HEAT PUMP Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it.

Similar documents
HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

MADE IN ITALY BY OLIMPIA SPLENDID

SHERPA. Air-water split heat pump. COP > 4 DHW 60 C

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

contents page say goodbye to outdoor units 2-3 unico inverter range 4-5 unico on off range 6-7 unico easy range 8-9

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

INVERTER 9-12 DC INVERTER 9 SF

UNICO Inverter Without external unit

The air conditioner without outdoor unit

Innovative air conditioning

EXPORT International Professional Distributor s meeting

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

ENG CATALOGUE Italian Company Since 1956

Climate control without outdoor unit

Climate control without outdoor unit

OLIMPIA SPLENDID, HOME OF COMFORT

Bringing a year round comfort solutions to extreme climates

Refrigerated Air Dryers

Technology DC Inverter = performance, comfort and saving R 410 A. >Several possible combinations : 3 outdoor units and 15 indoor units

Refrigerated Air Dryers

Refrigerated Air Dryers

High temperature hydrobox for VRV

General Air Conditioning Catalogue Collection

VRV IV heat recovery Best efficiency and comfort solution

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Refrigerated Air Dryer

Refrigerated Air Dryer

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Product catalogue 2012/13. Electromechanical controllers

NEXT DL NEXT DL. rcgroupairconditioning

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

» WITH REGASORP ROTARY HEAT EXCHANGER

COMMISSION REGULATION (EU)

EHPA Testing Regulation

IDU22C, 22C1, 37C, 37C1, 55C, 75C

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

Application guide ECOLEAN - EAC/EAR. Providing indoor climate comfort

unico pf unico pf rcgroupairconditioning

Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners

2009 Panasonic Marketing Europe GmbH / All rights reserved

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Air Conditioners Heating & Cooling

Cozy Hi Wall Inverter Air Conditioner

Air Conditioning. Technical Data EEDEN RXS-F8

VRV IV S-series heat pump

Hi - Wall Split Systems 12K - 18K - 24K

Saving the world and reducing energy costs with advanced CO 2 systems

HEAT PUMPS LINE AS AIR TO WATER

Be sustainable while protecting your business

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Water cooled VRV IV W-series

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

6ITALIAN COMPANY GENERAL CATALOGUE 2016 OLIMPIA SPLENDID. olimpiasplendid.com SINCE 1956

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

High Performance Air to Water Heat Pump

LZT High efficiency air to water heat pumps with E.V.I. compressors

MONO & MULTI SPLIT AIR CONDITIONERS

Air Conditioners Heating & Cooling

High Performance Air to Water Heat Pump

FH - GH Dehumidifiers for radiant cooling systems

Hansol Hi Wall Inverter Heat Pump

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

PRODUCT LINE-UP Residential & Light Commercial air conditioners

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

High Performance Air to Water Heat Pump

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Cooling Only & Heat Pump

Air Conditioners Heating & Cooling

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Air Cooler Industry OK-ELC 0-7

Air Conditioning Technical Data AZAS-MY1

where innovation meets creativity

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

6ITALIAN COMPANY SINCE 1956 GENERAL CATALOGUE 2016

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

GENERAL CATALOGUE July I talian technology and quality. Heat Pumps. Indirect Cylinders Electric Water Heaters.

NIBE SPLIT ACVM 270 Air/water heat pump

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

recooler HP EQKR HEAT PUMP

CONTROLLED MECHANICAL VENTILATION

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

WATER HEATERS AND HOT WATER STORAGE TANKS

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

DRYTEC REFRIGERANT DRYERS

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Transcription:

UNIO inverter The first air-conditioner without outdoor unit with inverter technology. UNIO INVERTER 9 SF od. 01068 UNIO INVERTER 9 HP od. 01060 UNIO INVERTER 12 SF od. 01067 UNIO INVERTER 12 HP od. 01052 Two capacity versions: 2.3 kw 2.7 kw vailable in versions: SF (ooling only) - HP (Heat Pump) Double class Refrigerant gas R410* Large flap for homogeneous air diffusion in the room Design by King e Miranda Economy mode: allows energy saving by automatically optimizing the machine s performance INVERTER SYSTEM Thanks to inverter technology, Unico saves up to 30% of energy as compared with motors with traditional technology. 100% 80% Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it. electrostatic filter(which eliminates small 70% NON INVERTER INVERTER D INVERTER SVINGS 30% UNIO INVERTER Weight kg mm 902 230 506 39 122

