User s Guide. LVU-800, & LV U Ultrasonic Level System

Similar documents
User s Guide. Shop online at. Made in China. Two-wire Display and Control Unit

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

LVCN-302 Set-Up Manual for Sump Model

User s Guide. Setpoint Option Card. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. OSXL685 and OSXL689. High Performance Infrared Thermometer. Shop online at

User s Guide OS210-C4. IR Temperature Sensors. Shop online at omega.com. For latest product manuals: omegamanual.

OMEGA (MODEL:610LF) OS642F-LS Infrared Thermometer With Laser Marker

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

User s Guide. FLSW Series ROTAMETER WITH ALARM. Shop online at omega.com. For latest product manuals:

LDP-124 AND LDP-144 SERIES FOR TEMPERATURE

OMEGA. OS643E-LS/OS643E Infrared Thermometer With Laser Sighting

User s Guide. DPF-520 Series XXXXXX. Shop online at. omega.com For latest product manuals: omegamanual.info

User s Guide TOTE SERIES. Wrap-Around Tote Tank Headers. TOTE SERIES Wrap-Around Tote Tank Heaters. Shop online at omega.com

User s Guide. Shop online at. omega.com CN Chromalox Rev Set Point. Load. Alarm.

User s Guide OS137 SERIES. Miniature Non-Contact Infrared Temperature Sensor/Transmitter. Shop online at omega.com

User s Guide FST1000 SERIES. Air Flow Switch with Two SPST Relay Contact Closures. Shop online at omega.com

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

PHH-60/PHH ph/conductivity Meter. Newport Electronics, Inc. Operator s Manual PHH-60 ON OFF. ph/conductivity METER

OMB-DAQ-TC-RACK-EXP32

DPG300 SERIES M-5258/0213

User s Guide. Shop online at omega.com. For latest product manuals: WITH REMOTE SENSOR PROBE FMA100XR

Duct Temperature Sensors

Duct Humidity/Temp Sensor

Series: MBC1-TC Mini Benchtop Temperature Controller

Outside Air Humidity & Temperature Sensor

Room Humidity/Temp Sensor

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Digital Pressure Gauges with Alarms and 4-20 ma Output

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Installation and Operating Instructions

User s Guide RH650. Shop online at omega.com SM. 9-In-1 Thermo-Hygrometer/ Moisture Meter

Environmental Monitoring SmartSlot Card

MDS8PT. Universal Temperature & Process Benchtop Meter with Alarms

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SEC 2000 Millenium Infrared Gas Detector

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

89BSD Digital Output

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MSP100 Pressure Transducer

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Mark 25 Ultrapure Water Conductivity Analyzer

Duct Mount. Installation Instructions

User s Guide OS100E SERIES. Mini-Infrared Transmitters. Shop online at omega.com. For latest product manuals: omegamanual.

NT DUAL CHANNEL DISPLAY. User Guide

430128A. B-Series Flow Meter SIL Safety Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

PodView Level Indicator LI40 Series Manual

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

DP86 Constant Voltage with Fitting

Inline Heater for Solvent or Gas. Installation and Operation Manual

M5800 Pressure Transducer with Rotatable Display

SEC Signature Process Gas Analyzer

MSP100 Pressure Transducer

User s Guide OS-MINI22 SERIES. Shop online at omega.com SM. For latest product manuals: omegamanual.info

SEALING FIBER SEALING COMPOUND

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

M5200 Industrial Pressure Transducer

Toroidal Conductivity Transmitters Series APT4000 Specifications

D5100 Industrial Differential Pressure Transducer

Microprocessor-Based Temperature/Relative Humidity Recorder

86BSD Digital Output

U5300 Industrial Pressure Transducer

Environmental Monitoring Card

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Model 4001 Series Single Channel Controller

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

MSP340 Pressure Transducer

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Owner s Manual. PIR-1 IR Learner

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Remote Relay Module (RRM)

