Installation Manual Tracker 221

Similar documents
Temperature Controllers

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

F4 Process Controller Installation and Operation Guide

02/11/2015

I/A Series 716C 1/16 DIN Temperature Controller

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

02/11/2015

Table of Contents SECTION PAGE

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Carbon Monoxide Transmitter

PTE0705 Electric Fence Monitor

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Series Temperature Controller Instruction Sheet

General Specifications

Nov 08 PRODUCT SPECIFICATION SHEET

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

RS485 MODBUS Module 8AI

UDC 700 Universal Digital Controllers and Indicator Specifications

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CTT8 TEMPERATURE MONITOR DEVICE

CLEANROOM MONITOR CR3A Network - Installation Instructions

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

MO n : 12JMC rév A

N1540 Process Indicator

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

Series Digital Controller Instruction Sheet

Module Features are-configurable, no module jumpers to set

Pump-Down Controller MODEL 4052

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Pump-Up Controller MODEL 4062

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Analog Room Pressure Monitor RPC Series

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

eed quality electronic design USER s MANUAL

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

UDC100 Universal Digital Controller Specifications

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

/8 DIN Level Indicator

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

/8 DIN Universal Process Indicator

7EF/7HF/7EC/7ES Temperature Controllers

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

and Channel indicator and monitoring unit B Operating Instructions 2.00/

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

SHIMADEN DIGITAL INDICATORS

COMMANDER 150. User Guide Universal Process Indicator A1

SCAN200E USER S MANUAL

Operating Instructions tico Temperature Indicator

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

OVEN INDUSTRIES, INC.

FIRERAY 5000 range USER GUIDE

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

User Guide IM/C160_8. Wall-/Pipe-mounted Universal Process Indicator C160

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Danfoss gas detection units

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

21-light Remote Annunciator. Owner s Manual

Indicator N1500 UNIVERSAL PROCESS INDICATOR INSTRUCTIONS MANUAL V2.3 C SAFETY SUMMARY PRESENTATION TECHNICAL ASSISTANCE

Advanced Test Equipment Rentals ATEC (2832)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Model 96VTR ¼ DIN Process Controller

Universal display DA9602

99 Washington Street Melrose, MA Phone Toll Free Visit us at

ST Wiring diagram. Product description. Standard temperature controller. Order number

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Software Version 2.01 LEVEL MONITOR MODEL 220

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

ST Wiring diagram. Product description. Four-stage controller. Order number

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Oxygen / Carbon Dioxide Analyser / Transmitter. Model 1637

Oxygen (O2) Single-Point Gas Detection System

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Alarm Modules Section E

P2267 NETWORK INTERFACE

Analog Input Module IC670ALG630

EUROTHERM ONTROLS. Alarm Unit FULLY COMPLIANT. Product data

Transcription:

Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com

Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing the Tracker 220-series...8 Panel mounting the Tracker 220-series...10 Connecting the Signal Input...12 Connecting the Alarm Relays...13 Connecting the Analogue Output...13 Connecting the Serial Interface...14 Connecting the Transmitter/Transducer Power Supply...16 Powering the Tracker 220-series...17 User Functions...18 Configuring the Tracker 220-series...20 Configuring the Signal Input...22 Using the Scaling Facility...24 Configuring the Alarms...26 Configuring the Alarm Relays...30 Configuring the Analogue Output...32 Configuring the Serial Interface...34 Configuring the Status Inputs...36 Configuring the Function Keys...38 The Systems Menu...40 The Linearisation Facility (special programming)...42 Configuring the Transmitter/Transducer Power Supply...44 Error and Alarm Messages...45 Technical Specifications...46 Default Settings...50 TRACKER MANUAL ENGLISH 3

About this Installation Manual This Installation Manual describes how to install your Programmable Digital Display Unit Tracker 220 configure it for most common applications. If you require more detailed information, please order a copy of the Tracker 200 Series User Guide. The Programmable Digital Display Units Tracker 220 are marked with the international hazard symbol. It is important to read this Installation Manual before installing or commissioning your Tracker 220 as it contains important information relating to safety and EMC. Description Tracker 220-series The Tracker 220 series consists of a range of four different models, the Tracker 221, 222, 223 and 224. All four models are designed to interpret and display a wide range of process signals. This installation manual only describes the use with sensors from KSR Kuebler Niveau-Messtechnik AG. All models in the Tracker 220 series have a sensitivity to 1.0µV or 0.2µA per displayed value. The signal input is measured every 0.1 seconds and displayed every 0.5 seconds. You can view either the measured value, the maximum value, the minimum value or the average value. 4 TRACKER MANUAL ENGLISH

