technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

Similar documents
technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FTXS-G

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

w w w. d a i k i n. e u ATXS-E

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Daikin air conditioners for your home

Daikin air conditioners for your home

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

for your home FLXS-B Flexi type unit air to air heat pumps

Daikin air conditioners for your home

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

for your home FTYN-GX FT(Y)N-F

BENEFIT FROM LOWER FUEL COSTS.

AIR CONDITIONERS, HEATING & COOLING for your home

for your home FTXS-G WALL MOUNTED UNIT

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air conditioners, heating & cooling for the retailmarket and offices

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Air Conditioners Technical Data

Air conditioners, heating & cooling for shops,restaurants and offices

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Air Conditioners Technical Data

technical data air conditioning systems Indoor Units FBQ-C7VEB

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data EEDEN RXS-F8

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FBQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Ceiling Suspended Unit

Daikin air conditioners for your home, shops, restaurants and offices

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

EDUS Heat Pump - D-Series

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN AZQS-BV1

Daikin air conditioners for shops, restaurant and offices

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

EEDEN technical data EKRTR. Altherma. Altherma

Air Conditioners. Technical Data FTY-H

technical data air conditioning systems Indoor Units FCQ-C8VEB

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

for the retail market, hotels, restaurants and offices

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioners Technical Data

SiUS041638E. Service Manual. Inverter Pair Wall Mounted Type FTX-N Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Remote control infrared ARC433B76 ARC433A8 ARC433B69

2. Pictographs 2.1 Basic Operation

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

for small rooms in multi application

DESIGN & TECHNICAL MANUAL

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

Air Conditioners Technical Data

URURU SARARA. Total. comfort solution

Air Conditioners. Technical Data RZQG-L

Service Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SHOPS, RESTA URA NTS, OFFICES, HOTELS,

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S

SiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Air Conditioning Technical Data RZASG-MV1

EEDEN technical data ERHQ AA. Altherma. Altherma

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Heating & Cooling

TABLE OF CONTENTS RMXS-E8V1B

Pure comfort & design

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

where innovation meets creativity

Daikin air conditioners for shops, restaurants and offices

Pure comfort & design

Air Conditioning Technical Data RZAG-MV1

DESIGN & TECHNICAL MANUAL

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Pure comfort & design

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Purifiers. Technical Data MC70L

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

PCR0709A. Options. Indoor unit

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

technical data air conditioning systems RZQ B8W1B Split Sky Air

DESIGN & TECHNICAL MANUAL

Transcription:

technical data FT(Y)S-B Wall Mounted Unit air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE03-/2 03/2003 Prepared in Belgium by Goekint Graphics

TABLE OF CONTENTS FT(Y)S-B Features... 2 2 Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications 3 Dimensional drawings... 7 4 Piping diagrams... 9 5 Wiring diagrams... 0 6 Sound level... 2 Sound level data Sound pressure spectrum 7 Accessories... 6 Standard accessories Optional accessories 8 Control systems... 7 9 Center of gravity... 9 0 Installation... 20 For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor units

Features + Lightweight and compact + Extremely quiet in operation both indoors and outdoors + Automatic air flow director ensures uniform air flow and temperature distribution + Powerful mode can be selected for rapid cooling or heating. + Air purification filter - deodorises the air - helps to prevent bacterial and viral propagation + Photocatalytic deodorising air filter: - powerful decomposes cigarette and pet odours - removes house dust and pollen - deactivates bacteria and viruses + Washable front panel + The outdoor unit can easily be mounted on a roof, a terrace or placed against an outside wall. + The remote control has a 24 hour timer + The indoor model also has a start/stop button mounted on the front panel + Up to 5 indoor units can be operated from a single centralised control + Purpose designed holder provided for your remote control 2 3 0 q 7 x Standard Optional 50,60 class only 8 6 0 6 4! FTYS FTS 5 steps 2 Split - Sky Air Indoor units

