Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Similar documents
Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

RTD TEMPERATURE SENSING SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Remote Alarm Panels Features

Model 17A00 Expansion Enclosure

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Instruction Bulletin

DIESEL Engine Fire Pump Controllers Features

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

DE20 INSTRUCTION MANUAL

4 & 8-POINT ANNUNCIATORS Instruction Manual

Pioneer-R16 Gas Monitor Operator s Manual

Pump-Up Controller MODEL 4062

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

E340 BOILER CONTROL INSTALLATION MANUAL

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Soft Start Series MP700 Solid State, Reduced Voltage

JDDT1 - Single Stage Digital Thermostat

THERMAL MANAGEMENT SOLUTIONS

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Pump-Down Controller MODEL 4052

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Across-the-Line SERIES MP300 Combined Manual and Automatic

DT968C C.T. BATH CONTROLLER

Controllers. Instruction Manual WARNING

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

Transfer Switch Features

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

02/11/2015

02/11/2015

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Transfer Switch Features

THERMAL MANAGEMENT SOLUTIONS

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Instruction Manual WARNING

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

WARNING Important Safety Information

CHAPTER 20 SERVICE EQUIPMENT

tcu.z Commercial Programmable Thermostat Installation Instructions

T500 Elite MANUAL (Software Version 3.0.9)

Installation and Operation Manual

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Installation/Owner s Manual Models 1504 / 1506

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

/ Marley Collection Basin Heater / User Manual

Bimetal Disc Thermostat. Product Information and Application Notes

Fluid Cooler Fan and Pump control panel

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Variable Frequency Drive SERIES MP800 VFD

Table of Contents SECTION PAGE

FDF Foam Pump Controllers Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

INSTALLATION INSTRUCTIONS

Carbon Monoxide Transmitter

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Product Manual SZ1145

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

TECHNICAL DATA OBSOLETE

SECTION AUTOMATIC TRANSFER SWITCHES

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Marley Collection Basin Heater Circuit

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

DIGITAL LIGHT CONTROLLER

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Beacon 800 Gas Monitor Operator s Manual

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Autofire Express Ramp/Hold Controller Instruction Guide

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

Alarm Tone Generator Model AG17

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Installation Guide for models:

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Mark 25 Ultrapure Water Conductivity Analyzer

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Transcription:

Phone (724) 528-9559 Cimco Electronics, Inc. Fax (724) 528-1108 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 Oct., 2002 IMPORTANT NOTICE Dear Customer, We would like to make you aware of a few hardware modifications that have been made to our existing Model A21 instrument. These changes are 1. different fuse holders and 2. the use of a 120/240 volt selector switch. These hardware modifications do not alter the performance of our instrument; however, to avoid any possible confusion we have decided to create a new model number for the instruments with this new hardware. This instrument that you have received is now considered a C21. Please use this new model number when placing orders for this instrument. Thank you for your patience, and if you have any questions please feel free to contact our office through phone, fax, or email.

Phone (724) 528-9559 Cimco Electronics, Inc. Fax (724) 528-1108 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 INCOMING TEST INSTRUCTIONS SERIES 21 with Microprocessor Oct., 2002 Before conducting tests, read STANDARD INSTALLATION INSTRUCTIONS, IL 10-29-02. The following procedure is part of our complete certification test. You will receive a certified test report with each instrument. Your incoming inspection should include all steps. 1. CONNECT TO POWER AND SHORT THE SENSORS INPUTS. a. Functional tests can begin immediately. b. Instrument must have a warm-up period of 15 minutes before accuracy tests are conducted. 2. CHECK STATUS MODE OF ALL RELAYS WITH ENERGIZED The status must agree with the notations on the back-plate. 3. TEST TOTAL SYSTEM CONTROL a. bottom left button. Ambient temperature will be displayed and all LEDs will illuminate. b. PRESS AND RELEASE bottom right button to advance test mode. c. TEST MODE SEQUENCE is described on face-plate. Local alarm can be silenced if desire. Trip relay will not turn on. Trip relay turns on only with input signal. d. RELEASE bottom left button when test is complete. 4. TEST MAXIMUM TEMPERATURE MEMORY a. Connect thermocouple to one input, leaving others shorted. b. Press READ and note temperature indication. c. Press RESET. d. Apply heat to the thermocouple tip. e. Temperature will increase. f. Press READ. Memory will indicate maximum temperature indicated in step four. g. Press RESET. 5. CHECK ALL FRONT PANEL SWITCHES AND LIGHTS: Turn the instrument power off for a few seconds and turn the power on again, repeat as desired. Each of the switch controls will click as it is pressed. The following sequence will test all operator controls and status lights on the front panel. a. Test set-up and fan mode control: Short all temperature sensor inputs with a short piece of copper wire. Press the manila mode control and note the fans-on and manual mode indicator light. Press the automatic mode, note the automatic mode indicator light and retain this mode during the remainder of the following tests. b. For optional fan exerciser, the fan exerciser begins in the fans-on cycle. The decimal point located on the bottom right of the temperature indicates that the fan exerciser is energized. This decimal point, the fans on relay and fans on status LED will remain energized for one to two minutes. Continue the test after the fan exerciser has completed the fans on cycle. c. Follow system test instructions to check all remaining lights and relays (except trip relay). d. Follow Read Other Phases to verify phase lights. Each control will energize the appropriate LED next to the control switch. After the above checks are completed, all switches and status lights have been checked.

