Features. Figure 1. Recommended Application

Similar documents
Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

onlinecomponents.com

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Operating Instructions

Premier External TD. Installation Manual INS352-3

Chapter 7. Troubleshooting

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Austin Series Non-Isolated SMT DC - DC Power Modules: 3.3 Vdc and 5.0 Vdc Input, 1.5 Vdc Vdc Output, 6A

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Record of Amendments. Version Date Amendment Section/page affected

Operating Manual MS220KA and MSR220KA

DS1286 Watchdog Timekeeper

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Operating Manual MS220DA

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

AIRCRAFT ELECTRICAL POWER SYSTEM HOLDUP REQUIREMENTS

Government of India Ministry of Environment and Forests

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

Low-Power CMOS ALARM IC with Horn Driver

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Fortimo LED Line Gen2 Module


Piezoelectronic Buzzers

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Manual DRUM-HEATER DH27

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Fortimo LED Line High Flux Module

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

M7100 Pressure Transducer

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

PQS performance specification

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

DAWN Electronics, Inc.

Construction Electrical

TROPO 15W Dimmable LED Driver

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

DS1486/DS1486P RAMified Watchdog Timekeeper

Installation, Operating and Maintenance Manual

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Speed and Frequency Seite 1 von 7

INTRODUCTION Years. Test Temperature [ C]

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

MicroCoat Flow Guard Operating Manual

Remote NAC Power Supply D7038

Instructions for the fan motor control system, SILVER C

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

C-Bus Four Channel General Input Unit Installation Instructions

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

4 & 8-POINT ANNUNCIATORS Instruction Manual

Multi Layer Varistor Overvoltage Protection Device

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Universal controller for panel mounting Models CS6S, CS6H, CS6L

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

Pyroelectric Infrared Sensors

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

A5364. Ionization Smoke Detector with Interconnect

ECC-50/100C. Emergency Command Center

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Use & Care Manual Contemporary Electric Fires

RADIATION FROST DETECTOR

Owner & Operator s Manual. Table of Contents

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

LC3000 Level Controller Installation and Maintenance Instructions

Proservo NMS5- / NMS7-

HEP Tech Co., Ltd. Company Profile

Room air quality sensors

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

FEC403EN Installation Manual

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

SF100 User Manual Version 1.0

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

3kW 6kW, QUBE Fiber Lasers

PROCESSING UNIT II V Hz V Hz. Table of Contents

G4 Pulsed Fiber Laser

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

+ + + EUGEN WOERNER. Level Switch KFA-A. Two switching points for level monitoring max.

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Transcription:

Features High energy density User programmable hold-up trip voltage Trip status indicator Designed for use with Calex DC/DC Converters Small package design (1.45 x 2.28 x 0.50 ) Excellent MTBF Aluminum substrate technology All applicable materials used are a minimum of UL94V-0 rated. Designed to meet UL60950. Five year warranty Available with RoHS compliant construction, simply add (RoHS) after the part number: HUL-28 (RoHS) Description The HUL-28 is a hold-up module designed for use with Calex DC/DC converters to protect against brown-out and temporary power loss conditions and provide a clean, uninterrupted source of power for downstream circuitry. The HUL-28 is built in a small package with a user programmable hold-up trip voltage. Figure 1. Recommended Application

Principles of Operation The HUL-28 has two modes of operation: stand-by and tripped. During stand-by, the HUL-28 charges the holdup capacitor to 45V and maintains that voltage. When tripped, the HUL-28 stops charging the hold-up capacitor and connects it to the Vout pins. The mode of operation is determined by the value of the input voltage (+INPUT) in relation to the trip voltage. Tripped mode is entered when the input voltage drops below a preset trip voltage. Stand-by mode is entered when the input voltage rises 2.1V above the trip voltage. The trip voltage is set by the user via the Vprog pin. Thermal Considerations In stand-by mode, the HUL-28 does not dissipate much heat and the baseplate temperature will typically be 5ºC higher than ambient temperature in a still air environment. When the HUL-28 transitions from tripped to standby mode and vice versa, a large amount of power is dissipated in the HUL-28. If frequent transitions are expected, care should be taken to ensure the baseplate temperature does not exceed 100ºC. Caution After shutting off power to the HUL-28, do not handle the circuit until the hold-up capacitor is discharged. With no load on the output, voltages in excess of 45V may be present on the Vcap and Vout pins for a prolonged period of time. Figure 2. Internal Block Diagram Hold-up Time Hold-up time is defined as the maximum time that the downstream circuitry can be powered solely from the hold-up capacitor. In this data sheet, hold-up time is defined as the time when the downstream circuitry is powered solely from the hold-up capacitor and the holdup capacitor is charged to at least 10V. The following table illustrates the maximum hold-up time (ms) achievable with different capacitor configurations. Capacitance (mf) Power (W) 60 120 180 10 160ms 80ms 53ms 20 321ms 160ms 107ms 30 481ms 241ms 160ms 40 642ms 321ms 214ms 50 802ms 401ms 267ms 2

