MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Similar documents
MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

LAUNDRY MONITORING SYSTEM Model # LIM-64S

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP AND UHV600-15HP-20850

Radiation Monitoring Systems

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

ß-Aerosolmonitor FHT 59 C

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

AERIAL RADIATION DETECTORS

Ronan Model X96S Series Density System

Radiation Monitoring Equipment

Ronan Model X96S Series Weighing System

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Radiation Monitoring System RMS

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

AS950 REFRIGERATED SAMPLERS

Centro-Matic Automated Lubrication Systems System Controls

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Constant climate chambers

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Identify the following features and specifications for the ESP1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model 1062 Environment Monitor

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Ronan Model X90 Series Point Level Monitor

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Portable Instruments For First Response & In-Situ Analysis of Radiation

Constant climate chambers

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Process Alarm Module RTA 421

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

Constant climate chambers

WASTEWATER Online UV%Transmission Analyzer

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Liquid Helium Level Instruments

stationary dose rate measuring systems

Constant climate chamber with humidity

HOBO U30 Remote Monitoring Systems

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Tri-Tech Medical Inc.

Upright Chromatography Refrigerators

Automatic Isokinetic Sampler ST5

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

Advanced Test Equipment Rentals ATEC (2832)

A New Standard of Excellence

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Constant climate chamber with ICH-compliant illumination

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

3500/61E & 3500/67E Temperature Monitor

Quality and Technology - Made in Germany -

DT968C C.T. BATH CONTROLLER

300/400 UNITS - MODULAR CONFIGURATION

Measurement Devices. Topic 5 - Audio 56

North American Technical Services

Alarm Tone Generator Model AG17

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

Section PERIMETER SECURITY SYSTEMS

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

MCS 4000 Control Panel

Laboratory Impex Systems Ltd

RAM GENE / RAM GENE-1

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

Series 5000 Hydrazine Analyzer Model 60002

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

DOUBLE DOOR FREEZER.

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

icam -HD High Flow Rate Alpha/Beta Air Monitor Radiation Safety. Amplified. DESCRIPTION KEY FEATURES BENEFITS OPTIONS

Power Flame Incorporated

Environmental Radiation Monitoring System

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

HIGH CAPACITY PRODUCT LINE

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Omniguard 4: Features

THERMOMETERS Dataloggers/Refrigerator

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Transcription:

- FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional) 2 CHANNEL AIR MONITOR SAAM-1HVM 1 CHANNEL AIR MONIOR SAAM-3 COUNTS SEPARATELY AND SIMULTANEOUSLY USB and/or ETHERNET OUTPUT Electronics Cabinet APPLICATION: Filter Paper Roll The SAAM Series Monitors are used for monitoring effluent from radioactivity utilizing or producing facilities either directly at the stack or other outlet or at the property boundary. The SAAM Series are designed to provide a complete record of activity for up to 45 days of unattended operation. This instrument automatically advances the filter. This avoids frequent manual filter replacement. Alarms are preset by user. OPTIONS: 1. Single Channel Analyzer window(s) specifically for Pu-239, and U-238 and/or other nuclides. 2. Clock and calendar give date and time of each reading. 3. Helium Flush for Alpha Spectroscopy.

DESCRIPTION: The SAAM-1HVM is a two channel air monitor for simultaneous measuring of gross Alpha, Beta/Gamma particulates. The SAAM-3 is a one channel monitor for Alpha emissions. Both monitors see Alpha less Radon. The SAAM-3 has plug in capacity for one or more channels of specific radiation energies, e.g.pu-239, U-238 etc. Like all of the SAAM series, these are continuous duty, high capacity, rugged skid or caster-mounted systems. Electronics are microprocessor with color LCD display. Also preamps etc. are plug-in modules allowing change or addition of function as needed and allowing rapid repair by substitution of modules in the field. Shields are void free lead encased in welded steel and with stainless steel liners for a long, useful life and easy decontamination. Filters are easily changed via quick disconnect, O-ring sealed filter holder. Shield can be opened for filter change or cleaning with minimum effort. All shield connections and openings are sealed against air leaks. The air moving system is based on a high capacity air pump capable of delivering 4 cfm with options up to 30 cfm free air and a real time electronic flow meter. The flow meter feeds directly into the TAquire software data analysis for more accurate calculation of airborne concentration and total activity. The entire system is mounted in a self-contained rugged cabinet and comes complete with all cabling and connectors in place ready to operate. The standard unit is operated from 120 V single phase, 60 Hz; 220 V optional, 50 or 60 Hz. The modular system is covered by T/A s unique exchange warranty, in addition to the full one year warranty covering all T/A products. SPECIFICATIONS: USER SETTABLE ENGINEERING UNITS ALARMS: Clear audio and visual alarms are provided. MODEL SAAM-3 & SAAM-1HVM SAAM-1HVM Channels: 1 2 Physical Form: Particulates Particulates Activity Detected: Alpha less Radon Beta/Gamma Detector Type: Solid State NaI(Tl) Scintillator Size: 1 Diameter 2 Diameter Model: SS-A1 PGS-3L16 Filters Media: Moving Filter Activated Charcoal Cartridge Size: 75mm x 100 meters 2.5 Diameter Construction: Standard or Glass Fiber Standard or Glass Fiber Standard Shielding: ½ Steel 3 (Pb) Lead Optional Shielding: 1 (Pb) Lead Sensitivity: 2 x 10-13 μci/ml 2 x 10-13 μci/ml

