Installation guide. Philips EvoKit LED 2x4 and 2x2

Similar documents
WARNING WARNING WARNING

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

INSTALLATION INSTRUCTIONS

1 General Description

LED Flat Panel Retrofit

DHL-LP-LED Low Profile LED Linear High/Low Bay

1 x4 Dimmable LED RetroFits

Installation Instructions. Tersen. Ratio Canopy 1.5

Installation Instructions

Installation Instructions

Innovative Lighting R-Series Overhead LED Conversion Kits

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Innovative Lighting Smooth Light Recessed Luminaires

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Innovative Lighting R-Series Vertical Refrigeration

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Cold Door 2 LED Retrofit Kit Lighting System

LED IMPORTANT SAFETY INSTRUCTIONS

Honeywell Durafit LED Retrofit Kit

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

Dioluce Products Installation Instructions

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

MAXLITE RKT LED Retrofit Kit

SCENE 2x2 INSTALLATION INSTRUCTIONS. Recessed T-Bar GENERAL SAFETY INSTRUCTIONS: NOTE:

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Installation Instructions Labor and Delivery Exam Light Set

Lumination TM Volumetric Retrofit Kit

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED Emergency Battery Backup

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

installation and operation manual for Hunter Ceiling Fans

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Fillmore Small Pendant Assembly and Installation Instructions

SERVICE BY QUALIFIED PERSONNEL ONLY

Installation Instructions PANOS 5.25

INSTALLATION INSTRUCTIONS

SSC-1D installation guide

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

MaxLite LED High Bay Fixtures

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

LED IMPORTANT SAFETY INSTRUCTIONS

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

MaxLite LED Round Pendant Highbay Series

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR 53 OHIO STATE HIGHWAY PATROL VISTA LIGHTBAR ( OHPxx)

Bathroom Exhaust Fan/Fluorescent Light Combination

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Owner s Guide and Installation Manual

INSTALLATION INSTRUCTIONS

EcoBrite Smooth Light LED Light Fixtures

Cree XLamp CM Family LEDs

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

5Make electrical connections.

Installation Instructions

LED Edge-Lit Flat Panels

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

LED IMPORTANT SAFETY INSTRUCTIONS

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

PANOS. Installation Instructions Square, 5.25 Round Flangeless, Downlight. The following installation instructions relate to the options below

Important Safety Instructions. Important Safety Instructions

20-GALLON PARTS WASHER OWNER S MANUAL

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Table of Contents. What to Expect with. Mounting Options. Tools Needed

ELSTON 52 CEILING FAN

INSTALLATION INSTRUCTION In-Ground

PAR-KUT INTERNATIONAL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

STREAMLINE LP3 INCANDESCENT LIGHTS

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

PH:

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

UNITY CEILING RECESSED MOUNT CM1900 CM1901 CM1906 CM1912

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

e Heater/Exhaust Fan/Light User s Guide

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Bdl60u Fluorescent Emergency Ballast

FANAWAY LED EVO1 RETRACTING BLADE CEILING FAN

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

TROFFER RETROFIT KIT (TRK)

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Transcription:

Installation guide Philips EvoKit LED 2x4 and 2x2 This installation guide is only valid for the following Philips EvoKit models: Products 2x4 EvoKit 2x4 P 36L 36W 835 2 0-0 7 G2 EvoKit 2x4 P 36L 36W 840 2 0-0 7 G2 EvoKit 2x4 P 36L 34W 835 Mk0 7 G2 EvoKit 2x4 P 36L 34W 840 Mk0 7 G2 EvoKit 2x4 P 36L 33W 835 5 Mk0 7 G2 EvoKit 2x4 P 36L 33W 840 5 Mk0 7 G2 EvoKit 2x4 P 36L 34W 830 Mk0 7 G2 EvoKit 2x4 P 36L 33W 830 5 Mk0 7 G2 EvoKit 2x4 P 36L 36W 830 2 0-0 7 G2 EvoKit 2x4 P 42L 39W 835 2 0-0 7 G2 EvoKit 2x4 P 42L 39W 840 2 0-0 7 G2 EvoKit 2x4 P 42L 40W 835 Mk0 7 G2 EvoKit 2x4 P 42L 40W 840 Mk0 7 G2 EvoKit 2x4 P 42L 42W 835 5 Mk0 7 G2 EvoKit 2x4 P 42L 42W 840 5 Mk0 7 G2 EvoKit 2x4 P 42L 40W 830 Mk0 7 G2 EvoKit 2x4 P 42L 42W 830 5 Mk0 7 G2 EvoKit 2x4 P 42L 39W 830 2 0-0 7 G2 EvoKit 2x4 P 52L 5W 835 2 0-0 5 G2 EvoKit 2x4 P 52L 5W 840 2 0-0 5 G2 EvoKit 2x4 P 52L 52W 835 Mk0 5 G2 EvoKit 2x4 P 52L 52W 840 Mk0 5 G2 EvoKit 2x4 P 52L 53W 835 5 Mk0 5 G2 EvoKit 2x4 P 52L 53W 840 5 Mk0 5 G2 EvoKit 2x4 P 52L 52W 830 Mk0 5 G2 EvoKit 2x4 P 52L 53W 830 5 Mk0 5 G2 EvoKit 2x4 P 52L 5W 830 2 0-0 5 G2 Products 2x2 EvoKit 2x2 P 23L 23W 835 2 0-0 7 G2 EvoKit 2x2 P 23L 23W 840 2 0-0 7 G2 EvoKit 2x2 P 23L 23W 835 Mk0 7 G2 EvoKit 2x2 P 23L 23W 840 Mk0 7 G2 EvoKit 2x2 P 23L 25W 835 5 Mk0 7 G2 EvoKit 2x2 P 23L 25W 840 5 Mk0 7 G2 EvoKit 2x2 P 23L 23W 830 Mk0 7 G2 EvoKit 2x2 P 23L 25W 830 5 Mk0 7 G2 EvoKit 2x2 P 23L 23W 830 2 0-0 7 G2 EvoKit 2x2 P 32L 3W 835 2 0-0 7 G2 EvoKit 2x2 P 32L 3W 840 2 0-0 7 G2 EvoKit 2x2 P 32L 32W 835 Mk0 7 G2 EvoKit 2x2 P 32L 32W 840 Mk0 7 G2 EvoKit 2x2 P 32L 34W 835 5 Mk0 7 G2 EvoKit 2x2 P 32L 34W 840 5 Mk0 7 G2 EvoKit 2x2 P 32L 32W 830 Mk0 7 G2 EvoKit 2x2 P 32L 34W 830 5 Mk0 7 G2 EvoKit 2x2 P 32L 3W 830 2 0-0 7 G2

FAILURE TO FOLLOW THESE INSTRUCTIONS AND S MAY RESULT IN SERIOUS INJURY OR SIGNIFICANT PROPERTY DAMAGE. For your protection, carefully read these warnings and instructions in their entirety before installing or maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand these instructions or if additional information is required, contact your local Philips representative. Retain these instructions for maintenance reference. The EvoKit must be installed and maintained by a professional electrician in accordance with the applicable federal, state and local laws, regulations and electrical codes, and the installation instructions provided in this document. This professional should be familiar with the construction and operation of this product and any hazards involved. If not qualified, do not attempt installation. Contact a qualified electrician. RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY Do not install in a damaged fixture. Install the EvoKit only in NEMA type G or Type NFG t-grids with a minimum troffer depth of 3. efore installation, turn power off. This equipment may have sharp edges. Wear gloves to prevent cuts or abrasions when removing from carton, handling and maintaining this equipment. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. Caution This kit is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. Caution Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation except if specifically mentioned in these installation guide. Do not use abrasive materials, glass cleaners or other solvents on cover plate or lens. To clean the faceplate, use a mild soap solution. Do not expose the product to substances and /or materials containing sulphur, chlorine or other halogen compounds and to chemicals mentioned in below table. Category Solvents Handle components with care. Do not drop, slide or scratch any of the components to prevent visual damage to the product, loss of functionality or difficulties during installation. Chemical Name Toluene, xylene, benzene, chloromethane, chloroform, ethyl acetate, butyl acetate, acetone, MEK, MIK Acid HCl, H 2 SO 4, HNO 3 Alkali KOH, NaOH, LiOH, Ca(OH) 2 Oil Diesel oil, petroleum, hydro carbons Host lighting fixture The Philips EvoKit is designed for installation in a wide variety of 2x4 and 2x2 indoor fluorescent based fixtures in horizontal applications. The Philips EvoKit is non-air handling. Install the Philips EvoKit only in fluorescent based host lighting fixtures only with a minimum depth of 3. Install the Philips EvoKit only in combination with 5/6 NEMA G or NEMA NFG t-grids. Due to the wide variety in troffers and ceiling grids, it is recommended that the installer does a test install before commencing a renovation. Please verify voltage on the Philips EvoKit product label matches the mains voltage. 2