The facilities available on each of the four models in the Tracker 220 series are listed in the table. Facility Tracker 220 Model 221 222 223 224 Number of Display Digits 4 4 5 5 4 Configurable Alarms 2 Alarm Relays 2 Function Keys 2 Status Inputs Scaling and Linearisation Configurable Maths Functions Configurable Decimal Point Position 24V Transmitter Supply 10V Transducer Supply Variable 0-12V Transducer Supply Serial Communications Interface Analogue Output TRACKER MANUAL ENGLISH 5

Configuration All Tracker 220 models can be configured via the front panel buttons. In addition to this, the Tracker 223 and 224 can be configured by using the Tracker 220 Configuration Program running on a PC connected to the instrument. A Configuration Adapter Box can also be supplied which allows you to configure Tracker 221 and 222 units using the Tracker 220 Configuration Program. Full details on the Tracker 220 Configuration Program and the Configuration Adapter Box are given in the Tracker 200 Series User Guide which can be made available on request. Alarms All Tracker 220 models have four user configurable alarms. Each alarm can be configured to be high, low or deviation. A high alarm is triggered when the displayed value goes above the alarm setpoint. A low alarm is triggered when the displayed value goes below the alarm setpoint. When you configure a deviation alarm you must specify a deviation band formed by the high and low deviation points. As long as the displayed value remains within this band, the alarm will not be triggered. In addition to this, the Tracker 222 and 224 models each have two alarm relays. See page 26 and page 30 for details. Scaling and Linearisation For use with KSR Level Sensors the unit is pre-set for linear inputs. See page 22 for details. For special applications the scaling and linearisation can be carried out manually to display the correct measurement. Please see page 24 and page 42 for details. 6 TRACKER MANUAL ENGLISH

Analogue Output The Tracker 223 and Tracker 224 incorporate an analogue output which can be configured to transmit the measured value, the maximum, minimum or average value, or any value sent via the serial interface. For details, see page 32. Status Inputs and Function Keys All models in the Tracker 220 series have two function keys which can be configured to perform many of the most commonly used facilities, such as tare or alarm acknowledge. In addition to this, the Tracker 223 and 224 models have two status inputs which you can configure to perform all of the facilities available on the function keys, plus several additional facilities. For details, see page 36 and page 38. Serial Interface The Tracker 223 and 224 have a serial communications interface, allowing you to use it as a remote measurement and display device. For details, see page 34. For configuration purposes, the Tracker 223 and 224 can be connected via the communications interface to a PC running the Tracker 220 Configuration Program. Transducer/Transmitter Power Supply All models in the Tracker 220 series have a fixed 24V power supply intended for powering transmitters. In addition to this, the Tracker 221 and 222 have a fixed, regulated 10V power supply, and the Tracker 223 and Tracker 224 have a variable, user-programmable 0-12V power supply, intended for powering transducers. See page 16 for details. TRACKER MANUAL ENGLISH 7

Installing the Tracker 220-series During installation of all Tracker 220-models, you will need to carry out the following: Stick the engineering unit label onto the right hand side of the display panel. A sheet of labels is supplied with all Tracker 220 models covering most commonly used engineering units. If the unit you require is not on the sheet, a blank label is provided on which you can LETRASET the symbol you need. Insert the Tracker 220 into the instrument panel. See page 10. Connect the Tracker 220 to the input. See page 12. Connect the Tracker 220 to the power supply. See page 17. In addition, according to the model: Connect the analogue output (Tracker 223 and 224, see page 13) Connect the serial interface (Tracker 223 and 224 only, see page 14) Connect the transmitter/transducer power supply (see page 16) Connect the alarm relays (Tracker 222 and 224 only, see page 13) Please note: Ensure that the Tracker 220 is switched off before carrying out any installation or maintenance work. It is recommended that all connections to the terminals are made using bootlace ferrules to afford greater reliability and to prevent short circuits between adjacent terminals. Do not install the instrument close to switch gear, contactors or motor starters. Do not place signal and power supply wiring in the same loom. Use screened cables or wires for all signal/sensor leads with the screen earthed at one point only. 8 TRACKER MANUAL ENGLISH

The diagram below shows the rear panel of the Tracker 221. Transmitter/Transducer Power Supply +24V + GND 7 8 9 17 18 21 22 23 24 25 26 N L Power Input 90-265 V AC Iout Iin V V2 V1 COM Sensor Inputs The diagram below shows the rear panel of the Tracker 222, 223 and 224. Alarm Relay 1 Alarm Relay 2 Transmitter/ Transducer Power Supply Serial Interface Rx Tx Status Inputs C NO NC C NO NC +24V + GND + - + - 2 1 C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 N L + - Iout Iin V V2 V1 COM Power Input Analogue Output Sensor Inputs 90-265 V AC TRACKER MANUAL ENGLISH 9

