QDV5V - 1 Door Standard (Gemtron)

Similar documents
QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

INSTALLATION & OPERATION MANUAL

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

IMPORTANT KEEP IN STORE FOR FUTURE USE

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Product Specifications Sheets

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Installation & Operation Manual

Introductions General Information. Receiving/Shipping Damage/Lost Items

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

C13-Series Engineering Guide

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

Installation & Operation Manual

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Introductions General Information. Receiving/Shipping Damage/Lost Items

TECHNICAL SPECIFICATIONS

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

TECHNICAL SPECIFICATIONS

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Installation & Service Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

LOW PROFILE UNIT COOLER

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

NFW, NCW, NFWG, NCWG, NFWE, NCWE

MAC-120HE-03 Air-Cooled Chiller

Unit Features & Benefits RQPM/RQRM Series

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Call us today! (800)

Center Mount Unit Coolers

TECHNICAL SPECIFICATIONS

Air-Cooled Condensing Units with Compact Screw Compressors

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

Specifications and Performance S2H

Call us today! (800)

Specifications and Performance

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

VertiCool Aurora Engineering Guide

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

Indoor Air Handlers with Compressors MVS and MVW

RMN with INNOVATOR Doors Technical Data Sheet

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Technical Specifications

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

MACH N-407 Heat Pump Air-Cooled Chiller

Call us today! (800)

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

horizontal air discharge outdoor discus condensing unit

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

TECHNICAL SPECIFICATIONS

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Condensing Units & Air Handlers

PRODUCT SPECIFICATIONS

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

KTL Two-Way Low Profile Evaporators

PAR5. Product Specifications

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Installation & Operation Manual. Reach-In Display Case. KW-IOM-2149 July 2016 Part No. 31E02149

June PRODUCT DESIGN GUIDE Whisperline Console

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

PPL Electric Utilities Energy Efficiency and Conservation Program

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

commercial refrigeration products

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

Technical Specifications

LK-PL Jan Price List

Transcription:

CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.51 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 All electrical data based on 115V and unlighted shelves. 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 29 17/32 4 1/2 REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) 42? Applications: Specification Sheet QDV5V - 1 Standard (Gemtron) that conditions do not exceed 75 F and 55% relative FOOT humidity. PRINT, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. STD Fan Case BTU - 1 N/A PSC Fan 876 ECM Fan 816 condensing unit, add 8% to BTUH load. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Evap (1 hr. after defrost) Air +28 F 200 FPM +34 F Issue: 2.11.2010

CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.57 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.25 All electrical data based on 115V and unlighted shelves. 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 29 17/32 4 1/2 REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) 42? Applications: Specification Sheet QDV5V - 1 Standard (Anthony) that conditions do not exceed 75 F and 55% relative humidity. FOOT PRINT, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. STD Fan Case BTUH - 1 N/A PSC Fan 876 ECM Fan 816 condensing unit, add 8% to BTUH load. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Evap (1 hr. after defrost) Air +28 F 200 FPM +34 F Issue: 2.11.2010

CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.41 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.25 All electrical data based on 115V and unlighted shelves. 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 29 17/32 4 1/2 REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) 42? Applications: Specification Sheet QDV5V - 1 Eliminator (Anthony) that conditions do not exceed 75 F and 55% relative humidity. FOOT PRINT, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. STD Fan Case BTUH - 1 N/A PSC Fan 806 ECM Fan 746 condensing unit, add 8% to BTUH load. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Evap (1 hr. after defrost) Air +28 F 200 FPM +34 F Issue: 2.11.2010