2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB NOMINAL INPUT Cooling Nominal kw 0.040 0.040 0.040 0.040 0.040 2 For combination indoor + outdoor units (air cooled): INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB OUTDOOR UNITS RS20BVMB RS25BVMB RS35BVMB RS50BVMB RS60BVMB NOMINAL CAPACITY (2-3) Cooling () Nominal kw 2.00 2.50 3.5 5.00 6.00 NOMINAL INPUT Cooling Nominal kw 0.69 0.89.2.66 2.2 EER 2.90 2.8 2.8 3.0 2.83 ENERGY LABEL Cooling C C C B C ANNUAL ENERGY CONSUMPTION Cooling kwh 345 445 560 830,060 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB DIMENSIONS Unit H mm 273 290 290 W mm 784 795,050 D mm 85 230 230 WEIGHT Unit kg 7.5 9 2 COLOUR Unit White SOUND LEVEL Sound pressure (cooling) (4) high db(a) 38 39 39 44 45 low db(a) 26 27 27 35 36 Sound power (cooling) (5) high db(a) 54 55 55 63 63 FAN Air flow rate (cooling) high m 3 /min 7.5 7.8 8.0.5 6.4 low m 3 /min 3.9 4.2 4.5 8.3.6 Speed steps 5 steps, silent and auto high rpm,260,300,330,330,320 medium rpm,05,055,090,60,60 low rpm 770 80 850 980,000 Type Cross flow fan Motor output W 8 40 HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 6 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microprocessor control PIPING CONNECTIONS liquid mm J 6.4 gas mm J 9.5 J 2.7 drain mm J 8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RS-B Split - Sky Air Indoor units 3

2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB CURRENT Nominal running current cooling A 0.8 0.8 0.8 0.8 0.8 Maximum running current cooling A See chapter RS-B: electrical data For combination indoor units + outdoor units: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB RS20BVMB RS25BVMB RS35BVMB RS50BVMB RS60BVMB CURRENT Nominal running current cooling A 3.4 4.5 6.0 7.3 9.3 Maximum running current cooling A Starting current cooling A See chapter RS-B: electrical data For indoor units only: FTS20BVMB FTS25BVMB FTS35BVMB FTS50BVMB FTS60BVMB POWER SUPPLY VM VM VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz 50 50 50 50 50 Voltage V 230 230 230 230 230 NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 3 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 4 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 4 Split - Sky Air Indoor units

2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB NOMINAL INPUT Cooling Nominal kw 0.040 0.040 0.040 0.040 0.040 Heating Nominal kw 0.040 0.040 0.040 0.040 0.040 2 For combination indoor + outdoor units (air cooled): INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB OUTDOOR UNITS RYS20BVMB RYS25BVMB RYS35BVMB RYS50BVMB RYS60BVMB NOMINAL CAPACITY (3-4) Cooling () Nominal kw 2.00 2.50 3.5 5.00 6.00 Heating (2) Nominal kw 2.60 3.30 4.0 5.80 7.00 NOMINAL INPUT Cooling Nominal kw 0.69 0.89.2.66 2.2 Heating Nominal kw 0.805.025.345.70 2.09 EER Cooling 2.90 2.8 2.8 3.0 2.83 Heating 3.23 3.22 3.05 3.4 3.35 ENERGY LABEL Cooling C C C B C Heating C C D B C ANNUAL ENERGY CONSUMPTION Cooling kwh 345 445 560 830,060 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB DIMENSIONS Unit H mm 273 290 290 W mm 784 795,050 D mm 85 230 230 WEIGHT Unit kg 7.5 9 2 COLOUR Unit White SOUND LEVEL Sound pressure high db(a) 38/38 39/39 39/39 44/42 45/44 (cooling/heating) (5) low db(a) 26/26 27/27 27/27 35/* 36/* Sound power (cooling/heating) high db(a) 54/54 55/* 55/* 63/60 63/62 (6) FAN Air flow rate high m 3 /min 7.5/7.6 7.8/7.9 8.0/7.9.5/2.2 6.4/7.5 (cooling/heating) low m 3 /min 3.9/5.0 4.2/5.3 4.5/5.4 8.3/8.8.6/2.8 Speed (cooling/heating) steps 5 steps, silent and auto high rpm,260/,220,300/,260,330/,260,330/,370,320/,330 medium rpm,05/,050,055/,090,090/,00,60/,90,60/,80 low rpm 770/880 80/920 850/940 980/,000,000/,020 Type Cross flow fan Motor output W 8 40 43 HEAT EXCHANGER Type ML fin - J7Hi - XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 2 x.4 2 x 2 x.4 2 x 6 x.4 2 x 6 x.4 AIR FILTER Removable/washable/mildew proof TEMPERATURE CONTROL Microprocessor control PIPING CONNECTIONS liquid mm φ6.4 gas mm φ9.5 φ2.7 drain mm φ8.0 INSULATION MATERIAL Heat insulation tape Both liquid and gas pipes For outdoor units Pair application See chapter RYS-B Split - Sky Air Indoor units 5