Panel mounting the Tracker 220-series Ensure that there is sufficient space behind the instrument panel for the depth of the Tracker 220 unit. The diagram below is a side-view of the Tracker 220, showing its dimensions. 7 mm (0.3 ) 151 mm (6 ) 15 mm (0.6 ) 40 mm (1.6 ) 166 mm (6.6 ) Depth behind Panel The Tracker 220 is supplied with a mounting kit consisting of two mounting brackets, each with its own headless screw. To insert the Tracker 220 into the panel, follow the steps listed below: 1. Make a cut-out in the panel with dimensions as shown in the diagram below. The panel must have a thickness between 1.5mm and 9.5mm. 93 mm (3.66 ) 44,5 mm (1.75 ) 10 TRACKER MANUAL ENGLISH

2. To fit the optional rubber seal to prevent water penetrating behind the instrument panel, slip the seal onto the unit from the rear, pushing it forwards until it is sitting behind the front lip of the Tracker 220. 3. Insert the Tracker 220 into the instrument panel from the front, pushing it through as far as the front lip. The rubber seal sits between the front of the instrument panel and the front lip of the Tracker 220. 4. Working from behind the instrument panel, take the two mounting brackets, one for each side of the Tracker 220 casing, and ensure that the keyholes are pointing in the correct direction, as shown below. With the keyholes placed over the lugs on the Tracker 220 casing, pull the brackets backwards until they are locked into place. 5. Insert the headless screws supplied through each of the mounting brackets and tighten them until they bite into the instrument panel, securing the Tracker 220 unit in place. TRACKER MANUAL ENGLISH 11

Connecting the Signal Input The connections will vary depending on the type of input from the sensor. Common options are as follows: KSR Level Sensor (voltage input ± 10V) Digital display (current input ±20mA) Do not run signal leads next to power supply leads. The signal cable should be screened and the screen connected to earth at one point only. The diagrams below show the connections necessary for the most common input types. KSR Level Sensor (voltage input ±10V) Alarm Relay 1 Alarm Relay 2 Transmitter/ Transducer Power Supply Serial Interface Rx Tx Status Inputs C NO NC C NO NC +24V + GND + - + - 2 1 C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 N L + - Iout Iin V V2 V1 COM Power Input Analogue Output Sensor Inputs 90-265 V AC blue brown black KSR Level Sensor Digital Display (current input ±20mA) 21 22 23 24 25 26 Iout Iin V V2 V1 COM 12 TRACKER MANUAL ENGLISH

Connecting the Alarm Relays The Tracker 222 and Tracker 224 are both supplied with two alarm relays. Full details on how to configure the alarm relays are given on page 30. The alarm relay connectors are present on the Tracker 223 but are not operational. The diagram below shows the connections required. 1 2 3 4 5 6 C NO NC C NO NC Relay 1 Relay 2 Connecting the Analogue Output The analogue output facility is available on the Tracker 223 and 224. The analogue output port is present on the Tracker 222 but is not operational. Full details on how to configure the analogue output are given on page 32. The diagram below shows the connections required. TRACKER MANUAL ENGLISH 13

Connecting the Serial Interface The Tracker 223 and Tracker 224 have a communications interface which can be used for connection to a PC running the Tracker 220 Configuration Program, or for connection to a master device running a SCADA system. You can also use the Tracker 220 as a remote display device, displaying a value sent via the communications interface. Full details on how to configure the communications interface are given on page 34. The communications interface is compatible with 4-wire RS422 links, and 2 or 4-wire RS485 links. Connections to the communications interface should be made using screened twisted pairs. The screen should be connected to earth at one point only. For 4-wire interfaces both pairs should be individually screened and connected to earth at one point only. The positive terminals of the unit (10 and 12) should be connected to the positive terminals of the master device. Where the unit is operating as part of a multi-unit system, the master device transmitter should be capable of driving a load of 12kΩ for 2-wire half duplex operation. The diagrams opposite show the connections required. 14 TRACKER MANUAL ENGLISH

4-Wire Connection PC or PLC Tx Rx E + - + - Screened twisted pairs 10 11 12 13 14 15 16 + - + - Rx Tx 2-Wire Connection PC or PLC E + - Screened twisted pair 10 11 12 13 14 15 16 + - TRACKER MANUAL ENGLISH 15

Connecting the Transmitter/Transducer Power Supply All models of Tracker 220 are supplied with a 24 volt transmitter power supply. In addition to this, the Tracker 221 and Tracker 222 are supplied with a 10 volt transducer power supply. The Tracker 223 and Tracker 224 are both supplied with a variable 0-12 volt transducer power supply. The diagrams below show the connections required for each of the options. 24V-Transmitter Power Supply (all types) 7 8 9 +24 + GND 10V-Transducer Power Supply, fixed (Tracker 221 and 222) 7 8 9 +24 + GND 0-12V-Transducer Power Supply, variable(tracker 223 and 224) 7 8 9 +24 + GND 16 TRACKER MANUAL ENGLISH