3820, 3820i, 4820, 4820i

M5800 Pressure Transducer with Rotatable Display

SKORPION Process Air Heater

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

86BSD Digital Output

Air Pump Up to 800 gallons

D5100 Industrial Differential Pressure Transducer

RK/ RK Oxygen Detector Operator s Manual

MEAS CAL ALARM WASH CONF APT4000 TC

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

PM-200 Power Module Operating Instructions

MS4525 SPECIFICATIONS

1022 R/T Remote Monitor

Warranty Registration

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Carbon Dioxide Sample-Draw Detector Operator s Manual

M7100 Pressure Transducer

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Master Prep Chopper OWNER S GUIDE QB600W

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

VX SERIES Wireless Thermostat with Occupancy Sensor

Incutrol/2 Regulator

Vanguard. Toxic & combustible gas detector

Transcription:

M-2051 1/22/02 1:03 PM Page 2 W h e re Do I Find Everything I Need for P rocess Measurement and Control? OMEGA Of Course! Shop online at www.omega.com T E M P E R AT U R E Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories F L O W / L E V E L Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers p H / C O N D U C T I V I T Y ph Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial ph & Conductivity Equipment D ATA ACQUISITION Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters H E AT E R S Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters E N V I R O N M E N TA L MONITORING AND CONTROL Metering & Control Instrumentation R e f r a c t o m e t e r s Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment ph, Conductivity & Dissolved Oxygen Instruments M2051/0102 User s Guide Shop online at www.omega.com e-mail: info@omega.com LVU-800, & LV U - 1 1 0 0 Ultrasonic Level System

M-2051 1/22/02 1:03 PM Page 4 Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: OMEGAnet Online Service w w w.omega.com 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA Customer Service: 1-800-622-2378 / 1-800-622-BEST Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico: En Español: (001) 203-359-7803 e-mail: espanol@omega.com FAX: (001) 203-359-7807 info@omega.com.mx Servicing Europe: Internet e-mail i n f o @ o m e g a. c o m Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl Czech Republic: Rude armády 1868, 733 01 Karvina 8 Tel: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free: 0800-1-66342 e-mail: czech@omega.com France: 9, rue Denis Papin, 78190 Trappes Tel: +33 (0)130 621 400 FAX: +33 (0)130 699 120 Toll Free in France: 0800-4-06342 e-mail: sales@omega.fr Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.dl United Kingdom: One Omega Drive, River Bend Technology Centre ISO 9002 Certified Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s C u s t o m e r Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by O M E G A, if the unit is found to be defective, it will be repaired or replaced at no charge. O M E G A s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of O M E G A s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2001 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

M-2051 1/22/02 1:03 PM Page 6 5 System Configuration Document Unpacking Instructions ZERO : inches from sensor face SPAN : inches from zero ALARM 1 : inches from sensor face (K1-RELAY) ALARM 2 : inches from sensor face (K2-RELAY) ALARM 3 : inches from sensor face ALARM 4 : inches from sensor face LINEAR CHARACTERIZATION - DISPLAY LOW VALUE : HIGH VALUE: If you select SLFC mode 1 = Automatic fill control 2 = Automatic empty control Alarm #1 relay will act as a auto fill / auto empty control relay Remove the Packing List and verify that you have received all equipment, including the following (quantities in parenthesis): LVU-800 & LVU-1100 Ultrasonic Level Measurement System (1) Operator s Manual (1) If you have any questions about the shipment, please call OMEGA Customer Service Department. When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing mat erial and carton in the event reshipment is necessary. 14 i

M-2051 1/22/02 1:03 PM Page 8 T A B L EO F C O N T E N T S LVU-800 & LVU-1100 Series Ultrasonic Level Systems 5 System Configuration Document SECTION 1 SYSTEM DESCRIPTION SECTION 2 INSTALLATION 1.1 System Description 1 1.2 Principles of Operation 1 2.1 Control Unit Installation 2 2.2 Sensor Installation 2 2.3 Wiring Diagram (Fig. 1) 3 2.4 Calibration Diagram (Fig 2) 4 SECTION 3 LVU-1100 PROGRAMMING DESCRIPTION AND PROMPT LIST 3.1 General 6 3.2 Calibration Procedure 6 SECTION 4 LVU-800 PROGRAMMING DESCRIPTION AND PROMPT LIST 4.1 General 9 4.2 Calibration Procedure 9 4.3 Dimensional Drawings 12 SECTION 5 SYSTEM CONFIGURATION DOCUMENT 5.1 General 13 SITE LOCATION ID: JOB: UNIT SERIAL NUMBER DATE: PROGRAMMABLE PARAMETERS, PROGRAMMED BY: HEIGHT MODE: DISTANCE MODE: ANALOG OFFSET: Y 4-20 ma 2-10 V N 0-20 ma 0-10 V DISPLAY MODE: 0 1 2 LOST ECHO MODE: 0 1 2 STD. ALARM AUTOMATIC FILL AUTOMATIC EMPTY ii 13

