The Green Deal Occupancy Assessment

Similar documents
Stroma Certification Ltd

Appendix T: Improvement measures

Improvement schedule for SAP May 2014 Note 8 revised 29 May 2014 NI high/further measures corrected 17 July 2014

Appendix T: Improvement measures for Energy Performance Certificates

Energy Efficiency Rating

RdSAP Conventions for SAP 2009

A GUIDE TO SWITCHING ENERGY AND STAYING WARM

Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:

A 92 plus B C D E F 21-38

Energy Performance Certificate

Stroma Certification Ltd

Energy Efficiency Rating

Energy Saving Service

Leaseholder Energy Efficiency November 2011

Spring/Summer Incentives

Spring/Summer Incentives

Energy Efficiency Advice.

This RdSap refresher course covers everything you would have learnt in your original training on the following aspects:

Energy Performance Certificate

Time to rethink heating

Energy Efficiency Rating

Related party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year

Hot water This guide will help you choose the right hot water system for your home and show you how to reduce your hot water costs.

TRIME Energy training for social Housing staff

Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

A 92 plus B C D E 39-54

Every Penny Counts. Cut your fuel bills how to save energy and switch supplier

Energy Efficiency Rating

Table 1: Hot water energy requirements

DEA Name Address Line 1 Open Fireplaces Number of rooms with a bath and a shower STROMA No. Address Line 2 Habitable Rooms Number of rooms with

REDUCED DATA SAP Collected data set:

Energy and you. A guide to energy efficiency in your home. Energy and You A5.indd 1 26/10/ :15

Your property and you

Report 9: Domestic appliances, cooking & cooling equipment

2 Harding Grove Stone, ST15 8GT 595,000

Your guide to a more

SMART METERS ANSWER BOOK HOW YOU WHY ONTARIO WHAT ARE GETTING SMART ABOUT CAN START TO PREPARE NOW PAGE 6 TIME-OF-USE PRICES? PAGE 4 IS INTRODUCING

Contents. General appliance information

Project Name: Ebico Trust Caseworker

61 Gleneagles Way Fixby Huddersfield HD2 2NH. Offers Over 250,000. Professionalism with Independence

Boiler Replacement Scheme Boiler Installer Form

BNWAT28: Water consumption in new and existing homes

Understanding your Central Heating System

Oxfordshire Community Groups & Volunteers. Top Tips. Compiled by Dale Hoyland, Strategic Development Manager, NEF

Identifying Heating Controls, Meters and Flues.

ELECTRICAL INSTALLATION PERMIT HOMEOWNER

21 Exley Lane Elland HX5 0SW 235,000. Professionalism with Independence. 12 Victoria Road, Elland, HX5 0PU t:

Powerful Money Saving Ideas BROUGHT TO YOU BY TVA AND YOUR LOCAL POWER COMPANY

15 Brickdale House, Stevenage Price 209,000

Domestic Green Deal Advice Training

Tips for saving energy and money around your home

Energy Efficiency in New Housing

energy use introduction

CITY OF BARTOW (COB)

CS027 User Instructions

How to save energy around the home. Remember The cheapest energy is the energy you don t use

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Bristol City Council Private Rented Sector Fire Safety Standards

Home owner user pack for the Nibe 200P

4 Butts Way Farnley Tyas Huddersfield HD4 6UA 240,000. Professionalism with Independence. 14 St Georges Square, Huddersfield, HD1 1JF t:

Heating and hot water

30 Lutterworth Road, Tunstall, Sunderland, Tyne And Wear, SR2 9AX 185,000

meters explained The benefits How it works Water efficiency

WATT s Up? What You Can Do To Reduce Your Home Energy Costs

BNDH EWH01: Domestic Electric Water Heaters Government Standards Evidence Base 2009: Key Inputs

Energy: Synthesis and Analysis

Smart meters. Everything you need to know to get Gaz & Leccy under control. Smart Energy GB, the voice of the smart meter rollout.

Understanding your supply area and meter types. Help Beat Cancer Fixed Price Energy January 2019 v2

Energy Ambassadors Guide

Using Less (Electricity) Gary Pain Merseyside Renewable Energy Initiative

1. Austria. Around one third of dwellings are over 60 years old (STAT, 1998b).

SAVING ENERGY AROUND THE

Recommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008

C-Stat 17-ZW User Instructions

You will investigate the electrical consumption in your home over the course of TWO days (48 hour period).

