User manual PRO range display chillers and display freezers

Similar documents
User manual To ensure safe operation, please read this user manual thoroughly before use.

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

User manual: Stainless steel CSS1 Refrigerator and FSS2 Freezer

Husky Refrigerator. Owner Manual ENGLISH. To ensure safe operation, please read this instruction manual thoroughly before use. For illustration only.

Husky Drinks Cooler. Owner Manual ENGLISH. To ensure safe operation, please read this instruction manual thoroughly before use. For illustration only.

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

Husky HN7 Reflections Dual-Zone Wine Cooler

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

Model Modèle Modell Modello Modelo Malli:

Bar Fridge USER MANUAL MB46W

Freestanding Wine Cooler Instruction Manual

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

FWC153, FWC304, FWC604 & FWC624

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

FWC860 Wine Cooler Installation, Use and Maintenance

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

IMPORTANT: RETAIN FOR FUTURE REFERENCE

BAR FRIDGE MODEL:FF.69L

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

USER GUIDE R5010W/R5010B R5510W/R5510B/R5510S

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

INSTALLATION & OPERATION INSTRUCTIONS

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

INSTRUCTION MANUAL FOR WINE COOLER

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Vinobox C 50 1T Vinobox C 50 2T

LEC L6014W/S User Manual

User Manual. Commercial Refrigerator And Freezer User s Manual

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Instruction / Installation Manual. Fridge Freezer LFC60W13

FR-031DDRVBE1 FR-031DDRVWE

AWC150, AWC300 & AWC600

Instruction Manual. Refrigerator. Model: HS-65L

Outdoor Beverage Center

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User Manual. Refrigerator ZRG16605WA

HR6BF170R HR6BF170B HR6BF170G

Double Door - Dual Zone Wine Cooler

HR6BMFF320 HR6BMFF320S

ST NF60188W ST NF60188STA

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

V 120 SG - V 160 SG. Instructions for use

Cabinet Refrigerators/Freezers Instruction manual

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

RCB53724MW RCB53724MX RCB53724VW RCB53724VX. User Manual Fridge Freezer USER MANUAL

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL)

Mobile Air Conditioner Instruction Manual Model TC-N9KM

INSTRUCTION MANUAL FOR WINE COOLER

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

IMPORTANT: RETAIN FOR FUTURE REFERENCE

Wine Cooler CVD121V/CVD131V/CVD130/CVD120

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

EURO APPLIANCES BY EUROSTYLE GROUP

TWLRZ-238 REFRIGERATOR

Glass Door Refrigerators

ER MANUAL FOR YOUR BAUMATIC

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Stainless Steel Counter Refrigerators Instruction manual

User Manual. Freezer ZFT11112WE

OPERATING INSTRUCTIONS:!

Refrigerator Freezer HD-368RWEW

Bistro Contact Grill Instruction manual

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

WINE COOLER BUIT-IN DUAL-ZONE BE A PRO IN YOUR KITCHEN. K430D Bottles INSTALLATION GUIDE AND USER MANUAL. APPLICABLE MODEL: KD430D

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

User Manual. Chest Freezer ZFC26500WA

WHS-65LB1/WHS-65LW1/WHS-65LSS1

Silver Undercounter Larder Fridge

Beverage Air IMPORTANT

User Instruction &)+ 4: CFH110QB

Refrigerator INSTRUCTION MANUAL W1BF17 & W1WF17

Built-in Larder Fridge

Up to 60 Pint Commercial Grade DEHUMIDIFIER

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

User Manual FRCLF185W CONTENTS. Safety information...2 Safety instructions... 4 Product description...6 Operation...7 Daily use...

FR120RC/FR120RM FR120RR/FR120RB FN-153/FN-153C

WARNING/SAFETY PRECAUTIONS

V150 SG2E / V190 SG2E. Instructions for use

CZ51202 Larder fridge

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

Thank you for buying this refrigerator-freezer. To ensure that you get the best

LARDER FRIDGE RBL1A FREEZER RBF1A

GLASS DOOR BAR FRIDGE

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual

TM585. Refrigerator - Freezer Operation manual. Contents

CHEST FREEZER USER GUIDE LEC CF61LW

Transcription:

User manual PRO range display chillers and display freezers To ensure safe operation, please read this user manual thoroughly before use. 2017 Husky. Husky reserve the right to change specifications at any time without notice. Images used are for illustration only. Stock not included. International PRO upright manual 240317 EDITION 2 v2.indd 1 28/03/2017 08:34