Powering the Tracker 220-series The standard Tracker 220 operates at supply voltages of 90-265 Volt AC at 50/60Hz (type code -1). There is also a low voltage version which operates at 10-32 Volt AC or 12-28 Volt DC (type code -2). On both versions, consumption is approximately 10VA for the Tracker 223 and 224 and 7VA for the Tracker 221 and 222. Application of supply voltages higher than those for which the instrument is intended may affect the safety of the instrument and cause permanent damage. Check the label on the top of the unit for the correct supply voltage. The Tracker 220 has been designed for installation in an enclosure which provides adequate protection against electric shock. Access to power terminals should be restricted to authorised skilled personnel only. The diagram below shows the connections required to power the instrument. 17 18 BL BN N L (Standard) - + (Low voltage units) Power loss If the power supply to the Tracker 220 is broken, all configuration settings are saved, as are the maximum, minimum and average display values and alarm states for latching alarms. TRACKER MANUAL ENGLISH 17

User Functions All the Tracker 220-series user functions are illustrated opposite, along with the button presses needed to access them. These functions are described below. Display Functions Display the minimum value. Display the maximum value. Display the average value. Entering the Configurations Menu Entering the Configurations Menu, see page 20. Alarm Functions Use the functions illustrated opposite to view and change the alarm setpoints and to acknowledge latched alarms. All other alarm facilities are available from the four alarm menus, described on page 26. Function Keys When a function key is pressed, the facility assigned to it is immediately performed. A facility is assigned to a function key by using the two function key menus described on page 38. 18 TRACKER MANUAL ENGLISH

Display Setpoint Alarm 1 * Edit Setpoint Alarm 1 * Edit Setpoint Alarm 2 Display Setpoint Alarm 2 together Alarm bestätigen Function Key 1 Function Key 2 Measured Value Display press and hold Display Min.-value Display Max.-value Display average value Configurations Menu These functions can be barred. See page 32 for details. Use the and keys to edit the flashing digit. Use the key to select another digit. TRACKER MANUAL ENGLISH 19

Configuring the Tracker 220-series The Configurations Menu allows you access to several sub-menus, as shown in the diagram opposite. For details on how to access the Configuration Menu, refer to the flow diagram on page 19. Depending on your model of Tracker 220, not all of these sub-menus will be available. Using these sub-menus you can change all of the default parameters listed on page 50 to 54. Pressing the - or -keys changes the flashing digit, the -key (far left of the button panel) moves the flashing digit from one to the next position. Pressing the -key (far right of the button panel) resets all digits to zero. Pressing -key acknowledges the set value. A negative value can be set by changing the segment on the far left of the display to either - or -1. You do this by pressing the or buttons repeatedly to scroll past all the digits. When the password facility is switched on, the prompt PASS is displayed if you try to enter the Configurations Menu. To enter your password, use the or buttons to edit the flashing digit and the button (on the far left of the button panel) to move from one digit to the next. To exit any menu and return to normal display operation, simply press the button repeatedly. 20 TRACKER MANUAL ENGLISH

Menu Input Menu Scale Menu Alarm 1 Menu Alarm 2 Enter Password Menu Alarm 3 Menu Alarm 4 Menu Relays Menu Power Supply Menu Analogue Ouptput Measured Value Display See Page 19 Menu Serial Interface Menu Status Input 1 Menu Status Input 2 You are only requested to enter a password if your unit is configured for password access. Menu Function Key 1 Menu Function Key 2 Systems Menu Menu User Linearisation TRACKER MANUAL ENGLISH 21

Configuring the Signal Input This menu allows you to define the signal input parameters. Preferred options are bold typed. Sensor type. See explanation of codes on page 49. Range of the sensor. For ranges which are not pre-defined, select Lin (for linear relationships) or ulin (for non-linear relationships, special programming). The unit for the displayed value. Select EnG for a nontemperature unit (standard). Position of the decimal point on the display, from 0 to 4 for a 5- digit display (nnnnn to n.nnnn) or 0 to 3 for a 4-digit display (nnnn to n.nnn). Select Auto for maximum resolution. The type of reference junction used, either internal automatic compensation (Auto) or external temperature reference (EXt). The temperature in C at the external reference point. The trim value in C for internal compensation, e.g. if error = +2 C, trim value = - 2. Wire break control (not available with KSR level sensors) Behaviour on wire break (not available with KSR level sensors) UP Analogue output to maximum and high alarms triggered. DOWN Analogue output to minimum and low alarms triggered. The maths function to be performed. Select from 5/2 root, 3/2 root, square root or none. Filter time constant to filter noisy signals. 22 TRACKER MANUAL ENGLISH