CASE DATA 208V Circuit Data 2M 3M Power Supply 208/1/60 4M 5M Compressor RLA 4.20 5.70 5.70 5.70 Compressor LRA 16.80 24.10 24.10 24.10 Condenser Fan Motor Amps 0.70 0.70 0.70 0.70 Minim. Circuit Ampacity 5.95 7.83 7.83 7.83 Maxim. Overcurrent Protection 10 10 10 10 Horse Power 1/3 1/2 1/2 1/2 115V Circuit Data 2M 3M 4M 5M Anti-Sweat Amps (ELM ) 0.71 1.05 1.37 1.67 Evap Fan Motor Amps (PSC opt) 0.44 0.66 0.88 1.10 Evap Fan Motor Amps (ECM opt) 0.40 0.60 0.80 1.00 Light Amps (T8) 1.67 2.22 2.78 3.34 LED Light Amps (Optimax Pro) 0.33 0.50 0.66 0.83 Condensate Pump Amps 0.34 0.34 0.34 0.34 Condensate Evaporator Amps 8.00 8.00 8.00 8.00 Minim. Circuit Ampacity 12.10 13.23 14.41 15.53 Maxim. Overcurrent Protection 15 20 20 20 Power Supply 115/1/60 NOTE: Options are not available after January 1, 2012. Refrigerant - R404A Electric 3 35 min 40 F that conditions do not exceed 75 deg F and 55% relative humidity. Kysor/Warren, whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. QDV5V - MCU - Reach-In - Eliminator (Anthony) Air 300 FPM +32 F PSC Fan 820 ECM Fan 780 condensing units. Maintained temperature +38 F. The above case model has case lengths that are UL and NSF approved. Issue: 2.23.2012 Kysor/Warren BTU Per

CASE DATA 208V Circuit Data 2M 3M Power Supply 208/1/60 4M 5M Compressor RLA 4.20 5.70 5.70 5.70 Compressor LRA 16.80 24.10 24.10 24.10 Condenser Fan Motor Amps 0.70 0.70 0.70 0.70 Minim. Circuit Ampacity 5.95 7.83 7.83 7.83 Maxim. Overcurrent Protection 10 10 10 10 Horse Power 1/3 1/2 1/2 1/2 115V Circuit Data 2M 3M 4M 5M Anti-Sweat Amps (101 ) 0.85 1.28 1.71 2.13 Evap Fan Motor Amps (PSC opt) 0.44 0.66 0.88 1.10 Evap Fan Motor Amps (ECM opt) 0.40 0.60 0.80 1.00 Light Amps (T8) 1.67 2.22 2.78 3.34 LED Light Amps (Optimax Pro) 0.33 0.50 0.66 0.83 Condensate Pump Amps 0.34 0.34 0.34 0.34 Condensate Evaporator Amps 8.00 8.00 8.00 8.00 Minim. Circuit Ampacity 12.10 13.23 14.41 15.53 Maxim. Overcurrent Protection 15 20 20 20 Power Supply 115/1/60 NOTE: Options are not available after January 1, 2012. Refrigerant - R404A Electric 1 30 min 40 F that conditions do not exceed 75 deg F and 55% relative humidity. Kysor/Warren, whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. QDV5V - MCU - Reach-In - Standard (Anthony) Air 300 FPM +32 F The above case model, has case lengths that are UL and NSF approved. Kysor/Warren BTU Per PSC Fan 820 ECM Fan 780 condensing units. Maintained temperature +38 F. Issue: 2.23.2012

CASE DATA AMPS - Secondary Coolant: Glycol (Propylene) 2 DR 3 DR 4 DR 5 DR 35% 35% 35% 35% BTUH Heat Load 1900 2700 3600 4500 Glycol Rise +6 F +6 F +6 F +6 F Glycol Flow Rate (GPM) 0.695 0.987 1.316 1.645 Pressure Drop (PSI) 2.7 2.7 4.9 4.4 PSC Fan 0.44 0.66 0.88 1.10 STD Fan 0.70 1.05 1.40 1.75 ECM Fan 0.40 0.60 0.80 1.00 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED Light (Gelcore) 0.48 0.73 0.98 1.20 All electrical data based on 115V. QDV5V-A - Glycol - Standard Glass (Anthony) that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 800 PSC Fan 770 ECM Fan 740 Supply Air Velocity Air +20 F 225 FPM +34 F condensing units. ADD 8% to BTU LOAD. s Facing Area (ft²) Cubic Volume (ft³) 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ The above case model has case lengths that are UL and NSF approved. 5 60 ft² 151.8 ft³ Issue: 3.23.2010