2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB CURRENT Nominal running current cooling A 0.8 0.8 0.8 0.8 0.8 heating A 0.8 0.8 0.8 0.8 0.8 Maximum running current cooling A heating A See chapter RXS-B: electrical data For combination indoor units + outdoor units: FTYS20BVMB FTYS25BVMB FTY3S5BVMB FTYS50BVMB FTYS60BVMB RYS20BVMB RYS25BVMB RYS35BVMB RYS50BVMB RYS60BVMB CURRENT Nominal running current cooling A 3.4 4.5 6.0 7.3 9.3 heating A 4. 5.0 6.9 7.5 9.2 Maximum running current cooling A heating A Starting current cooling A See chapter RYS-B: electrical data heating A For indoor units only: FTYS20BVMB FTYS25BVMB FTYS35BVMB FTYS50BVMB FTYS60BVMB POWER SUPPLY VM VM VM VM VM NOMINAL DISTRIBUTION SYSTEM Phase VOLTAGE Frequency Hz 50 50 50 50 50 Voltage V 230 230 230 230 230 NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature 20 CDB * outdoor temperature 7 CDB/6 CWB * refrigerant piping length 7.5m (horizontal) * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods. 5 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this chapter. 6 The sound power level is an absolute value indicating the power which a sound source generates. 7 Energy label: scale from A (most efficient) to G (less efficient). 8 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions) 6 Split - Sky Air Indoor units

3 Dimensional drawings FT(Y)S20-25-35B The mark (Y) shows piping direction Rear Air flow (indoor) required space (for performance and maintenance) unit (mm) 3 Left Right (including installation plate) (space for performance) (space for maintenance) (space for maintenance) Home leave lamp Name plate Signal receiver Room temp. thermistor Terminal block with earth terminal Bottom Front grille fixing screws (Inside) Flaps Signal transmitter Intelligent eye sensor Timer lamp Operation lamp Indoor unit ON/OFF switch Gas pipe 9.5Cut (The length of pipe outside the unit: about 300) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) (The hose length on the outside of the unit is approx. 40) Blade angle Up/down (automatic) Cooling, dry Heating Infrared remote control Right/left (manual) Wall hole for embedded piping J 65 hole Wall hole J 65 hole FTYS--: (ARC433A27) FTS--: (ARC433A24) Standard locations of wall holes 3D038629 FT(Y)S50B The mark (Y) shows piping direction Air flow (indoor) required space (for performance and maintenance) unit (mm) Left Rear Rear Right (including installation plate) (space for performance) (space for maintenance) Name plate Required space (space for maintenance) Bottom Flaps Front grille fixing screws (Inside) Signal transmitter Signal receiver Indoor unit ON/OFF switch Intelligent eye sensor Room temp. thermistor Timer lamp Home leave lamp Horizontal blade (Automatic) Cooling, dry Operation lamp Blade angles Heating (FTX -- only) Dry Terminal block with earth terminal (Inside) Gas pipe 2.7Cut (The length of pipe outside the unit: about 340) Liquid pipe J6.4 CuT (the length of pipe outside the unit: about 350) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Infrared remote control FTYS---: (ARC433A23) FTS---: (ARC433A24) Vertical blade (Automatic) Wall hole for embedded piping J 65 hole Standard locations of wall holes Wall hole J 65 hole 3D040072 Split - Sky Air Indoor units 7

3 Dimensional drawings 3 FT(Y)S60B Air flow (indoor) required space (for performance and maintenance) unit (mm) The mark (Y) shows piping direction Rear Left Rear Right (space for maintenance) (space for performance) (including installation plate) Required space (space for maintenance) Bottom Flaps Front grille fixing screws (Inside) Signal transmitter Horizontal blade (Automatic) Cooling Operation lamp Signal receiver Intelligent eye sensor Timer lamp Home leave lamp A FTX(K)S60 7-- 6.4 Blade angle Indoor unit ON/OFF switch Room temp. thermistor Heating (FTX -- only) Dry FTX(K)S60-- FTX(K)S7-- Name plate Terminal block with earth terminal B 2.7 Gas pipe J B Cut (The length of pipe outside the unit: about 340) Liquid pipe J A Cut (The length of pipe outside the unit: about 390) Drain hose (connecting part I.D. J 4.0, O.D. J 8.0) (The hose length on the outside of the unit is approx. 440) Vertical blade (Automatic) Infrared remote control Wall hole for embedded piping J 80 hole Wall hole J 80 hole FTYS---: (ARC433A23) FTS---: (ARC433A24) Standard locations of wall holes 3D040080 8 Split - Sky Air Indoor units