Welcome to your new Husky Thank you for buying this Husky commercial chiller/freezer. It has been designed and manufactured for many years of trouble-free service. Operation is very simple, but please take a few minutes to read this user manual. It contains important safety information, and tips to ensure you receive the best possible service from your Husky unit. CONTENTS Important Notes...3 Warning! Risk of electrical shock hazard...3 Disposal of old refrigerators...3 Safety instructions and warnings...3 Before using for the first time...4 Troubleshooting...5 Standard Range C4PRO, C5PRO, C8PRO, & C10PRO...6 Operating Instructions...6 Exploded diagram...7 Circuit diagrams...9 Wiring diagram...11 Intelligenzia Range C4PRO-IT, C5PRO-IT, C8PRO-IT, & C10PRO-IT...12 Operating Instructions...12 Exploded diagram...13 Circuit diagrams...15 Wiring diagram...17 Below Zero Range C4PRO-ZZ, C5PRO-ZZ, C8PRO-ZZ & C10PRO-ZZ...18 Operating Instructions...18 Exploded diagram...19 Circuit diagrams and wiring diagram...21 Cassette Range C4PRO-CA, C5PRO-CA & C10PRO-CA...22 Operating Instructions...22 Exploded diagram...23 Circuit diagrams...25 Wiring diagram...27 Freezer Range F5PRO & F10PRO...28 Operating Instructions...28 Exploded diagram...29 Circuit diagrams...31 Wiring diagram...31 2 International PRO upright manual 240317 EDITION 2 v2.indd 2 28/03/2017 08:34

All models Important Notes WARNING: RISK OF ELECTRICAL SHOCK HAZARD This refrigeration unit must be earthed. If the power cable is damaged, it must be replaced by a qualified engineer to avoid shock hazard. DO NOT ATTEMPT TO SERVICE THE ITEM YOURSELF. Ensure that the unit is properly earthed. Stop using the unit immediately if electric shock is felt when touching the cabinet. DISPOSAL OF OLD REFRIGERATORS & FREEZERS BE SURE TO MAKE ANY LOCKS UNUSABLE. IF POSSIBLE, REMOVE THE DOOR(S) AND DISCARD SEPARATELY. WARNING CHEMICAL HAZARD: DO NOT ALLOW CHILDREN TO PLAY WITH OLD REFRIGERATORS OR FREEZERS. CONTACT YOUR LOCAL AUTHORITY FOR PROPER DISPOSAL PROCEDURES. Before disposing of an old refrigerator or freezer, please make sure it is switched off and safe. Unplug the unit and break any locks in order to avoid children becoming trapped. Please note: the refrigeration system contains gases and refrigerants which require specialist waste disposal. The valuable materials contained in a refrigerator or freezer can be recycled. Contact your local waste disposal depot for proper disposal of an old unit and contact your local authority or dealer if you have any questions. Ensure the pipework of the old unit is not damaged prior to disposal. You can contribute to the environmental awareness by insisting on an appropriate non-polluting method of disposal. USERS IN EUROPE WEEE COMPLIANCE Husky chillers and freezers are authorised to carry the CE (Conformité Européene) and WEEE (Waste Electrical and Electronic Equipment Directive) symbols. The WEEE symbol on this chiller/freezer indicates that the product must not be disposed of with household waste. To help prevent possible harm to health and the environment, the product must be disposed of by recycling methods authorised as environmentally safe. For more information on how to dispose of this product appropriately, contact your dealer or the recycling department at your local authority. Husky chillers/freezers and their components undergo strict product testing by independent companies to comply or exceed all applicable local and international regulatory standards. SAFETY INSTRUCTIONS & WARNINGS Before switching on your Husky commercial chiller or freezer, read the information in this user manual carefully. The user manual contains important observa tions relating to the assembly, operation and maintenance of the unit. Please keep this user manual in a safe place for future reference. If you ever sell this unit, hand this user manual to the new owner. 3 International PRO upright manual 240317 EDITION 2 v2.indd 3 28/03/2017 08:34