T/C Volt MV Ser Pt/4 Pt/3 Pt/2 MA n/mo u n S E r b t J k ulin Lin P130 n100 d100 P100 PALP PLt2 C d FEC G EnG AbS F C Auto 4 3 2 1 0 Auto EXt From Configurations Menu See page 21 External CJC-Temperature in C Only displayed if a themocouple input (T/C) is selected. Only diplayed if EXT CJC is selected. Only displayed if AUTO CJC is selected. on CJC trim value up off down none 5/2r 3/2r Sqrt Value TRACKER MANUAL ENGLISH 23

Using the Scaling Facility If the signal input from the sensor has a linear relationship to the displayed value, and this relationship is not 1:1, the scaling facility can be used to ensure that the measured value is correctly displayed on the Tracker 220. Before using the scaling facility, the "range" parameter on the Input Menu must be set to linear (Lin). You can also use the scaling facility to calibrate the Tracker 220 to a sensor output with a consistent linear offset error. The following data have to be specified: Signal input and required display value at low end of measuring range. Signal input and required display value at high end of measuring range. The input values can be defined by entering via the front button panel or by measuring the signal input directly. On using this automatic read-in, the signal will be averaged over approx. 15 seconds. Required display value (low end measuring range) Signal inputs value (low end measuring range) Select between manual input and automatic read-in Read-in from signal source (sensor) Required display value (high end measuring range) Signal inputs value (high end measuring range) 24 TRACKER MANUAL ENGLISH

Low display value Low input value manual Low input value automatic From Configurations Menu See page 21 High display value High input value manual High input value automatic TRACKER MANUAL ENGLISH 25

Configuring the Alarms The Tracker 220 has four separate software alarms, each of which is configured via a separate alarm menu. These menus allow you to define various parameters described below. Alarm types: High, Low or deviation (Dev). For details, see page 6. Alarm 1-setpoint (switch point) Alarm 2-setpoint (switch point) Alarm 3-setpoint (switch point) Alarm 4-setpoint (switch point) High deviation point, i.e. the difference between the alarm setpoint and the high deviation point. Low deviation point, i.e. the difference between the alarm setpoint and the low deviation point. Alarm latch option Either latched (ON) or non-latched (OFF). A latched alarm must be acknowledged before it will clear. See page 18 for instructions on acknowledging alarms. Alarm relay option This option specifies whether an alarm being triggered will change the state of relays 1 or 2, both or neither. Trigger delay option This allows you to specify the delay between the alarm conditions being met and the alarm being triggered. Alarm clear delay option This allows you to specify the delay between the alarm conditions being absent and the alarm being cleared. 26 TRACKER MANUAL ENGLISH

The on-hysteresis value, i.e. the difference between the setpoint and the on-hysteresis point. You can specify on- and off-hysteresis points either side of the alarm setpoint. The alarm is triggered when the displayed value goes above the on hysteresis point and is cleared when it returns below the off hysteresis point. The off-hysteresis value, i.e. the difference between the alarm setpoint and the off-hysteresis point. The alarm edit option. This parameter allows you to specify whether or not alarm setpoints 1 and 2 can be edited using the operator functions, as described on page 18. The alarm message display option. This parameter allows you to select whether or not alarm messages are displayed. The link alarm option. This allows you to link setpoint 3 to setpoint 1, and setpoint 4 to setpoint 2. For example, if setpoint 3 is linked to setpoint 1, and setpoint 1 is changed, setpoint 3 will automatically be changed to match it. TRACKER MANUAL ENGLISH 27

HiGH dev LoW Setpoint 1 value Deviation high value Deviation low value on off none 1.2 2 1 From Configurations Menu See page 21 On delay time (secs) Off delay time (secs) On hysteresis value Only displayed if deviation alarm is selected. Only displayed if relays are fitted. Off hysteresis value on off on off 28 TRACKER MANUAL ENGLISH

HiGH dev LoW Setpoint 2 value Deviation high value Deviation low value on off none 1.2 2 1 From Configurations Menu See page 21 On delay time (secs) Off delay time (secs) On hysteresis value Only displayed if deviation alarm is selected. Only diplayed if relays are fitted. Off hysteresis value on off on off Menus are valid accordingly for alarm 3 and alarm 4. TRACKER MANUAL ENGLISH 29