M-2051 1/22/02 1:03 PM Page 10 4 LVU - 800 Programming 1 System Description SECTION I SYSTEM DESCRIPTION 1.1 GENERAL DESCRIPTION The OMEGA Model, LVU-800 / LVU-1100 Series Liquid Level Systems are state-of-the-art level measurement instruments. Based on the latest ultrasonic technologies, the LVU-800 / LVU- 1 1 0 0 Series provide an efficient, reliable and cost effective means of level control. The LVU-800 / LVU-1100 Series consist of 2 major components: a non-contacting ultrasonic sensor and a compact, remote electronic control. The LVU-800 / LVU-1100 Series sensor is available in a variety of sizes and materials to suite virtually any application. Standard mounting configurations include 3 / 4 and 2 NPT fittings. Sensor materials of construction include 316 SS, kynar or teflon. *3/4 NPT Teflon Sensor Length 2 (50.8mm) STD LVU-1100 Series LVU-800 Series 4-20 MA Transmitter continuous output with two programmable alarm relay with auto fill / auto empty mode. Two programmable alarm relay with independent alarm, auto fill / auto empty mode. 1.2 PRINCIPLES OF OPERATION DIMENSIONAL DRAWINGS 12 In operation, the electronics generates an electronic signal that is converted by the sensor (mounted on top of the vessel) to a burst of ultrasonic pulses. These pulses are transmitted through the air towards the liquid surface. As the pulses reach the liquid surface, they are reflected back to the sensor. These received echoes are converted back to an electronic signal, which is then sent to a microprocessor. The microprocessor uses the return signals to calculate the it takes for the pulses to travel to the liquid surface and back. This Time of Flight is directly proportional to the distance of the liquid surface from the sensor. The microprocessor then compares these calculated values with user programmed system parameters to provide the required control output. 1

M-2051 1/22/02 1:03 PM Page 12 2 System Description LVU - 800 Programming PROMPT DEFINITION DESCRIPTION 4 SECTION II INSTALLATION 2.1 CONTROL UNIT INSTALLATION 1. Open control unit enclosure and remove the printed circuit board. 2. Replace printed circuit board, and route power and control wiring to the enclosure. Observe all applicable local electrical codes and wiring procedures. S L _ S SELECT SPAN PROGRAMS THE SYSTEMS ANALOG OUTPUT SPAN MEASURED IN INCHES FROM THE ZERO POINT. S L L E SELECT LOST PROGRAM ONE OF THE THREE ANALOG VARIABLES ON SIGNAL ECHO LOSS OUTPUT 0 = OUTPUT GOES TO 4 ma 1 = OUTPUT HOLDS LAST G O O D V A L U E 2 = OUTPUT GOES TO 20 ma 3. Connect power and control wiring to the control unit as shown in the wiring diagram (see figure 1). 4. Be sure that all wiring is carefully dressed to prevent pinching between the housing and the cover. 2.2 Sensor Installation The sensor is mounted on the top of the vessel with the sensor facing downward. A clear path, free of any obstructions, must be provided between the sensor and the liquid surface. Due to the narrow sensor beam pattern, vertical-axis positioning of the sensor is important. The sensor must be installed so as to maintain perpendicularity to the liquid surface. 1. For sensors provided with an NPT threaded fitting, drill a suitable hole in the vessel top and tap for the correct NPT thread. In thin walled vessels, or vessels constructed of material not suitable for tapping, weld or braze a bushing to accept the sensor. 2. Screw the sensor into the threaded fitting, being careful not to cross thread the sensor. When possible, the use of a pipe compound or sealing tape is recommended. AVOIDOVER TIGHTENING! 3. For flange mounted sensors, simply bolt the sensor / flange assembly to the proper mating flange connection. 4. Route the sensor cable to the electronic control unit and connect per the Wiring diagram (see fig 1). IF ROUTING THE SENSOR CABLE THROUGH CONDUIT, A DEDICATED CONDUIT SHOULD BE UTILIZED. AVOID ROUTING THE SENSOR CABLE IN CLOSE PROXIMITY TO ANY SOURCEOF ALTERNATING CURRENT OR RFI. 1. 1-3 OPERATION MODE: AUTOMATIC FILL / AUTO FILL WITH ALTERNATE PUMP CONTROL 2. 2-4 OPERATION MODE: AUTOMATIC FILL / AUTO FILL WITH ALTERNATE PUMP CONTROL PROGRAM PARAMETER: SLAH SLAL 3. 5 OPERATION MODE BOTH PUMPS ARE OFF WHEN LEVEL IS BELOW SLAL. AS THE LEVEL INCREASES TO SLA3 PUMP #1 / OR PUMP #2 STARTS, PUMP STAYS ON UNTIL THE LEVEL DECREASES BELOW SLAL THEN STOPS. IF THE LEVEL CONTINUES TO INCREASE UP TO SLAH PUMP #2 / OR PUMP #1 COMES ON AND DECREASES BELOW SLAL. PROGRAM PARAMETER: S L A H S L A L S L A 3 2 11