131 Mount Road, High Barnes, Sunderland, Tyne And Wear, SR4 7QB 199,950

Save energy Save money

EasySave. Come on, let s cut our bills! Affordable Warmth Helpline

Outdated Publication, for historical use. CAUTION: Recommendations in this publication may be obsolete. Family Community Education.

The importance of hot water system design in the Passivhaus

A storage solution: The role of off-peak electric heating in reducing fuel poverty

HEATING SYSTEMS. A guide to your central heating system and helpful energy saving advice.

Domestic Hot Water production

A Method to Disaggregate Structural and Behavioral Determinants of Residential Electricity Consumption Stanford ARPA-E Buildings Research

Energy Efficiency Standards

Conservation Council of South Australia The Green Hubs Guide Energy saving ideas for community organisations

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for 'System A' Installation Configuration

Extended 4 bedroom semi detached village house. 109 Orchard Way, Knebworth, SG3 6BT

Base-Load Electricity Usage - Results from In-home Evaluations

6 Hathaway Gardens, Barnes, Sunderland, Tyne And Wear, SR3 1UD 189,950

Energy Saving Tips. Our Top WHAM Wskazówki dotyczące oszczędzania energii nasz Top 40

VacCalc. Help and Operating Instructions. Overview

A Profile of a Refrigerator Recycling Program

Understanding Household Electricity Use

Energy Center of Wisconsin Residential Characterization Study Homeowner Survey

45 Kilhorne Gardens Belfast BT5 6NT

Our Code of Practice

TIPS ENERGY THE LESS YOU USE, 65 WAYS TO REDUCE HOME ENERGY USE THE MORE YOU SAVE CONSERVATION

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

Transcription:

The Green Deal Occupancy Assessment

Outline of the Green Deal Home visit and the Occupancy Assessment 2

Outline of the Green Deal Home Visit Occupancy Assessment 1. Contact the customer in advance of the visit to explain what is entailed and to ask them to have ready any relevant info, such as fuel bills, receipts or guarantees for any work done. Also ask if they already have an EPC (especially if they have recently moved into the home) if so, and they cannot find it, obtain their permission to look it up on Landmark. 2. Visit at the agreed time and discuss the visit with the customer. Explaining all points on your sign off sheet/check sheet, to make sure the customer is fully informed about the process before the assessment begins

Outline of the Green Deal Home Visit Occupancy Assessment 3. Inspect the property and talkto the customer to determine how the occupiers uses there home in practice if possible taking information from their fuel bills, and the usage of their appliances e.g. refrigerator Tumble Dryer Do Not Make Assumptions 4. If possible, immediately enter the data gathered into the Green Deal Advisor software and compare the customer's fuel bills with the estimates in the EPC and OA.

Outline of the Green Deal Home Visit Occupancy Assessment 5. Talk to the customer about their use of the installed energy using systems, particularly how they use any controls, to establish if any high energy use is down to the way the customer uses them. Find out whether they fall into any category that may receive funding help from the Energy Company Obligation (ECO).The ECO works alongside the Green Deal finance offer by targeting appropriate measures at those households likely to need additional support in particular those containing vulnerable people on low incomes and in hard-to-treat housing.

Outline of the Green Deal Home Visit Occupancy Assessment 7. Use the outputs from the GDAR to consider what improvement measures and/or behaviour changes would help to reduce the customer's fuel bills. Reviewing the recommendations produced by the GDAR will provide estimates of the savings that can be expected from them and an indication of whether the suggested measures will satisfy the Golden Rule. Be aware that some options for improvements, will almost certainly be beyond green Deal funding, but might still be a viable solution if the customer is willing to provide some of their own funding from savings or a separate loan.

Outline of the Green Deal Home Visit Occupancy Assessment 8. Discuss these options, their relative costs, disadvantages and benefits, with the customer, and agree the types of improvement that the customer wishes to consider. 9. Discuss possible low cost, no cost measures with the customer to improve their energy saving and to begin saving immediately

Outline of the Green Deal Home Visit Occupancy Assessment 10. Encourage the customer to adopt a programme of whole house improvement, which is generally more cost effective and less disruptive than making individual improvements one at a time, one large saving item may also pay fully for additional energy saving items. For example, for a solid wall home, internal wall insulation maybe under consideration; if the customer is considering refitting the kitchen, this would be the ideal time to install wall insulation and also to replace older white goods with the most efficient options. To an extent, this will depend on funding availability and the financial circumstances of the customer, so again this should be handled tactfully. 11. If applicable discuss possible ECO Funding that may be available to offset some of the upfront costs 8

