ООО "ТИ-СИСТЕМС" Overhead Water Tank Solutions (ISTEC Type ESW-OWT) Cable Heated Insulated Solutions (ISTEC Type ES/ESW-ICH)

Similar documents
Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

EMERGENCY SHOWERS AND EYEWASHES

Emergency Showers & Eye Wash Stations

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

8200 Combination Units

PRODUCT CATALOGUE. We ensure safety in risky environments.

also CE marked in accordance with relevant EC (European Community) directives. The development of this advanced range of emergency products has

hazards introduction combating contents combating hazards EYEBATH & EYE/FACEWASH EQUIPMENT UNHEATED EMERGENCY SHOWERS SELF-DRAINING EMERGENCY SHOWERS

7000BT Eye/Face Washes

Eyewash and Eye/Face Wash units that are either wall mounted or pedestal mounted. 7260B B 7270B

TEMPERED WATER. Solutions for Safety Showers

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

EMERGENCY EQUIPMENT AXION MSR TM EYE WASH :: EYE/FACE WASH SHOWERS :: COMBINATION UNITS

SHOWER, EYEWASH & FACEWASH PRODUCTS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

TOP 15 :: EMERGENCY EQUIPMENT

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

SHOWER, EYEWASH & FACEWASH PRODUCTS

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

A. This Section includes the following emergency plumbing fixtures:

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

PRODUCT CATALOGUE. We ensure safety in risky environments.

Emergency Response Procedures

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

EMERGENCY DRENCH SHOWER

Table of Contents ICON KEY. Quick ship icon indicates product is available for shipment within 48 hours for quantities of 4 pieces or less.

Tepid Water Delivery System

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE PRODUCTS EYE/FACE WASH :: SHOWERS COMBINATION UNITS

SA gal, 6 min. Flush (Eng. inst.) 19 SAM gal, 6 min. Flush (Fr. inst.) 19

REPLACEMENT PARTS MANUAL

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE EYE/FACE WASH :: SHOWERS COMBINATION UNITS PRODUCTS

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Twin-Agent Fire Fighting/Securing Systems Specifications

Automatic Temperature Controller (ATC)

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

- Hand Held Eye Showers & Accessories. - Heated Emergency Showers & Eye Washes EMERGENCY SHOWER SYSTEMS

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Safety Scenarios. You enter the lab and discover that you will be boiling water in a beaker and pouring the hot water into a separate container.

THE TINY LIGHTWEIGHT

Firefighting Monitors Tunnels Fire Protection Systems. Integrated Fire Safety and Security Solutions

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE EYE/FACE WASH :: SHOWERS COMBINATION UNITS PRODUCTS

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

HEATING WATER FOR OVER 50 YEARS

ECONOMICAL, EFFICIENT PERFORMANCE

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Model 7500EB Portable Eyewash with Heater

CLE SERIES Fluid heating for emergency eyewash stations

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number F-2.0 Emergency Eyewash / Emergency Showers

G1100 EyeSafe Faucet-Mounted Eyewash, Adjustable Aerated Outlet Heads

Installation and Operation Guide

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Emergency Fixtures NEW. pg 55. Custom Emergency Signaling Systems BRADLEYCORP.COM

Requirements for the Design and Construction of

Design Manual... BROEN-LAB EMERGENCY SHOWER SYSTEMS EMERGENCY SHOWER SYSTEMS NEW MODELS. How to market the red dot.