The manufacturer does not accept responsibility for any damages that may arise due to nonobservation of these instructions. Do not use the unit if it is damaged. If you are in any doubt, consult an engineer. Connection and installation of your Husky unit are to be carried out in strict compliance with the relevant instructions in this user manual. Make sure there is a suitable power outlet with proper grounding to power the unit. For safety, the unit must be properly earthed in accordance with specifications. Always remember to unplug the unit before cleaning. Never unplug this unit by pulling on the power cable. Always grip plug firmly and pull straight out from the socket. All electrical repairs must be carried out by a qualified engineer. Inadequate repairs may be dangerous. Do not damage any parts of the chiller/freezer which carry refrigerant by piercing, perforating, crushing, twisting or scraping. If refrigerant comes into contact with the eyes it may cause serious eye injury. Do not obstruct or cover the ventilation grille. Do not allow children to play with the unit, or to sit on it or hang onto the door. This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabil ities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety. BEFORE USING FOR THE FIRST TIME IMPORTANT: Before switching the unit on, we recommend you allow it to stand upright for 8 hours. Failure to do this may result in damage to the unit. Remove the wooden pallet and the packing. To ensure correct operation, it is important that the unit is level. The cabinet may be levelled by turning either or both of the adjustable feet in the front corners. Use a spirit level to check. Before operation, we recommend that the cabinet is cleaned for reasons of hygiene and to remove any residue left from manufacture. For good circulation, vents must not be blocked. Keep a minimum of 100mm of clear space around the chiller/freezer. Your Husky unit should be placed on flat and firm surface for quieter operation. Do not expose the unit to direct sunlight or a heat source such as ovens, radiators, heaters, etc. Do not under any circumstances place heated food or beverages in your Husky commercial chiller/freezer. Do not open the door more often than necessary to lessen the escape of cold air. For better air circulation, do not overfill the unit. Adjust the thermostat according to the amount of product and the ambient temperature. 4 International PRO upright manual 240317 EDITION 2 v2.indd 4 28/03/2017 08:34

Troubleshooting Before calling Technical Support, please check the following points; you may be able to solve any problem yourself. Problem The chiller/freezer does not work properly. The chiller or freezer s internal temperature is too high or too low. The chiller/freezer is noisy in operation or makes unusual noises. Note: It is normal to hear some noises as refrigerant flows through the compressor. Outer surfaces are wet Inner surfaces are wet Possible Cause The unit is not plugged in. The plug and/or the power cable are faulty. The fuse has blown. The unit is faulty. The wrong temperature is selected. The factory default settings for the controller are incorrect. The condenser is blocked by an accumulation of dust. The doors are not fully closed. The chiller/freezer is close to a heat source or the ambient temperature is too high. The ventilation grille is blocked. The unit is not on a level, firm surface, or the unit may be touching other items. The chiller/freezer is vibrating against a neighbouring object. The unit may be close to a water source or leak. The door may be opened too often or kept open too long. Action Connect the plug to the power supply Call your supplier or a qualified engineer. Replace the fuse with one of the same rating. Call your supplier or a qualified engineer. Check the controller and adjust the set temperature. Call your supplier or a qualified engineer. Clean using a vacuum cleaner and soft brush attachment (see pages 8, 14, 20, or 24) Check the unit is level and the seals are not damaged. Move the unit to a better location and check it is out of direct sunlight. Move the chiller to improve free movement of air. Check location and position using a spirit level. Relocate the chiller or the object. Dry surfaces thoroughly and move the unit. Try to minimise opening of the doors for better cooling performance. 5 International PRO upright manual 240317 EDITION 2 v2.indd 5 28/03/2017 08:34

Standard Range C4PRO, C5PRO, C8PRO, & C10PRO Operating Instructions TO OPERATE THE ELECTRONIC THERMOSTAT The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings. When the unit is operating normally, the display will show the current temperature. To display the set temperature press the button. Press the button again to return to normal operation. To set a new temperature, press. The display will flash and the current set temperature will be displayed. Press the button to increase the set temperature, or press the button to decrease the set temperature. Press the button to save the new setting. The display will flash with the new value and then revert to display the cabinet temperature. Please note: 1. When the chiller is connected to the mains for the first time there will be a short delay before cooling starts. During this time the Refrigeration Light will flash. After the short delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller reaches the set temperature, the Refrigeration Light will be off. 2. If you do not press any button, after six seconds the controller will return to its normal display. To switch the chiller off, press for six seconds. The display will show - - -. To switch the chiller back on, press for one second. The display will show the cabinet temperature and the unit will enter normal working mode. DEFROSTING The unit defrosts automatically at preset intervals. If however the door is opened too often, or if the unit is in a location with high humidity, or if the contents are changed more frequently, it may be necessary to defrost the unit manually. To start or stop manual defrosting, press the button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a container placed in the compressor compartment and evaporates. After defrosting is complete, the unit will return to normal operation. INTERIOR LIGHT Press the button to switch the light on or off. EVAPORATOR FAN As part of the chiller s normal operation the evaporator fan will switch off automatically when 6 International PRO upright manual 240317 EDITION 2 v2.indd 6 28/03/2017 08:34