SPECIFICATIONS (continued): ELECTRONIC SYSTEM DESCRIPTION: Data Storage: Micro-processor includes: CPU with data acquisition High resolution, color Mouse Manuals Keyboard Color LCD Monitor Audio Onscreen Graphics (Built-in Printer Optional) Non-volatile memory 1 year. Data stored every 2 minutes all year. 1 terabyte hard drive: Stores programs, plus room to add additional new software functions in the future. Energy Analyzer: Power Supply: Fully adjustable single channel analyzer with independent High Voltage power supply. 1 ea. MVR-5R High Voltage Supply: Separately variable for each detector from 0 to 1500V. Standard FM-5 modular series. Display Monitor: Accuracy: Showing both real time concentration and accumulated dose for each channels. ±10% except for resolution loss and statistical variation. SPECIALIZED AIR MONITOR SOFTWARE. User settable Engineering Units. Calibration feature allows readout directly in uci/cc or Bq/m 3 or other units. Integrates results over an eight hour, or 24 hour interval. MENU OPTIONS: 1. Modify shift length 2. Change filter 3. Configure energies 4. alarms 5. Start shift 6. Calibration ALARMS: Alarms pre-settable to any trigger level. Low Level Alarm: Automatic Reset High Level Alarm: High level alarm remains activated until RESET is pushed. Alarm Indication: Red-High Level, Amber-Low Level Audio: 1000 Hz, greater than 80 db. Also see Safety Features below. AIR MOVING SYSTEM: Air pump: Extremely rugged continuous high capacity +Positive displacement pumping system. Ultra Low Noise Pump Pump Drive Motor: Flow Rate: Inlet and Outlet: 1 HP, 50/60 Hz, capacitor start, induction run. Electronic mass flow meter continuously informs analysis system. 20 foot 3/4 hose inlet: 20 foot 1 hose outlet. Length may be extended.

CONTROLS: System: Air: ON-OFF ON-OFF Alarms: (each channel) High Level Alarm: (each channel) High Level Alarm: (each channel) Low Level Alarm: (each detector) Voltage: (each detector) Energy Threshold/Window: Reset STANDARD SPECIFICATIONS: High Voltage Supply: Separately variable from 0 to 1,5000 VDC at 200 μa on scintillation or proportional channels. LCD Color Monitor: Accurancy: Alarms: Low Level Alarm: High Level Alarm: Alarm Indication Lights: Audio: Outputs: Standard Installation: Special Safety: Power: OPTIONAL: 17" Monitor shows both real time concentration & accumulated dose for all Channels +/- 10% except for resolution loss and statistical variation Alarms are pre-settable to any trigger level Automatic Reset High level alarm remains activated until RESET button is pushed 6 Lights Red-high level; Amber-low level count for each channel, plus more indicators shown on LCD Monitor. 1,000 Hz, greater than 80 db Alarm Condition Outputs: 1. Logic Level Signal 2. Contact Closure or Opening Ethernet USB Cabinet: heavy gauge steel. Skid or caster mounted Five inch ball bearing casters (4 each). Two of these are full 360 degree swiveling. Loss of system vacuum air flow alarm with relay switch closure. Loss of signal alarm. All system circuits fused. 120 VAC 220 VAC; optional 50/60 Hz Thermal protection on motor.

OPTIONS: Multi-Channel Gamma Energy Analyzer (MCA) with Isotope Identifier Multi-Channel Alpha Energy Analyzer (MCA) for Alpha Particulates Up to 3 Channels of 4-20mA Chart Recorder Drive or Communicate with the computer Skid Mount Grab Sample Port Available without air mover or with alternate air movers. Broader range 12 decades. Different detector types. Positive displacement of Roots Blower. Push-button Detect & Test sources (License exempt quantities) Flow rate can be increased to 30 cfm with larger pump and minor changes in the plumbing Lighter SAAM-1HVM system with less Shielding eg: 1 thick. WEIGHT, DEMENSION, SHIPPING: SAAM-1HVM Dimensions: 29'' wide x 31'' deep x 41'' high - exclusive of casters. Weight: 1600 lbs. Shipping Weight: 1750 lbs. SAAM-3 Dimensions: Weight: Shipping Weight: 24'' wide x 36'' deep x 41'' high - exclusive of casters. 175 lbs. 250 lbs.