Occupancy Assessment Considerations 9

Occupancy Short Description: Number of occupants. Long Description: Total number of occupants normally living in the dwelling. Notes: This is just a straight count of the number of people who sleep in this dwelling on at least half of the nights in a year, regardless of their age/size. The answer should be a whole number. Don t attempt to correct for children (e.g. counting as half). Students living away from home during term time should be excluded from the count. 10

Showers and Baths Short description: Type of shower and frequency of use of bath and shower Long description: What type of shower is present (if any)? How often is it used?how often is the bath used? Notes: If more than one shower type is present, choose the one that is used most Frequency of use can be asked in terms of uses per day/week/month, or whatever is easiest for the occupant, but record in uses per day (for the household as a whole) for input to the software. Given the personal nature of this question, some occupants may not wish toanswer it, in which case default values are used, resulting in a less accurate assessment of hot water use. Choose from the following shower types: None: No shower is present in this home. Unknown: Unidentifiable, or occupant doesn t know and won t let assessor see it. Mixer: Shower fed from hot water cylinder (not pumped), or combi boiler. Electric: Shower with an electric heating element which heats water at thepoint of use. Pumped: Power shower with an electric pump to increase the flow rate. 11

Property Details 12

Heating Systems Define main and secondary heating systems Which heating system is actually used as the main heating system in this household? Which second main system is actually used in this household? Which secondary system is actually used in this household? This question is about how occupants heat in practice in this home in winter. The choice of systems may therefore be different to what was assumedin the RdSAP assessment. Main, Second Main and Secondary systems can only be replaced with Secondary Heaters 13

Heating systems 14

Main heating The main heating system is defined as: A system which heats the largest proportion of the dwelling A system which is not usually based on individual room heaters (although it can be) A system which usually also provides the water heating If there is more than one heating system or device in a propertyuse the following process to decide which is the main heating system The main system usually provides both space and water heating and should heat at least 30% of the dwelling If no system provides space and water heating then select the system which heats the greatest part of the dwelling If there is still doubt then select the system which supplies useful heat to the dwelling at the lowest cost If the costs are the same then select the system which heats the living room

Additional main system If a dwelling has an additional main system then the proportion of the property heated by each system should be calculated. This should be basedon heated floor area to the nearest 10% If two systems serve the same heating circuit then assume there is a 50/50 split The main system should be the one which heats the living area Examples where an additional main system can be used A large property has two different boilers fitted so the whole property can be heated. One boiler is the main system the other is the additional main system. A property has a boiler fitted to replace storage heaters, but some functioning storage heaters are left in the property, the boiler is the main system and the storage heaters are the additional system

Secondary heating Secondary heating must be based on fixed room heaters. A fixed room heater is an independent heater not on a central system, such as a gas fire or electric panel heater. The heater must be fixed in place, soportable heaters are not included in the assessment. Secondary Heater selection: 1. Select the type of heater which heats the greatest number of habitable rooms 2. If that does not resolve the choice then select the heater whichis cheapest to run, based on fuel cost 3. If that still does not narrow it down, select the device with the lowest efficiency 4. Make use of the Second main system

Heating Systems The selection once the Heating systems are defined are for Room Heaters only, Selections are Main Heating As RdSap Room Heater 18

Heating Systems Fuel Category Gas Oil Solid Electric Fuel: this refers to the type of fuel selected e.g Mains Gas, LPG etc 19

Heating Systems Selection for Room Heaters depend on the Fuel they are burning 20

Rooms Heated By Each System Short description: Habitable rooms heated by each system Long description: Identification of which rooms are heated and by which heating system The living area comprises rooms normally heated to a higher temperature than the rest of the house). Indicate rooms as partially heated if normally kept at a lower temperature (e.g. TRV set 1 or the frost setting because room rarely used). It is possible to have more than one system for a room (commonlythe main living room having both central heating and a focal point fire). The following table illustrates. 21

Rooms Heated By Each System 22

Living Area Temperature Living area Temperature: The temperature to which the living area is normally heated The temperature reached on a normal day in winterin the living room when the heating has been on long enough to reach the occupants desired temperature. If the thermostat is in the living room and is used in the normal way (i.e. generally left in one position) record the thermostat set point. If the thermostat is not in the living room, add 3 C to the set-point to estimate the living room temperature. If there is no thermostat, or it is frequently adjusted, a reliable estimate cannot be made, so record unknown. (Where programmable thermostats are used (with the possibility of having a variable set point) use the highest set point for the most common day type (e.g. even if a higher set-point is used at the weekend, use the weekday maximum). 23