Exploded Diagram 7 International PRO upright manual 240317 EDITION 2 v2.indd 7 28/03/2017 08:34

Standard Range C4PRO, C5PRO, C8PRO, & C10PRO the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 7). INSTALLING SHELVES Fit the shelf clips to the ladder racks (see Fig. 2 on page 7) and install the shelves horizontally. Ensure the clips are located firmly and the shelves are secure before loading the chiller. FITTING/REMOVING THE ILLUMINATED CANOPY QUALIFIED ENGINEERS ONLY. To fit the canopy, first disconnect the chiller from the power supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now be seen. See Fig. 1 on page 7. Tighten the thumb screws on both sides of the canopy to secure the canopy to the chiller. Re-connect the chiller to the power supply. To remove the canopy, first disconnect the chiller from the power supply. Loosen the thumb screws on both sides of canopy, then pull out the plug for the canopy light see Fig. 1 on page 7. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally re-connect the chiller to the power supply. EASY MAINTENANCE ACCESS QUALIFIED ENGINEERS ONLY. Husky chillers are designed for easy maintenance. One feature is that the compressor, condenser and condenser fan are mounted on an easilyaccessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two screws (which have now become accessible) on the top on either side of the kick plate see Fig 5 on page 7. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb screws on either side of the sliding tray see Fig. 4 on page 7. With caution slide out the sliding tray no more than 300mm. COMPRESSOR QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray see Easy Maintenance Access. CLEANING The condenser and the compressor compartment MUST be cleaned quarterly see Easy Maintenance Access how to access the compressor compartment. The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on page 7). Clean the external and internal surfaces of the unit with a mild soap solution, then wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use mild soapy water to clean the gasket and seals. GETTING SERVICE ASSISTANCE The cooling system is a hermetically sealed circuit and does not require any maintenance other than regular cleaning (see Cleaning ). If the unit fails to work, first check the power supply. If you cannot locate the reason for the failure, please contact your supplier, stating the model and serial number of the cabinet. You may find this information on the rating plate, which is affixed inside the unit on the top right-hand interior wall. 8 International PRO upright manual 240317 EDITION 2 v2.indd 8 28/03/2017 08:34

Circuit Diagrams C4PRO & C5PRO Standard models, no canopy C4PRO & C5PRO Standard models with canopy C8PRO & C10PRO Standard models, no canopy 9 International PRO upright manual 240317 EDITION 2 v2.indd 9 28/03/2017 08:34

Standard Range C4PRO, C5PRO, C8PRO, & C10PRO Circuit Diagrams C8PRO & C10PRO Standard models with canopy C8PRO & C10PRO Standard models with door heater, no canopy C8PRO & C10PRO Standard models with door heater and canopy 10 International PRO upright manual 240317 EDITION 2 v2.indd 10 28/03/2017 08:34

Wiring Diagram ELECTRONIC THERMOSTAT SF-102SBQ-4 11 International PRO upright manual 240317 EDITION 2 v2.indd 11 28/03/2017 08:34

Intelligenzia Range C4PRO-IT, C5PRO-IT, C8PRO-IT, & C10PRO-IT Operating Instructions TO OPERATE THE ELECTRONIC THERMOSTAT The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings. When the unit is operating normally, the display will show the current temperature. To display the set temperature press the button. Press the button again to return to normal operation. To set a new temperature, press. The display will flash and the current set temperature will be displayed. Press the button to increase the set temperature, or press the button to decrease the set temperature. Press the button to save the new setting. The display will flash with the new value and then revert to display the cabinet temperature. Please note: 1. When the chiller is connected to the mains for the first time there will be a short delay before cooling starts. During this time the Refrigeration Light will flash. After the short delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller reaches the set temperature, the Refrigeration Light will be off. 2. If you do not press any button, after six seconds the controller will return to its normal display. DEFROSTING The unit defrosts automatically at preset intervals. If however the door is opened too often, or if the unit is in a location with high humidity, or if the contents are changed more frequently, it may be necessary to defrost the unit manually. To start or stop manual defrosting, press the button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a container placed in the compressor compartment and evaporates. After defrosting is complete, the unit will return to normal operation. INTELLIGENZIA MODE The Husky Intelligenzia range is designed for superior energy efficiency. If the chiller is not opened for two hours, the unit enters its energy-saving Intelligenzia mode. The evaporator fan and compressor will stop, and the internal temperature will increase from 4 C to 9 C. All these features are part of the Intelligenzia range s normal operation. INTERIOR LIGHT Press the button to switch the light on or off. 12 International PRO upright manual 240317 EDITION 2 v2.indd 12 28/03/2017 08:34