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

NFPA 96, 2017 REVIEW SUMMARY

VWR symphony CO 2 INCUBATORS

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Emergency Eye Wash/Shower

Installation, Operation and Maintenance Instructions

WHITE PAPER: EMERGENCY SHOWER and EYEWASH RECIRCULATING LOOP SYSTEMS GENERAL CONSIDERATIONS

Laboratories and Hazardous Materials. Company Overview

YanCheng STG Safety Equipment Co.,Ltd 1

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

Chapter 3: Emergency Planning for Laboratories

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

EMERGENCY EYEWASH AND SHOWER

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

DUKE UNIVERSITY CONSTRUCTION STANDARDS

SPEAKMAN SPEAKMAN SPECIFICATIONS

Technology for life. Unit heater LH

Emergency Response Guide for Laboratories

WALL MOUNT AUTOPSY STATION CENTER SINK

MODEL WALL MOUNT AUTOPSY STATION DOUBLE SINK

TAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL

Repair Parts List DISHWASHER MODEL NUMBER MDB6100AWW. When requesting service or ordering parts, always provide the following information:

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

CHEMICAL FUME HOOD PROGRAM

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

General Procedures: Materials Synthesis Lab 1358 CNAM/Toll

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

PART # FOR PARTS SEE PAGE 4-2, 4-3

TEMPERING SOLUTIONS. Haws Integrated provides standardized and customized tempered water solutions for complete ANSI compliance.

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

Product Bulletin Recessed Laboratory Units

Transcription:

Cable Heated Insulated Solutions (ISTEC Type ES/ESW-ICH) Cubicle Cabins (ISTEC Type ESW-CCM) Decontamination Units (ISTEC Type DEC) verhead Water Tank Solutions (ISTEC Type ESW-WT)... y t e f a S o T d Dedicate Mobile Showers with Trail (ISTEC Type ESW-MSS) Separate Header Tanks (ISTEC Type SHT) Телефоны для связи: +7

CMPANY VERVIEW IST ISCI SAGLIGI TECHIZATI C., LTD. produces a complete range of equipment and systems for ccupational Safety Worker's Health Civil Defence Fire & CBRN & Personal Protection since 1979. Headquarters and factories are located in Ankara and two sales offices are located in Istanbul. ur operations extend around the country through our distributors. ur products are certified according to 89/686/EEC personal protection equipment directive and related harmonized European Standards. ur company has EN-IS 9001:2008 Quality System Certificate. IST Safety production includes, Emergency Showers & Eyewashes Multi-Functional Protective Clothings Fire Fighting Suits Aluminized Fire Proximity Suits Heat and Flame Protective Clothings for Industrial Purposes Protective Clothings against molten metal and aluminium splash and radiant heat Arc Flash Clothings Air Cooled Kiln Entry Suits Fire Blankets Airline Breathing Systems Safety Storage Cans & Plunger Cans To maintain our position at the forefront of protective equipment technology, we operate with the most complete and well funded R&D facilities in the safety equipment industry. IST Safety 's R&D Team continuously improves products according to EN Standards and performs product testing at our own laboratories. ARITAN, FYRPR, FYRAL, FYRTEX, ELECTPR, HEATPR, ISTAIR, ISTEC, SAFECAN and IST are our registered brands. INDEX EN 15154 & ANSI Z358.1-2009 1 REQUIREMENTS ISTEC TYPE ES/ESW-ICH CABLE HEATED, INSULATED SHWERS, EYEWASH (UTDR USE FR CLD CLIMATES) ISTEC TYPE ESW-WT 2 3 VERHEAD WATER TANK SHWERS ISTEC TYPE WT SHWER SYSTEM SELECTIN GUIDE ISTEC TYPE ESW-CCM CUBICLE CABIN MUNTED EMERGENCY SHWERS, EYEWASH ISTEC TYPE ESW-MSS MBILE SAFETY SHWERS, EYEWASH WITH TRAIL ISTEC SEPARATE HEADER TANK ISTEC TYPE DEC DECNTAMINATIN UNITS ISTEC TYPE EW-P PRTABLE EYEWASH Телефоны для связи: +7 5 6 8 8 9 9