Heating Patterns The hours of heating on a typical week in winter On a normal day, the hours during which the heating is normally on and on an alternative day, the hours during which the heating is normally on. How many days of the week is the alternative heating pattern used? Only need to provide alternative hours if the heating is used differently on some days of the week (e.g. longer hours at the weekend). Record up to 4 heating periods per normal day and up to 4 per alternative day. More than 4 will be extremely rare, but if necessary combine any remaining hours into the 4th. 24

Heating Patterns For each period of heating, record the on time and the off time.in cases where a programmer is present, the occupant may know their on and off time to the nearest minute, in which case enter them to this level of accuracy, but in other cases times to the nearest half an hour would be adequate. Total number of hours on is not sufficient, because the hours the heating is off between heating periods is needed to estimate how much the house cools to get the right average internal temperature. The number of days per week the alternative heating pattern is used doesn t necessarily have to be a whole number. 25

Heating Patterns Example heating pattern Number of days per week alternative pattern used 26

Tumble Dryer Short description: Level of use of tumble dryer Long description: During a year, what proportion of clothes drying is done usinga tumble dryer? Enter zero if not present. If present, estimate proportion of drying that is done using the tumble dryer over the course of a year, considering the alternatives (e.g. indoor drying racks). You must enter the figure as a Ratio e.g. 50% = 0.50 Is there space for outside drying: Yes/No There has to be physical space for external drying outside of the property, rotary washing lines do not have to be seen as they are removable. 27

Cold Appliances Short description: Number of cold appliances present Long description: How many are present (and normally plugged in)? Fridges Fridge-freezers Freezers The only pitfall here is to avoid any misunderstanding with the customer of definitions, by using the terminology stand-alone freezers, stand-alone refrigerators and fridge-freezers. This should avoid a fridge freezer being counted twice as a fridge and a freezer. Wine coolers are counted as fridges 28

Appliances 29

Cooking Hob type and size, and oven type What type of hob is present What type of oven is present Beware look-alike ranges, which are functionally just normal cookers. Record as arange cooker only if it stays hot all the time. Choose from: Gas Electric Range, and the fuel used Other Hob size Large (more than 4 burners) Normal Beware look-alike ranges, which are functionally just normal cookers. Record as a range cooker only if it stays hot all the time. 30

Cooking Range cooker selection: Always Hot (all Year) Should have a Summer Winter Switch Always Hot (Winter) 31

Bill Data Bill Data = amount of each fuel used during a recent 12 month period and a code number indicating the reliability of the data. This should be based on the best evidence available, Bill data (Fuel bills which often contains an annual usage figure) Fuel delivery receipts/invoices (e.g. for oil, LPG etc ) This evidence must relate to the current occupants and the current dwelling. In some cases there will be no evidence and unknown should be recorded, for example if the occupants have recently moved in. The reliability code is used to set an appropriate range of uncertainty for the outputs. 32

Bill Data Reliability Level Description 1 Metered mains gas/electricity consumption based on actual meter readings, not estimates. 2 Metered gas/electricity consumption based on estimated reading, or oil/lpg consumption based on invoices/receipts 3 Solid fuel consumption based on invoices/receipts 4 Unknown: no reliable data; includes fixed charge community heating 5 Unusual energy-using item affecting this fuel* *Identify any major energy using items present which are outsidethe scope of the model s ability to predict, for example a heated swimming pool. In this case the bill data is not used for the assessment 33

Bill Data The annual fuel should be recorded in kwh where possible for electricity and metered gas. For other fuels record the quantity: -mains gas: cubic metres or cubic feet -LPG: litres or kg - heating oil: litres -solid fuel: tonnes or kg If the data does not relate to 12 months, a period between 11 and 13 months is acceptable but there must be no gaps. Record the period to whichthe bill data relates. In some cases information may only be available on the amount paid for fuels. In this case record the total amount for each fuel concerned. 34

Fuel Tariffs The fuel tariffs paid by this household Obtain the information from fuel bills. Tariffs for electricity and mains gas are either in the form of a standing charge and a unit price or a unit price for a first number of units and another unit price for additional units: record all details. In the case of LPG, oil and solid fuels record the total number of units purchased and the total amount paid. 35

