V 02/09 AN SS RE OWNM

Similar documents
The Following Care Instructions Can Help Preserve Warranty Rights

DIGITAL STEEL FIRE & SECURITY

Selecting a. water mattress. Smart Shopping for Home Furnishings WHAT S ON THE MARKET? Dr. Leona Hawks Home Furnishings & Housing Specialist

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

WA A Aqua Sub Bottom-load Water Cooler

DIGITAL STEEL FIRE & SECURITY

HANDHELD FABRIC STEAMER.

Tower Fan MODEL# EE-5607

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

LETTER FROM THE FOUNDERS

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Authorized Replacement Parts Form EdenPURE

Instruction Manual Item No.: V~, 60Hz

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Installation and Operating Instructions

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

FIRST CLASS - TRAVEL IRON

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

The FAWSsit USER CARE GUIDE

A2Z Ozone, Inc. PRODUCT MANUAL

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

matt GRD: GRD 28/02/08 9:17 Page 1.

USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC

Ui REFRIGERATOR SPEC SHEET

AIR OZONE GENERATOR MANUAL MODEL AIR /240V 50/60HZ

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Owner s. Coolerr. comply. To view

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

Energedry Eliminator 52K

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

Energedry Elite Eliminator Pest Control Electric Heat System

TUBULAR LLdia-PUMPyy INSTRUCTIONS

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

12,000 BTU Evaporative Portable Air Conditioner

Instruction Manual Item No.: V~, 60Hz

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

WHOLE HOUSE FILTER &

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

MIGHTY PRO 1/4 HP CHILLER

INSTRUCTION MANUAL. Elite Digital Steam Press SSP-2202

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

Radial 8 Heater For Professional use only

Industrial Vacuums, Inc

OWNER S MANUAL & WARRANTY

BASEBOARD MICATHERMIC HEATER

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Item no PERSONAL V2.0. User s Manual

Comfort Series Instant Hot Water System

45 Wide Format Hot and Cold Laminator

Portable Dehumidifier

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

COMPACT GARMENT STEAMER

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE

The ZappBug Room TM. Owner s Manual SAFE PROVEN EXTERMINATION. IMPORTANT NOTICE: Read Warnings Before Use!

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

Owner s. 18 Misting MF18W. To view

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

PORTABLE AIR CONDITIONER OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

Model R060 Installation - Operation Manual

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

ERG400 ROWER OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW ROWER

Wilbur Curtis Company, Inc.

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Oahu Showerspa Model #1035 Owner's Manual

Thin Window FAN With Comfort Control Thermostat. Instruction Leaflet. pure indoor living MODEL: BWF0522M-CN

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

INSTRUCTION MANUAL HS-229G

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

USE AND CARE MANUAL. Before operating the iron, please read these instructions carefully and keep them for future reference.

PROPANE CONSTRUCTION HEATER

OWNER S MANUAL. 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series. * Output dependent on room temperature and humidity.

Panel Mounted Heat Exchangers by Dantherm, Inc.

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

Portable Dehumidifier with Internal Pump

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

USER S OPERATING AND INSTRUCTION MANUAL

User s Manual and Operating Instructions

IMPORTANT SAFETY INFORMATION:

Cool-Touch Deep Fryer / Fondue Maker

DualTempSM. Help is just a click or phone call away. FPO

DZ5080 US Index01 19/09/07 10:50 Page 2

Whynter Portable Ice Maker 33 lb capacity - White

Garment Steamer Model SC620

owner s manual MX650-CCX

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Installation Instructions Model: EB Single-Lever Lavatory Faucet

Transcription:

Assembly Instructions for 8" and 6.25" Fill Depth Sterling Soft-Sided Flotation Bed Systems Cover Border Cover Border Folded down over Foundation Foam Perimeter Rails in place Cover Border Pulled Back up 1. Assemble the metal bed frame according to the separate bed frame manufacturer's instructions and attach the headboard and footboard if necessary. A heavy duty metal bed frame with center support is required. Place the bed frame in the exact location you intend for the bed, making sure an electrical outlet is nearby if a heater will be used. 2. Place the box foundation on the metal bed frame with the white law label at the head of the frame. Install any dust ruffles you may have now. 3. Unzip and remove the quilted top panel from the cover border. Place the cover border on top of the foundation, white law label at head of bed. Pull the corners of the border down over the foundation corners. This will keep the cover border square and in place while you set up and fill your mattress. 4. Assemble the foam cavity following the example drawing at the left. Place the longer side rails on top of the bed at the sides and the shorter rails at the head and foot of the bed. Square the sides with the foundation and insure there is equal spacing on all sides of the cavity to the foundation. Pull the cover border up around the foam rails. 5. After you have assembled the foam perimeter, install your heater. Follow the heater manufacturer s instructions carefully for proper installation. This system has been designed to be used with a waterbed having a rigid support for the heater and water mattress. Run the electrical cord and temperature probe down through the holes provided in the white bottom cloth of the cover border. CAUTION: Do not plug the heater into a power source until the bed is completely assembled and filled with water. Failure to follow this instruction will invalidate your warranty and could cause damage to other components of the bed or personal injury. CAUTION: When you fill the water mattress later in the setup process, put enough water in your mattress so that you cannot make the top sheet bottom out. Any contact with the bottom of the bed when sitting or lying on the bed is considered bottoming out. Bodily contact directly over the surface of the heater pad may cause damage or personal injury. CAUTION: We do not recommend the use of a waterbed to anyone who cannot sense hot and cold or cannot move themselves without help. For Dual Mattress only - Beginning in 2007 Sterling softsided watermattresses were delivered with CONTOUR safety liners unless a dealer specifically requested the old style fitted liner. As of 2008, only contour liners were supplied by the factory. Both types of liner work well and are interchangeable. If a waterbed heater is being used, it must be installed before the safety liner and watermattress are installed We recommend the use of a heater to better prevent mildew in humid climates and for comfort. Follow the heater maker s instruction. Make sure the heater is unplugged 1

The far bed in the photo is a properly installed watermattress with a FITTED safety liner as used before 2007. The bed in the forground shows an air inflated watermattress with Black CONTOUR safety liner properly installed, ready for placement inside the foam perimeter. Properly installed black CONTOUR safety liner & watermattress in foam perimeter Sterling Concierge Softside with zippered cover installed. 2

Installing the watermattress inside the contour safety liner. The easy way to install and align your contour safety liner and watermattress assembly in the foam perimeter of your waterbed is to inflate the watermattress with air until it unfolds all the wrinkles. Do not use the hot air setting on your hair drier or damage can result. Then deflate until the mattress resumes a rectangular shape before installing the safety liner. Start by opening the mattress fill valve and inflating with air. (see photos) If you choose not to inflate the mattress with air, go to direction #9 below. 1. Now install the inflated mattress inside the contour safety liner (see photos on page 2) 2. Install the mattress & liner assembly inside the foam perimeter & adjust alignment by centering the liner + watermattress assembly inside the foam perimeter head to foot and side to side. 3. Add 8oz of Sterling water conditioner and fill with warm water until the filled watermattress bladder is level or below the top of the surrounding foam perimeter after air bubbles are removed. Do not over fill or the safety liner will not be able to contain the entire contents should a leak occur. Proper filling is the owners responsibility. a. Treat with 8oz of Sterling water conditioner every 12 months for best results 4. Remove any remaining air and install the plug and cap. 5. Plug in and turn on the heater= set temperature at 88. Give the water several days to come up to temperature. The heater light goes off when the set temperature is reached. a. Make temperature adjustments up or down 2 degrees at a time allowing 3 days for the water temperature to adjust before making additional changes. b. Leave your heater on year round, the thermostat will not turn on unless the water temperature drops. Keeping your watermattress slightly warm prevents condensation and mildew c. If you do turn the temperature down in the summer, 80 degrees should be the lower limit. d. Keep your bed covered. The added insulation helps your bed retain heat and lowers your electric bill. 6. For the first few weeks after setup you will need to repeat air bubble removal because most drinking water is aerated to improve taste. As water is warmed, dissolved gasses are released with the increase in molecular activity. This can go on for 6 months a. how often you remove air depends on how much the air bubble noise bothers you. Use a broom handle to sweep the bubble to the fill valve. 7. It takes the wave control system about a week to expand and work up to its potential after set up. Wave reduction properties diminish slowly with years of use and is considered normal wear and tear. 8. Wave reduction material contribute to firmness and support, however water fill level is the key factor in determining how well your waterbed supports your particular size & shape. a. To adjust support, add or remove a few gallons of water at a time until the bed is just right for you. 9. If you choose not to inflate the watermattress with air for setup and installation: a. Spread the contour safety liner out flat inside the foam cavity with the open side facing up. b. Center the safety liner head to foot and side to side c. Open the watermattress fill valve to let air into the mattress so it can be unfolded and so that wrinkles can be removed. A 2nd person is needed to pull out the wrinkles. d. Place the unfolded watermattress on top of the contour liner e. Without changing the alignment, lift open each of the four safety liner corner pockets so the watermattress corners can be placed inside the contour liner. f. Now go back to instruction #3-#7 above. 10. Zip on the quilted mattress panel, pull the zipper out and up away from the foam perimeter to avoid jamming the zipper. 3

