Devices for Special Applications

Similar documents
Product and Applications Description

Description of the application programme for KNX occupancy detectors version 3.1

Product and Applications Description

UP 258E11 OPTISENS OFFICE

0701 CO Light, HVAC, Monitoring, Brightness

Use of the application program

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Connections, displays and operating elements C D E G H. Installing the control unit

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

Tebis application software

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

KNX/EIB - Product database - Application description

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

Operating instructions

Product and functional description

IP65 High Bay Dual Sense Sensor

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

IP65 High Bay Dual Sense Sensor

Install intelligent room automation flexibly and future-proofed

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

2. Safety. 4. Function

ABB i-bus EIB. Energy-optimised buildings. For authorised electricians only

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Synco-Gamma Application Guide. Retirement and nursing homes.

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

OPERATING INSTRUCTIONS

Controller - 4 x 1-10 V outputs - BUS/KNX

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

Data sheet. Function description. Benefits

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Synco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.

Sensors SR Programming manual

Sensors and Detectors

Connections, displays and operating elements E F. 20s 3min

Tri-level Control HF Sensor

SMART BASIC BASIC-IR DAYLIGHT

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

11,1 30. Ordering data

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Passive infrared ceiling sensor

LPC3BSP65 & LPC3BDP65

DALI MSensor 02 Multi-sensor for DALI system

Local Control Network - building controls in perfection

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Technical Manual MDT Motion Detector

False Ceiling HF Sensors

, ,

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

NOVEMBER 2017 Webinar New KNX Devices Nov JRA/S , LGS/A 1.2, TR/A 1.1. Webinar Competence Center Europe Building Automation

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Info-Display xx

Installer Manual KNX Touchscreen Thermostat

Busch-Watchdog presence. Overview and applications of presence detectors.

LPCMPIRM65 & LPCMPIRDSI65

Tri-level Control HF Sensor

FR-A180 FR-A360. Occupancy detector. Use

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Unpack, connect, done - no further work required

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

DALI MSensor 02 Multi-sensor for DALI system

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

DOCUMENTATION IPS640

DOCUMENTATION IPS640

ST3124. KNX Blind Actuator DC 4-fold. Operation and Installation Manual

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

1. Basic safety information 3 2. Proper use 3

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Stellar Panelboard Dimming Systems

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

HF Motion Sensor Introduction

North America Version / Dimming Function. Introduction

Built-in HF Sensor for High Bay

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

e.control Function overview

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Tri-level Control Sensor

1. Basic safety information 3 2. Proper use 3

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Transcription:

Overview AP 2/11 UP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 UP 2 AP 2 Control Integrated constant light level control 1-channel 3-channel -- -- -- 1-channel -- -- 1-channel -- 1-channel Integrated two-step control 1-channel -- -- -- -- 1-channel -- -- 1-channel -- 1-channel Light level control dependent on -- -- -- -- -- -- -- -- -- surrounding light Light sensor External light -- -- -- -- -- -- -- -- -- Indoor brightness -- -- -- -- -- Indoor brightness -- -- -- -- -- -- -- -- -- (indirect lighting) Transmission of brightness values over KNX -- -- -- -- Technical specifications UP 2/11 AP 2/12 N 26/02 UP 28/11 UP 28/21 N 342 AP24/02 GE 22 GE 23 GE 24 Enclosure data Design UP AP N UP UP N AP GE GE GE Modular installation device in oblong design, for -- -- -- -- -- -- -- installation in luminaires for fluorescent lamps Modular installation devices for mounting on -- -- -- -- -- -- -- -- TH3 EN 6071 mounting rail Dimensions Height mm 30 30 87 102 110 42 42 42 Width (1 MW = 18 mm) mm 2 2 6 MW 87 102 1 MW 72 274. 274. 274. Depth mm 33 33 60 33 4 28 28 28 Power supply Electronics powered over bus voltage -- -- Electronics powered over an integrated -- -- -- -- -- -- -- -- power supply unit, supply voltage 230 V AC Bus connection Integrated bus coupling units -- Plug onto UP 110 bus coupling unit -- -- -- -- -- -- -- -- -- Plug onto UP 114 bus coupling unit -- -- -- -- -- -- -- -- -- Bus connection via bus terminal -- -- Bus connection over contact system to data rail -- -- -- -- -- -- -- -- -- For selection and ordering data, see page /16. UP 2/11 AP 2/12 UP 2/11 UP 2/11 and AP 2/12 brightness controllers For measuring the brightness on an illuminated work area through measurement of the reflected light Measuring range 0... 2000 lux (with a reflectance of the illuminated area of 30 %) Including two rigid optical fiber rods: - Parallel light-sensitive surface for mounting surface - Inclined (4 ) light-sensitive surface for mounting surface Integrated infrared receiver for calibration of the brightness measurement over an infrared remote control Transmission of the brightness measured value, either in the event of change and/or cyclically Optional two-step dimmer control for lamps that can only be switched, or constant light level control for lamps that can be switched and dimmed For mounting in a hollow-wall or flush-mounting box with 8 mm and min. 40 mm mounting depth Setpoint can be adjusted either over a parameter or a communication object Starting value of the lighting can be selected when the constant light level control starts up Optionally with dimming of up to 4 further lamp groups To the dimming value of the constant light level control or to a dimming value that differs from the dimming value of the constant light level control by an offset value, which can be set per group Automatic deactivation of the constant light level control by manual BRIGHTER/DARKER dimming or dimming to a preset dimming value Configurable behavior in the event of a bus power recovery Cover made of white plastic (polystyrene) 30 x 2 x 33 mm AP 2/12 For ceiling or wall mounting Includes surface-mounting enclosure made of white plastic (polypropylene) with 70 mm and 24 mm in height 30 x 72 x 33 mm /14 Siemens ET G1 10/2008

