Approved by: Document no.: EGT

Similar documents
TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

TECHNICAL MANUAL EXPLOSION PROOF MANUAL CALL POINT BCP 135. Scope: EXcite USER MANUAL BCP 135. Date: Page: Page 1 of 6.

TECHNICAL MANUAL EXPLOSION PROOF SOUNDER/ HORN & BEACON BHB 125/ BHB 150. Scope: EXcite USER MANUAL BHB 125 / BHB 150 Date: Page: Checked by: Rev.

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Technical Manual for the Alarm Pull Station PH1

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Technical Manual for the Horn DB1P UL DB1HP UL

standards: standards:

4) Intrinsic Safety Certification

Technical Manual for the Fire Alarm Call Point - SM87 PBL

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION MANUAL (ATEX / IECEx)

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Electrical Installations Design, Selection, Erection and Inspection

Technical Manual for the Strobe - SM87 HXB

Flameproof Manual Call Points

manual addendum DELPHI Ex

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

OPTIWAVE X500 Supplementary Instructions

INSTRUCTION MANUAL (ATEX)

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Beamex. Calibration White Paper. Calibration in hazardous areas

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Beamex Calibration White Paper. Calibration in hazardous areas

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

THE BELGIAN PIONEER IN GAS DETECTION

Flameproof Manual Call Points Series MCP

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Guide for hazardous areas

Earth-Rite II PLUS Static Earthing System

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Hazardous Area Zirconia Oxygen Systems

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

INSTRUCTION & SERVICE MANUAL

Certificate of Compliance

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Explosion Proof Manual Call Points Series MCP

OPTIBAR DP 7060 Supplementary Instructions

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Certificate of Compliance

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

E2S Datasheet v10a

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Survey of electrical equipment installed in hazardous areas on tankers

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Dual certification! Air handling units for potentially explosive atmospheres

Operating Instructions

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

DB5 Intrinsically Safe Sounder Type DB-5

Explosion-proof Immersion Heater Type D-8660

IECEx Certificate of Conformity

Limit Switch Box YT-870/875 SERIES

Certificate of Compliance

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

UL HAZARDOUS LOCATIONS SERVICES

BOBINE ANTIDEFLAGANTI (ATEX) ISTRUZIONI EXPLOSION PROOF COILS (ATEX) - INSTRUCTIONS

BC9700 series High Power LED Explosion Proof Light

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Intrinsically Safe Solutions

Ex LED light fittings

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Explosion Proof Combination Signal db (A) / 5 Joule

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

IECEx Certificate of Conformity

Centurion Guided Radar HAWK CGR SERIES

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

ATM Lighting sp. z o.o

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Transcription:

ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make alterations in line with technical advances and industry standards. WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no

ET Page 2 of 6 1.0 INTRODUCTION BCP/BPB-125 series Explosion-proof Manual Call Point / Push button is designed for use in according to Oil & as, Offshore Platform, Chemical, Petrochemical, Refinery and Marine Industries etc. Enclosure material is Stainless Steel. The design of two LED indicators (reen and/or Red) is unique. It is compatible with PLC, DCS and ESD system via 4-20 m output. It is ideal to be used as an explosion-proof Manual Call Point for Fire larm System with ddressable Module fixed. There are four different types of manual call point available the one with the red LED, green LED, both red and green LED and none. Insert before the one chosen by customer. With only red LED indicator- During normal operation, the red LED will not be on unless the glass is broken by the operator when the device fault or alarm status arises. With only green LED indicator During normal operation, the green LED will be on unless the glass is broken by the operator when the device fault or alarm status arises. With both red and green LED indicator - During normal operation, the reen LED is on. When device fault or alarm status arises, the reen LED will be cut off and Red LED will be on. No LED indicator 2.0 EXPLOSION-PROOF LBELIN ll products have a rating label, which carries the following important information: Product order no.: e.g. BCP125DLFBRD (Refer to the datasheet for product order selection) Input voltage: Code: T.amb TEX Marking: <30 Vdc/ 6 amp or <250 Vac/ 11amp Ex d IIC T6 b Ex tb IIIC T85 C -40 C to +70 C as roup and Category: II 2D CE Mark: Warning: DO NOT OPEN WHEN N EXPLOSIVE S TMOSPHERE IS PRESENT Finish product serial no. (Include date of construction) Note; exact information is given on the actual label, ref also example on page 1. WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no