CASE DATA AMPS - # of s 2 DR 3 DR 4 DR 5 DR Anti-Sweat 0.71 1.17 1.37 1.67 PSC Fan 0.44 0.66 0.88 1.10 STD Fan 0.70 1.05 1.40 1.75 ECM Fan 0.40 0.60 0.80 1.00 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED Light (Gelcore) 0.48 0.73 0.98 1.20 All electrical data based on 115V. QDV5V-A - Eliminator Glass (Anthony) that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 750 PSC Fan 720 ECM Fan 690 Evap Air Velocity Air +28 F 225 FPM +34 F condensing units. ADD 8% to BTU LOAD. s Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ 5 60 ft² 151.8 ft³ The above case model has case lengths that are UL and NSF approved. Issue: 3.2.2010

CASE DATA AMPS - # of s 2 DR 3 DR 4 DR 5 DR Anti-Sweat 1.04 1.43 1.93 2.40 PSC Fan 0.44 0.66 0.88 1.10 STD Fan 0.70 1.05 1.40 1.75 ECM Fan 0.40 0.60 0.80 1.00 Light (T8 ELS) 1.55 1.97 2.53 2.95 LED Light (Gelcore) 0.52 0.78 1.04 1.30 All electrical data based on 115V. QDV5V-A - Glass (Gemtron) that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 800 PSC Fan 770 ECM Fan 740 Evap Air Velocity Air +28 F 225 FPM +34 F condensing units. ADD 8% to BTU LOAD. s Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ 5 60 ft² 151.8 ft³ The above case model has case lengths that are UL and NSF approved. Issue: 3.2.2010

CASE DATA AMPS - # of s 2 DR 3 DR 4 DR 5 DR Anti-Sweat 0.85 1.28 1.71 2.13 PSC Fan 0.44 0.66 0.88 1.10 STD Fan 0.70 1.05 1.40 1.75 ECM Fan 0.40 0.60 0.80 1.00 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED Light (Gelcore) 0.48 0.73 0.98 1.20 All electrical data based on 115V. QDV5V-A - Standard Glass (Anthony) that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 800 PSC Fan 770 ECM Fan 740 Evap Air Velocity Air +28 F 225 FPM +34 F condensing units. ADD 8% to BTU LOAD. s Facing Area (ft²) Cubic Volume (ft³) 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ The above case model has case lengths that are UL and NSF approved. 5 60 ft² 151.8 ft³ Issue: 3.2.2010

CASE DATA - # of s 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps 0.71 1.03 1.37 1.67 PSC Fan Amps 0.44 0.66 0.88 1.10 STD Fan Amps 0.70 1.05 1.40 1.75 ECM Fan Amps 0.40 0.60 0.80 1.00 LED Light Amps (Gelcore) 0.48 0.73 0.98 1.20 T8 Lights 1.39 1.80 2.32 2.79 All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Off-Cycle 1 40 min 45 F Assorted Shelving Options Available QDV5VT-A - Tall Glass - Eliminator that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 785 PSC Fan 755 ECM Fan 725 condensing units, add 8% to BTU load. Add 30 BTUH/ for STD motors. 2 3 4 5 Facing Area (ft²) 25.1 37.3 49.8 62.2 Cubic Capacity (ft³) 60.7 91.0 121.4 151.8 Evap (1 hr. after defrost) Air +28 F 225 FPM +34 F The above case model has case lengths that are UL and NSF approved. Issue: 3.4.2010

CASE DATA - # of s 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps 0.85 1.28 1.71 2.13 PSC Fan Amps 0.44 0.66 0.88 1.10 STD Fan Amps 0.70 1.05 1.40 1.75 ECM Fan Amps 0.40 0.60 0.80 1.00 LED Light Amps (Gelcore) 0.48 0.73 0.98 1.20 T8 Lights 1.39 1.80 2.32 2.79 All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Off-Cycle 1 40 min +45 F Assorted Shelving Options Available QDV5VT-A - Tall Glass - Standard that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous -Jet and Air Defrost are registered trademarks of. BTUH per STD Fan 840 PSC Fan 810 ECM Fan 780 condensing units, add 8% to BTU load. Add 30 BTUH/ for STD motors. 2 3 4 5 Facing Area (ft²) 25.1 37.3 49.8 62.2 Cubic Capacity (ft³) 60.7 91.0 121.4 151.8 Evap (1 hr. after defrost) Air +28 F 225 FPM +34 F The above case model has case lengths that are UL and NSF approved. Issue: 3.4.2010