Exploded Diagram 13 International PRO upright manual 240317 EDITION 2 v2.indd 13 28/03/2017 08:34

Intelligenzia Range C4PRO-IT, C5PRO-IT, C8PRO-IT, & C10PRO-IT EVAPORATOR FAN As part of the chiller s normal operation the evaporator fan will switch off automatically when the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 13). INSTALLING SHELVES Fit the shelf clips to the ladder racks (see Fig. 2 on page 13) and install the shelves horizontally. Ensure the clips are located firmly and the shelves are secure before loading the chiller. FITTING/REMOVING THE ILLUMINATED CANOPY QUALIFIED ENGINEERS ONLY. To fit the canopy, first disconnect the chiller from the power supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now be seen. See Fig. 1 on page 13. Tighten the thumb screws on both sides of the canopy to secure the canopy to the chiller. Re-connect the chiller to the power supply. To remove the canopy, first disconnect the chiller from the power supply. Loosen the thumb screws on both sides of canopy, then pull out the plug for the canopy light see Fig. 1 on page 13. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally re-connect the chiller to the power supply. EASY MAINTENANCE ACCESS QUALIFIED ENGINEERS ONLY. Husky chillers are designed for easy maintenance. One feature is that the compressor, condenser and condenser fan are mounted on an easilyaccessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two screws (which have now become accessible) on the top on either side of the kick plate see Fig 5 on page 13. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb screws on either side of the sliding tray see Fig. 4 on page 13. With caution slide out the sliding tray no more than 300mm. COMPRESSOR QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray see Easy Maintenance Access. CLEANING The condenser and the compressor compartment MUST be cleaned quarterly see Easy Maintenance Access how to access the compressor compartment. The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on page 13). Clean the external and internal surfaces of the unit with a mild soap solution, then wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use mild soapy water to clean the gasket and seals. GETTING SERVICE ASSISTANCE The cooling system is a hermetically sealed circuit and does not require any maintenance other than regular cleaning (see Cleaning ). If the unit fails to work, first check the power supply. If you cannot locate the reason for the failure, please contact your supplier, stating the model and serial number of the cabinet. You may find this information on the rating plate, which is affixed inside the unit on the top right-hand interior wall. 14 International PRO upright manual 240317 EDITION 2 v2.indd 14 28/03/2017 08:34

Circuit Diagrams C4PRO & C5PRO Intelligenzia/Intelligenzia Cassette models, no canopy C4PRO & C5PRO Intelligenzia/Intelligenzia Cassette models with canopy C8PRO & C10PRO Intelligenzia/Intelligenzia Cassette models, no canopy 15 International PRO upright manual 240317 EDITION 2 v2.indd 15 28/03/2017 08:34

Intelligenzia Range C4PRO-IT, C5PRO-IT, C8PRO-IT, & C10PRO-IT Circuit Diagrams C8PRO & C10PRO Intelligenzia/Intelligenzia Cassette models with canopy C8PRO & C10PRO Intelligenzia/Intelligenzia Cassette models with door heater, no canopy C8PRO & C10PRO Intelligenzia/Intelligenzia Cassette models with door heater and canopy 16 International PRO upright manual 240317 EDITION 2 v2.indd 16 28/03/2017 08:34

Wiring Diagram ELECTRONIC THERMOSTAT SF-402 17 International PRO upright manual 240317 EDITION 2 v2.indd 17 28/03/2017 08:34