4 Piping diagrams FT(Y)S20-25-35B Indoor unit 4 Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Fan motor Field piping Refrigerant flow Cooling Heating 4D033698A FT(Y)S50-60B Indoor unit Heat exchanger Thermistor on heat exchanger Field piping Cross flow fan Field piping Fan motor Refrigerant flow Cooling Heating 4D04008 Split - Sky Air Indoor units 9

5 Wiring diagrams 5 FT(Y)S20-25-35B (Terminal for centralised control) Transmission circuit g Field wiring Outdoor CAUTION Signal receiver Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Indoor R C70 FU HP H3P MF MS PCB PCB3 RT, R2T S S36 SW XM : Protective earth : Running capacitor : Fuse : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038629 FT(Y)S50B g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038466A 0 Split - Sky Air Indoor units

5 Wiring diagrams FT(Y)S60B 5 g Field wiring Rectifier Outdoor Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Infrared remote control Signal receiver Indoor R FG FU H H3 HP H3P MF MS, M2S PCB PCB5 RT, R2T S S38 SW XM : Protective earth : Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip 3D038532A Split - Sky Air Indoor units

6 Sound level 6 6-6- Sound level data Cooling only Sound pressure level Model 230V, 50Hz Sound power level Cooling Measuring location (Cooling) H L FTS25B 38 26 Location of microphone 54 FTS25B 39 27 55 FTS35B 39 27 55 FTS50B 44 35 63 FTS60B 45 36 63 Heat pump Sound pressure level Model 230V, 50Hz Sound power level Cooling/Heating Measuring location (Cooling/Heating) H L FTYS20B 38/38 26/26 Location of microphone 54/54 FTYS25B 39/39 27/27 55/* FTYS35B 39/39 27/27 55/* FTYS50B 44/42 35/* 63/60 FTYS60B 45/44 36/* 63/62 * This information was not available at the time of publication. 2 Split - Sky Air Indoor units

6 Sound level 6-2 Sound pressure spectrum Cooling only FTS20B FTS25-35B 6 6-2 4D038643 4D038648 FTS50B FTS60B 4D040303 4D040304 NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz 220-240/220-230V(H) 50/60Hz 220-240/220-230V(L) Split - Sky Air Indoor units 3

6 Sound level 6 6-2 6-2 Sound pressure spectrum Heat pump FTYS20B (Cooling) FTYS20B (Heating) 3D038650 3D038650 FTYS25-35B (Cooling) FTYS25-35B (Heating) 3D03865 3D03865 NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz 220-240/220-230V(H) 50/60Hz 220-240/220-230V(L) 4 Split - Sky Air Indoor units

6 Sound level 6-2 Sound pressure spectrum FTYS50B (Cooling) FTYS50B (Heating) 6 6-2 3D040299 3D040299 FTYS60B (Cooling) FTYS60B (Heating) 3D040300 3D040300 NOTE Operation differs with operation and ambient conditions. Legend 50/60Hz 220-240/220-230V(H) 50/60Hz 220-240/220-230V(L) Split - Sky Air Indoor units 5

7 Accessories 7 7-7- Standard accessories FT(Y)S20-25-35B ja Mounting plate je Remote control holder jk Operation manual jc Air purification filter 2 jg AAA dry-cell batteries 2 jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L 2 FT(Y)S50-60B ja Mounting plate je Remote control holder jk Operation manual 2 jb Air purification filter with photocatalytic deodorising function 2 jg AAA dry-cell batteries jl Installation manual jd Infrared remote control jh Indoor unit fixing screws M4x2L 2 7-2 Optional accessories FT(Y)S-B Option name 20 25 35 50 60 Wiring adapter for time clock / remote control () Normal open contact KRP43AS Normal open pulse contact KRP43AS Centralised control board up to 5 rooms (2) KRC72 Central remote control DCS302B5 Unified ON/OFF control DCS30B5 Scheduletimer DST30B5 Interface adapter (3) KRP928A2S Air purification filter with frame KAF925B4 Air purification filter without frame KAF925B42 Air purification filter, with deodorising filter KAF952A42 Anti-theft protection for remote control KKF90A4 () Wiring adapter is also required for each indoor unit. (2) Wiring adapter supplied by Daikin. Time clock and other devices: field supply. (3) For DIII-NET adapter 6 Split - Sky Air Indoor units