M-2051 1/22/02 1:03 PM Page 14 4 LVU-800 Programming PROMPT DEFINITION DESCRIPTION Installation 2 S L A 1 SELECT ALARM PROGRAM ALARM RELAY #1 TRIP RELAY 1 AS DESIRED, MEASURED IN INCHES FROM FACE OF PROBE EXAMPLE: 18 = 0 1 8.0 (THIS PROMPT NOT AVAILABLE IF S L F C IS SET TO 1 OR 2) 2.3 WIRING DIAGRAM S L A 2 SELECT ALARM PROGRAM ALARM RELAY # 2 AS RELAY 2 AS DESCRIBED ABOVE S L A H SELECT ALARM (THIS PROMPT ONLY AVAILABLE HIGH LEVEL IF S L F C IS SET TO 1 OR 5) PROGRAM THE HIGHEST LEVEL POINT AS MEASURE IN INCHES FROM THE SENSOR FACE FOR ALL 2-5 OPERATIONS. S L A L SELECT ALARM (THIS PROMPT ONLY AVAILABLE LOW LEVEL IF S L F C IS SET TO 1 OR 5) PROGRAM THE LOW LEVEL POINT AS MEASURE IN INCHES FROM THE SENSOR FACE FOR ALL 2-5 OPERATIONS. S L A 3 PUMP START PROGRAM PUMP START LEVEL POINT LEVEL AS MEASURED IN INCHES FROM THE SENSOR FACE. THIS PROMPT IS ONLY AVAILABLE IF SLFC IS SET TO 5 S L D H SELECT THE HEIGHT MODE PROVIDES AN DISTANCE ANALOG OUTPUT PROPOTTIONAL MEASUREMENT TO THE LIQUID LEVEL, AND THE MODES DISTANCE MODE PROVIDES AN INVERSE OUTPUT. H = HEIGHT MEASUREMENT d = DISTANCE MEASUREMENT S L O S SELECT ALLOWS FOR AN ANALOG OFFSET ANALOG REFERENCED TO 0mA OR 4 ma EXAMPLE: 0-20 ma VERSUS 4-20 ma OR 0-10 Vdc OR 2-10 Vdc 1 = 4-20 ma dc 0 = 0-20 ma dc S L _ 0 SELECT ZERO PROGRAMS THE SYSTEM ZERO POINT FOR THE ANALOG OUTPUT AS MEASURED IN INCHES FROM THE FACE OF THE SENSOR THE SYSTEM ZERO SETTING IS THE POINT CLOSET TO THE SENSOR FACE. THE ZERO POINT WILL BE 20 ma IN HEIGHT MODE AND 4mA IN DISTANCE MODE. 10 3