N 26/02 AP 2 UP 2 N 342 UP 28/11 UP 28/21 AP 28E N 26/02 switch/dimming actuators, triple 3 x 230 V AC, 0/60 Hz, 6 A, with integrated constant light level control LED for status indication per input LED for status indication per output LED for operation/status indication Pushbuttons for local operation on the device 3 control outputs 1... 10 V DC Max. 0 ECG per output (Osram Dynamik 8 W) 3 floating relay contacts Rated contact voltage, 230 V AC Rated contact current 6 A 3 inputs for AP 2/UP 2 brightness sensors, max. 100 m cable length, unshielded, untwisted AP 2/UP 2 indoor brightness sensors For N 26/02 switch/dimming actuators For measuring the brightness on an illuminated area through measurement of the reflected light Measuring range: 0... 100 lux (with a reflectance of the illuminated area of 30 %) For direct connection to N 26/02 switch/dimming actuators over a 3-wired cable of up to 100 m in length, which also serves to power the sensor electronics Plug-in low-voltage terminal for connection of the cable to N26/02 Including two rigid optical fiber rods: - Parallel light-sensitive surface for mounting surface - Inclined (4 ) light-sensitive surface for mounting surface N 342 light level control modules Ten mutually independent light control functions that control the indoor lighting depending on the outdoor brightness Shared current outdoor light intensity value for all 10 light control functions, with light intensity measured by an outdoor brightness sensor and sent to a N 342 Separate brightness curve per light control function With configuration option per light control function as continuous dimming control for the detection and transmission of dimming commands to dimming or switch/dimming actuators or as 2-step control with hysteresis for detection and transmission of ON/OFF switch commands to switch actuators UP 28/11 presence detectors With brightness sensor Motion Presence Range on either side:. m Horizontal sensing angle: 360 Vertical sensing angle: 120 UP 28/21 presence detectors With constant light level control Motion Presence Horizontal sensing angle: 360 AP 28E surface-mounting enclosures UP 28/21 presence detectors For fixing the presence detector as a surface mounting device 102 x 102 x 46 mm Switching ON/OFF Configurable starting value ON/OFF switching possible over BRIGHTER/DARKER dimming BRIGHTER/DARKER dimming Adjustable dimming time Set 8-bit value Integrated constant light level control per output (outputs are master/slave-capable) Configurable behavior in the event of a bus power failure/recovery Send switching and dimming status Night mode (lighting for cleaning) UP 2 indoor brightness sensor For mounting in a hollow-wall or flush-mounting box with 8 mm and min. 40 mm mounting depth Cover made of white plastic (polystyrene) 30 x 2 x 33 mm AP 2 indoor brightness sensor For ceiling or wall mounting Includes surface-mounting enclosure made of white plastic (polypropylene) with 70 mm and 24 mm in height 30 x 72 x 33 mm Automatic adaptation (shifting) of the respective brightness curve to the desired new indoor brightness when the dimming value is manually changed (e.g. using a bus pushbutton) and restoration of the original curve when the lighting is switched off Measuring range: 100... 1600 lux (standard) 2... 200 lux (expanded) Transmission of sensor values over bus Vertical sensing angle: 120 Range on either side: 4 m Brightness measuring range 10... 100 lux Transmission of sensor values over bus Siemens ET G1 10/2008 /1

