UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

Similar documents
UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)-

UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

1. Chemical Product and Company Identification

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Vibration tests on a TNAML Luminaire

Test Methods for Consideration Into Radio Standard

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

DP86 Constant Voltage with Fitting

ENVIRONMENTAL TEST REPORT

environmental chambers for Battery testing

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

JUL 18 Rev A1

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

/Mar/2014 Rev A

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Product Tests Report

Mar11 Rev C

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

USB 3.0 Plug & Receptacle

Mar11 Rev B

environmental chambers for Battery testing

Battery Design Considerations

PERMANENT DOCUMENT. Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

COMITÉ EUROPÉEN DES ASSURANCES

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Residual Current Devices

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

INTERNATIONAL STANDARD

Battery Design Considerations

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Products for Secondary Battery Market

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

M7100 Pressure Transducer

DRAFT TANZANIA STANDARD

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

KILOVAC K1K High-Voltage Contactor

Laser Collimated Beam Sensor

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

D5100 Industrial Differential Pressure Transducer

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

FOS WATER LOW FOG 3000

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

APR 17 Rev A

Osram OT 40 OT 60 OT 90 4DIMLT2 E LED Drivers Conformity check to Synergrid C4/10

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Vacuum suction nozzle OVEM-...-1P/1N

SENTINEL A - Fault Passage Indicator

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

EAE/EAES «HEPHEA 248» Product Technical Instructions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

INTERNATIONAL STANDARD

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

FIS30XXseries Gas sensor module SPECIFICATIONS

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Part 3 Troubleshooting

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Emergency Lighting Control Gear Combo Economy Version (2 in 1)

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

1 Appendix - Product Specifications

Environment Test Report

Products for Secondary Battery Production and Testing

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Table 1. Serie of Digital Room Thermostats.

Digital Heater Element Burnout Detector K8AC-H

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

D5100 Industrial Differential Pressure Transducer

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

Event Monitoring Device (EMD)

Technical Data Sheet Opto Interrupter ITR

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

The New Battery Safety Standard EN for LEV s. Stephan Scheuer TÜV Rheinland

Installation Instructions for W2H Series Signals

EVAPORATIVE AIR COOLER

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Qualification Test Report LC Duplex Adapter For LC Cutouts

ABB. Modular contactors. Contents

AUR300C. Advanced Ultraviolet Burner Controller

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Rules for Intruder Alarm Systems

SENTINEL D - Fault Passage Monitoring

Transcription:

문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1028 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1028 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample Image 2011. 10. 13

1. UN Transportation Regulation Test Test Test 1. Altitude Simulation Test 2. Thermal Test Test 3. Vibration Test 4. Shock Test 5. External Short Circuit Test 6. Impact Condition Storing at (low pressure)11.6kpa for 6hr at 20+/5 [75± 2,6hr 40±2,6hr,interval max. 30min] x 10cycle Storing at 20± 5 for 24h [7Hz 200Hz 7Hz, in 15min] x 12 times x 3 direction 1) sinusoidal waveform with a logarithmic sweep 2) 7Hz 18Hz (maintaining 1gn) app. 50Hz (until 8gn) 200Hz (maintaining 8gn), 1.6mm total excursion Half sine shock (peak acceleration : 150gn, pulse duration : 6msec) x 6 (± x, y, z) direction x 3 cycle 100mΩ ext. shortcircuit at 55± 2 1hr continue after returning at 55± 2 Φ=15.8mm bar, 9.1kg mass, 61± 2.5cm height s Measuring mass before/ after each test (If M>5g, less than 0.1%) Measuring voltage before/ after each test (more than 90%) No leakage, no venting, no disassembly, no rupture, no fire No disassembly, no rupture, no fire (after 6 hours) Temp. monitoring (max. 170 ) Test 7. Overcharge Current = Manufacturer s recommended max. continuous charge current X 2 Voltage 1.If charge voltage 18V, V (min.) = 2 x (max. charge voltage) or V (min.) = 22V. 2.If charge voltage > 18V, V (min.) = 1.2 x (max. charge voltage) No disassembly, no fire (after 7 days) Test 8. Forced Discharge Only for Cell, not battery. No disassembly, no fire (after 7 days) * Tests through T1T5 shall be conducted in sequence with the same battery. * We declare that the abovementioned test is the result of being checked according to UN Test (Manual of Test and Criteria ST/SG/AC.10/11/Rev.5) 1 / 6