PHONE (724) 528-9559 FAX (724) 528-1108 Cimco Electronics, Inc. 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 SERIES 21 with Microprocessor STANDARD INSTRUCTIONS FACE-PLATE Power on light is green. Fans on light is amber (yellow). (Fail-Safe) Alarm on light is red. (Fail-Safe) Trip on light is red. DISPLAY CONTROLS MAXIMUM TEMPERATURE MEMORY (MTM) PRESS READ to display MTM since last reset. PRESS RESET to erase MTM. MTM is retained indefinitely with loss of power. READ OTHER S Instrument displays highest temperature input. Green LED indicates hottest phase. PRESS other buttons to read other phases. Control logic automatically shifts to indication. SYSTEM TEST bottom left button. PRESS AND RELEASE bottom right button to advance test mode. TEST MODE SEQUENCE is described on face-plate. Local alarm can be silenced if desired. Trip relay will not turn on. Trip relay turns on only with input signal. RELEASE bottom left button when test is complete. OPERATION CONTROLS FAN MADE CONTROL LED's indicate auto or manual control of fan power. START-UP condition is AUTO. PRESS MANUAL ON to energize fans for continuous running. PRESS AUTO to return to automatic mode. FAN EXERCISER (PROGRAMMABLE) will energize fans once per week. START-UP DEFINITION 1 At start-up, alarm and fan contacts are in the "on-state". 2 Alarm and fan contacts change to "off-state" when power is applied or, 3 Alarm and fan relays revert to"on-state" if thermocouple is open or, 4 Alarm and fan contacts revert to"on-state" if power lost. STANDARD INSTALLATION BACK-PLATE INPUT POWER CONNECT LAST TO T-11 & T-12 1. Determine input power voltage. 2. Make proper switch selection while following instructions on the back-plate. 3 The 0.25 amp fuse is to protect the instrument if 240 VAC is applied while the instrument is connected for 120 VAC power. FAN POWER-CONNECT THIS FIRST TWO OUTPUTS TOTAL 1 Fan power relays are Fail-Safe. 2 Fans one output power is T-1 and T-2. 3 Fans two output power is T-3 and T-4. 4 Each circuit rating if used alone is 15 amps, 1 HP at 120 VAC, 2 HP at 240 VAC 5 Total rating for both circuits together is 15 amps, 2 HP at 120 VAC, 4 HP at 240 VAC 6 Instrument is supplied with 20 amp fuse. Maximum fuse rating is 30 amps. TEMPERATURE SENSORS-CONNECT 2ND 1 Non-magnetic Type E thermocouple is standard. 2 Red Lead is always negative. 3 Cut thermocouples to length. 4 Strip insulation from metal leads. 5 Use clamp on terminal block to connect thermocouple to instrument. 6 Do not use crimp lugs. 7 Clamp leads firmly in place. SYSTEM GROUND 1 Instrument ground is isolated from system ground. 2 Connect system ground to T-10. TRIP AND RELAYS 1 Form C relays. 2 Connects are dry. 3 Alarm relay is Fail-Safe. Obtain permission from the transformer manufacturer before changing any programmable features. Contact Cimco for programming instructions. Visit Cimco's website at: www.cimcoelectronics.com IL 10-29-02-B

