Indoor Air Quality Controller

Similar documents
Indoor Air Quality Controller

1943P01. Solar Impact Sensor. Sensor for acquiring the impact of solar radiation Output signal DC V 2-wire current output 4...

сайт: эл. почта: Use RAB11 RAB11.. For 2-pipe fan coils

сайт: эл. почта: Use RAB21 RAB21.. For two-pipe fan coils

AUTRONICA. Панели для систем голосового оповещения

user manual Non-invasive Ultrasonic Flow Monitor KATflow 10 M E

MANUAL Overflow sensor NVF-104/34-PF

Price list for production of Design Bureau "Fizelektronpribor"

Kolmeks. Каталог. Аксессуары. По вопросам продаж и поддержки обращайтесь:

Панели. Autroprime. Технические характеристики

Панели. AutroSafe 4. Технические характеристики

etron M100

Installation Handbook Autroprime Interactive Fire Detection System

PRODUCT CATALOGUE. Autronica Fire and Security AS Petrochemical, Oil & Gas.

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Room Air Quality Sensors

Room air quality sensors

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Room Temperature Controller

Room Temperature Controllers

Duct Air Quality Sensors

Room thermostat with 24-hour time switch and large LCD

Room thermostats with LCD RDD100..

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

RVL479. Heating Controller. for use with a partner unit

Room Temperature Controller

Room thermostat with Auto Timer, Option External Input

Flush-mounted room thermostat

Wireless room thermostat with LCD

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Semi flush-mount room thermostat

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, independent DHW

Wall-mounted room thermostat with LCD

Semi flush-mount room thermostats

No. Icon Name Function

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Use. For 2-pipe fan coils

Room thermostat with Auto Timer, Option External Input

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QPM21 Series Duct CO 2 and Air Quality Sensors

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room thermostat with independent DHW control

1592P01. for liquids in piping DN

Room thermostats with LCD for wall mounting

Room Temperature Controller

Preliminary Release. Room Temperature

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Flush-mounted room thermostats

Smart Thermostat RDS110

Room Temperature Controller with LCD

RVL481. Heating Controller. including d.h.w. heating

RAB21 RAB21.1. For two-pipe fan coils

QAW70. Room Unit. Building Technologies. for use with heating controllers

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Room Temperature Sensor

Heating Element. Building Technologies HVAC Products

Control solutions Biofloor

ACS-30-EU-EMDR- 10-MOD

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Room thermostat with Auto Timer, Option External Input

Electronic timeswitch

Two-Channel Gas Controller

UV Flame Supervision System

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Cooker Hood LA-72-CAN.

! WARNING. Before using product, read and understand instructions.

Room Temperature Sensors

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

GL-CO-RFG Channel Gas Leak Alarm System

Room Temperature Sensors

NXM2G Installation and Operating Manual

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

5KMT2115 W A_01_EN_v10.indd 1 3/20/17 3:24 PM

OH720, OP720, HI720, HI722

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Combustible Gas Detection and Control System

Self-learning Room Temperature Controller

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

User Manual. Tumble Dryer ZDC8202P

LAE10 LFE10. Use. Series 02

Fire Damper Interface (230V)

Lonworks Damper Interface Catalogue

Multifunction IAQ Monitor

RVL480. Heating Controller

Register your product and get support at. AC4076. User manual

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

RVP310. Heating Controller. Building Technologies HVAC Products

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Immersion Temperature Controller

Instructions for the fan motor control system, SILVER C

Transcription:

s Indoor Air Quality Controller QPA84 With integrated VOC (Volatile Organic Compounds) sensor Operating voltage AC 230 V, Two-position output (non-potential-free relay contact) Use In ventilation plant to optimize the indoor air quality and the consumption of energy by providing demand-controlled ventilation. The QAP84 indoor air quality controller has been designed for use in basic ventilation plant where there is a need to remove annoying odours from a room, depending on demand, primarily in rooms with greatly varying occupancy levels and / or odours, thereby optimizing the ventilation time and ensuring good air quality. The controller is used especially in applications where a fan or an air damper actuator is controlled either manually or by a time switch. Typical spaces and applications: Small restaurants, pubs, bistros Lounges Recreation spaces and smoking areas Kitchens Changing rooms and cloakrooms Controlled ventilation of living spaces Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249--31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 сайт: www.simteplo.nt-rt.ru эл. почта: spt@nt-rt.ru

