Superior Spa with Aqua-Aire

Similar documents
Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

Cascade Elite Transfer Lift System Safe Operation, Daily Maintenance Instructions, & Parts Breakdown

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

1-866-PENNERS

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

GULFSTREAM PLASTICS LTD.

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

K Specifications. Max. Water Volume

Installation and Operation Manual MG-304. Please read this manual carefully before use.

WALK IN BATH TUB OWNER S MANUAL

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

Operations and Safety Manual

TR 900. Height Adjustable Bathtub. Operating Manual. Hygiene Equipment Designed for People Hygiene Equipment Designed for People.

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

Model K 240 plus Part No

PIPELESS WHIRLPOOL FOOT BATH OWNER S MANUAL. Model: FB2-S115

K Specifications. Max. Water Volume

Integrity Bath. Operating Instructions and Training Checklist. Important Safety Instructions Read & Follow All Instructions Thoroughly

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

P200E Shuttle Brewer

Water Boilers ME10EN, ME15EN. Table of Contents

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

User s Manual Warm N Cozy

DUOBATHE BATHING SYSTEM

Assembly instructions. Alexandria Pedicare System ALEXANDRIA. Perfect design. Personal service.

Instruction Manual. Cheese Warmer with Pump

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

MODEL 7000 SUCTION UNIT

Avenue (HY) Series Installation & Operation Manual

Integrity Bath. Installation Manual. Important Safety Instructions Read & Follow All Instructions Thoroughly

EZ Way, Inc. BATHING CATALOG. PO Box 89, 710 E. Main Clarinda, IA

KAFKA BASIN K K K K K [180] 5.9 [158.7] 7.1 [180] 6.3 [159.7] 12.1[307.1] Ø2 [50] 5.9[148.7] 12.8 [325.

Plumbing System. Important Information. Shut-Off Valves

Recommended Floor Care Procedures

OPERATION MANUAL ALPHA ALS WET / DRY IMPORTANT SAFETY INSTRUCTIONS. Read all instructions before using or servicing machine.

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

User Manual. Countertop Tortilla/Portion Steamer. Models: QuickShot QS /2018. Please read and keep these instructions. Indoor use only.

Product Code: AP816. User Manual. T: F: Page 1 of 6

HA SERIES. CVap Holding Cabinet Owner s Manual

Earn Reward Points register your new

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Hoshizaki America, Inc.

Home Medical Equipment Oxygen

RHAPSODY. Recumbent bathing system. with people in mind

American Heavy Duty Laundry Products. Installation and user guide for use in the U.K. American Collection

Dietary Department, Infection Control

MANUAL OWNER S. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE.

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

MERIDIAN MODEL# 3793

CADDY 5 UL OPERATOR S MANUAL

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

PROFITEER POPCORN MACHINE OPERATION MANUAL

20-GALLON PARTS WASHER OWNER S MANUAL

INSTRUCTIONS FOR OPERATION AND CARE OF

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

OWNER S MANUAL ADVENTURER SERIES. Electric Grill A10-603E

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

K 3.97 M. Specifications or visit our website: In USA call: Part No

American Heavy Duty Laundry Products. Installation and user guide for use in the U.K. Collection

Merry Maids # 372/373/458/946/947. New Employee Training Day 4 Script

SureBlend. SureBlend. dilution control program

Electric Fireplace Insert with Heater

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

sanctuary walk-in bathtubs PROUDLY BROUGHT TO YOU BY

Model K205 M Plus Part No

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

OPERATOR S MODEL HCN-5 HHC-136 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

Table of Contents. English

customer care number 50 W. Big Beaver Road, Suite 350 Troy, Michigan USA (248) rainbowsystem.

INSTRUCTION MANUAL PRODUCT VIEW

REFRIGERATED CONDIMENT RAIL

Model K 520 M Part No

Fudge Server. Fudge Server with Pump. Thank You MODEL: FS MODEL: FSP

STORAGE AND DISPOSAL PESTS CONTROLLED BY TEMPO SC ULTRA PREMISE SPRAY* OUTDOOR PEST CONTROL CONTROL OF WOOD INFESTING PESTS

For routine maintenance of polished granite installations with a cleaner and protector:

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

Model K 280 M Part No

Hot Water Dispensers HWD2, HWD3, HWD5. Table of Contents

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

User Manual. Product Code: SJPFB002. p: f: Page 1 of 11 PRODUCT #: SJPFB002

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

Instructions for use Multibath

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

INSTRUCTIONS FOR OPERATION AND CARE OF

Cavitator Ultrasonic Cleaner Instruction Manual

Get Cleaning... What s your Vax s model number? User Guide. Multifunction SpinScrub. vax.com.au. Vax Careline: AU: NZ:

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Cleaning and Sanitation Procedures Module Cafe/Dining Restroom

Transcription:

Superior Spa with Aqua-Aire Safe Operation & Daily Maintenance Instructions PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 350750 Rev H 08/28/2014 1-866-PENNERS 1-866-736-6377 1-800-732-0717 E-mail Address: pennersales@hamilton.net Web Site: www.pennercareinc.com

Table of Contents Introduction... 3 Symbols and Terms... 3 CAUTION... 3 Left or Right... 3 Tub Technical Description... 3 Basic Components... 5 Transfer Technical Description... 5 Superior Tub... 6 System Preparation (Before Bath)... 7 Bathing Procedure... 9 System Cleaning (After Every Bath)... 13 Daily Maintenance... 15 Daily Safety Checklist... 16 Superior Tub... 16 Penner Transfer... 17

Introduction The Superior Spa with Aqua Aire is designed to significantly improve the efficiency and environmental safety of your nursing care operation. However, the benefits designed into the Sit-Bath System will be realized only if the system is operated and cared for properly. The purpose of this manual is to provide you with a recommended procedure to help you obtain the maximum efficiency and safety from your Sit-Bath System. Symbols and Terms The warning symbol identifies important safety messages. Failure to obey a safety warning may result in injury to you or to others. CAUTION The caution heading identifies important maintenance and operation information. Failure to obey a caution warning may result in damage to the Sit-Bath equipment and may void the warranty. Left or Right When the terms left or right are used with reference to the tub, this means left or right as you look at the control panel from the seat end of the tub. Tub Technical Description The Superior Spa is an Aqua-Air (air bubbling) bathing system intended for use in nursing homes, hospitals, and assisted living facilities to bath residents under the direct supervision of trained staff. The tub is constructed mainly of gel-coated fiberglass laminate. The tub has an Aqua-Air system to agitate the water with air bubbles. The tub also has a dispensing system to dispense shampoo/body wash and bath oil, and a disinfecting system to aid in cleaning the tub. The tub has four locking access doors for service and storage dispensed liquids and disinfecting concentrate. A thermostatic mixing valve controls incoming water temperature. Digital temperature readouts indicate all incoming and tub water temperatures. A hand shower sprayer is also provided.

Manufacturer: Tub Models: Penner Manufacturing Inc 102 Grant St / PO Box 503 Aurora, NE 68818 (402) 694-5003 Superior - 6300 Sit Bath Model # 350010-1 (White with Aqua-Air) Model # 350010-X (Color with Aqua-Air) Model # 350010-1SB (White with Still Bath) Model # 350010-XSB (Color with Still Bath) Tub Ratings: 120 Volts AC Aqua-Air: 13.3 Amps 60 Hz 1 Phase Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxid e. 61LN MEDICAL EQUIPMENT WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL2601-1, AND CAN/CSA C22.2 NO. 601.1 All temperature read-out values are accurate to +/- 2ºF (per NSF C-2). The read-out range is -50/250ºF. Resolution is 1ºF. An electrical circuit diagram can be found on the inside of the lid of the electrical box located inside the larger service access door on the left side of the tub. Service parts and technical information are available by contacting your distributor or by calling one of the telephone numbers located on the front or back cover of this manual. Environmental conditions for transport and storage for up to 15 weeks (as packaged from the manufacturer) are as follows: Temperature range 50º F (10º C) to 250º F (121º C) Relative Humidity 10% to 90% Atmospheric Pressure 7.5 PSI to 15.5 PSI