Input Parameters Input Voltage (3) Input Current, hold-up capacitor charged Input Current while charging hold-up capacitor 15.5 28 36 25 marms 20 350 Input Overvoltage, 100ms 50 Switching Frequency 310 khz Reflected Ripple 40 ma p-p Recommended Input Fuse Note (2) Output Parameters Hold-up Cap voltage (pin 6 and pin 7) Hold-up Cap Charge Rate (0-45V) 44 45 46 278 ma Hold-up Capacitor (Ch) 50,000 µf Response Time (4) 5 µs Vcap to Vout Voltage Drop 0.6 Hold-up Output Power 200 W Vout Voltage 9.0 45.5 Output Capacitance (5) Tc 80ºC 350 Control Parameters Tc 100ºC 170 Trip Voltage Vprog = 0V Vprog Open Vprog = 5V 21.4 22 22.5 17.5 18 18.5 13 13.5 14 s F µf Trip Voltage Hysteresis 2.1 Vprog Voltage 0 5 Input Impedance 24 kω Status Pin Voltage 50 Status Pin Current 2 ma Notes: (1) All parameters measured at Tc=25ºC, Vin=28, unless otherwise noted. Refer to the CALEX Application Notes for the definition of terms, measurement circuits, and other information. (2) Refer to the CALEX Application Notes for information on fusing. (3) Minimum operating voltage is affected by the value of the trip voltage. (4) The response time is defined as the time from when the input voltage drops to the trip voltage to the moment when the output voltage Vout starts rising. (5) This capacitance includes all input capacitance on the downstream circuitry: internal capacitance and Co. (6) Isolation is measured by applying a DC voltage between pins and baseplate. (7) The case thermal impedance is defined as the case temperature rise over ambient per package watt dissipated. (8) Thermal impedance is tested with the module mounted vertically and facing another printed circuit board 1/2 inch away. (9) Torque fasteners into threaded mounting inserts at 12 in. oz. or less. Greater torque may result in damage to unit and void the warranty. (10) Calex CBAM modules are designed to withstand most solder/wash processes. Careful attention should be used when assessing the applicability in your specific manufacturing process. The CBAM modules are not hermetically sealed. (11) MTBF is calculated based on MIL-HDBK-217F under the following conditions: Reliability prediction method = Part Stress Analysis Baseplate temperature = 40ºC Environment = Ground, Benign (12) Available with RoHS and Non-RoHS construction, contact factory for details. RoHS Compliance means conformity to EU Directive 2002/95/EC of 27 January 2003, on the restriction of the use of certain hazardous substances in electrical and electronic equipment, lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers are not present in quantities exceeding the following maximum concentrations in any homogeneous material, except for applicable exemptions. 0.1% (by weight of homogeneous material) lead, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, or 0.01% (by weight of homogeneous material) cadmium. The RoHS marking is as follows. 3

Isolation Baseplate to Input (6) 700 Enviromental Baseplate Operating Temp Range Storage Temperature Range -40 100-40 120 Case Thermal Impedance (7), (8) 13 ºC/Watt MTBF MIL-STD-217F (11) 365,308 h General Unit Weight 55 g Case Dimension 1.45 x 2.28 x 0.50 Torque on Mounting Inserts (9) 12 in. oz ºC ºC Pin Diameter Name 1 0.040 GND 2 0.040 STATUS 3 0.060 VPROG 4 0.060 +INPUT 5 0.060 GND 6 0.040 VCAP 7 0.040 VCAP 8 0.040 VOUT 9 0.060 VOUT Mechanical tolerances unless otherwise noted: X.XX dimensions: ±0.020 inches X.XXX dimensions: ± 0.005 inches 4