FEATURES REFERENCE DRAWING 10-21-96-A 10-21-96-B 10-21-96-C DETAILS 1. Loss of power to instrument 1. Alarm relay turns on. 2. Fan relays turn on. 3. Optional 5th set-point relay turns on. 2. Power supply brown-out 1. Power supply supervisor 2. Automatic re-start 3. Open temperature sensor 1. Alarm relay turns on. 2. Local alarm turns on. 3. Alarm-on status LED turns on. 4. Fan relays turn on. 5. Fan-on status LED turns on. 6. Digital display blinks. 7. Phase LED associated with open sensor blinks. 8. Press phase selector with blinking LED and digital display will indicate three zeroes. 9. Functional sensors continue with normal operation. (Trip relay can be turned on from operating sensors.) 4. Micro-controller failure 1. Alarm relay turns on. 2. Fan relays turn on. 3. Power-on LED stays on. 4. On set-points are limited to 1. Minimum set-point on is 50 C and 2. Maximum set-point on is 230 C. 5. EE Prom failure 1. EE Prom remembers user selected set-points. 2. If EE Prom fails, operating software will use: 1. 160 Degrees C for Fans-On 2. 180 Degrees C for Alarm-On 3. 210 Degrees C for Trip-On 4. 210 Degrees C for 4th Set-Point On (Option) 5. 160 Degrees C for 5th Set-Point On (Option) SPECIAL NOTE 7. Trip relay with open temperature sensor: 1. Open temp. sensor does not energize trip relay. 2. Trip relay will turn-on if one or both of the other phase sensors indicate temperatures above the trip set-point. TABLE 3 Fail-Safe Feature FIGURE 1 POWER ON FANS ON TRIP DISPLAY CONTROL MAXIMUM TEMP. MEMORY READ RESET, AND BUTTONS TO READ MATHEMATICAL AVERAGE TO OPERATE SYSTEM TEST OF THREE INPUTS. SYSTEM TEST CONTROLS TEST MODE SEQUENCE TEMPERATURE C AUTOMATICALLY DISPLAYS WITH HIGHEST TEMPERATURE. PRESS BUTTONS TO READ CURRENT TEMPERATURES. "READ" BUTTON THEN PRESS, OR BUTTON TO READ MAXIMUM TEMPERATURE MEMORIES OF OTHER S. LISTING & REFERENCES Details on TABLE 3 1. Initial start-up 2. Future start-ups 3. Reset software 4. Fan mode 5. Silence alarm 6. Access code 7. Dead-band limits 8. Fan exerciser limits 9. Monitor fans-on time 10. Monitor alarm-on time 11. Monitor trip-on time 12. Loss of power 13. Brown-out 14. Open temp. sensor 15. Micro-processor 16. Limits on set-points 17. EE Prom failure 18. Trip relay OPERATION CONTROL PRESS TO SILENCE 5. 4 TH SET-POINT ON - OPTION 6. 5 TH SET-POINT ON - OPTION 7. 5 TH SET-POINT OFF - OPTION 8. 4 TH SET-POINT OFF - OPTION FAN MODE CONTROL AUTO MANUAL ON LOCAL PRESS AND RELEASE TO ADVANCE TEST MODE 10. OFF 11. FAN OFF Drawing and Item 10-21-96-A 1 10-21-96-A 2 10-21-96-A 3 10-21-96-A 8.1 10-21-96-A 8.2 10-21-96-B 1 10-21-96-B Table 2.4 10-21-96-B Table 2.5 10-21-96-C Item 2 10-21-96-C Item 3 10-21-96-C Item 4 10-21-96-D Table 3.1 10-21-96-D Table 3.2 10-21-96-D Table 3.3 10-21-96-D Table 3.4 10-21-96-D Table 3.5 10-21-96-D Table 3.6 10-21-96-D Table 3.7 TABLE 4 SUB 1: 5-5-97; REMOVE FANS OFF CONTROL PANEL SCALE 1:2 DRAWING 10-29-02-C WEST MIDDLESEX, PA 16159