Below Zero Range C4PRO-ZZ, C5PRO-ZZ, C8PRO-ZZ & C10PRO-ZZ Operating Instructions IMPORTANT: The Husky Below Zero range is designed to blast chill beverages only down to -3 C. Do not store food or medicines in a Below Zero cabinet under any circumstances. TO OPERATE THE ELECTRONIC THERMOSTAT The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings. When the unit is operating normally, the display will show the current temperature. To display the set temperature press the button. Press the button again to return to normal operation. To set a new temperature, press. The display will flash and the current set temperature will be displayed. Press the button to increase the set temperature, or press the button to decrease the set temperature. Press the button to save the new setting. The display will flash with the new value and then revert to display the cabinet temperature. Please note: 1. When the chiller is connected to the mains for the first time there will be a short delay before cooling starts. During this time the Refrigeration Light will flash. After the short delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller reaches the set temperature, the Refrigeration Light will be off. 2. If you do not press any button, after six seconds the controller returns to normal display. DEFROSTING The unit defrosts automatically at preset intervals. If however the door is opened too often, or if the unit is in a location with high humidity, or if the contents are changed more frequently, it may be necessary to defrost the unit manually. To start or stop manual defrosting, press the button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a container placed in the compressor compartment and evaporates. After defrosting is complete, the unit will return to normal operation. INTERIOR LIGHT Press the button to switch the light on or off. 18 International PRO upright manual 240317 EDITION 2 v2.indd 18 28/03/2017 08:34

Exploded Diagram 19 International PRO upright manual 240317 EDITION 2 v2.indd 19 28/03/2017 08:34

Below Zero Range C4PRO-ZZ, C5PRO-ZZ, C8PRO-ZZ & C10PRO-ZZ EVAPORATOR FAN As part of the chiller s normal operation the evaporator fan will switch off automatically when the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 19). INSTALLING SHELVES Fit the shelf clips to the ladder racks (see Fig. 2 on page 19) and install the shelves horizontally. Ensure the clips are located firmly and the shelves are secure before loading the chiller. FITTING/REMOVING THE ILLUMINATED CANOPY QUALIFIED ENGINEERS ONLY. To fit the canopy, first disconnect the chiller from the power supply. Remove the right hand door hinge cover. Plug the canopy light and the LED display into the sockets that may now be seen. See Fig. 1 on page 19. Tighten the thumb screws on both sides of the canopy to secure the canopy to the chiller. Re-connect the chiller to the power supply. To remove the canopy, first disconnect the chiller from the power supply. Loosen the thumb screws on both sides of canopy, then pull out the two plugs for the canopy light and LED display see Fig. 1 on page 19. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally re-connect the chiller to the power supply. EASY MAINTENANCE ACCESS QUALIFIED ENGINEERS ONLY. Husky chillers are designed for easy maintenance. One feature is that the compressor, condenser and condenser fan are mounted on an easilyaccessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two screws (which have now become accessible) on the top on either side of the kick plate see Fig 5 on page 19. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb screws on either side of the sliding tray see Fig. 4 on page 19. With caution slide out the sliding tray no more than 300mm. COMPRESSOR QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray see Easy Maintenance Access. CLEANING The condenser and the compressor compartment MUST be cleaned quarterly see Easy Maintenance Access how to access the compressor compartment. The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on page 19). Clean the external and internal surfaces of the unit with a mild soap solution, then wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use mild soapy water to clean the gasket and seals. GETTING SERVICE ASSISTANCE The cooling system is a hermetically sealed circuit and does not require any maintenance other than regular cleaning (see Cleaning ). If the unit fails to work, first check the power supply. If you cannot locate the reason for the failure, please contact your supplier, stating the model and serial number of the cabinet. You may find this information on the rating plate, which is affixed inside the unit on the top right-hand interior wall. 20 International PRO upright manual 240317 EDITION 2 v2.indd 20 28/03/2017 08:34

Circuit Diagrams C4PRO-ZZ & C5PRO-ZZ Below Zero model C8PRO-ZZ & C10PRO-ZZ Below Zero, no canopy C8PRO-ZZ & C10PRO-ZZ Below Zero with canopy Wiring Diagram ELECTRONIC THERMOSTAT SF-104SB 21 International PRO upright manual 240317 EDITION 2 v2.indd 21 28/03/2017 08:34

Cassette Range C4PRO-CA, C5PRO-CA, C8PRO-CA & C10PRO-CA Operating Instructions TO OPERATE THE ELECTRONIC THERMOSTAT The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings. When the unit is operating normally, the display will show the current temperature. To display the set temperature press the button. Press the button again to return to normal operation. To set a new temperature, press. The display will flash and the current set temperature will be displayed. Press the button to increase the set temperature, or press the button to decrease the set temperature. Press the button to save the new setting. The display will flash with the new value and then revert to display the cabinet temperature. Please note: 1. When the chiller is connected to the mains for the first time there will be a short delay before cooling starts. During this time the Refrigeration Light will flash. After the short delay, cooling will begin and the Refrigeration Light will be illuminated. When the chiller reaches the set temperature, the Refrigeration Light will be off. 2. If you do not press any button, after six seconds the controller will return to its normal display. To switch the chiller off, press for six seconds. The display will show - - -. To switch the chiller back on, press for one second. The display will show the cabinet temperature and the unit will enter normal working mode. DEFROSTING The unit defrosts automatically at preset intervals. If however the door is opened too often, or if the unit is in a location with high humidity, or if the contents are changed more frequently, it may be necessary to defrost the unit manually. To start or stop manual defrosting, press the button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a container placed in the compressor compartment and evaporates. After defrosting is complete, the unit will return to normal operation. INTERIOR LIGHT Press the button to switch the light on or off. 22 International PRO upright manual 240317 EDITION 2 v2.indd 22 28/03/2017 08:34