8 Control systems 8- Infrared remote control FT(Y)S20-25-35B 8 8-2 C ON 3 6 HOME LEAVE POWERFUL MODE SILENT TEMP FAN ON/OFF SWING SENSOR 4 5 7 8 9 ON CANCEL 2 OFF TIMER 3 0 <ARC433A24, A27> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 POWERFUL button: for POWERFUL operation 4 TEMPERATURE adjustment buttons: It changes the temperature setting 5 ON/OFF button: Press this button once to start operation. Press once again to stop it. 6 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 7 FAN setting button: It selects the air flow rate setting. 8 SWING button 9 ON TIMER button 0 OFF TIMER button TIMER setting button: It changes the time setting 2 TIMER CANCEL button: It cancels the timer setting. 3 CLOCK button Split - Sky Air Indoor units 7

8 Control systems 8 8-8- Infrared remote control FT(Y)S50-60B 2 C ON 3 POWERFUL TEMP ON/OFF 6 MODE FAN SWING 4 5 7 8 9 ON OFF TIMER CANCEL 2 3 0 <ARC433A23, A24> Signal transmitter: It sends signals to the indoor unit. 2 Display: It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3 POWERFUL button: for POWERFUL operation 4 TEMPERATURE adjustment buttons: It changes the temperature setting 5 ON/OFF button: Press this button once to start operation. Press once again to stop it. 6 MODE selector button: It selects the operation mode (Auto, /DryI / Cool u / Heat w / Fan B) 7 FAN setting button: It selects the air flow rate setting. 8 SWING button Flap (horizontal blade) 9 ON TIMER button 0 OFF TIMER button TIMER setting button: It changes the time setting 2 TIMER CANCEL button: It cancels the timer setting. 3 CLOCK button 8 Split - Sky Air Indoor units

9 Center of gravity FT(Y)S20-25-35B 9 4D020686E FT(Y)S50B 4D04032 FT(Y)S60B 4D04033 Split - Sky Air Indoor units 9

0 Installation 0 FT(Y)S20-25-35B Indoor unit installation drawings ja Mounting plate How to attach the indoor unit. Hook the claws of the bottom frame to the mounting plate. If the claws are difficult to hook, remove the front panel. How to remove the indoor unit. Push up the marked area (at the lower part of the front panel) to release the claws. If it is difficult to release, remove the front panel. Front panel Bottom frame Mounting plate Clip Mark (rear side) M4 x 25L The mounting plate should be installed on a wall which can support the weight of the indoor unit. 30mm or more from ceiling Caulk pipe hole gap with putty. Front grille 50 mm or more from walls (on both side) Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. Air filters Appearance of the indoor unit may differ from some models. Service lid This service lid is an open/close type. + Remove the screws on the service lid. + Slide the service lid leftward. + Rotate the service lid upward. jc Air purification filters Install air purification filter on air filter jc Air purification filter Air filter jd Infrared remote controller Before screwing the remote control holder to the wall, make sure that control signals are properly received by indoor unit. je Remote control holder (M3 x 20L) 20 Split - Sky Air Indoor units

0 Installation FT(Y)S50-60B Indoor unit installation drawings 0 ja Mounting plate M4 x 25L The mounting plate should be installed on a wall which can support the weight of the indoor unit. The figure shows a 50 class unit. (See Indoor Unit Installation. Installing the mounting plate for details regarding 60 and 7 class units.) Front grille 30mm or more from ceiling Caulk pipe hole gap with putty. Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe s cut line. 50 mm or more from walls (on both side) Wrap the installation pipe with the finishing tape from bottom to top Air filters Only for 60 class units. jb Air purification filter with photocatalytic deodorising function 50 class Tabs (upper 3 locations) Service lid Opening service lid Service lid is opening/closing type. Opening method ) Remove the service lid screws. 2) Lift the service lid upward. Tabs (lower 2 locations) 60 class Tabs (upper 3 locations) Tabs (lower 3 locations) Insert the upper side of the jb Air purification filter with photocatalytic deodorising function into the tabs (upper 3 locations), push the lower side of the filters up a little and into the tabs (lower 2 locations) (lower 3 locations). Split - Sky Air Indoor units 2