HUL-28 Application Section Hold-up Time Hold-up time, as defined earlier, depends on downstream circuitry power draw, power loss in the HUL-28, the size of the hold-up capacitor, and the initial voltage of the hold-up capacitor. Generally, for a C farad capacitor charged to V volts, the amount of energy available to provide hold-up is: E = 1 C V 2 1 2 2 C 10 2 Advantages of the HUL-28 in attaining the desired hold-up time The bulk capacitance method (figure A2) can be used to provide hold-up without using the HUL-28. However, for any desired hold-up time, less capacitance will be required with the HUL-28. Furthermore, for the same hold-up time, the HUL-28 draws significantly lower inrush current. Therefore, a load drawing P watts will be supplied for t seconds: E 1 C t = (V 2-10 2 ) P = 2 P Assuming full 45V charge in the hold-up capacitor, constant power draw, and no loss in the HUL-28, the hold-up time can be estimated by: t h = 1 2 C (45 2-10 2 ) P where th is the hold-up time in seconds. Figure A1 allows for a quick estimate of hold-up time based on hold-up capacitance at three levels of power draw. In the case of a 84% efficient converter delivering 100W, the power drawn from the HUL-28 would be 119W. Figure A2. For any given combination of capacitance and power draw, figure A3 shows how the HUL-28 improves holdup time over the bulk capacitor solution. Equivalently, for any desired hold-up time at a given load, figure A3 shows how many times more hold-up capacitance is required without the HUL-28. Hold-up time (s) Improvement Hold-up capacitor, Ch (mf) Figure A1. Hold-up time as a function of capacitance and power draw Note that this hold-up time can only be achieved after the hold-up capacitor has been fully charged. Therefore the hold-up time is reduced or non-existent whenever the hold-up capacitor is not charged to 45V. This condition is present immediately after start-up and immediately after recovering from a brown-out. Power loss due to the voltage drop from Vcap to Vout will slightly reduce this theoretical hold-up time. Line Voltage (V) Figure A3. Improvement in hold-up time for a given combination of capacitance and power draw Consider a Calex 24S15.10HEW converter operating from a 28V bus. 100ms hold-up time is desired. The converter is supplying a 7A, 15V load. at 86% efficiency, the converter is drawing 122W. From figure A1, it is estimated that 12.5mF of capacitance is required if using the HUL-28. If hold-up is provided by the circuit shown in figure A2, the hold-up capacitor only charges to the line voltage (28V). From figure A3, 2.8 times more capacitance, that is 35mF, would be required. If during normal operation, the line voltage is allowed to drop to 16V, 12 times more capacitance (150mF) would be required. With the HUL-28, hold-up time is not affected by line voltage. 5

Trip Voltage Set-point There are three ways to set the trip voltage for the HUL-28. I. Connect a voltage source (0 to 5V) to Vprog to obtain any trip voltage between 13.5V and 22V. The trip voltage may be computed as: Trip Voltage (V) Vtrip = 21.9-1.69Vprog Alternately it can be estimated from figure A4. Resistance (kω) Figure A6. Trip voltage as a function or resistance connected between Vprog and +INPUT Trip Voltage (V) Vprog (V) Figure A4. Trip voltage as a function of Vprog Figure A7. External resistor method for obtaining a trip voltage greater than 18V II. For 18V trip voltage, leave Vprog open. Hysteresis is reduced to 1.6V. III. External resistor method. This method allows the trip voltage to be set to any value between 13.5V and 22V, without using a separate voltage source. However, using this method, the hysteresis is reduced to as low as 1V, therefore stand-by mode may be entered whenever the line voltage rises as low as 1V above the trip voltage. a. For a trip voltage smaller than 18V, connect a resistor between Vprog and +INPUT as shown in figure A5. The trip voltage can be estimated from figure A6. b. For a trip voltage greater than 18V, connect a resistor between Vprog and GND as shown in figure A7. The trip voltage can be estimated from figure A8. Trip Voltage (V) Resistance (kω) Figure A8. Trip voltage as a function of resistance connected between Vprog and GND Follow these steps to pick a trip voltage: 1. Decide on the lowest acceptable voltage for the downstream circuitry. 2. Compute or measure the change in voltage on the positive input of the downstream circuitry during the 5µs HUL-28 response time. This depends on downstream circuitry input capacitance (both internal and external), power draw, and trip voltage. 3. To obtain the trip voltage, add the two values above and the forward voltage drop of the input diode Di. Figure A5. External resistor method for obtaining a trip voltage smaller than 18V 6

