XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Similar documents
CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

2 x screws. 2 x wall plugs

SZ-PIR04N ZigBee Motion Detector Installation Guide

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Optima ZigBee Thermostat

CLIP PG2. Installation Instructions. PowerG Wireless, Curtain, PIR Motion Detector 1. INTRODUCTION 2. INSTALLATION. 2.1 General Guidelines

Automatic Dimming Mirror with HomeLink

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Wireless External Alarm

1126 Series Ceiling Mount PIR Motion Detector

Wireless Weather Station

Pet Immune SAW PIR Motion Sensor

1100D Wireless Receiver

1100X Wireless Receivers

Smart Hub THERMOSTAT. Installation Manual

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

ShockLink. Important Product Information.

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

1125 PIR Motion Detector

Wi-Fi DOOR/WINDOW SENSOR

InTemp CX Temperature Logger (CX40x) Manual

EN1221S-60 Waterproof Pendant Installation and Operation Manual

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Rev D 3/20/17

PET IMMUNE PIR MOTION DETECTOR

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart THERMOSTAT. Installation Manual

ADT. Pulse 2017ADT LLC

Atomic Digital Office Clock

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

Draft - develop and review

Touchscreen Comfort Control

Impassa CDMA Module INSTALLATION GUIDE

Door/Window Sensor Installation Instructions

TX3 Series. TX3 InSuite. User Guide

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

Installation Instructions

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

S541.RF 4G Product Guide

Water Sensor. Model CFWS10

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Wireless Outdoor Air Reset Adaptor PN:

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

EL-TSTAT Owner s Manual

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

OPTIMA ZigBee Thermostat

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

EN1221S-60 Waterproof Pendant Installation and Operation Manual

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

INSTEON Wireless Thermostat Owner Manual (#2441ZTH)

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

Smoke Bridge Owner s Manual

Features and content. This is where air comes into your detector.

Intelli-Time Alarm Clock model 13041RM

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

HOBO MX Temp/RH Data Logger (MX1101) Manual

Tech Support Line: (715) Concord 4 RE927X

1164/1164NS WIRELESS SMOKE DETECTOR

External Wireless Sounder

Smart Radon Detector with Indoor Air Quality Sensors

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

ZTS-500US Z-Wave Smart Thermostat

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Flash 3 times per 3 seconds: Under voltage indication, please

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Installer Guide smart connect

GARAGE DOOR OPENER KIT

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

PRODUCT DIAGRAM PACKAGE CONTENTS

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

HSD-200Z Z-Wave Motion Sensor

PRODUCT DIAGRAM PACKAGE CONTENTS

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

Home Doorway Alert Kit

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Immunity. P/N: ver.b

Description. Optex Incorporated

Caught a critter in the act?

status AW1 Plus WiFi Alarm System User Manual

9000P Wireless Alarm Owner s Manual

Install Guide TP-2014-IG-V02

Badge Reader BR Installation Guidelines. Product Summary

Installer Guide smart connect

Panel XTO210/610/710 GPRS

Contents. User Manual GA-U-1. VultureNet: Long Range System

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Transcription:

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector Installation Instructions 1. INTRODUCTION The XHS1-TY or MP-841 (pet immune) is a microprocessor-controlled wireless digital PIR detector supported by ZigBee HA 1.2. The detector s features are as follows : Up to 15 meters (49.2 ft) Uniform Detection White light immunity (Black mirror technology) Enhanced Pet immunity up to 85Ibs (Target Specific Imaging (TSI) technology (patented) Enhanced false alarm rejection (The advanced True Motion Recognition algorithm (patented) No vertical adjustment is needed. In normal mode, after detection, the detector goes to sleep to save battery power. It wakes again (reverts to the ready state) if there is no subsequent detection throughout the following 2-minute period. Temperature compensation. Front and back tamper protection. Black mirror technology provides excellent white light protection. Elegantly styled, sturdy case. A. Red LED B. Green LED C. Tamper Switch Figure 1 - MP-841 D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST 1

. SPECIFICATIONS Detector Type Optical Data Max. Coverage 15 x 15 m, (49.2 x 49.2 ft) / 90 Pet Immunity Up to 38 kg (85 lb) ELECTRICAL Dual element low-noise pyroelectric sensor 27 far parabolic black mirrors (54 beams ) 9 near cylinder black mirrors (18 "curtains ) Pet immune protection is provided by a specific optical attenuator on the mirror Internal Batteries Nominal Battery Capacity Battery Life (with LED on) Battery Power Test Two 3V Lithium batteries, type CR-123A. For UL installations, use Panasonic, and GP only 1400 mah Typically over 5 years Note: Inability to connect with wireless network, or wireless link quality no higher than 20% may significantly reduce the expected battery life. Performed immediately upon battery insertion and periodically after every several hours FUNCTIONAL Alarm Period Visual Indications Rearm Timer 3 seconds Red LED lights for about 3 seconds upon transmission of alarm & tamper messages and upon motion detection in the walk test mode only. Red LED flashes during the power-up stabilization period, or after restoring (pressing) the tamper switch. Red LED does not light upon transmissions of supervision messages or alarm detection after termination of walk test mode. Rearms the detector 2 minutes after the last alarm. Timer disabled in the walk test mode WIRELESS Supported Network ZigBee H.A 1.2 Frequency 2.405 2.480 Ghz as per IEEE 802.15.4 Tamper Alert Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored PFD Signaling at 5 minute intervals Check in Signaling at 27 minute intervals MOUNTING Height Installation Options 1.8-2.4 m (6-8 ft). For pet rejection, the optimal height is 2.1 m (7 ft) Surface or corner ENVIRONMENTAL RFI Protection >20 V/m up to 1000 MHz Operating Temperatures -10 C to 50 C (14 F to 122 F Storage Temperatures -20 C to 60 C (-4 F to 140 F) COMPLIANCE WITH STANDARDS USA CFR 47 part 15, Canada: RSS 210 PHYSICAL Size (H x W x D) 83 x 61 x 42 mm (3.27 x 2.4 x 1.66 ) Weight (with battery) 90 g (3.17 oz) Color White PATENTS U.S. Patents 5,693,943 6,211,522 2 D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST

3. INSTALLATION 3.1 General Guidance 1. Keep away from heat sources. 2. Do not expose to air drafts. 3. Do not install outdoors. 4. Avoid direct sunshine. 5. Keep wiring away from power cables. 6. Do not install behind partitions. 7. Mount on solid stable surface. Figure 2. General Guidelines 3.2 Installation Procedure Figure 3 Opening the Unit Figure 4 Bracket Mounting Figure 5 Removing activation strip Figure 6 Mounting Detector on Bracket D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST 3

1. Press in this point. 2. Push in the direction of the arrow shown in the drawing to separate the detector from the bracket. 3. Mount the bracket on the wall. 4. Install new batteries. -OR- If batteries are already installed, pull the activation strip. 5. Mount the detector on the bracket by sliding it downward until a click is heard. A. Use A1 or A2 for corner mounting B. Use for surface mounting C. Activation strip Note: It is recommended to wait about 1 minute after battery removal, before inserting the new battery. Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to the manufacturer's instructions 3.3 Replacing the Batteries 1. Press upward to separate the detector from the bracket. 2. Replace the batteries. 3. Put back the detector on the bracket. Figure 7 Replacing Batteries 3.4 Activating and Pairing the Detector To pair the detector to the Touchscreen (control panel), you must set it to pairing mode. 1. First set the Touchscreen (panel) to pairing mode and then the detector. 2. To activate, pull the activation strip that protrudes from the back of the detector (see Figure 5). 3. The green LED (see Figure 1) blinks 3 times every 5 seconds (repeated up to 20 times) to indicate that the detector is searching for the Touchscreen (control panel). Note: If detector pairing is not successful during the searching process by tripping the motion detector or by pressing the tamper switch the searching process will restart. 4. Complete the pairing procedure on the Touchscreen (control panel) (see the pairing instructions in the Touchscreen / control panel s installation guide). Note: Pairing should be performed before installation. (Detector installation will have a good link with panel, if RSSI indicated on the Panel higher than -70BM and LQI stronger than 250. If values of RSSI and LQI are lower, change Detector placement) 3.5 Rebooting the Detector You can reboot the detector, as follows. 1. Remove the battery cover. 2. Press and release the tamper switch for 1 to 2 sec. (see Figure 1). 3. Close the battery cover. 4 D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST

3.6 Defaulting the Detector CAUTION! The defaulting process removes the device from the network and enables re-pairing. Separate the detector from the bracket to remove both batteries. (see Figure 7). 1. Press and hold down the detector s tamper switch. 2. Insert one of the two batteries into the detector while observing battery polarity. 3. Release the tamper switch within 4 seconds (the LED blinks 3 times every 5 seconds). 4. To re-pair the detector, follow the instructions in section 3.4. 3.7 Walk Testing Walk across the far end of coverage pattern in both directions. The LED should light for 2-3 seconds each time your motion is detected. Important! Instruct the user to walk test at least once a week to verify proper function of the detector. Note: Upon battery insertion or closing the cover (which results in closing the tamper switch) the LED flashes for 2 minutes and the detector goes into walk-test mode for 15 minutes. In walk-test mode the LED lights upon every motion detection. After 15 minutes the detector automatically enters normal mode in which the LED will not blink after detection. Figure 8 - Coverage Pattern Walk-Test TROUBLESHOOTING If you encounter one of the following problems with the MP-841, perform the suggested remedy: Problem Remedy Attempt to pair the sensor is unsuccessful. The sensor and the Touchscreen (panel) do not communicate. The sensor sends a Low Battery indication. Panel does not arm because of an unrecognized sensor malfunction Make sure that the sensor has been defaulted and is set to pairing mode (see section 3.4). Perform the signal strength testing procedure described in the control panel installation manual. Make sure that the signal is sufficient. If necessary, replace the sensor s battery. To ensure continuous proper operation, replace both batteries within two weeks of the first Low Battery indication. Consult with your installer or system provider before you disable a zone. Disable the sensor zone (see the control panel user manual). Note that disabling a sensor zone lowers the overall security level of your system. D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST 5

SPECIAL COMMENTS Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection, malicious masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures close to that of the human body and unexpected failure of a component part. The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance. An alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be prudent enough to continue insuring their lives and property, even though they are protected by an alarm system. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: Re-orient or re-locate the receiving antenna. Increase the distance between the device and the receiver. Connect the device to an outlet on a circuit different from the one that supplies power to the receiver. Consult the dealer or an experienced radio/tv technician. Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection, malicious masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures close to that of the human body and unexpected failure of a component part. COMPLIANCE WITH STANDARDS FCC This device complies with Part 15 of the FCC Rules and RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. To comply with FCC Section 1.1310 for human exposure to radio frequency electromagnetic fields and IC requirements, implement the following instruction: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. Europe (CE): EN 300328, EN 301489, EN 60950, EN 50130-4, EN 50131-1, The MP-840 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 USA: CFR 47 Part 15 Canada: RSS 210 EMAIL: info@visonic.com INTERNET: www.visonic.com VISONIC LTD. 2016 XHS1-TY / MP-841 FLAT PIR COMCAST D-306094 ( Rev. 0, 04/16) 6 D-306094 XHS1-TY / MP-841 FLAT PIR COMCAST