Application examples Example with extract air fan Example with extract air damper QPA84 LQ 1571S01 QPA84 LQ 1571S02 Functions The integrated VOC sensor measures concentrations of odorous substances and gases, such as tabacco smoke, human body odours, kitchen odours, carbon monoxide, methane, ethanol, acetone, methanol, etc., in the room air. The concentrations measured by the sensor are compared with the setpoint. If the setpoint is exceeded, the fan or the air damper actuator will be switched on via control output Y1. When the air quality improves as a result of the ventilation or other influencing factors, the device connected to control output Y1 will be deactivated again. The QPA84 is supplied with a factory-set setpoint. As soon as the controller is connected to power, the self-adaptation algorithm ensures that the indoor air quality setpoint will be matched to the local supply air quality. The switching on / off behaviour of control output Y1 can be changed by means of a shorting plug: Position of Action shorting plug Very good air quality level, increased energy consumption 1) 1571Z01 1571Z02 1571Z03 Good air quality level, optimum energy consumption 1) (factory setting) Acceptable air quality level, minimum energy consumption 1) 1) Energy consumption resulting from heating or cooling and fan operation. Caution! To change the position of the shorting plug, the housing cover must be removed. This work must be carried out by an authorized electrician since there is a risk of touching mains carrying wires or parts. Ordering Product number Stock number Designation QPA84 BPZ:QPA84 Indoor air quality controller When ordering, please give name and type reference. Equipment combinations For indoor air quality control with extract air dampers: OpenAir TM two-position air damper actuators GCA32.. see data sheet N4613

Mechanical design The controller consists of three major parts: the mounting plate made of plastic, the housing which accommodates the sensor and the control electronics, and the housing cover which is also made of plastic. Using suitable screws, the mounting plate is secured to a commercially available recessed conduit box. The housing engages in the mounting plate and is then secured by means of two catches. After wiring, the housing cover is also secured with two catches. Sensor, connection and setting elements 1 L N N Y1 AIRQUALITY 1571Z04 2 3 1 Connection terminals 2 Shorting plug for changing the switching on / off behaviour of control output Y1. Plug positions: = acceptable air quality 0 = good air quality (factory setting) + = very good air quality 3 VOC sensing element Engineering notes Power supply to the QPA84 should not be interrupted during operation (e.g. by a manual switch or time switch program). If interrupted, the controller will lose the adapted indoor air quality setpoint (the optimum setpoint for the room). Caution! The QPA84 may not be used for safety-related gas measurements! The screw terminals are only suited for installation wires. Stranded wires are not permitted! A 10 A prefuse must be used in the power supply line (L) to the controller. The two terminals for the protective earth (interconnected inside the unit) are merely used for earthing a regulating unit of safety class I connected to output Y1 The maximum permissible switching current (I) at output Y1 must be observed. It is dependent on the ambient temperature (T) of the QPA84: I [A] 9 8 7 6 5 4 3 2 1 0 T 5 0 5 10 15 20 25 30 35 40 45 50 [ C] 1571D01 WARNING No internal line protection for supply lines to external consumers Risk of fire and injury due to short-circuits Adapt the line diameters as per local regulations to the rated value of the installed fuse.