Configuring the Alarm Relays The Tracker 222 and Tracker 224 are fitted with two alarm relays, known as Relay 1 and Relay 2. You can configure these Tracker 220 models to change the state of the alarm relays either when a single software alarm is triggered or when a specific combination of alarms is triggered. To configure the Tracker 220 to change the state of an alarm relay when a single alarm is triggered, use the output facility available from each of the individual Alarm Menus. To configure the Tracker 220 to change the state of an alarm relay when a specific combination of alarms is triggered, use the Relay Menu illustrated opposite. Using the Relay Menu, you can also specify the alarm state of each of the relays, i.e. whether the relay is energised or de-energised when an alarm is triggered. Alarm State Relay 1: TruE energised FLSE de-energised Alarm State Relay 2: TruE energised FLSE de-energised Specify the combination of alarms which is to change the state of Relay 1. For example: 1 2 _ 4 means that the state of Relay 1 is only changed when alarms 1, 2 and 4 are all triggered. Specify the combination of alarms which is to change the state of Relay 2. 30 TRACKER MANUAL ENGLISH

true FLSE true FLSE From Configurations Menu See page 21 TRACKER MANUAL ENGLISH 31

Configuring the Analogue Output The Tracker 223 and 224 are fitted with an analogue output. You can configure the analogue output signal to suit your requirements as follows: and Select the signal type to transmit: 0-10V, 0-20mA or 4-20mA. Select the signal source: inpt measured value HIGH Maximum value LoW Minimum value AV Average value Ser value sent via Serial Interface Select the scaling of the signal output. You can scale the analogue output to retransmit a signal which is proportional to any part of the displayed range. You do this by specifying the low point and the high point of the range which you want to retransmit. Select the signal damping constant. You can damp the signal which is being retransmitted via the analogue output. This facility can be used to limit the rate of change of fast-moving or noisy signals. The higher the value of the damping constant, the slower the rate of change of the signal. The damping constant can be set in the range 1 to 999. 32 TRACKER MANUAL ENGLISH

0-10 0-20 4-20 inpt HiGH LoW AV SEr From Configurations Menu See page 21 Low value High value Value in secs TRACKER MANUAL ENGLISH 33

Configuring the Serial Interface To match the communications protocol from the Tracker 220 with that of the device with which it is communicating, the serial interface can be configured as follows (Tracker 223 and 224 only): Select the communications address for the Tracker 220, in the range 1-247. Select the baud rate: 1200, 2400, 4800 or 9600. Select write protect (ON) or write enable (off). Select the parity, either odd, even or none. If Modbus binary protocol is selected, there is no parity bit and this parameter is ignored. Set the number of stop bits, either 1 or 2. If you are using Modbus ASCII or Modbus binary protocol, negative values must be represented by positive values. All values must be scaled to one of the following ranges: 0-65335 (65.5K), 0-32767 (32.7K), 0-32000 (32K). Select the Modbus ASCII or binary low scale point. Select the Modbus ASCII or binary high scale point. Select ON for Modbus binary protocol, or OFF for Modbus ASCII protocol and/or Data Track Process Instruments ASCII protocol. Set the Modbus binary protocol pre-transmission delay, either 0, 100, 200 or 300 milliseconds. 34 TRACKER MANUAL ENGLISH

Address (from 1 to 247) 1200 2400 4800 9600 on off odd EVEn none From Configurations Menu See page 21 1bit 2bit 32k 32.7k 65.5k Low value High value on off 0 100 200 300 TRACKER MANUAL ENGLISH 35

Configuring the Status Inputs The Tracker 223 and Tracker 224 are each fitted with two status inputs. You can assign any one or more of the following functions to a status input so that the function is performed when the status input is switched on and continues until the status input is switched off. To assign a function, select ON as illustrated opposite. The tare facility. The alarm acknowledge facility. The alarm disable facility. Any one of the following functions: LtSt AV HiGH LoW Lamp test Display average value Display maximum value Display minimum value HoLd Display hold The reset facility. This resets the maximum, minimum and average values. Inhibit front panel operation. The analogue output hold facility. This freezes the analogue output signal at a constant level. The autozero facility. This resets the display to zero, permanently removing any offset error. The Status Input Message facility, causing a message to be intermittently displayed when a status input is switched on. 36 TRACKER MANUAL ENGLISH

on off on off on off or none LtSt AV HiGH LoW HoLd From Configurations Menu See page 21 on off on off on off on off on off TRACKER MANUAL ENGLISH 37

Configuring the Function Keys The Tracker 220 front panel has two function keys: Function key 1 Function key 2 You can assign any one or more of the functions listed below to each of the function keys. To assign a function to a function key, select ON as shown in the diagram opposite. The tare facility. When tare is assigned to a function key, pressing the key once will switch the facility on, pressing it again will switch it off. The reset facility. This resets the maximum, minimum and average values. When reset is assigned to a function key, the function will be performed as soon as you press the key. The autozero facility. This resets the display to zero, permanently removing any offset error. When autozero is assigned to a function key, pressing the key once will cause ZERO to be flashed for 5 seconds. If you press the key again within this period, autozero is performed. Any one of the following functions: LtSt Lamp test AV Display average value HiGH Display maximum value LoW Display minimum value HoLd Display hold If one of these is assigned to a function key, the function will operate for as long as the key is held down.. 38 TRACKER MANUAL ENGLISH

on off on off or From Configurations Menu See page 21 on off none LtST AV HiGH LoW HoLd TRACKER MANUAL ENGLISH 39