Basic Components The Superior Spa with Aqua Aire is composed of the following components: Superior Tub Penner Transfer Transfer Technical Description The Superior Transfer/Lift System is used with Aqua-Aire (air bubbling) bathing system intended for use in nursing homes, hospitals, and assisted living facilities to transfer or lift patients under the direct supervision of trained staff. The Transfer has two locking casters o n the rear (or end with pillar). Models are equipped with Scale. All Transfers have Swing-away and removable arms. All have a removable open concept seat pad that locks into position during use. Refer to the applicable Transfer Safe Operation and Daily Maintenance manual. Superior Transfer Models: Model # 384000-1 Transfer Electric Superior Right entry Model # 385000-1 Transfer Electric Superior Left entry Model # 386000-1 Transfer Electric Superior End entry Model # 387000-1 Transfer Electric Superior Right entry with Scale Model # 388000-1 Transfer Electric Superior Left entry with Scale Model # 389000-1 Transfer Electric Superior End entry with Scale

Superior Tub The Superior Tub is a specialized tub with built-in air jets, designed to help bathe your patients automatically. The tub has a built-in control panel, which provides controls for all the functions of the tub, as shown below. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1. Disinfect Button 2. Rinse Button (On tubs with Aqua-Air only) 3. Filling Spout 4. Fill / Shower Water-Temperature Readout 5. Tub Fill OFF Button 6. Tub Fill ON button (The unit has an adjustable time automatic shut-off.) 7. Temperature Control Knob 8. Tub Water-Temperature Readout 9. Aqua-Air ON / OFF Button 10. Shower ON / Auto OFF Button (The unit has an adjustable time automatic shut-off.) 11. Bath Oil Pump Plunger 12. Hand-Held Shower Sprayer 13. Shampoo Pump Plunger 14. Shampoo Dispensing Spout 15. Bath Oil Dispensing Spout 16. Drain Plug Cable

System Preparation (Before Bath) Only personnel who have been thoroughly trained in the operation of the Superior Sit-Bath System 6300 should operate this equipment. Operation of this equipment by untrained personnel could result in injury to the operator or patient. Your Penner Patient Care distributor is available at your request to provide complete in-service training on the equipment s proper operation. Prior to the bath, perform the following preparation steps: Note. Check the level of bath oil, shampoo, and disinfectant concentrate in the supply bottles daily to ensure that adequate amounts are available for the day s bathing requirements. These bottles are located behind the small access door on the right side of the tub. Replace a bottle before it runs out to avoid re-priming the system. 1. Place the drain plug in the drain. 2. Press the Tub Fill Button #6 to begin filling the tub. 3. Monitor the water temperature by watching the Fill / Shower Water- Temperature Readout. Adjust the water temperature by turning the Temperature Control Knob #7 to a normal bathing temperature, 95 to 105 degrees Fahrenheit.

In addition to monitoring the temperature readout, always check the water temperature by allowing it to run over your wrist. Failure to do this could result in a hot-water burn to the resident. 4. Fill the tub to approximately 5 inches below the overflow plate. This will normally result in the water rising to an appropriate level as the resident is lowered into the bath. 5. When filled, press the TUB FILL OFF button (#5) to stop the water flow. Note: The tub is equipped with a fill timer that can be set to stop the water flow after a specified time period. (This time setting should only be adjusted by maintenance personnel referencing the instructions in the Spare Parts Manual.) If water flow stops before the tub is filled to the desired level, simply press the TUB FILL - ON-AUTO-OFF button (#6). This re-starts the timer. 6. Make sure you have your entire bathing aids ready such as a washcloth and towels. The tub should be filled prior to placing the patient in the tub with the Tub Water-Temperature Readout registering between 95 and 105 degrees Fahrenheit. Additionally, the water temperature should be hand-tested before placing the resident in the tub. The tub should never be filled while a patient is in it. Failure to take these precautions could result in a burn injury to the patient. Before placing the resident in the tub, make sure that the seat bottom will clear the tub rim by at least two inches. Failure to follow this precaution could result in an injury to the resident.

7. Gently pull the resident towards the tub. Carefully lift the resident s legs over the side of the tub and position the resident to face the service deck of the tub. Press the down button to lower the resident into the water. Gently guide the patient s legs into the foot well at the bottom of the tub. Bathing Procedure You are now ready to begin washing the resident. The suggested bathing time is 5 to 10 minutes. Bathing a patient more than 10 minutes is not required. To bathe the resident, use the following procedures: 1. Start the Aqua-Air by pressing the Aqua-Aire on/off Button #9. 2. Push the Bath Oil Pump Plunger #11 to add Penner s Bath Oil to the water. The amount of bath oil will vary according to the resident s skin condition. (One push of the Bath oil pump plunger will dispense approximately 1 oz of bath oil.) Note. Penner Bath Oil is non-aqueous, liquid bathing oil containing refined lanolin similar to natural skin oil. When combined with water, Penner Bath Oil can penetrate the skin. This combination of water and oil restores moisture to the patient s skin and benefits the nursing attendant, whose hands are frequently in water as well. Additionally, the use of Penner Shampoo & Body Wash eliminates the risk of crosscontamination, which can result from sharing a single bar of soap. Penner Shampoo & Body Wash works with the bubble aeration of the system to clean and condition the skin.