OPERATING INSTRUCTIONS for MONITORING FEATURES FIGURE 1 POWER ON FANS ON TRIP 1. First time (as shipped) start-up status 1. Fan mode is automatic. 2. Fan exerciser is off. 2. Future "start-up's" use customer's choice of programmed operations. 1. Reference Drawing 10-21-96-B. 2. Access code is required for all programmable features. 3. Reset or restart software (if instrument does not respond to commands) 1. Press and hold buttons 1, 6, & 9 in 1-6-9 simultaneously. 2. All lights except for "POWER ON" will turn off. 3. Release the three buttons. 4. Instrument software will reset to normal start-up mode. 5. Check instrument fuse if Power On status light is "OFF". 4. Display maximum temperature memory. 1. Press button 1. 2. Display will indicate highest temperature in memory. 3. Phase LED's will indicate which phase temperature is displayed. 5. Display maximum temperature memory (MTM) of other phases 1. Press and hold button 1. Then press 2. Button 3 to display MTM of left phase or 3. Button 4 to display MTM of center phase or 4. Button 5 to display MTM of right phase. 5. Buttons 4 and 5 to display MTM of optional 4th input. 6. Release button 1. 6. Erase maximum temperature memories. 1. Press button 2 to reset all MTM's to zero. 2. Maximum temperature memories include 1. All three phases and 2. Optional fourth temperature sensor. 7. Display current operating temperatures 1. Press button 3 or 4 or 5 to display current phase temperatures. 2. Press buttons 4 & 5 to display optional 4th input temperature. 3. Press and hold buttons 3, 4, & 5 to display mathematical average of the three phase temperatures. 8. Operation controls 1. Fan mode 1. Start-up is always in automatic mode. 2. Press button 7 for manual-on mode. 3. Press button 6 for automatic mode. 2. Alarm control 1. Press button 9 to silence local alarm. 2. Remote alarm relay remains "on" until alarm condition clears. 9. SYSTEM TEST (general description) (for start-up test or check set-points and relays) 1. Reference Table 1 for test mode sequence 2. Press and hold button 10 then (NOTE: User must hold button 10 until desired steps in TABLE 1 are complete.) 3. Press and release button 11 to advance TEST MODE one step. 10. SYSTEM TEST sequential actions of test mode are: 1. instrument ambient temperature is displayed and all other LED's turn on. 2. Fans-on set-point temperature is displayed. 1. Fans-on LED is turned on. 2. Fans relays are turned on. 3. Alarm-on set-point temperature is displayed. 1. Alarm-on LED is turned on. 2. Alarm relay is turned on. 3. Local alarm is turned on. 4. Local alarm can be silenced if desired. 4. Trip-on set-point temperature is displayed. 1. Trip-on LED is turned on. 2. Trip relay will not turn on. 3. Trip relay turns on only with input signal. SUB 2: 5-5-97; REMOVE FAN OFF SUB 1: 11-15-96; ART WORK DISPLAY CONTROL MAXIMUM TEMP. MEMORY READ 10. SYSTEM TEST CONTINUED 5. Fourth set-point on-temperature is displayed. (Display will indicate 180 if set-point is not activated.) 1. 100's decimal point is turned on. 2. Fourth set-point relay is turned on. 6. Fifth set-point on-temperature is displayed. (Display will indicate 180 if set-point is not activated.) 1. 10's decimal point is turned on. 2. Fifth set-point relay is turned on. 7. Fifth set-point off temperature is displayed. (Display will indicate 166 if set-point is not activated.) 1. 10's decimal point will blink. 2. Fifth set-point relay will turn off. 8. Fourth set-point off temperature is displayed. (Display will indicate 175 if set-point is not activated.) 1. 100's decimal point will blink. 2. Fourth set-point relay will turn off. 9. Trip-off set-point temperature is displayed and trip-on LED will blink. 10. Alarm-off set-point temperature is displayed. 1. Alarm-on LED will blink. 2. Alarm relay will turn off or 3. Local alarm will turn off if not previously silenced. 11. Fans-off set-point temperature is displayed. 1. Fans-on LED will blink. 2. Fan relays will turn off. CONTROL PANEL SCALE 1:2 DRAWING 10-29-02-D RESET, AND BUTTONS TO READ MATHEMATICAL AVERAGE TO OPERATE SYSTEM TEST OF THREE INPUTS. SYSTEM TEST CONTROLS TEST MODE SEQUENCE TEMPERATURE C AUTOMATICALLY DISPLAYS WITH HIGHEST TEMPERATURE. PRESS BUTTONS TO READ CURRENT TEMPERATURES. "READ" BUTTON THEN PRESS, OR BUTTON TO READ MAXIMUM TEMPERATURE MEMORIES OF OTHER S. OPERATION CONTROL PRESS TO SILENCE 5. 4 TH SET-POINT ON - OPTION 6. 5 TH SET-POINT ON - OPTION 7. 5 TH SET-POINT OFF - OPTION 8. 4 TH SET-POINT OFF - OPTION FAN MODE CONTROL AUTO MANUAL ON LOCAL PRESS AND RELEASE TO ADVANCE TEST MODE 10. OFF 11. FAN OFF STEP MODE 5. 4TH SET-POINT ON - 6. 5TH SET-POINT ON - 7. 5TH SET-POINT OFF - 8. 4TH SET-POINT OFF - 10. OFF 11. FAN OFF TABLE 1 WEST MIDDLESEX, PA 16150