M-2051 1/22/02 1:03 PM Page 16 2 Installation 2.4 CALIBRATION DIAGRAM 4 LVU-800 Programming SECTION IV LVU-800 PROGRAMMING DESCRIPTION AND PROMPT LIST 4.1 GENERAL The LVU-800 Series is calibrated via push-button entry switches (Program & Increment) and an onboard digital display, which provides the necessary programming prompts. All data entered during the calibration procedure is stored in a non volatile memory to prevent loss of data in the event of a power failure. During the calibration procedure you may refer to the programming Prompt List and the calibration diagram in this manual. DURI NG THE CALIBRATION PROCEDURE, IF NO BUTTONS ARE PUSHED FOR MORE THAN 60 SECONDS, THE SYSTEM WILL AUTOMATICALLY RETURN TO THE OPERATING MODE-SAVING THOSE PARAMETERS ALREADY ENTERED. 4.2 CALBRATION PROCEDURE 4 9 Unscrew the control unit cover and simultaneously depress and hold the Program and Increment buttons. After approximately three (3) seconds, the onboard programming display will issue the prompt COdE. Release both buttons and press the Program button. Follow chart below for programming setup. PROMPT DEFINITION DESCRIPTION S L F C SELECT RELAY DEFINES THE OPERATIONAL MODE FUNCTIONS ALARM RELAY #1, AS FOLLOWS 0=STD (INDEPENDENT ALARMS) 1=AUTOMATIC FILL CONTROLS 2=AUTOMATIC EMPTY CONTROL 3=LEAD/LAG WITH ALTERNATE PUMP AND AUTOMATIC FILL PUMP CONTROL 4=LEAD/LAG WITH ALTERNATE PUMP AND AUTOMATIC EMPTY PUMP CONTROL 5=ALTERNATE PUMP CONTROL WITH THREE SETTING, AUTO EMPTY MODE

M-2051 1/22/02 1:03 PM Page 18 3 LVU-800 Programming Installation 2 3.2 CALIBRATION PROCEDURE Con t S L _ S SELECT SPAN PROGRAMS THE SYSTEM ANALOG OUTPUT SPAN MEASURED IN INCHES FROM THE ZERO POINT. S L L E SELECT LOST PROGRAM ONE OF THE THREE ANALOG VARIABLES ON SIGNAL ECHO LOSS OUTPUT 0 = OUTPUT GOES TO 4 ma 1 = OUTPUT HOLDS LAST GOODVALUE 2 = OUTPUT GOES TO 20 ma 2.5 SPECIFICATIONS Range: Repeatability: Accuracy: 1-12 feet 1-30 feet ( 30 ft option) 1/8 inch typical Analog output - 1 /4% of full scale Temperature Compensation: Automatic over full range of sensor operating temperature Input Power: Output Signal: Alarm Setpoints: Temperature Range: Sensor Pressure Rating: Sensor Construction: Electronics Enclosures: 115 V ac, 50/60 Hz, 24 Vdc or 230 V ac optional 4-20 ma dc (isolated) or 0-10 Vdc Two independent programmable 10A SPOT relays increments of 0.1 over entire span Sensor - 20 F to + 180 F Electronics - 10 F to + 170 F 250 psig - 316 SS 100 psig - Teflon, Kynar, CPVC CPCV 316 SS, Kynar or Te f l o n NEMA 7 explosion-proof Class I, Division 1 & 2 Groups B, C&D Class II, Division 1 & 2 Groups E, F&G Class III, NEMA 3, 4, 7, & 9 8 Mountings: 5 3 /4 NPT: Range up to 12 Ft 2 NPT: Range up to 30 Ft