Information Collection for the Occupancy Assessment 36

Data To Be Collected For Input To Software Item Data Comment Number of occupants Main heating 1 Main heating 2 Secondary heating Whole number as RdSAP assessment or heating code from SAP table 4a/4b as RdSAP assessment or heating code from SAP table 4a/4b as RdSAP assessment or heating code from SAP table 4a Use as RdSAP assessment whenever relevant. Identification of particular systems is needed only where the occupancy assessment assigns different systems 37

Data To Be Collected For Input To Software Heating by rooms (enter 1 in each applicable cell) Habitable Rooms Living Room Other Room 1 Other Room 2 Other Room 3 Other Room 4 Heated by main system 1 Heated by main system 2 Heated by secondary heaters Partially Heated Not Heated (continue as necessary) Comments. Enter data for habitable rooms only; omit other rooms (e.g. kitchen) and circulation spaces whether heated or not. Living area comprises rooms normally heated to a higher temperature than the rest of the house. Each room must be indicated as heated by at least one system or as unheated. A room can be heated by two systems (e.g.main and secondary). In the case of a partially heated room indicate also the system that provides heat to it. 38

Item Data Comment Living Area Temperature unknown or value Nearest 1 C Heating pattern, normal day Heating pattern, alternative day Showers and baths On 1 Off 1 On 2 Off 2 On 3 Off 3 On 4 Off 4 As above; also record number of days per week using alternative pattern Shower type: one of -none -mixer -pumped -electric -unknown Baths per day (if known) Showers per day (if known) Include times for the identified number of separate periods per day. Enter time in hours and minutes. If more than one shower select value for the one used most often. Number per day is for the household as a whole and is a decimal number, e.g. 2.6 39

Item Data Comment Tumble dryer Space for outside drying Fraction (0 to 1) Yes/No 0 if no tumble dryer. Otherwise householder s estimate of proportion of all clothes drying done in dryer. Cold appliances Cooking Number of each of: - stand-alone fridge - stand-alone freezer - fridge-freezer Hob/oven type, one of -gas -electric -range -other If range, also its fuel stand-alone means it performs only one of the two functions (a small freezing compartment as is present in most fridges does not make it fridge-freezer, which is a unit with two separate compartments) 40

Item Data Comment Community heating Electricity bills Gas bills Other fuels purchased Unusual energy-using item present Yes/no and if yes one of -charging based on amount of heating used - fixed charge If based on amount of heating used in kwh per year - kwh -Period to which this relates complete tariff data below - kwh -Period to which this relates complete tariff data below Complete other fuel below for each other fuel Yes/no and if yes then short description and the fuel it affects Fixed charge includes cases where charge is incorporated in rent Period in months e.g. 12, 12.5, should be approx 1 year. Where spread over more than one bill, add up and enter total Period in months e.g. 12, 12.5, should be approx 1 year. Where spread over more than one bill, add up and enter total e.g. heated swimming pool 41

Electricity tariff standard domestic tariff Reliability level Charging basis One of - actual readings - estimated readings -unknown One of - standing charge and unit price -two unit prices If standing charge -amount ( or p) -period p/day or /month or /quarter -p/kwh If two unit prices: Initial unit price Follow-on unit price -p/kwh -units at this price -per month or per quarter -p/kwh Select actual if that applies to the first and last reading of the total period. If unknown omit the data in the remainder of this table 42

Electricity tariff off peak tariff Reliability level Charging basis One of - actual readings - estimated readings -unknown One of - standing charge and unit price - two high-rate unit prices If standing charge -amount ( or p) -period p/day or /month or /quarter /year - high-rate p/kwh - low-rate p/kwh If two unit prices: Initial high-rate unit price Follow-on high-rate unit price Low-rate unit price -p/kwh -units at this price -per month, per quarter, per year -p/kwh -p/kwh Select actual if that applies to the first and last reading of the total period. If unknown omit the data in the remainder of this table 43

Gas Tariff Reliability level Charging basis One of - actual readings - estimated readings -unknown One of - standing charge and unit price -two unit prices If standing charge -amount ( or p) - period p/day /month /year or /quarter -p/kwh If two unit prices: Initial unit price Follow-on unit price -p/kwh -units at this price -per month per quarter per year -p/kwh Select actual if that applies to the first and last reading of the total period. If unknown omit the data in the remainder of this table 44

45

46

Any Questions? 47