FOURTH SET-POINT 19 20 21 PHONE (724) 528-9559 MADE IN U.S.A. FAX (724) 528-1108 www.cimcoelectronics.com MODEL NO. SERIAL NO. TRIP,, FOURTH SET-POINT, AND FIFTH SET-POINT MAXIMUM RELAY CONTACT RATINGS ARE: N.O. CONTACTS ARE 20 AMPS OR 2 HP AT 240 VAC. N.C. CONTACTS ARE 10 AMPS AT 240 VAC. AND FIFTH SET-POINT RELAYS AND FAN POWER RELAYS ARE. READ INSTRUCTION MANUALS CAREFULLY. 23 26 29 + - 24 + - 27 + - 30 THIS INSTRUM ENT USES: TYPE E THERMOCOUPLES ALWAYS CONNECT RED THERMOCOUPLE LEADS TO NEGATIV E TERMINALS. 100 OHM RTD's. USE TWO LEADS AND CONNECT TO + AND -- TERMINALS. CAUTION DO NOT INCLUDE TERMINALS 23 TO 39 IN HI-POT TESTS CONTACT CIMCO FOR INSTRUCTIONS ON ALL FEATURES. 34 OUTPUT FOR REMOTE COMMUNICATIONS 35 RELAY NOTATION REFERS TO ENERGIZED CONDITIONS. FAN POWER AND AND FIFTH SET-POINT RELAYS ARE. READ INSTRUCTION MANUALS. FAN EXERCISER CAUTION THIS CONTAINS A USER SELECTABLE FAN EXERCISER. FAN POWER MAY BE TURNED ON AUTOMATICALLY EVERY 7 DAYS. FOLLOW OPERATING INSTRUCTIONS TO TURN THE EXERCISER ON OR OFF. TO PREVENT ACCIDENTAL CONTACT WITH FAN POWER VOLTAGE ON TERMINALS 1 & 3, REMOVE THE FAN FUSE ON THIS PANEL DURING ALL BENCH TESTS AND FAN MAINTENANCE. NOTE: FAN RELAYS ARE. FANS-ONE USES T1 AND T2. MAXIMUM HORSEPOWER IS 1 HP AT 120 VAC OR 2 HP AT 240 VAC. FANS-TWO USES T3 AND T4. MAXIMUM HORSEPOWER IS 1 HP AT 120 VAC OR 2 HP AT 240 VAC. EACH FAN RELAY CONTACT RATING IS 30 AMPS RESISTIVE. POWER SUPPLY 1/4 AMP MAX. AC 30 AMP MAX. AC INST. FUSE FAN FUSE SYSTEM GROUND 10 TRIP 9 8 7 6 5 5A 18 17 16 FIFTH SET-POINT CAUTION 1. MAKE ALL EXTERNAL CONNECTIONS BEFORE APPLYING POWER TO. 2. MAKE 120/240 VOLTAGE SELECTION ON SWITCH BELOW. 3. APPLY POWER TO TERMINALS 11 AND 12. 11 12 120 VAC 240 VAC 15.25" 9" 6.5" X 11.5" X 2.5" 1.75" BOX POSITION ON FACE-PLATE BOX IS 2.5" DEEP WEIGHT APPROX. 5.0 LBS CAUTION 1. S USE MICRO-CONTROLLERS FOR SIGNAL PROCESSING AND LOGIC CONTROL. 2. S THEREFORE MUST BE SHIELDED FROM MAGNETIC FIELDS GENERATED BY TRANSFORMERS. 3. S ARE SHIPPED FROM CIMCO INSTALLED IN A CARBON STEEL ENCLOSURE WHICH IS ADEQUATE SHIELDING IN "STANDARD" POWER AND SUBSTATION INSTALLATIONS. 4. CALL CIMCO FOR ADVICE ON NON-STANDARD INSTALLATIONS WITH ABNORMAL MAGNETIC OR ELECTRIC FIELDS. 6. ALWAYS CONNECT SYSTEM GROUND TO TERMINAL 10. 36 OUTPUT FOR REMOTE 37 COMMUNICATIONS FAN POWER CONTACTS 1 2 3 4 FANS 1 FANS 2 RTD'S AND THERMISTORS ARE TEMPERATURE SENSORS 38 OUTPUT FOR REMOTE COMMUNICATIONS 39 BACK-BOX SIZE 6.5" X 11.5" X 3" SUB 2. Area Code 5-21-98 SUB 1. T-12 & USA-NOTE: 5-5-97 CONNECTIONS NOT TO SCALE DRAWING 10-29-02-F WEST MIDDLESEX, PA 16159