Indoor mbient Outdoor mbient UNIO INVERTER 9 SF UNIO INVERTER 12 SF UNIO INVERTER 9 HP UNIO INVERTER 12 HP Product code 01068 01067 01060 01052 Nominal cooling capacity (1) P rated kw 2,3 2,7 2,3 2,7 ooling power (min/max) (1) kw 1,4 / 2,7 1,8 / 3,1 1,4 / 2,7 1,8 / 3,1 Nominal heating capacity (1) P rated kw - - 2,4 2,7 Heating power (min/max) (1) kw - - 1,4 / 2,7 1,8 / 3,0 Nominal power consumption for cooling (1) PEER kw 0,9 1,0 0,9 1,0 Power consumption for cooling (min/max) (1) kw 0,46 / 1,30 0,58 / 1,40 0,46 / 1,30 0,58 / 1,40 Nominal absorption for cooling (1) 3,9 4,6 3,9 4,6 bsorption for cooling (min/max) (1) 2,1 / 5,8 2,7 / 6,4 2,1 / 5,8 2,7 / 6,4 Nominal power consumption for heating (1) POP kw - - 0,8 0,8 Power consumption for heating (min/max) (1) kw - - 0,42 / 1,20 0,53 / 1,30 Nominal absorption for heating (1) - - 3,4 3,8 bsorption for heating (min/max) (1) - - 1,9 / 5,3 2,4 / 5,9 Nominal energy efficiency index (1) EERd 2,7 2,7 2,7 2,7 Nominal efficiency coefficient (1) OPd - - 3,2 3,2 Energy efficiency class in cooling (1) Energy efficiency class in heating (1) - - Energy consumption in thermostat off mode PTO 12,0 12,0 12,0 12,0 Energy consumption in standby mode (EN 62301) PS 0,5 0,5 0,5 0,5 Energy consumption for double pipe appliances (1) cooling QDD kwh/h 0,9 1,0 0,9 1,0 Energy consumption for double pipe appliances (1) heating QDD kwh/h - - 0,8 0,8 Supply voltage V-F-Hz 230-1-50 230-1-50 230-1-50 230-1-50 Supply voltage minimum/maximum V 198 / 264 198 / 264 198 / 264 198 / 264 Maximum power consumption in cooling mode (1) W 1300 1400 1300 1400 Maximum absorption in cooling mode (1) 5,8 6,4 5,8 6,4 Maximum power consumption in heating mode (1) W - - 1200 1300 Maximum absorption in heating mode (1) - - 5,3 5,8 Maximum power consumption with electric resistance heating W - - - - Maximum absorption with electric resistance heating - - - - Dehumidification capacity l/h 1,0 1,1 1,0 1,1 ir flow rate in cooling environment (max/med/min) m³/h 490 / 430 / 360 490 / 430 / 360 490 / 430 / 360 490 / 430 / 360 ir flow rate in heating environment (max/med/min) m³/h - - 490 / 430 / 360 490 / 430 / 360 ir flow rate with electric resistance heating environment m³/h - - - - External air flow rate in cooling (max/min) m³/h 520/350 520/350 520/350 500/340 External air flow rate in heating (max/min) m³/h - - 520 / 350 500 / 340 Internal ventilation speed 3 3 3 3 External ventilation speed 6 6 6 6 Diameter wall holes mm 202* 202* 202* 202* Electric resistance heating - - - - Maximum range remote control (distance / angle) m / 8 / ±80 8 / ±80 8 / ±80 8 / ±80 Dimensions (Larg. x lt. x Prof.) (without packaging) mm 902 x 506 x 229 902 x 506 x 229 902 x 506 x 229 902 x 506 x 229 Dimensions (Larg. x lt. x Prof.) (with packaging) mm 980 x 610 x 350 980 x 610 x 350 980 x 610 x 350 980 x 610 x 350 Weight (without packaging) Kg 39 39 39 40 Weight (with packaging) Kg 43 43 43 43 Internal sound pressure (Min Max) (2) d() 33-42 33-43 33-42 33-43 Internal sound power level (EN 12102) LW d() 57 58 57 58 Degree of protection provided by covers IP 20 IP 20 IP 20 IP 20 Refrigerant gas* Type R410 R410 R410 R410 Global warming potential GWP kgo2 eq. 2088 2088 2088 2088 Refrigerant gas charge kg 0,57 0,57 0,57 0,58 Maximum operating pressure MPa 3,6 3,6 3,6 3,6 Power cable (N pole x section mm 2 ) 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5 LIMITS OF OPERTING ONDITIONS Maximum temperature in cooling D 35 - W 24 Minimum temperature in cooling D 18 Maximum temperature in heating D 27 - Maximum temperature in cooling D 43 - W 32 Minimum temperature in cooling D -10 Maximum temperature in heating D 24 - W 18 D -15 (1) TEST ONDITIONS: data refers to regulation EN14511 (2): Data test declaration in semianechoic room at a distance of 2m, minimum sound pressure with ventilation only. - y maintaining the same center to center distance of inlet and outlet holes and the possibility of installation with 162 mm diameter holes, models in the Unico Smart, Unico Inverter and Unico ct range may easily substitute previously installed Unico Star and Unico Sky models. * hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088 S SiOS SYSTEM TERMINL UNITS UNIO FIXED IR ONDITIONER PORTLE IR ONDITIONER IR OOLER VM DEHUMIDIFIERS HUMIDIFIERS FN HETERS ERMI FN HETERS GS STOVES PERSONL OMFORT 123 PELLET STOVES

