Catalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Similar documents
Catalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Ozone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.

Ammonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Smoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

Air-Quality Gas Sensor (Model:MP503) Manual. Version:1.3. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

ZP04 Flammable Gas Detection Module (Model:ZP04) Manual V1.1. Zhengzhou Winsen Electronics Technology Co., Ltd

Air-Quality Detection Module. User s Manual

Air-Quality Detection Module. User s Manual

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

Manual Zhengzhou Winsen Electronics Technology Co., Ltd

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

TC100N. Fixed Gas Detector Operation Manual

QD6310. Fixed Gas Detector Operation Manual

VQ500 Series Combustible Gas Detector Elements

General safety precautions English

General safety precautions English

KAE Gas Alarm Operation Manual

E1000 Portable gas detector

KAB Gas Alarm Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Operation and Maintenance Manual

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

IRceL CH4 Methane (CH 4

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

Xgard. Fixed detectors For flammable, toxic or oxygen gases

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

BEP Marine Gas Detector FD-2

BEP Marine Gas Detector 600-GDRV

an ISO9001 company APPLICATION NOTES FOR TGS2611 Application Notes for Methane Gas Detectors using TGS2611

INTELLIGENT LEAD FREE SOLDERING STATION INSTRUCTION MANUAL V1.0 WARNING

General safety precautions English

General safety precautions English

General safety precautions English

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

IMR IX176 Portable Gas Detector User Manual

Pyroelectric Infrared Sensors

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

General safety precautions English

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Models TX-KE and TX-KP Toxic Gas Transmitters

Technical data sheet TDS0060

M004 combustible gas module

DP86 Constant Voltage with Fitting

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

IR25 Dual Gas Series Datasheet

GD Series Gas Alarm Operation Manual

Application Notes For LED Displays

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Pyroelectric Infrared Sensors

MICROpeL 75 Combustible Gas Sensor Part Number: PM

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Key Features. General Description

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

APPLICATION NOTES for LED DISPLAYs

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

E-17 Flammable Gas Detection and Alarm System

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

FagronLab NP-1 UV. Negative pressure workbench. User Manual

an ISO9001 company APPLICATION NOTES FOR TGS2610 Application Notes for LP Gas Detectors using TGS2610

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Dräger Polytron Pulsar 2 Open Path Gas Detector

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

Installation and Wiring 1.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Instruction manual CCU 5-P. Table of contents

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

86BSD Digital Output

Standard SPECIFICATIONS FEATURES APPLICATIONS

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

MSP100 Pressure Transducer

ALTAIR 5X Multigas Detector Product Specification

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Transcription:

Catalytic Gas Sensor (Model: MC113/ MC113C) Manual Version: 1.3 Valid from: 2014-05-01 Zhengzhou Winsen Electronics Technology Co., Ltd

Statement This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can t spread through electronic, copying, record ways. Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc, please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users comments on optimized using way are welcome. Please keep the manual properly, in order to get help if you have questions during the usage in the future. Zhengzhou Winsen Electronics Technology CO., LTD

MC113/ MC113C Catalytic Flammable Gas Sensor Profile MC113/ MC113C adopts catalytic combustion principle, and its two arms of electric bridge consists of a test element and a compensate element. The resistance of the test element rises once it meets the combustible gases, in the same time, the output voltage of the bridge changes and the voltage variation rises in direct proportion to the gas concentration. The compensate element, as a conference, has the function of compensating temperature and humidity. Features It has good sensitivity to methane in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc. The bridge output is linear, quick response, good repeatability and selectivity, good stability, excellent resistance to the interference of H2S gas and organosilicone. Main Applications It is widely used in industrial occasion to detect the concentration of natural gas, LPG, CO and alkanes. It is also used in combustible gas leakage alarm system, combustible gas detector and gas concentration meter and so on. + 2.8V - + Fig1. Sensor Structure Fig2. Basic Test Circuit

Technical Parameters Sensor Type Model MC113/ MC113C Catalytic Standard Encapsulation Metal, Metallurgy powder mesh Working voltage(v) 2.8±0.1 Working current(ma) MC113: 90±10; MC113C: 95±10 Sensitivity (mv) 1% CH4 MC113: 20 to 40; MC113C: 16 to 35 1% C3H8 MC113: 30 to 60; MC113C: 25 to 55 Linearity 5% Measuring range(%lel) 0 to 100 Response Time (90%) Recovery Time (90%) Working Environment Storage Environment 10s 30s -40 to +70, less than 95%RH -20 to +70, less than 95%RH Size (mm) MC113: 19 9.5 14; MC113C: 14 8 10 Anti-explosion Mark ExdibⅠ Sensitivity, response and recovery Fig3. Sensitivity Curve Changing of output signal at different temperature Temp. Characteristic Fig4. Response and recovery curve Temp. Characteristic Temp. Temp. Fig5.Zero point at different temp. Fig6. Sensitivity at different temp.