REFERENCE NOTES 1. UL RECOGNIZED AND CROSS LISTED BY UL FOR CANADA (CSA) SERIES 21 POWER ON FANS ON TRIP DISPLAY CONTROL MAXIMUM TEMP. MEMORY READ RESET TO OPERATE SYSTEM TEST TEMPERATURE C AUTOMATICALLY DISPLAYS WITH HIGHEST TEMPERATURE. PRESS BUTTONS TO READ CURRENT TEMPERATURES. "READ" BUTTON THEN PRESS, OR BUTTON TO READ MAXIMUM TEMPERATURE MEMORIES OF OTHER S., AND BUTTONS TO READ MATHEMATICAL AVERAGE OF THREE INPUTS. SYSTEM TEST CONTROLS TEST MODE SEQUENCE OPERATION CONTROL PRESS TO SILENCE 5. 4 TH SET-POINT ON - OPTION 6. 5 TH SET-POINT ON - OPTION 7. 5 TH SET-POINT OFF - OPTION 8. 4 TH SET-POINT OFF - OPTION FAN MODE CONTROL AUTO MANUAL ON LOCAL PRESS AND RELEASE TO ADVANCE TEST MODE 10. OFF 11. FAN OFF THIS DRAWING IS SHOWN WITH BLACK LINES ON WHITE FOR COPY AND FAX CONVENIENCE. ACTUAL CONTROL PANEL IS BLACK WITH WHITE LETTERS AND LINES. 2. OPERATING INSTRUCTIONS USE DRAWINGS 10-21-96 10-21-96-A 10-21-96-B 10-21-96-C 10-21-96-D 3. INSTALLATION AND CONNECTION INSTRUCTIONS ARE INCLUDED WITH EACH. USE DRAWING 2-26-97-A. 4. CONTACT CIMCO FOR COMPLETE LITERATURE AND DETAILED DRAWINGS. 5. FACE-PLATE IS BLACK WITH WHITE LETTERS AND LINES. THIS DRAWING IS SHOWN WITH BLACK LINES ON WHITE FOR COPY CONVENIENCE. 6. OSHA LABEL IS INCLUDED IN THE OVERLAY AND IS OSHA STANDARD RED, BLACK AND WHITE. 7. REFERENCE DRAWING 2-26-97-A FOR MAGNETIC FIELD SHIELDING INSTRUCTIONS. OSHA WARNING LABEL PANEL SIZE = 9" X 15.25" MOUNTING HOLES ON 8" X 14.15" S OVERLAY IS BLACK LEXAN WITH WHITE LETTERS AND TRIP LINES. PANEL IS STEEL; PRIMES, BLACK 0.04" THICK SUB 1: Area Code 5-21-98 FACE-PLATE SCALE 1:2 DRAWING 10-29-02-E WEST MIDDLESEX, PA 16159