M-2051 1/22/02 1:03 PM Page 20 3 LVU-1100 Programming 3.2 CALIBRATION PROCEDURE Con t LVU-1100 Programming 3 SECTION III LVU-1100 PROGRAMMING DESCRIPTION AND PROMPT LIST 3.1 GENERAL PROMPT DEFINITION DESCRIPTION S L A 2 SELECT ALARM PROGRAM ALARM RELAY # 2 AS RELAY 2 AS DESCRIBED ON PAGE 6. The LVU-1100 Series is calibrated via push-button entry switches (Program & Increment) and an onboard digital display, which provides the necessary programming prompts. All data entered during the calibration procedure is stored in a non volatile memory to prevent loss of data in the event of a power failure. During the calibration procedure you may refer to the programming Prompt List and the calibration diagram in this manual. 3.2 CALBRATION PROCEDURE DURING THE CALIBRATION PROCEDURE, IF NO BUTTONS ARE PUSHED FOR MORE THAN 6 0 SECONDS,THE SYSTEM WILL AUTOMATICALLY RETURN TO THE OPERATING MODE-SAVING THOSE PARAMETERS ALREADY ENTERED. Unscrew the control unit cover and simultaneously depress and hold the Program and Increment buttons. After approximately three (3) seconds, the onboard programming display will issue the prompt COdE. Release both buttons and press the Program button. Follow chart below for programming setup. PROMPT DEFINITION DESCRIPTION S L F C SELECT RELAY DEFINES THE OPERATIONAL MODE FUNCTIONS ALARM RELAY #1, AS FOLLOWS 0=STD (INDEPENDENT ALARMS) 1=AUTOMATIC FILL CONTROLS 2=AUTOMATIC EMPTY CONTROL 3=LEAD/LAG WITH ALTERNATE PUMP AND AUTOMATIC FILL PUMP CONTROL 4=LEAD/LAG WITH ALTERNATE PUMP AND AUTOMATIC EMPTY PUMP CONTROL 5=ALTERNATE PUMP CONTROL WITH THREE SETTING, AUTO EMPTY MODE. S L A 1 SELECT ALARM PROGRAM ALARM RELAY #1 TRIP RELAY 1 AS DESIRED, MEASURED IN INCHES FROM FACE OF PROBE EXAMPLE: 18 = 0 1 8.0 (THIS PROMPT NOT AVAILABLE IF S L F C IS SET TO 1 OR 2) 6 7 S L A H SELECT ALARM (THIS PROMPT ONLY AVAILABLE HIGH LEVEL IF S L F C IS SET TO 1 OR 5) PROGRAM THE HIGHEST LEVEL POINT AS MEASURE IN INCHES FROM THE SENSOR FACE FOR ALL 2-5 OPERATIONS. S L A L SELECT ALARM (THIS PROMPT IS ONLY AVAILABLE LOW LEVEL IF S L F C IS SET TO 1 OR 5) PROGRAM THE LOW LEVEL POINT AS MEASURE IN INCHES FROM THE SENSOR FACE FOR ALL 2-5 OPERATION. S L A 3 PUMP START PROGRAM PUMP START LEVEL POINT LEVEL AS MEASURED IN INCHES FROM THE SENSOR FACE. THIS PROMPT IS ONLY AVAILABLE IF SLFC IS SET TO 5 S L D H SELECT THE HEIGHT MODE PROVIDES AN DISTANCE ANALOG OUTPUT PROPOTTIONAL MEASUREMENT TO THE LIQUID LEVEL, AND THE MODES DISTANCE MODE PROVIDES AN INVERSE OUTPUT. H = HEIGHT MEASUREMENT d = DISTANCE MEASUREMENT S L O S SELECT ALLOWS FOR AN ANALOG OFFSET ANALOG REFERENCED TO 0mA OR 4 ma EXAMPLE: 0-20 ma VERSUS 4-20 ma OR 0-10 Vdc OR 2-10 Vdc 1 = 4-20 ma dc 0 = 0-20 ma dc S L _ 0 SELECT ZERO PROGRAMS THE SYSTEM ZERO POINT FOR THE ANALOG OUTPUT AS MEASURED IN INCHES FROM THE FACE OF THE SENSOR THE SYSTEM ZERO SETTING IS THE POINT CLOSET TO THE SENSOR FACE. THE ZERO POINT WILL BE 20 ma IN HEIGHT MODE AND 4mA IN DISTANCE MODE.