Mounting notes Caution! Mounting location: in the room. The location where the controller is mounted should be representative of the indoor air quality level, e.g. on an open wall, 1.5 to 3 m above the floor. The controller should not be mounted in niches or bookshelves, not behind curtains, etc., or in locations where people are continuously present (within one to two meters), such as speaker s desks, working places, etc. The permissible environmental conditions must be observed. The controller is supplied complete with detailed mounting instructions. The controller must be installed by an authorized electrician. Commissioning notes The VOC sensing element requires about one minute to attain the right operating temperature. Control output Y1 can be activated by the electronics, depending on the mixed-gas concentration in the room. The proper functioning of the QPA84 can then be checked as follows: Hold a cloth or cotton-wool pad saturated with alcohol in front of the unit s ventilation slots, or Let gas from a cigarette lighter enter the ventilation slots Then, control output Y1 will be activated after a short period of time. Operating notes After about two days, the QPA84 will assume the setpoint that ensures optimum indoor air quality. This is accomplished by the setpoint adaptation algorithm. The algorithm adjusts the setpoint periodically. For this reason, the power supply to the controller should not be interrupted. The unit is maintenance-free. Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations.

Technical data Power supply Operating voltage AC 230 V +10 % 15 % Mains frequency 50 / 60 Hz ±4 % Power consumption 0.5 VA External supply line protection Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 Control output Y1 Breaking voltage non-potential-free switching contact AC 230 V Switching current 1) max. 8 A (res.) max. 6.8 A (ind.), cosϕ = 0.6 External supply line protection Refer to section Power Supply Terminals Connection terminals screw terminals for wires of 1 to 2.5 mm 2 Cable lengths L, N, PE, Y1 depending on the load and in compliance with local regulations Degree of protection Protection class III according to EN 60730-1 Protection degree of housing IP30 according to EN 60529 Environmental conditions Operation to IEC 60721-3-3 Climatic conditions class 3K5 Temperature 5 +50 C (non-condensing) Humidity <85 % r.h. Mechanical conditions class 3M2 Transport to IEC 60721-3-2 Climatic conditions class 2K3 Temperature 25 +65 C Humidity <95 % r.h. Mechanical conditions class 2M2 Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commerce, light-industrial and industrial environments EU Conformity (CE) CM2T1571xx 2) Dimensions Refer to "Dimensions Weight Incl. packing 0. kg 1) The maximum permissible switching current is dependent on the ambient temperature of the QPA84 (refer to "Engineering notes") Internal diagrams L 10 A 13 A L, N Operating voltage AC 230 V Protective earth connection for loads of safety class I Y1 Control output, demand for ventilation

Dimensions Dimensions in mm 48,2 101 96,4 39 30 30 30 30 86 Mounting plate 3,6 86 1571M01 Архангельск (8182)63-90-72 Астана +7(7172)727-132 Белгород (4722)40-23-64 Брянск (4832)59-03-52 Владивосток (423)249--31 Волгоград (844)278-03-48 Вологда (8172)26-41-59 Воронеж (473)204-51-73 Екатеринбург (343)384-55-89 Иваново (4932)77-34-06 Ижевск (3412)26-03-58 Казань (843)206-01-48 Калининград (4012)72-03-81 Калуга (4842)92-23-67 Кемерово (3842)65-04-62 Киров (8332)68-02-04 Краснодар (861)203-40-90 Красноярск (391)204-63-61 Курск (4712)77-13-04 Липецк (4742)52-20-81 Магнитогорск (3519)55-03-13 Москва (495)268-04-70 Мурманск (8152)59-64-93 Набережные Челны (8552)20-53-41 Нижний Новгород (831)429-08-12 Новокузнецк (3843)20-46-81 Новосибирск (383)227-86-73 Орел (4862)44-53-42 Оренбург (3532)37-68-04 Пенза (8412)22-31-16 Пермь (342)205-81-47 Ростов-на-Дону (863)308-18-15 Рязань (4912)46-61-64 Самара (846)206-03-16 Санкт-Петербург (812)309-46-40 Саратов (845)249-38-78 Смоленск (4812)29-41-54 Сочи (862)225-72-31 Ставрополь (8652)20-65-13 Тверь (4822)63-31-35 Томск (3822)98-41-53 Тула (4872)74-02-29 Тюмень (3452)66-21-18 Ульяновск (8422)24-23-59 Уфа (347)229-48-12 Челябинск (351)202-03-61 Череповец (8202)49-02-64 Ярославль (4852)69-52-93 сайт: www.simteplo.nt-rt.ru эл. почта: spt@nt-rt.ru