AP 24/02 GE 22 GE 24 GE 23 AP 24/02 dual sensors Brightness measurement, temperature measurement, sun protection control, lighting control For the detection and transmission of brightness and temperature, temperature measuring range -2 C... + C, brightness measuring range 1 lux... 100 klux, horizontal sensing angle -60... +60, vertical -3... +66. For the control of switch, dimming and shutter/blind actuators, depending on the ambient luminosity and/or ambient temperature One sun protection channel for the automatic control of sun protection equipment, with - Starting and stopping of automation over an object or a dusk threshold - Up to three brightness thresholds for determining the height and position of the shutters/blinds or roller shutters - Optional teach-in of dusk thresholds and brightness thresholds over a teach-in facility - Locking object for the temporary deactivation of the sun protection channel function GE 22 indoor brightness sensors 2 m connecting lead of sensor element (cannot be extended) GE 24 indoor brightness sensors With constant light level control, taking into account indirect lighting 2 m connecting lead of sensor element (cannot be extended) GE 23 outdoor brightness sensors For indoor mounting For measuring outdoor brightness 2 m connecting lead of sensor element (cannot be extended) Up to four universal channels for the control of switch, dimming and shutter/blind actuators, depending on ambient luminosity and/or temperature. Optionally available with: - Threshold switches for brightness - Threshold switches for temperature - Threshold switches with logical combination of brightness and temperature - Optional teach-in of brightness threshold for each universal channel over an associated teach-in facility - Deactivation option for each universal channel over an associated locking object (1 bit) - Optional second object for transmission of a second telegram on fulfillment of threshold conditions Electronics powered over bus voltage Integrated bus coupling units Bus connection via bus terminal Surface mounting Degree of protection, IP4 Brightness measuring range 200... 1900 lux Converter: 42 x 274. x 28 mm Receiver: 2 x 6.7 x 28. mm Brightness measuring range 0... 2000 lux Converter: 42 x 274. x 28 mm Receiver: 2 x 6.7 x 28. mm Brightness measuring range 0... 16000 lux Converter: 42 x 274. x 28 mm Receiver: 2 x 6.7 x 28. mm Selection and ordering data Version DT Order No. Price kg Unit(s)Unit(s) UP 2/11 UP 2/11 brightness controllers N B WG1 2-4AB11 1 1 030 0.030 WG1 2-4AB11 AP 2/12 AP 2/12 brightness controllers N B WG1 2-4AB12 1 1 030 0.00 WG1 2-4AB12 /16 Siemens ET G1 10/2008

Version DT Order No. Price N 26/02 N 26/02 switch/dimming actuators 3 x 230 V AC, 6 A, with constant light level control Unit(s)Unit(s) kg } WG1 26-1AB02 1 1 030 0.48 WG1 26-1AB02 UP 2 AP 2 UP 2 indoor brightness sensors N 26/02 switch/dimming actuators AP 2 indoor brightness sensors N 26/02 switch/dimming actuators } WG1 2-4AB01 1 1 030 0.092 C WG1 2-4AB02 1 1 030 0.102 N 342 N 342 light level control modules u B WG1 342-1AB01 1 1 030 0.092 WG1 342-1AB01 UP 28/11 UP 28/11 presence detectors 1) } WG1 28-2AB11 1 1 030 0.221 With brightness sensor WG1 28-2AB11 UP 28/21 UP 28/21 presence detectors With brightness sensors, constant light level control } WG1 28-2AB21 1 1 030 0.08 WG1 28-2AB21 AP 28E AP 28E surface-mounting enclosures For UP 28/21 presence detectors } WG1 28-3EB21 1 030 0.220 WG1 28-3EB21 AP 24/02 AP 24/02 dual sensors N Brightness measurement, temperature measurement, sun protection control, lighting control } WG1 24-3EY02 1 1 030 0.13 WG1 24-3EY02 1) The bus coupling unit must be ordered separately. Siemens ET G1 10/2008 /17

Light level control Version DT Order No. Price GE 23 GE 23 outdoor brightness sensors For indoor mounting Unit(s)Unit(s) kg } WG1 23-4AB01 1 1 030 0.34 WG1 23-4AB01 GE 22 GE 22 indoor brightness sensors } WG1 22-4AB02 1 1 030 0.34 GE 24 GE 24 indoor brightness sensors } WG1 24-4AB01 1 1 030 0.34 For indirect lighting WG1 22-4AB02 WG1 24-4AB01 7 /18 Siemens ET G1 10/2008