EN 15154 REQUIREMENTS Scope Part 1 Part 2 Part 3 Part 4 Part 5 covers plumbed in body showers for use in laboratories covers plumbed in eye shower for use in all environments covers tank (non-plumbed) body showers covers tank (non-plumbed) eye/ face showers is currently in the planning phase and will cover plumbed in showers in production sites Main recommendations Flow rates Spray Pattern Test For body showers in labs the standard specifies that local standards on flow rates should apply and where no local standard is present a flow of 60 lt /minute should be used. For plumbed in eyewashes the flow rate should be minimum 6 litres per minute. In both cases the flow should be available for at least 15 minutes Spray patterns For body showers the standard recommends that at a distance of 700 mm below the shower head 50% of the water will fall within a 200 mm radius circle. 95% of the water will fall within a radius of 400 mm For eye showers the jets should reach a minimum of 100 mm from the centre of the spray head spraying directly upwards. The maximum reach for the jets should be 300 mm spraying directly upwards. Water quality and temperature The water should be of potable quality. There is not firm recommendation in the standard as to water temperature, however, there is an advisory appendix which suggests that the temperature of the water should be maintained between 15 Cº and 37 Cº Product selection implications All our emergency showers and eyewashes are built to conform to the EN 15154 standards. ANSI Z358.1-2009 REQUIREMENTS ANSI Z358.1-2004 contains provisions regarding the design, performance, installation, use and maintenance of various types of emergency equipment (showers, eye washes, drench hoses, etc.). Sections in the standard addresses how the equipment should perform, as well as testing procedures to ensure proper operation, installation, maintenance and training. Requirements for the ANSI Z358.1 Hands - free stay open valve activates in one second or less Easily located, accessible actuator no higher than 173.3 cm above floor. utlet heads shall be positioned Between 63.8 cm and 114.3 cm from the floor. Employees must be trained in the location of emergency equipment and in its proper use. Emergency equipment must be regularly maintained (including Valve actuator shall be easy to weekly activation of the equipment) to assure that it is in locate and readily accessible to working order and inspected at least annually for compliance user. with the standard. A response plan to be used in the event that an accident Hands - free stay open valve does ocur must be developed. For example; installing activates in one second or less an alarm unit with any emergency eye wash or shower unit. Emergency equipment be installed within 10 seconds Identify emergency station with walking time from the location of a hazard. highly visible sign. The water temperature delivered by emergency equipment should be tepid. For example; mixing valves to blend and temper water can be used. Disposal of the water should not create a threat. For example; drain pipings can be used. Connect unit to uninterruptible water supply capable of delivering required flow when all components are operated simultaneously Shower head shall be between 208.3 cm and 248.3 cm above floor Shower shal provide 75.7 lt of water per minute for 15 minutes At 152.4 cm above floor, the water pattern must be at least 50.8 cm in diameter Protect outlet heads from airborne contaminants Unıt must deliver at least 11.4 lt for eyewash for 15 minutes 1

ISTEC TYPE ES-ICH / ESW-ICH FREEZE PRF CABLE HEATED AND INSULATED EMERGENCY SHWER, EYEWASH (UTDR USE FR CLD CLIMATES) Protective against Freezing with cable heating (10-15 W/m, AC 230 V, Ex-Proof) and complete insulating system Suitable for extreme cold weather conditions P/N: 15026100 / 15036100 (Stainless Steel) P/N: 15026150 / 15036150 (Galvanized Steel) Push Handle Control for Eyewash, Pull Rod Control for Shower Available for hazardous and non-hazardous areas 10-15 W/m, AC 230 V, Ex-Proof Cable Heating with Insulation for freeze protection Shower Material: 304 Stainless Steel or Galvanized Steel Pipes: 1 1/4'' Stainless Steel or Galvanized Steel Shower Head and Eyewash Bowl: 300 mm diameter, Stainless Steel or Galvanized Steel Water Inlet : 1'' Water utlet: 1 1/4 '' Water Flow: Minimum 11.4 lt/min for eyewash Minimum 75.7 lt/min for shower Ex-proof Mechanical Thermostat Ex-proof or non Ex-proof Audible and Visual Alarm Scald Protection Valve Shower activation Platform Eyewash Foot Treadle verhead ABS shower Rose 316 Stainless Steel Shower Material Flow Switch Atex and Gost 2