ET Page 3 of 6 3.0 TYPE PPROVL STNDRD The BCP125/BPB 125 series products have been approved according the following standards: IEC/ EN 60079-0 eneral Requirements IEC/ EN 60079-1 Flameproof enclosure d IEC/ EN 60079-31 Dust atmosphere t 4.0 ZONES, SROUP, CTEORY ND TEMPERTURE CLSSIFICTION The CP/ PB 125 series products have been certified Ex d IIC T6. This means that the units can be installed in locations with the following conditions: rea Classification: Zone 1: Explosive gas air mixture likely to occur in normal operation. Zone 2: Explosive gas air mixture not likely to occur, and if it does, it will only exist for a short time. as roupings: Equipment Category: 2D roup II Propane roup IIB Ethylene roup IIC Hydrogen and cetylene EPL: b / Db Temperature Range: -40 C <Ta < 70 C 5.0 INSTLLTION eneral Requirement Selection, Installation, Maintenance and repair of electrical apparatus for use in potentially explosive atmosphere should be done in according to IEC/ EN 6079-14/ -17/ -19. Product installation must be carried out in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer. Location The location of the unit should be made with due regard to the area where the unit is visible and can be easily operated. The unit should only be fixed to services that can carry the weight of the unit. Mounting The product should be mounted on a vertical surface using four (4) fixing holes in the base. The fixing holes are designed to fit M5 llen Screw only. Use of stainless steel fastener is recommended by BRTEC TECHNOR. If you need mounting plate, please contact BRTEC TECHNOR to ask the installation drawing of the mounting plate. (See Fig 1) WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no

ET Page 4 of 6 Fig. 1 6.0 WIRIN eneral Requirement BRTEC TEHCNOR recommends that all cables and cores should be fully identified (suggest using cable from 2.0 to 2.5 mm²). Ensure that all nuts, bolts and screws are secured. Ensure that only the right and certified cable glands are used and earthed correctly. Ensure that only the right and certified stopping plugs are used to blank off unused gland entry points. In order to maintain the IP rating of the product, we recommend SS316L for this application. Cable Connection The cable connection is connected with the 8-hole terminal blocks marked T1-T8 located in the flameproof enclosure (See Fig 2). Cable connection should be carried out in accordance with relevant technical requirement. Remove End Cover Unscrew the four (4) M5 retained hex socket head screws. This will release the cover from the base and allow the cover to hang on the retaining wire strap. Before replacing the cover, check that the flameproof joints are clean and not damaged, the gasket is still retained in its groove. (See Fig 2) CUTION: Before removing the cover, ensure the power to the product is isolated. Remove the four pieces of M5 socket screws to open the cover. Twist the cover gently clockwise and anti-clockwise, whilst pulling away from the base, until it comes off. Replace the cover in similar way, but operate in reverse manner as above. Fig 2 WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no

ET Page 5 of 6 7.0 OPERTION There are two types of Manual Call Point available-with/without flap. The product is operated by breaking of the glass using a hammer supplied by the manufacturer. For the one with the flap just lift it up first before breaking the glass. (See Fig 3) Fig 3 Replacement of lass To replace the glass after operation of the unit, unscrew the nut which fixes the glass. Take out the glass and remove any broken fragments from the unit. Check and make sure the gasket is in the nut. Place a new glass into the unit and replace the nut. (See Fig 3) CUTION: The glass and any broken fragments should be removed carefully by wearing protective gloves to avoid any injury. 8.0 CBLE LND The BCP125 / BPB 125 series product has four (4) cable gland entries. Only cable glands approved for Ex d applications can be used, which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN 60079-14. SFETY WRNIN: If the BCP125 / BPB 125 is used at high ambient temperatures, i.e. over +40ºC, then the cable entry temperature may exceed +70ºC and therefore suitable heat resisting cable glands must be used, with a rated service temperature of at least 95ºC. If a high IP (Ingress Protection) rating is required, a suitable sealing washer must be fitted under the cable gland. When only one cable entry is used, the other one must be closed with an Ex d flameproof blanking plug, which must be suitably approved for the installation requirements. WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no

ET Page 6 of 6 9.0 END OF LINE MONITORIN n end of line monitoring diode or an end of line monitoring resistor can be connected across the 24V+ and 0 terminals. If an end of line monitoring resistor is used, it must have a maximum resistance value of 3k ohms and a minimum wattage of 0.5 Watts; or a minimum resistance value of 1.2k ohms and a maximum wattage of 2 Watts. 10.0 MINTENNCE During working life of the product, little or no maintenance is required. Stainless Steel is resistant to most of the acids, alkalis and chemicals. If abnormal or unusual environmental conditions occur due to accident etc., visual inspection is recommended. To avoid electrostatic charge build-up, only exterior of the product can be cleaned with a damp cloth. If spare parts are required, these can be supplied by BRTEC TECHNOR. If any failure occurs but not caused by human factor, the product can be returned to BRTEC TECHNOR for free repair or replacement during warranty period. 11.0 CONDITIONS FOR SFETY USE i. This apparatus is suitable to be used only in ambient temperature as stated below: ii. Other than product manufacturer, painting and surface finishing are not permitted by the third party. iii. When used in dusty atmosphere, flameproof cable entry devices or stopping plugs have to be selected and installed carefully in order to maintain the IP rating (IP66/67) of the product. Type BCP / BPB-125 mbient Temp. -40 to +70 C WEB: www.bartec-technor.no PHONE: +47 51 84 41 00 E-MIL: mail@bartec-technor.no