Installation Philips EvoKit 2x4 and 2x2 Set contains Tools required C D A 2x E RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY A Side Panel LED Panel C Troffer Label D Closing Panel E Diffuser efore installation, turn power off. Remove host fixture contents. Turn power off and take out original cover. 2. Take out TL tubes. 3. Remove belly pan. If remaining troffer height is limited, remove ballast. 4. Disconnect host fixture ballast from mains. Make sure to remove packaging (except the LED protection*), from EvoKit components before installing. Do not install with total power input greater than power rating of original fixture. When space in the troffer is limited, remove original ballast. * Remove LED protection just before installing the Diffuser (E) (see step 4). Installation of Side Panels (A) A A 5. Install Side panels (A) in-between troffer and T-grid. 6. Slide Side Panel (A) outwards as far as possible. 3

Installation Philips odine SL30 (Optional) For installation of the Philips odine SL30 Emergency LED Driver, please see the emergency driver installation section from this EvoKit manual Installation LED Panel () DO NOT TOUCH LED 2 Installation Troffer Label (C) 7. Install LED panel () in between troffer and T-grid, making sure the tabs at each corner of the LED panel slide into the respective slots on the side panel. ATTENTION ESD SENSITIVE 90 o 8. Push LED panel upward into position so that the tabs sits above the side panels (this may require a push up on the tabs while pushing outward on the side panels). Fixate panels and establish by turning each fastener 90 degrees. While installing the LED panel () and Closing Panel (D), make sure the electrical wiring is not clamped between panels. Do not touch the LEDs with hands or tooling! Touching LEDs can lead to failure of the product. C THIS LUMINAIRE HAS EEN MODIFIED FROM ITS ORIGINAL CONFIGURATION. THIS LUMINAIRE WILL NO LONGER ACCEPT THE ORIGINAL LAMPS STATED ON THE RELAMP LAEL. CE LUMINAIRE A SUI DES MODIFICATIONS PAR RAPPORT À SA CONFIGURATION D ORIGINE. CE LUMINAIRE N ACCEPTERA PLUS LES AMPOULES PRÉVUES À L ORIGINE ET REPRISE SUR L ÉTIQUETTE RELATIVE AU REMPLACEMENT. THIS LUMINAIRE HAS EEN MODIFIED FROM ITS ORIGINAL CONFIGURATION. THIS LUMINAIRE WILL NO LONGER ACCEPT THE ORIGINAL LAMPS STATED ON THE RELAMP LAEL. CE LUMINAIRE A SUI DES MODIFICATIONS PAR RAPPORT À SA CONFIGURATION D ORIGINE. CE LUMINAIRE N ACCEPTERA PLUS LES AMPOULES PRÉVUES À L ORIGINE ET REPRISE SUR L ÉTIQUETTE RELATIVE AU REMPLACEMENT. It is imperative to use the retrofit warning sticker included with the product in order to alert the end user that this luminaire will no longer operate on the originally intended lamps. 9. Place Troffer Label (C) inside original troffer. Ground connection (Situation - 2) Proper ing of EvoKit metal parts is required to ensure personal safety. Make new electrical connections to mains by employing applicable connectors in accordance with the applicable federal, state and local laws, regulations and electrical codes. 0a. Situation Grounding: Screw ing cable from Led Panel () to original troffer if host fixture connection is made trough host fixture. 0b. Situation 2 Grounding: Connect to the incoming lead from conduit. 4