UNIO inverter 13 + hp UNIO INVERTER 13 + HP od. 01716 apacity: 2.8 kw vailable in versions: HP (Heat Pump) lass Refrigerant gas R410* High efficency E inverter fan Large flap for homogeneous air diffusion in the room Design by King e Miranda Economy mode: allows energy saving by automatically optimizing the machine s performance DUL INVERTER MODE (D.I.M.) The DIM technological heart is located in an innovative control algorithm to optimize the efficiency when the unit works at 70% of its ambient thermal demand The algorithm allows to satisfy the real thermal demand on the 70% of the total working hours with a reduced consumption of 25% of our traditional UNIO INVERTER.** THERML LOD (kw) ooling Nominal capacity hours 14.00 ooling consumption 0,6 Kw minus 25% compare to traditional OS Inverter electrostatic filter(which eliminates small Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it. hours 10.00 DY TIME hours 18.00 UNIO INVERTER 13 + HP Weight kg mm 902 230 506 39 ** Internal laboratory tests on traditional Olimpia Splendid range 124

Indoor mbient Outdoor mbient UNIO INVERTER 13 + HP Product code 01716 Nominal cooling capacity (1) P rated kw 2,8 ooling power (min/max) (1) kw 1,8 / 3,1 Nominal heating capacity (1) P rated kw 2,7 Heating power (min/max) (1) kw 1,8 / 3,0 Nominal power consumption for cooling (1) PEER kw 0,6 Power consumption for cooling (min/max) (1) kw 0,58 / 1,40 Nominal absorption for cooling (1) 2,8 bsorption for cooling (min/max) (1) 2,4 / 6,1 Nominal power consumption for heating (1) POP kw 0,8 Power consumption for heating (min/max) (1) kw 0,53 / 1,30 Nominal absorption for heating (1) 3,8 bsorption for heating (min/max) (1) 2,4 / 5,9 Nominal energy efficiency index (1) EERd 3,1 Nominal efficiency coefficient (1) OPd 3,2 Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Nominal Design apacity Prated kw 2,0 Energy consumption in thermostat off mode PTO 12 Energy consumption in standby mode (EN 62301) PS 0,5 Energy consumption for double pipe appliances (1) cooling QDD kwh/h 0,9 Energy consumption for double pipe appliances (1) heating QDD kwh/h 0,8 Supply voltage V-F-Hz 230-1-50 Supply voltage minimum/maximum V 198 / 264 Maximum power consumption in cooling mode (1) W 1400 Maximum absorption in cooling mode (1) 6,4 Maximum power consumption in heating mode (1) W 1300 Maximum absorption in heating mode (1) 5,8 Maximum power consumption with electric resistance heating W - Maximum absorption with electric resistance heating - Dehumidification capacity l/h 1,1 ir flow rate in cooling environment (max/med/min) m³/h 490 / 430 / 360 ir flow rate in heating environment (max/med/min) m³/h 490 / 430 / 360 ir flow rate with electric resistance heating environment m³/h - External air flow rate in cooling (max/min) m³/h 500/340 External air flow rate in heating (max/min) m³/h 500/340 Internal ventilation speed 3 External ventilation speed 1 Diameter wall holes mm 202 Electric resistance heating - Maximum range remote control (distance / angle) m / 8 / ±80 Dimensions (Larg. x lt. x Prof.) (without packaging) mm 902 x 506 x 229 Dimensions (Larg. x lt. x Prof.) (with packaging) mm 980 x 610 x 350 Weight (without packaging) Kg 39 Weight (with packaging) Kg 42 Internal sound pressure (Min Max) (2) d() 33-43 Internal sound power level (EN 12102) LW d() 58 Degree of protection provided by covers IP 20 Refrigerant gas* Type R410 Global warming potential GWP kgo2 eq. 2088 Refrigerant gas charge kg 0,50 Maximum operating pressure MPa 3,6 Power cable (N pole x section mm 2 ) 3 x 1,5 LIMITS OF OPERTING ONDITIONS Maximum temperature in cooling D 35 - W 24 Minimum temperature in cooling D 18 Maximum temperature in heating D 27 - Maximum temperature in cooling D 43 - W 32 Minimum temperature in cooling D -10 Maximum temperature in heating D 24 - W 18 D -15 (1) TEST ONDITIONS: data refers to regulation EN14511 (2): Data test declaration in semianechoic room at a distance of 2m, minimum sound pressure with ventilation only. - y maintaining the same center to center distance of inlet and outlet holes and the possibility of installation with 162 mm diameter holes, models in the Unico Smart, Unico Inverter and Unico ct range may easily substitute previously installed Unico Star and Unico Sky models. * hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088 S SiOS SYSTEM TERMINL UNITS UNIO FIXED IR ONDITIONER PORTLE IR ONDITIONER IR OOLER VM DEHUMIDIFIERS HUMIDIFIERS FN HETERS ERMI FN HETERS GS STOVES PERSONL OMFORT 125 PELLET STOVES

UNIO SMRT Up to 2,7 kw capacity. Designed for the air-conditioning of large spaces. UNIO SMRT 10 SF od. 01491 UNIO SMRT 10 HP od. 01492 UNIO SMRT 12 SF od. 01493 UNIO SMRT 12 HP od. 01494 Two capacity versions: 2,3 kw - 2,7 kw vailable in versions: SF (ooling only) - HP (Heat Pump) Double class Refrigerant gas R410* Design by King e Miranda Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it. (only in HP version) electrostatic filter(which eliminates small SUPER OLD In version number 12 Unico Smart s cooling capacity can reach up to 2.7 kw. UNIO SMRT Weight kg mm 902 230 516 40 126