ISTEC TYPE ESW-WT EMERGENCY SHWER AND EYEWASH VERHEAD WATER TANK (630 LT) Standard 630 lt verhead Tank Showers supply 15 minutes flow rate according to the standard requirements on the condition of being connected to mains supply that provides water in minimum 2-3 bar pressure. Different materials (Galvanized Steel, Stainless Steel, GRP ) can be used in diffrent system parts as optionally. You can customize your tank shower system by selection guide to integrate the system by choosen desired accessories and various system parts. Water Tanks are insulated. An integral immersion heater or a chiller unit can be added to the system with the options of ex-proof and non ex-proof, in order to keep the water temperature constant between 15-38 C. Heating and cooling capacities may be changed according to customer requirements. Shower Head : 300 mm diameter Eyewash Bowl: 300 mm diameter Water Inlet : 1 ½ with flange Water utlet : 1 ¼ Water Flow : Minimum 11,4 lt/min for eyewash Minimum 75,7 lt/min for shower Ex-proof r Non Ex-proof Audible And Visual Alarm Ex-proof r Non Ex-proof chiller cooling unit (for hot climates) Water Immersion Heather (for cold climates) Scald r Freeze Protection Valve Testing Lever Eyebath Foot Treadle verhead ABS Shower Rose 316 Stainless Steel Shower Material verhead Sun Canopy Low Water Level Alarm Side & Rear Panelling Spring Loaded Doors Visual Water Level Indicator Visual Water Temperature Gauge Water Low And High Tempature Alarm Drain Sump and Grating Internal or External lighting Shower activation platform Eyewash may be located internally on LHS or RHS or externally LHS or RHS when wieved in front Ex-proof space heater Ex-proof or non ex-proof flow switch Pressure regulator Stainless steel erecting lugs Thermo mixing valve Wooden Pallets M20 Electrical Box Side and rear panels insulation / Water Tank insulation Panic Bar / Push Bar Platform Activation Available in green, yellow or white color Atex and Gost Guarantees correct flow rate and 15 minutes of a tepid water supply MATERIAL Galvanized Steel Stainless Steel 304 Stainless Steel 316 GRP (Glassfiber Reinforced Plastic) verhead Water Tank (630lt 1260 lt) verhead Water Tank (ther Capacities) Emergency Shower and Eyewash Main Frame Side Panels (Cabin Walls) Drain Sump Panic Bar (Push Bar) Foot tradle for eyewash Platform Activation Grating * IST reserve the right of changıhg datas without notice. 3

ISTEC TYPE ESW-WT EMERGENCY SHWER AND EYEWASH VERHEAD WATER TANK (1260 LT) Standard 1260 lt verhead Tank Showers guarante 15 minutes of water flow according to the standard requirements in bellow circumstances; 1. Without mains (water) supply connection 2. In low water pressure 3. Interruption of flow in existing water supply connection Different materials (Galvanized Steel, Stainless Steel, GRP ) can be used in diffrent system parts as optionally. You can customize your tank shower system by selection guide to integrate the system by choosen desired accessories and various system parts. Water Tanks are insulated. An integral immersion heater or a chiller unit can be added to the system with the options of ex-proof and non ex-proof, in order to keep the water temperature constant between 15-38 C. Heating and cooling capacities may be changed according to customer requirements. Shower Head : 300 mm diameter Eyewash Bowl: 300 mm diameter Water Inlet : 1 ½ with flange Water utlet : 1 ¼ Water Flow : Minimum 11,4 lt/min for eyewash Minimum 75,7 lt/min for shower Ex-proof r Non Ex-proof Audible And Visual Alarm Ex-proof r Non Ex-proof chiller cooling unit (for hot climates) Water Immersion Heather (for cold climates) Scald r Freeze Protection Valve Testing Lever Eyebath Foot Treadle verhead ABS Shower Rose 316 Stainless Steel Shower Material verhead Sun Canopy Low Water Level Alarm Side & Rear Panelling Spring Loaded Doors Visual Water Level Indicator Visual Water Temperature Gauge Water Low And High Tempature Alarm Drain Sump and Grating Internal or External lighting Shower activation platform Eyewash may be located internally on LHS or RHS or externally LHS or RHS when wieved in front Ex-proof space heater Ex-proof or non ex-proof flow switch Pressure regulator Stainless steel erecting lugs Thermo mixing valve Wooden Pallets M20 Electrical Box Side and rear panels insulation / Water Tank insulation Panic Bar / Push Bar Platform Activation Available in green, yellow or white color Atex and Gost Guarantees correct flow rate and 15 minutes of a tepid water supply 4