Mains connection mains. Connect main cables and hide connected wires behind LED Panel (). Installation Closing Panel (D) D 2 90 o While installing the LED panel () and Closing Panel (D), make sure the electrical wiring is not clamped between panels. 2. Install Closing Panel (D) in-between troffer and T-grid. 3. Fixate panels and establish by turning each fastener 90 degrees. Remove LED protection Installation Diffuser (E) LED PROTECTION 4. Tear off LED protection. E 5. Slide Diffuser (E) under the tabs on one side from either Panel and press diffuser (E) over the tabs on opposite panel. Connection 0-0V and MK0 dimmer (Optional) EvoKit 0-0V wiring diagram EvoKit MK0 wiring diagram Use 8 AWG Solid Copper Wire Rated>=300V. Strip Wire 3/8 0-0V DIM+ DIM- } Class Wiring or Class 2 Circuit 0-0VDC Dimmer LINE 2 NEUTRAL MK 0 20V / 277V In case the EvoKit MK0 277V is installed in combination with a dimmer, use a minimum of 2 EvoKits MK0 277V per dimmer. 6a. Optional: For connection EvoKit 0-0V input, use indicated connections on the driver. 6b Optional: For connection a dimmer to the EvoKit Mark 0, use indicated connections on the driver. 5

Initial installation Philips odine SL30 Emergency LED driver (Sold separately) If the Philips odine SL30 Emergency LED Driver is to be installed into the EvoKit retrofit fixture, please follow these instructions and the instructions provided with the Emergency driver. W 2x Z W 2x X Y X Ensure all warning and cautionary markings given in the Philips odine SL30 installation instructions are heeded. Components: Screws (W), Emergency LED driver (X), Test switch (Y) Wiring harnass (Z). 5 mm. Secure SL30 (X) to the back side of LED Panel () using two screws (W). Y violet Ensure an un-switched hot circuit is available to the fixture. This is required for proper emergency fixture operation. max. 2. Drill /2 hole in the LED Panel () for installation of LED/test switch on indicated area. brown 3. Install the test switch by feeding the violet and brown wires through this /2 hole and hand tighten the plastic nut included with the test switch/led combo. Add connect from test switch to wiring harnass (Z) (violet - violet, brown - brown). yellow / black red/white black blue/white yellow white red/white SL30 blue 4. Disconnect the red/white single wire from the EvoKit driver. Replace it with the blue output wire from the SL30 (Z). Place a wire nut over the original red/white wire for proper isolation. CONVERTER CONNECTOR WALL SWITCH HOT COMMON RED RED WHT/RED LACK WHITE WHT/LK 5. Connect the yellow output wire from the SL30 to the EvoKit blue/white wire connection block and the yellow/black output wire from the SL30 (Z) to the EvoKit red/white wire connection block. JUMPER WIRE LOAD SELECT Emergency LED Driver 6. Disconnect black wire and insert white/black wire (Z) in the EvoKit driver. 7. Connect WHT/RED, LACK and WHITE (2x) wires (Z) as per the SL30 wiring diagram. Connect the SL30 red to red as indicated in schematic (Z). LACK WHITE AC DRIVER For the EVOkit, do not connect the jumper wire / load select (yellow/red) on SL30. 203 Philips Lighting Company. A Division of Philips Electronics North America Corporation. All rights reserved. Printed in USA 8/3 www.philips.com Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873-800-555-0050 44352906085 Philips Lighting 28 Hilmont Road Markham, Ontario Canada, L6C 253-800-555-0050 A Division of Philips Electronics Ltd. 6