2. Test Procedure Sample Sample Preparation Preparation Forced discharge test is required to cell level, not pack battery level. 4 ea 1 st cycle d 4 ea 50 th cycle d Test 1 Test 1 Altitude Altitude Simulation Simulation Test 2 Test 2 Thermal Test Thermal Test Test 3 Test 3 Vibration Vibration 10ea 1 st cycle 50% d For cylindrical cells, 5 test cells are required. Test 6 Test 6 Impact Impact Test Test 7 7 Overcharge Overcharge 4 ea 1 st cycle d 4 ea 50 th cycle d Test 8 Forced Discharge * 10ea 1 st cycle Discharged 10ea 50 th cycle Discharged Test 4 Test 4 Shock Shock Test 5 Test 5 Ext. Ext. Short Short Circuit Circuit Report Report 2 / 6

31. T1T4 Test Before Altitude (T1) Thermal (T2) Vibration (T3) Shock (T4) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) A. 1st cycle fully state 1 473.829 12.479 473.827 0.000 12.477 473.824 12.475 473.810 473.798 2 12.493 474.826 12.490 474.823 12.487 474.820 12.484 474.812 474.802 3 12.468 472.493 12.465 472.490 12.463 472.485 12.461 472.479 12.458 472.473 4 12.475 473.749 473.743 12.470 473.739 12.467 473.729 12.465 473.717 Ave. 12.480 473.724 12.477 473.721 12.474 473.717 473.708 12.469 473.698 B. 50th cycle fully state 9 12.391 473.854 12.388 473.839 12.281 473.824 99.14 12.276 473.813 99.96 12.258 473.799 99.85 10 12.399 472.875 12.372 472.866 99.78 12.264 472.861 99.13 12.261 472.847 12.236 472.841 99.80 11 12.385 473.768 12.378 473.757 99.94 12.268 473.748 99.11 12.257 473.736 99.91 12.239 473.725 99.85 12 12.388 472.670 12.381 472.662 99.94 12.265 472.658 99.06 12.246 472.646 99.85 12.230 472.631 99.87 Ave. 12.391 473.292 12.380 473.281 99.91 12.270 473.273 99.11 12.260 473.261 99.92 12.241 473.249 99.84 Measuring mass before/after each test (If M>5g, less than 0.1%) Measuring voltage before/after each test (more than 90%, only charged samples) No leakage, no venting, no disassembly, no rupture, no fire 3 / 6

32. T5/T7 Test EXT.Short Circuit (T5) EXT.Short Circuit (T5) (V) (V) A. 1st cycle fully state B. 50th cycle fully state 1 55.77 5 12.258 55.68 2 55.02 6 12.236 55.17 3 12.458 54.96 7 12.239 55.21 4 12.465 55.68 8 12.230 55.38 55.77 12.258 55.68 Test Condition 100mΩ ext. shortcircuit at 55±2 Temperature < 170 No disassembly, no rupture, no fire within 6 hours Over (T7) Over (T7) (V) (V) A. 1st cycle fully state B. 50th cycle fully state 9 12.419 25.01 13 12.372 25.23 10 12.429 25.09 14 12.392 25.39 11 12.449 24.82 15 12.383 25.62 12 12.429 25.83 16 12.372 24.87 12.449 25.83 12.392 25.62 Test Condition Max. Current : 4000 ma CC/CV 2Imax(8000mA) 22V cutoff 24Hr No disassembly, no fire within 7 day 4 / 6

33. T6 Test (ICR18650C2) Impact (T6) (V) A. 1st cycle 50% charge state 21 3.807 25.43 22 3.807 108.50 23 3.806 24.36 24 3.806 24.79 25 3.806 114.39 3.807 114.39 B. 50th cycle fully discharge state 26 3.351 24.83 27 3.362 46.43 28 3.387 49.26 29 3.369 49.90 30 3.353 47.55 3.387 49.90 Test Condition Φ=15.8mm bar, 9.1kg mass, 61±2.5cm height Temperature < 170 No disassembly, no rupture, no fire within 6 hours 5 / 6

4. Sample Image 6/6