In the following bathing instructions you are required to rinse the resident with the shower sprayer. Before doing so each time, make sure the temperature is between 95 and 105 degrees Fahrenheit by viewing the temperature readout. As a further precaution, always test the water on the inside of your wrist before turning the shower sprayer toward the resident. Failure to follow the precautions in this warning could result in a burn injury to the operator or the resident. 3. Bathe the resident s upper body as follows: a) Push the Bath Shampoo & Body Wash Pump Plunger #13 and dispense (from shampoo dispensing spout #14) into your hand or into a washcloth. Then apply the Penner Shampoo & Body Wash directly to the resident s body. b) Begin gently washing the resident s upper body. Pay special attention to folds or creases in the skin and under the arms. If the scalp is flaky, apply a small amount of Penner Bath Oil to the problem area and let it soak in until time for shampoo.

4. Rinse the upper body with the shower sprayer as follows. a) Pick up the Hand-Held Shower Sprayer #12 located on the right side of the control panel. b) Press the Shower Button #10 to activate the Shower Sprayer. Note. Once the shower sprayer is activated, it will stay activated for a period of time and then automatically shut off. This time period (up to 10 minutes) is adjustable by maintenance personnel only. c) While pointing the sprayer into the tub, not onto the resident, press the shower sprayer trigger. d) Adjust the water temperature by turning the Temperature Control Knob #6 to the normal bathing range of 95 to 105 degrees Fahrenheit as shown below. Monitor the temperature by viewing the Fill/Shower Temperature Readout #4. As a further precaution, always test the water on the inside of your wrist before turning the sprayer toward the resident. e) Repeat the washing and rinsing steps for the upper body a second time. 5. Bathe the resident s perineal area as follows:

a) Lift the resident s right leg and let the Aqua-Air bubbling action wash the perineal area. This technique protects the resident s dignity and removes any residual waste or fecal matter. Or, for extremely obese residents, you may wish to use the following procedure: a) Raise the seat to just above the water line and wash the area gently with a washcloth. b) Lower the resident back into the water. c) Lift the resident s right leg and turn the perineal area toward the action of the Aqua-Air bubbles, rinse the area. 6. The resident s feet will be cleaned by the Aqua-Air bubbling action at the bottom of the tub. For extremely soiled feet, use the following procedure: a) Adjust the seat until the resident s feet are in the action of the jets b) Hold the feet in the jet action for 30 to 60 seconds. 7. To shampoo the resident s hair, use the following procedure: a) Wet the resident s hair with the shower sprayer. b) Push the Shampoo Pump Plunger #13 and apply a small amount of Penner Shampoo to the wet hair.

Note. Penner Shampoo & Body Wash is a special formula with lanolin for use with residents who have dry scalp and/or skin conditions. Penner Shampoo special conditioning formula assures that all residues will be removed quickly and easily, leaving hair clean, conditioned, and shining. c) Massage the resident s head to create a lather. Continue the massage to fully clean the hair and scalp. d) Rinse with the shower sprayer. e) Shampoo and rinse a second time if required. System Cleaning (After Every Bath) Clean and disinfect the tub after every bath with Penner Cleaner/Disinfectant as follows: Note. Penner Cleaner/Disinfectant is a special non-abrasive cleaning and disinfecting solution that will not harm the tub s fiberglass surface. Penner Cleaner/Disinfectant is the only cleaning solution designed and recommended for use with your Superior Tub. CAUTION Some cleaners, disinfectants, and floor strippers contain ingredients that are corrosive or abrasive. These solutions or compounds may contain chlorine, acid, basic ingredients or abrasives. DO NOT allow such solutions or compounds to come in contact with your Penner equipment. Failure to heed this caution could result in damage to the equipment and void the warranty. 1. Drain the water from the tub. 2. Press the Shower Button and rinse the inside surfaces with the shower sprayer.