Exploded Diagram 23 International PRO upright manual 240317 EDITION 2 v2.indd 23 28/03/2017 08:34

Cassette Range C4PRO-CA, C5PRO-CA, C8PRO-CA & C10PRO-CA EVAPORATOR FAN As part of the chiller s normal operation the evaporator fan will switch off automatically when the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 23). INSTALLING SHELVES Fit the shelf clips to the ladder racks (see Fig. 2 on page 23) and install the shelves horizontally. Ensure the clips are located firmly and the shelves are secure before loading the chiller. COMPRESSOR SLED CASSETTE MODELS ONLY QUALIFIED ENGINEERS ONLY. Husky chillers are designed for easy maintenance. The Husky Cassette Range has all major components mounted on a sliding cassette which can be removed in moments. First, switch the unit off and disconnect the plug from the mains socket. To remove the kick plate, remove two screws on the top and one screw on either side of the kick plate see Fig. 5 on page 23. Then remove the kick plate. Four plugs will now be visible -- one each for the power, the light, the fan and the middle door post heater. Disconnect all four plugs see Fig. 4. At the front on the cassette is a locking bracket in a vertical position. Rotate the locking bracket by 90 see Fig. 3. You may now slide the complete cassette out. To reassemble the unit, follow the above instructions in reverse order, ensuring locking bracket is returned to its vertical position. FITTING/REMOVING THE ILLUMINATED CANOPY QUALIFIED ENGINEERS ONLY. To fit the canopy, first disconnect the chiller from the power supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now be seen. See Fig. 1 on page 23. Tighten the thumb screws on both sides of the canopy to secure the canopy to the chiller. Re-connect the chiller to the power supply. To remove the canopy, first disconnect the chiller from the power supply. Loosen the thumb screws on both sides of canopy, then pull out the plug for the canopy light see Fig. 1 on page 23. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally re-connect the chiller to the power supply.. CLEANING The condenser and the compressor compartment MUST be cleaned quarterly see Compressor Sled Cassette models only how to access the compressor compartment. The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off and disconnect the plug from the mains socket. Remove the drainage hole cover. Clean the external and internal surfaces of the unit with a mild soap solution, then wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use mild soapy water to clean the gasket and seals. GETTING SERVICE ASSISTANCE The cooling system is a hermetically sealed circuit and does not require any maintenance other than regular cleaning (see Cleaning ). If the unit fails to work, first check the power supply. If you cannot locate the reason for the failure, please contact your supplier, stating the model and serial number of the cabinet. You may find this information on the rating plate, which is affixed inside the unit on the top right-hand interior wall. 24 International PRO upright manual 240317 EDITION 2 v2.indd 24 28/03/2017 08:34

Circuit Diagrams C4PRO & C5PRO Standard Cassette model, no canopy C4PRO & C5PRO Standard Cassette model with canopy C8PRO & C10PRO Standard Cassette models, no canopy 25 International PRO upright manual 240317 EDITION 2 v2.indd 25 28/03/2017 08:34

Cassette Range C4PRO-CA, C5PRO-CA, C8PRO-CA & C10PRO-CA Circuit Diagrams C8PRO & C10PRO Standard Cassette models with canopy C8PRO & C10PRO Standard Cassette models with door heater, no canopy C8PRO & C10PRO Standard Cassette models with door heater and canopy 26 International PRO upright manual 240317 EDITION 2 v2.indd 26 28/03/2017 08:34

Wiring Diagram ELECTRONIC THERMOSTAT SF-102SBQ-4 27 International PRO upright manual 240317 EDITION 2 v2.indd 27 28/03/2017 08:34