Indoor mbient Outdoor mbient UNIO SMRT 10 SF UNIO SMRT 10 HP UNIO SMRT 12 SF UNIO SMRT 12 HP Product code 01491 01492 01493 01494 Nominal cooling capacity (1) P rated kw 2,3 2,3 2,7 2,7 ooling power (min/max) (1) kw - - - - Nominal heating capacity (1) P rated kw - 2,3-2,5 Heating power (min/max) (1) kw - - - - Nominal power consumption for cooling (1) PEER kw 0,9 0,9 1,0 1,0 Power consumption for cooling (min/max) (1) kw - - - - Nominal absorption for cooling (1) 3,7 3,7 4,3 4,3 bsorption for cooling (min/max) (1) - - - - Nominal power consumption for heating (1) POP kw - 0,7-0,8 Power consumption for heating (min/max) (1) kw - - - - Nominal absorption for heating (1) - 3,0-3,3 bsorption for heating (min/max) (1) - - - Nominal energy efficiency index (1) EERd 2,6 2,6 2,6 2,6 Nominal efficiency coefficient (1) OPd - 3,1-3,1 Energy efficiency class in cooling (1) Energy efficiency class in heating (1) - - Energy consumption in thermostat off mode PTO 14,0 14,0 14,0 14,0 Energy consumption in standby mode (EN 62301) PS 0,5 0,5 0,5 0,5 Energy consumption for double pipe appliances (1) cooling QDD kwh/h 0,9 0,9 1,0 1,0 Energy consumption for double pipe appliances (1) heating QDD kwh/h - 0,7-0,80 Supply voltage V-F-Hz 230-1-50 230-1-50 230-1-50 230-1-50 Supply voltage minimum/maximum V 198 / 264 198 / 264 198 / 264 198 / 264 Maximum power consumption in cooling mode (1) W 0,9 0,9 1,1 1,1 Maximum absorption in cooling mode (1) 3,8 3,9 4,8 4,8 Maximum power consumption in heating mode (1) W - 0,9-1,1 Maximum absorption in heating mode (1) - 3,8-4,7 Maximum power consumption with electric resistance heating W - - - - Maximum absorption with electric resistance heating - - - - Dehumidification capacity l/h 0,9 1,1 0,9 1,1 ir flow rate in cooling environment (max/med/min) m³/h 490 / 430 / 360 490 / 430 / 360 490 / 430 / 360 490 / 430 / 360 ir flow rate in heating environment (max/med/min) m³/h - 410 / 350 / 270-450 / 400 / 330 ir flow rate with electric resistance heating environment m³/h - - - - External air flow rate in cooling (max/min) m³/h 520 / 350 520 / 350 520 / 350 500 / 340 External air flow rate in heating (max/min) m³/h - 520 / 350-500 / 340 Internal ventilation speed 3 3 3 3 External ventilation speed 3 3 3 3 Diameter wall holes mm 162 / 202 162 / 202 162 / 202 162 / 202 Electric resistance heating - - - - Maximum range remote control (distance / angle) m / 8 / ±80 8 / ±80 8 / ±80 8 / ±80 Dimensions (Larg. x lt. x Prof.) (without packaging) mm 902 x 516 x 229 902 x 516 x 229 902 x 516 x 229 902 x 516 x 229 Dimensions (Larg. x lt. x Prof.) (with packaging) mm 980 x 610 x 350 980 x 610 x 350 980 x 610 x 350 980 x 610 x 350 Weight (without packaging) Kg 40 40 40 40 Weight (with packaging) Kg 44 44 44 44 Internal sound pressure (Min Max) (2) d() 33-41 33-41 33-42 33-42 Internal sound power level (EN 12102) LW d() 56 56 57 57 Degree of protection provided by covers IP 20 IP 20 IP 20 IP 20 Refrigerant gas* Type R410 R410 R410 R410 Global warming potential GWP kgo2 eq. 2088 2088 2088 2088 Refrigerant gas charge kg 0,48 0,54 0,65 0,55 Maximum operating pressure MPa 3,6 3,6 3,6 3,6 Power cable (N pole x section mm 2 ) 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5 LIMITS OF OPERTING ONDITIONS Maximum temperature in cooling D 35 - W 24 Minimum temperature in cooling D 18 Maximum temperature in heating D 27 - Maximum temperature in cooling D 43 - W 32 Minimum temperature in cooling D -10 Maximum temperature in heating D 24 - W 18 D -15 (1) TEST ONDITIONS: data refers to regulation EN14511 (2): Data test declaration in semianechoic room at a distance of 2m, minimum sound pressure with ventilation only. - y maintaining the same center to center distance of inlet and outlet holes and the possibility of installation with 162 mm diameter holes, models in the Unico Smart, Unico Inverter and Unico ct range may easily substitute previously installed Unico Star and Unico Sky models. * hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088 S SiOS SYSTEM TERMINL UNITS UNIO FIXED IR ONDITIONER PORTLE IR ONDITIONER IR OOLER VM DEHUMIDIFIERS HUMIDIFIERS FN HETERS ERMI FN HETERS GS STOVES PERSONL OMFORT 127 PELLET STOVES

UNIO R Designed for the coldest climates. UNIO 10 HP od. 01495 UNIO 12 HP od. 01496 Two capacity versions: 2,3 kw - 2,7 kw vailable in versions: HP (Heat Pump) Double class Refrigerant gas R410 * +2 KW KUP UXILIRY Suitable even for the coldest temperatures. When external ambient temperatures are below 2, only the fan and the electric heaters are activated for the heating mode. For temperatures over 2, heating is obtained by means of the heat pump. The management of either mode is completely automatic. electrostatic filter (which eliminates small UNIO R Weight kg mm 902 230 516 40 128