3. Close the drain. 4. Press and hold the Disinfect Button #1 located on the left side of the tub. As the button is held down, the properly mixed cleaning solution is running through the air injection system and out all of the air jets. Release the button after you see solution coming out of all the air jets and you have 1 to 1 1/2 gallons of disinfectant solution in the foot well of the tub Housekeeping personnel should wear protective glasses and gloves to prevent disinfectant from damaging their eyes or skin. If disinfectant gets on the skin or in the eyes, rinse thoroughly with plenty of water. Seek medical advice if irritation occurs. 5. Use a long-handled brush (available from your Penner distributor) to thoroughly scrub all interior surfaces of the tub with the solution that remains in the foot well of the tub. 6. Disinfect the Penner Transfer by positioning it over the tub. Use the brush to scrub its surfaces with the remaining solution. Allow for proper disinfectant contact time (Usually 10 minutes or as recommended by the disinfectant s manufacturer) and rinse the seat. Replace the seat on the Penner Transfer. 7. Remove the plug from the drain. 8. Rinse the tub s interior surfaces thoroughly with the shower sprayer.

9. Spray water from the shower sprayer to rinse out most of the disinfecting solution. Then press and hold the rinse button (#2) until you see clear water (not soapy) coming out of the air jets. Release the rinse button. 10. Finish rinsing the interior surfaces of the tub with the shower sprayer. 11. Start the air blower by pushing the Aqua-Air Button #7. Allow it to run for 30 seconds. This pushes the rinse water out of the air injection system. If this was the last bath of the day, allow the blower to run for 2 minutes to dry out the system. 12. Stop the air blower by again pushing the Aqua-Air button #7. Daily Maintenance To properly maintain the Superior Spa System, perform the following daily maintenance procedures. 1. Check that there is an adequate supply of system liquids such as shampoo, bath oil, and disinfectant concentrate in the supply bottles located behind the small access door on the right hand side on Aqua-Air tubs. Replace the bottles before they are empty to avoid re-priming the system. Be sure each bottle label matches the label found on the hose to which the bottle is attached. While replacing system liquids, housekeeping personnel should wear protective glasses and gloves to prevent disinfectant concentrate from damaging their eyes or skin. If disinfectant gets on the skin or in the eyes, rinse thoroughly with plenty of water. Seek medical advice if irritation occurs. 2. Perform the Daily Safety Checklist described in the following section before using the system.

Failure to perform the daily safety checks and take corrective action, when required, prior to the operation of the equipment each day could result in injury to the resident or operator. If any part of the system is not functioning properly, cease all bathing activities until the problem is corrected by maintenance. The system must be maintained on a scheduled basis to ensure it is functioning properly. Failure to heed these precautions could result in injury to the operator or resident. Daily Safety Checklist CHECK THE FOLLOWING ITEMS EACH DAY BEFORE USING YOUR SUPERIOR SIT-BATH SYSTEM. Superior Tub Perform the following safety checks for the Superior Tub: 1. High temperature limit Press the Fill Button and turn the Temperature Control Knob all the way to the left to the highest setting. Test the fill and shower water temperature to ensure that it reaches no more than 115 degrees Fahrenheit (lower if required by local regulations). 2. Temperature Read-Out Accuracy Press the Fill Button and adjust the temperature of the water to the normal bathing range of 95 to 105 degrees Fahrenheit. Test the temperature of the water with a thermometer and by letting the water flow over your wrist. The water temperature should be consistent with the thermometer reading and should not feel too hot or too cold.

Penner Transfer Perform the following safety checks for the Penner Transfer: 1. Seat Belt Check the condition of the seat belt(s) for signs of excessive wear. Also, check the fastening hardware and D rings to insure these parts are secure and not missing. If during the safety checks you find parts are missing, are excessively worn, do not function properly, do not operate the equipment until the maintenance department has taken the appropriate corrective action. Your Penner Distributor and his personnel are trained to provide inservice instruction and maintenance on your Superior Spa. If you have any questions about the operation or maintenance of your Sit-Bath System, please contact your Penner Distributor.

For your nearest distributor, contact: PENNER PATIENT CARE, INC. Box 523 / 102 Grant St. Aurora, NE 68818 1-866-PENNERS 1-866-736-6377 1-800-732-0717 E-mail Address: pennersales@hamilton.net Web Site: www.pennercareinc.com