ISTEC TYPE ESW-WT EMERGENCY SHWER, EYEWASH SELECTIN GUIDE Телефоны для связи: +7 (495) 7774788, -7489626, 5007154, 55, 65 CNFIGURATIN:

ISTEC TYPE ESW-CCM CUBICLE CABIN MUNTED EMERGENCY SHWER AND EYEWASH For Indoor and utdoor Applications In accordance with EN 15154-1-2 and ANSI Z358.1-2009 Available for indoor and outdoor applications Produced from galvanized steel as standard (ptionally 304 stainless steel, 316 stainless steel or GRP material) Mains Water System is recommended as 2-3 bars GRP Grating non slipping floor Testing lever Integrated drain sump Atex and Gost Guarantees correct flow rate and 15 minutes of a tepid water supply Shower Head : 300 mm diameter Eyewash Bowl: 300 mm diameter Water Inlet : 1 ½ with flange Water utlet : 1 ¼ Water Flow : Minimum 11,4 lt/min for eyewash Minimum 75,7 lt/min for shower Ex-proof r Non Ex-proof Audible And Visual Alarm Eyewash may be located internally on LHS or RHS or externally LHS or RHS when wieved in front Eyewash foot treatle Water inlet with flange connection Internal or External lighting Low water level alarm Spring loaded doors Curtain Cable heating Wooden Pallets Panic Bar / Push Bar Platform Activation Drain Sump and Grating verhead ABS Shower Rose Scald r Freeze Protection Valve Stainless steel erecting lugs Ex-proof or non ex-proof flow switch MATERIAL Cubicle Cabin Frame Side & Rear Panels Galvanized Steel S S 304 Stainless Steel 316 Stainless Steel GRP S : STANDARD : PTINAL 6

ISTEC TYPE ESW-CCM CUBICLE CABIN MUNTED EMERGENCY SHWER AND EYEWASH Insulated And Space Heated For Cold Clımates Atex and Gost Guarantees correct flow rate and 15 minutes of a tepid water supply In accordance with EN 15154-1-2 and ANSI Z358.1-2009 For outdoor applications ptions for hazardous and non-hazardous areas Applicable for ambient temperatures of - 40 C / + 55 C Insulated Cubicle (50 mm Polyuretane) Space Heater Spring activated doors Produced from galvanized steel as standard (ptionally 304 stainless steel, 316 stainless steel or GRP material) GRP Grating non slipping floor Testing lever Integrated drain sump Shower Head : 300 mm diameter Eyewash Bowl: 300 mm diameter Water Inlet : 1 ½ with flange Water utlet : 1 ¼ Water Flow : Minimum 11,4 lt/min for eyewash Minimum 75,7 lt/min for showe Ex-proof r Non Ex-proof Audible And Visual Alarm Eyewash may be located internally on LHS or RHS or externally LHS or RHS when wieved in front Eyewash foot treatle Water inlet with flange connection Wooden Pallets Internal or External lighting Panic Bar / Push Bar Low water level alarm Platform Activation Curtain Drain Sump and Grating Cable heating verhead ABS Shower Rose Scald r Freeze Protection Valve Stainless steel erecting lugs Ex-proof or non ex-proof flow switch MATERIAL Cubicle Cabin Frame uter Cover Interior Cover Galvanized Steel S S Aluminium - - S 304 Stainless Steel 316 Stainless Steel GRP S : STANDARD : PTINAL 7