Changing of output signal at different humidity Output(mV) Humidity Characteristic Output(mV) Humidity Characteristic Humidity Humidity Fig7.Zero point at different humidity Fig8. Sensitivity at different humidity Changing of output signal with different voltage supplying Output(mV) In Air In 1%CH4 In Air 2.6 2.7 2.8 2.9 3.0 Fig9. Zero point with different voltage Fig10. Sensitivity with different voltage Long-term Stability The drift in air per year is within ±2mV, in 1%CH 4 is within ±2mV. For a short period storage (in 2 weeks), the sensor need be galvanical continuously for 8 hours to reach stability. For more than one year storage, it need more than 48 hours. Fig11. Sensitivity fluctuation Time (weeks)

Cautions 1. Following conditions must be prohibited 1.1 Exposed to organic silicon steam Sensing material will lose sensitivity and never recover if the sensor absorbs organic silicon steam. Sensors must avoid exposing to silicon bond, fixature, silicon latex, putty or plastic contain silicon environment. 1.2 High Corrosive gas If the sensors are exposed to high concentration corrosive gas (such as H 2 S, SO X, Cl 2, HCl etc.), it will not only result in corrosion of sensors structure, also it cause sincere sensitivity attenuation. 1.3 Alkali, Alkali metals salt, halogen pollution The sensors performance will be changed badly if sensors be sprayed polluted by alkali metals salt especially brine, or be exposed to halogen such as fluorine. 1.4 Touch water Sensitivity of the sensors will be reduced when spattered or dipped in water. 1.5 Freezing Do avoid icing on sensor s surface, otherwise sensing material will be broken and lost sensitivity. 1.6 Applied higher voltage Applied voltage on sensor should not be higher than stipulated value, even if the sensor is not physically damaged or broken, it causes down-line or heater damaged, and bring on sensors sensitivity characteristic changed badly. 1.7 Pins connection When the sensor is connecting to the circuit, one of detection part pins and one of compensation part pins connects as the signal output. The other one of detection part pins connects negative electrode, while the other one of compensation part pins connects positive electrode. The part with mark is the detection part( for the separate type sensor, the one part with bigger hole is detector part),the other part is the compensation part. 2. Following conditions must be avoided 2.1 Water Condensation Indoor conditions, slight water condensation will influence sensors performance lightly. However, if water condensation on sensors surface and keep a certain period, sensors sensitive will be decreased. 2.2 Used in high gas concentration No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage. 2.3 Long time storage The sensors resistance will drift reversibly if it s stored for long time without electrify, this drift is related with storage conditions. Sensors should be stored in airproof bag without volatile silicon compound. For the sensors with long time storage but no electrify, they need long galvanical aging time for stability before using. The suggested aging time is 24 hours at least if the storage time is more than half an year. 2.4 Long time exposed to adverse environment No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high humidity, high temperature, or high pollution etc., it will influence the sensors performance badly. 2.5 Vibration Continual vibration will result in sensors down-lead response then break. In transportation or assembling line, pneumatic screwdriver/ultrasonic welding machine can lead this vibration. 2.6 Concussion If sensors meet strong concussion, it may lead its lead wire disconnected. 2.7 Usage Conditions 2.7.1 For sensor, handmade welding is optimal way. The welding conditions as follow:

Soldering flux: Rosin soldering flux contains least chlorine Homothermal soldering iron Temperature: 250 Time:less than 3 seconds 2.7.2 If users choose wave-soldering, the following conditions should be obey Soldering flux: Rosin soldering flux contains least chlorine Speed: 1-2 meter per minute Warm-up temperature:100±20 Welding temperature:250±10 One time pass wave crest welding machine If disobey the above using terms, sensors sensitivity will be reduced. Zhengzhou Winsen Electronics Technology Co., Ltd Add: No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 450001 China Tel: +86-371-67169097/67169670 Fax: +86-371-60932988 E-mail: sales@winsensor.com Website: www.winsen-sensor.com