The Systems Menu The following functions are available from this menu: The password facility. This allows you to switch on password protection so that the Configurations Menu cannot be accessed without entering a password. Switch on password protection by creating any password in the range 1 to 99999. If the password is set to 0, the facility is switched off. The leading zero suppression facility. This allows you to suppress leading zeros on the display (ON) or display leading zeros (off). The averaging time facility, allowing you to specify the period over which the average value is calculated in seconds. This facility allows you to set the mains frequency to 50 Hz or 60 Hz. The system reset facility. This allows you to reset the Tracker 220 to its default settings. Select ON to reset the unit. The time-out facility. This allows you to specify the time-out period in seconds. This is the time which can pass without a button being pressed in a configuration menu before you are returned to normal display operation. 40 TRACKER MANUAL ENGLISH

Value on off Value 50HZ 60HZ From Configurations Menu See page 21 on off Value TRACKER MANUAL ENGLISH 41

The Linearisation Facility (Special programming) If the signal from the connected sensor is not linear to the measured value (e.g. with lying cylindrical vessels), this linearisation facility can be used to match an input signal with a displayed value. If the relationship between signal input and displayed value is linear, the scaling facility should be used rather than the user linearisation facility. The user linearisation facility allows you to define up to 24 linearisation points. For each point you must enter both an input value and the corresponding display value. You can define the input value points either by entering them manually via the front panel, or by using the automatic read-in from the signal source. Before you start with programming the linearisation points, please go back to the menu "INPUT" and its sub-menu "MEASURING RANGE" to change the input type of the Sensor to ulin. Enter the number of linearisation points you want to define, or increase the current number of linearisation points if you want to add a new one. Define the display value for a linearisation point. Define the input values for a linearisation point. VAL Enter value manually read Read-in signal automatically 42 TRACKER MANUAL ENGLISH

Number of linearisation points Display value Input value, manual From Configurations Menu See page 21 Input value, read-in Display value Input value, manual * Where n is the number of the linearisation point. Input value, read-in TRACKER MANUAL ENGLISH 43

Configuring the Transmitter/Transducer Power Supply All Tracker 220 models are fitted with a 24 Volt power supply intended to power a transmitter. In addition to this, the Tracker 221 and Tracker 222 are fitted with a 10 Volt power supply, intended for powering a transducer. The Tracker 223 and 224 are fitted with a variable 0-12 volt power supply, also intended for powering a transducer. This is user configurable via the TPSU Menu illustrated below. You can select the voltage in the range 0.00 to 12.00 Volts, with a resolution of 0.01 Volts. From Configurations Menu See page 21 Value 44 TRACKER MANUAL ENGLISH

Error and Alarm messages Error messages The input circuit has broken. The sensor break detection option has been set to DOWN. See page 22. The input circuit has broken. The sensor break detection option has been set to UP. See page 22. The measured value is too large positively to be displayed on the Tracker 220, or is above the specified range for the connected sensor. The measured value is too large negatively to be displayed on the Tracker 220, or is below the specified range for the connected sensor. Alarm messages Low type alarm n has been triggered. High type alarm n has been triggered. Deviation type alarm n has been triggered at the deviation low point. Deviation type alarm n has been triggered at the deviation high point. (where n is the alarm number, i.e. 1, 2, 3, or 4). TRACKER MANUAL ENGLISH 45

Technical Specifications Power supply Standard units Low voltage units 90 to 265VAC, 7 to 10VA approx. 40mA at 250VAC for Tracker 224 10 to 32VAC, 7 to 10VA 12 to 28VDC Display Type 0.56", high brightness, 7 segment-led, red or green Range -19999 to +99999 (Tracker 223 and 224) -1999 to + 9999 (Tracker 221 and 222) A/D-Converter Type Conversion Rate Converter Resolution Common Mode Rejection Series Mode Rejection Drift Dual slope integrating converter 10Hz (10 conversions/s) 16 Bits + sign (1µV) >150dB >70 db (50 or 60Hz) 50 ppm/ C 46 TRACKER MANUAL ENGLISH