ISTEC TYPE ESW-MSS MBILE SAFETY SHWER, EYEWASH WITH TRAIL (1500 LT) Standard 1260 lt verhead Tank Showers guarante 15 minutes of water flow according to the standard requirements in bellow circumstances; 1. Without mains (water) supply connection 2. In low water pressure 3. Interruption of flow in existing water supply connection Ideal for applications where there is no mains water supply 1500 lt Water Tank on trailer Trailer is equipped with signals, lights, oblong plate, parking brake etc, according to highway regulations Suitable for temperatures -5 Cº / +40 Cº Stainles Steel emergency shower and eyewash Emergency Shower Material (Galvanized and Painted Steel or Stainless Steel) Pneumatic Water Pump For Hazardous Areas Electrical Pump For Non Hazardous Areas 50 lt 200 Bar air cylinder with pressure regulator (for operating of pneumatic pump) with its bracket & straps Stabilizing legs Bumper Bar Visual water level indicator Extention Tank Safety Signs and Green - White stripes Available in green, yellow or white color Ex-proof or Non Ex-proof Audible And Visual Alarm Ex-proof or Non Ex-proof chiller cooling unit Ex-proof or Non Ex-proof Lighting Scald or Freeze Protection Valve Testing Lever Eyewash Foot Treadle verhead ABS Shower Rose 316 Stainless Steel Shower Material Water Pressure Regulator Low Water Level Alarm Visual Water Level Indicator Visual Water Temperature Gauge Water Immersion Heater Water Low And High Temperature Alarm Atex and Gost Guarantees correct flow rate and 15 minutes of a tepid water supply ISTEC TYPE SHT SEPARATE HEADER TANK Standard 1260 lt verhead Tank Showers guarante 15 minutes of water flow according to the standard requirements in bellow circumstances; 1. Without mains (water) supply connection 2. In low water pressure 3. Interruption of flow in existing water supply connection Manufactured from galvanized steel and Stainless steel material Ideal to deliver water along 15 minutes for areas where no mains supply or interrupted water supply and enough space Different metarial options (Galvanized Steel, Stainless steel, GRP) Available also for capacity of 30 minutes of water supply ptions for non hazardous or hazardous areas Available in green, yellow or white color Safety Signs and Green - White stripes Ex-proof or Non Ex-proof chiller cooling unit Water Immersion Heather Water Low And High Tempature Alarm Visual Water Level Indicator Visual Water Temperature Gauge verhead sun canopy Drain valve Flanged inlet Submersible Pump 8

ISTEC TYPE DEC DECNTAMINATIN UNITS Decontamination Showers provides sanitation and decontamination to the people exposed to chemical or biological agents, As well as to extinguish burning clothes. Autostart once stepped on the platform. 14 spray nozzles sprays necessary water to whole body. Swivelling spray provides easy decontamination. Stainless Steel or Galvanized and Painted steel material options ptionally be added side & rear panels and grating ptions for hazardous and non-hazardous areas Ex-proof or Non Ex-proof Audible And Visual Alarm Ex-proof or Non Ex-proof Lighting Eyewash Foot Treadle 316 Stainless Steel Material Water Pressure Regulator Flanged inlet ISTEC TYPE EW-P PRTABLE EYEWASH Ideal for applications where there is no mains supply Can easily be carried by two people. 2'' filling plug, 25 lt. water capacity. Sprays aerated water. Rinses eyes and face with clean water by nozzles. ptionally operated by a trigger valve. Unlimited use by filling water and air. Gost With Trigger Valve With Fixed Spray Nozzle 9

Телефоны для связи: +7