Status Pin Pin 2, STATUS, allows external circuitry to monitor the state of the HUL-28 as shown in the table below. This pin is connected to the open drain of a FET, therefore a pull-up resistor to the logic high voltage is required for normal operation. Status Pin logic low logic high HUL-28 Status Tripped Stand-by Figure A11. HUL-28 properly configured to avoid high currents through the module Figure A9 shows an arrangement where a TTL compatible signal is generated at the STATUS pin. Vprog is open, therefore the trip voltage is 18V. The voltage on +INPUT is ramped down then up. Figure A10 shows the behavior of the STATUS pin. Note that the HUL-28 returns to stand-by mode only after +INPUT rises about 2V above the trip voltage. Figure A12a. Incorrect configuration: Hold-up current through HUL-28 Figure A9. STATUS pin configured for TTL operation Figure A12b. Incorrect configuration: Converter current through HUL-28 Hysteresis and Lack of Brown-out Protection Figure A10. STATUS pin operation. ch1: +INPUT voltage, ch2: STATUS voltage Ground Connection There are two GND pins (1 and 5) on the HUL-28. Avoid running current through the module from one pin to the other. The correct configuration is shown in figure A11. Some incorrect configurations are presented in figures A12a and A12b. Once the HUL-28 trips, the hold-up capacitor will not be recharged until the input voltage rises 2.1V above the trip voltage. If, after the HUL-28 is tripped, the input voltage recovers but does not rise at least 2.1V over the trip voltage, the HUL-28 will not provide any protection from any subsequent brown-out. Consider the following scenario: The trip voltage is 18V. The line voltage (28V) drops out for 500ms. Uninterrupted power is provided by the HUL-28. The line recovers, but only to 19V. The HUL-28 remains in tripped mode, as the line voltage does not rise above 20V. Another 400ms brown-out occurs after which the line voltage fully recovers to 28V. Since the hold-up capacitor is only partially charged the HUL-28 can not keep the load running. This is illustrated in figure A13. The same experiment is repeated after setting Vprog to 3.5V for a trip voltage of 16V. The results are shown in figure A14. To avoid this problem, set the trip voltage 2.1V lower than the lowest permissible value for the line voltage. 7

HUL-28 Input Capacitance Ci and Co shown in figure 1 are optional and are not required for the proper operation of the HUL-28. Co may be used if downstream circuitry requires external capacitance. If the required input capacitance is greater than the limit set by the HUL-28 output capacitance, Ci may be used in parallel with Co to attain the desired capacitance. When the HUL-28 is used with Calex HEW series converters, 220µF for Ci and 40µF for Co are recommended. Depending on operating conditions and converter model, other values may be required. Measurements Figure A13. HUL-28 does not provide protection due to high trip voltage. Figure A15. Brown-out event Figure A14. Lower trip voltage allows the HUL-28 to provide protection. Layout Issues +INPUT connection. Connect +INPUT directly to the anode of the input diode, Di. This will provide the best measurement of the input voltage. Stray Inductance on Output. Care must be taken to reduce stray inductance that may be present between the hold-up capacitors, the HUL-28, and the downstream circuitry. When HUL-28 trips, the voltage on Vout will suffer a step rise as large as 35V. This will be accompanied by a 35A inrush current into the output capacitance. Inductance present in the path of this current will cause a large voltage spike and/or ringing on Vout. Figure A16. Start of brown-out event in figure A15 8

Figure A17. End of brown-out event in figure A15 Figure A20. HUL-28 input current (ch4) with respect to hold-up capacitor voltage (ch1) at +INPUT = 36V Figure A18. HUL-28 input current (ch4) with respect to hold-up capacitor voltage (ch1) at +INPUT = 15.5V Figure A21. Typical input current ripple (ch4) while hold-up capacitor is charging (ch1) Figure A19. HUL-28 input current (ch4) with respect to hold-up capacitor voltage (ch1) at +INPUT = 28V Figure A22. Typical input ripple when HUL-28 is in standby mode 9