Document B Fire Safety (or National Equivalent), Volume 1 and 2 2006 incorporating 2010 and 2013 amendments. LPC Rules for Automatic Sprinkler Installations: Incorporating BSEN 12845: including current technical bulletins 2015. Systems for Fire Protection of Commercial and Industrial Buildings BRE Digest 518 2010. PAGE 4 > BARBOUR SAFE IN OUR KNOWLEDGE

Disclaimer Barbour is a trading division and trading name of UBM (UK) Limited. It has published this Guide in order to help the promotion of good practice amongst knowledgeable and competent specialists in the subject covered by this Guide. By using this Guide, the user acknowledges, accepts and agrees to the following: UBM (UK) Limited does not give any condition, warranty or other term, or accept any duty of care or liability, in connection with the quality or fitness for purpose of this Guide, or any loss or damage resulting from reliance on it, and it excludes all these. When deciding whether or how to act, the user should always obtain appropriate professional advice and should not rely on any information, advice or recommendation in this Guide, however it has been expressed. The user is responsible for obtaining professional advice, and acknowledges that any defects in this Guide would be detected by a knowledgeable and competent specialist providing that advice. Any use of this Guide by any person is subject to UBM (UK) Limited s user terms for Barbour services, and by using it the user is accepting those terms, and agreeing to be bound by them, on behalf of the user and all other persons for whom the user undertakes any work. The user waives (and agrees to waive) all claims for loss or damage which it might otherwise have against UBM (UK) Limited in connection with this Guide other than those arising out of a liability which UBM (UK) Limited has for personal injury (whether fatal or otherwise) resulting from negligence. PAGE 5 > BARBOUR SAFE IN OUR KNOWLEDGE