Freezer Range F5PRO & F10PRO Operating Instructions TO OPERATE THE ELECTRONIC THERMOSTAT The thermostat has been pre-set, and in most cases it is not necessary to adjust the settings. When the unit is operating normally, the display will show the current temperature. To display the set temperature press the button. Press the button again to return to normal operation. To set a new temperature, press. The display will flash and the current set temperature will be displayed. Press the button to increase the set temperature, or press the button to decrease the set temperature. Press the button to save the new setting. The display will flash with the new value and then revert to display the cabinet temperature. Please note: 1. When the freezer is connected to the mains for the first time there will be a short delay before cooling starts. During this time the Refrigeration Light will flash. After the short delay, cooling will begin and the Refrigeration Light will be illuminated. When the freezer reaches the set temperature, the Refrigeration Light will be off. 2. If you do not press any button, after six seconds the controller will return to its normal display. To switch the freezer off, press for six seconds. The display will show - - -. To switch the freezer back on, press for one second. The display will show the cabinet temperature and the unit will enter normal working mode. DEFROSTING The unit defrosts automatically at preset intervals. If however the door is opened too often, or if the unit is in a location with high humidity, or if the contents are changed more frequently, it may be necessary to defrost the unit manually. To start or stop manual defrosting, press the button for six seconds. The Defrosting Light will be illuminated. Melt water runs to a container placed in the compressor compartment and evaporates. After defrosting is complete, the unit will return to normal operation. INTERIOR LIGHT Press the button to switch the light on or off. EVAPORATOR FAN As part of the freezer s normal operation the evaporator fan will switch off automatically when 28 International PRO upright manual 240317 EDITION 2 v2.indd 28 28/03/2017 08:34

Exploded Diagram 29 International PRO upright manual 240317 EDITION 2 v2.indd 29 28/03/2017 08:34

Freezer Range F5PRO & F10PRO the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 29). INSTALLING SHELVES Fit the shelf clips to the ladder racks (see Fig. 2 on page 29) and install the shelves horizontally. Ensure the clips are located firmly and the shelves are secure before loading the freezer. FITTING/REMOVING THE ILLUMINATED CANOPY COMPETENT PERSON ONLY. To fit the canopy, first disconnect the freezer from the power supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now be seen. See Fig. 1 on page 29. Tighten the thumb screws on both sides of the canopy to secure the canopy to the freezer. Re-connect the freezer to the power supply. To remove the canopy, first disconnect the freezer from the power supply. Loosen the thumb screws on both sides of canopy, then pull out the plug for the canopy light see Fig. 1 on page 29. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally re-connect the freezer to the power supply. EASY MAINTENANCE ACCESS QUALIFIED ENGINEERS ONLY. Husky freezers are designed for easy maintenance. One feature is that the compressor, condenser and condenser fan are mounted on an easilyaccessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two screws (which have now become accessible) on the top on either side of the kick plate see Fig 5 on page 29. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb screws on either side of the sliding tray see Fig. 4 on page 29. With caution slide out the sliding tray no more than 300mm. COMPRESSOR QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray see Easy Maintenance Access. CLEANING The condenser MUST be cleaned quarterly. Carefully remove the kick plate (see above for how to remove the kick plate) and use a soft brush to clean the condenser. The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on page 29). Clean the external and internal surfaces of the unit with a mild soap solution, then wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use mild soapy water to clean the gasket and seals. GETTING SERVICE ASSISTANCE The cooling system is a hermetically sealed circuit and does not require any maintenance other than regular cleaning (see Cleaning ). If the unit fails to work, first check the power supply. If you cannot locate the reason for the failure, please contact your supplier, stating the model and serial number of the cabinet. You may find this information on the rating plate, which is affixed inside the unit on the top right-hand interior wall. 30 International PRO upright manual 240317 EDITION 2 v2.indd 30 28/03/2017 08:34

Circuit Diagrams F5PRO Standard models, no canopy F10PRO Standard models, no canopy Wiring Diagram ELECTRONIC THERMOSTAT 31 International PRO upright manual 240317 EDITION 2 v2.indd 31 28/03/2017 08:34

Welcome to Husky, the home of smart refrigeration. We are a leading global refrigeration specialist with over 25 years experience in quality refrigeration for convenience and hospitality professionals, and we have a great range of chillers for the home too. You ll find Husky products all over the world, so whatever your requirements we re sure to have a good looking energy-efficient model that s perfect for you. www.husky-international.com www.husky.co.uk HELPLINE/TECHNICAL SUPPORT To contact your local technical support, refer to the rating plate on the inside wall or the back of your unit. 280317. Edition 2. International PRO upright manual 240317 EDITION 2 v2.indd 32 28/03/2017 08:34