Current Input Range Accuracy Resolution Input Impedance Maximum Burden ±20mA 0.05% of measured value ±4µA 0.5µA 5 Ohm typical ±100mV typical Voltage Inputs Range ±100mV or ±10V Accuracy 0.05% of measured value, ±20µV Resolution 100mV-range: 1.0µV 10V-range: 152µV Input Impedance 100mV-input > 10 MOhm 10V-input > 1 MOhm Sensor Break On or off, up or downscale as standard. Alarms/Relays Alarms Relays Contact Rating 4 programmable software-alarms. Low, high or deviation 2 SPDT (Tracker 222 and 224 only) 1A at 250V TRACKER MANUAL ENGLISH 47

Analogue Output Ranges 0-10V, 0-20mA or 4-20mA Accuracy 0.2% of span Temperature Drift 100ppm / C Update Rate 30Hz Output Ripple <10mV or <50µA Response 63% within 32ms 99% within 100ms Damping programmable Resolution 0.05% of FS, 5mV or 0.01mA Maximum output 18V at 25mA Transducer/Transmitter Power Supply Outputs Resolution 0.01V Accuracy Temperature Drift <100ppm / C Output Ripple <5mV Update Rate 30Hz Output current max. 35mA 24 V transmitter power supply, unregulated 10 V fixed transducer supply (Tracker 221 and 222 only) 0-12 V transducer supply, programmable (Tracker 223 and 224 only) ±0.05V (programmable supply) ±0.2V (fixed supply) 48 TRACKER MANUAL ENGLISH

Input Type Codes Code Input Type T/C Thermocouple Volt Volt, max. ±10V MV Millivolt, max. ±100mV SER Value sent via the serial interface PT/4 RTD/resistance sensor (4 wire) PT/3 RTD/resistance sensor (3 wire) PT/2 RTD/resistance sensor (2 wire) MA Milliampère, max. ±20mA TRACKER MANUAL ENGLISH 49

Default Settings These defaults do not apply when the unit was delivered with a special programming by factory. Input Parameters Type mv Range Linear (Lin) Unit Engineering (Eng) Decimal point position 1 decimal Sensor break detection On Sensor break detection action Up Maths functions None Input damping filter 0 Scaling Parameters Display value at low measuring range 0.0 Inputs value at low measuring range 0.0 Display value at high measuring range 100.0 Inputs value at high measuring range 100.0 User Linearisation Parameters One linearisation point, set to zero. 50 TRACKER MANUAL ENGLISH

Parameters Alarm 1 Alarm type High Setpoint (switch point) 99999 (or 9999) Deviation high 0 Deviation low 0 Latch Off Relay None Alarm trigger delay 0 Alarm clear delay 0 On-hysteresis 0 Off-hysteresis 0 Edit setpoint On Display messages On Parameter Alarm 2 Alarm type Low Setpoint (switch point) -19999 (or -1999) Deviation high 0 Deviation low 0 Latch Off Relay None Alarm trigger delay 0 Alarm clear delay 0 On-hysteresis 0 Off-hysteresis 0 Edit setpoint On Display messages On TRACKER MANUAL ENGLISH 51

Parameter Alarm 3 Alarm type High Setpoint (switch point) 99999 (or 9999) Deviation high 0 Deviation low 0 Latch Off Relay None Alarm trigger delay 0 Alarm clear delay 0 On-hysteresis 0 Off-hysteresis 0 Link alarms Off Display messages On Parameter Alarm 4 Alarm type Low Setpoint (switch point) -19999 (or -1999) Deviation high 0 Deviation low 0 Latch Off Relay None Alarm trigger delay 0 Alarm clear delay 0 On-hysteresis 0 Off-hysteresis 0 Link alarms Off Display messages On 52 TRACKER MANUAL ENGLISH

Alarm Relay Parameters Relay 1 alarm state Relay 2 alarm state Relay 1 alarm group Relay 2 alarm group Relay energised Relay energised No alarms in group No alarms in group Transducer/Transmitter Power Supply Parameters Voltage setting 0 V Analogue Output Parameters Type 4-20 ma Source Measured value (inpt) Zero value 0 Span value 100 Signal damping 0 Serial Interface Parameter Communications address 1 Baud rate 9600 Write protection Off Parity Even Stop bits 1 bit Modbus span 32000 Modbus span low 0 Modbus span high 100 Modbus binary protocol Off Modbus binary protocol delay 0 TRACKER MANUAL ENGLISH 53

Status Inputs Parameters Tare Alarm acknowledge Alarm disable Display options Reset max., min. and average values Inhibit front panel operation Analogue output hold Autozero Display messages Off Off Off None Off Off Off Off On Parameter Function Keys 1 and 2 Tare Reset max., min and average values Autozero Display options Off Off Off None System Configuration Parameters Password 0 Suppress leading zeros On Averaging time 1 Mains frequency 50Hz System reset to default values Off Time-out period 60 seconds 54 TRACKER MANUAL ENGLISH

TRACKER MANUAL ENGLISH 55