Removable Zippered Cover Water Mattress Contour Safety Liner Heater (Single or Dual) Note: Install heating pad according to heater manufacturer s instructions. Make sure the heater pad does not cross the seam between foundations. Side Rails Head/Foot Rails and Side Rails are interlocking Zippered Cover Border Box Foundation 4 9 leg Heavy Duty Metal Bed Frame, Riser or Drawer Pedestal

Filling and Draining Instructions Filling Using an indoor faucet Unscrew the air-screen from the faucet. Use the white double threaded faucet adapter to adapt the threads of the faucet to the threads of the filling hose. Fill the mattress through valve #1. Valve #2 * allows air to escape during filling. Add or drain water to personal preference. Adding water makes the mattress firmer, draining makes it softer. To eliminate air, remove the cap from valve #2 (air release valve optional). Extend the fill valve to its full length and guide the air bubbles to the valve. Using a broom handle, slide the trapped air bubbles across the top to the valve. Reapply the cap. Repeat the process again as necessary. * Not all models have valve #2 CAUTION: We do not recommend the use of a waterbed to anyone that cannot sense hot and cold or cannot move themselves without help. Two Piece Faucet Adapter Note: Faucet adapter may be used for both male or female thread type faucets. Remove top portion of faucet adapter for male threaded faucets. Male Threads Female Threads Hose (garden type) Hose Shut-Off Valve Hose Adapter To Drain Turn bottom of pump to the left and pull down Venturi Pump To Fill Turn bottom of pump to the right and push up Threaded Flange Water Mattress Fill Valve Air Vent Valve (optional on some models) Draining your waterbed (Use an electric drain pump if possible) 1. Unplug your heater before draining the bed. 2. Leave water mattress flat until completely drained or the wave control system will shift and become damaged. 3. We recommend the use of an electric pump or a Venturi Siphon Pump available at your local hardware store. Follow manufacturer s instructions. Airtight connections from the drain valve to the pump are needed to remove all the water possible. 4. Drain the mattress until water stops and the mattress becomes very wrinkled. Beds will drain to within 15 pounds of dry weight with good airtight connections. 5. Allow some air back into the mattress, remove the drain hose, and replace the plug and the fill cap. This will prevent the wave control system from shifting. Fold the mattress before removing from the bed. If mattress is to be stored for an extended period, add a bottle of Sterling Water Conditioner to the drained bed. 6. Do not drag your mattress across the floor or carpet, the friction can cause a hole in the folded vinyl. 5

Soft-Side 20 Year Limited, Prorated Warranty This warranty applies to defects in workmanship or materials for the original purchaser only. Sterling will repair or replace, at its option, the parts found to be defective exclusive of transportation costs. The manufacturer reserves the right to inspect the defective component prior to making a warranty determination. It is the owner s responsibility to return the defective component prepaid with proof of purchase. Product replacement after the full portion of the warranty will cost the consumer of retail price at time of return. If identical materials are not available at time of product service, Sterling reserves the right to substitute materials of equal or better quality. Warranty does not apply to subsequent damages. Wa rranty Schedule Soft-Side Mattress Full Coverage Prorated period Cost to replace S Class Mattress Original Sterling Mattress Parkline Mattress 3.5 Tubes Foam Perimeter Box Foundation Quilted Mattress Top Panel 5 years 4 years 3 years 2 years 3 years 3 years 90 days Limited Life Time 16 years 17 years 18 years 17 years 17 years NONE % of suggested retail at time of return N/A Wa rranty will apply only when your flotation sleep system is used with: An approved, properly supported bed frame. An approved pin hole free safety liner, constructed of at least eight (8) gauge or heavier vinyl, must be installed so the liner reaches the top of the perimeter and is capable of holding the entire contents of the water mattress. Sterling Water Conditioner or equivalent to preserve the interior of the vinyl mattress An approved and properly installed Flotation Sleep System Heater to control condensation and mildew. For proper installation instructions, see the heater manufacturer's instructions. Items not covered by warranty: The quilted cover is warranted for a period of 90 days from date of purchase. Body impressions. Customer abuse and improper care. Soiled, stained or burned bedding. Sanitation laws prohibit return of bedding that is not hygienically clean. These items will not be accepted for repair or return regardless of any other claimed defects. Freight costs. Service charges to remove or install the bed. Subsequent damages. Wa rranty Voided for Misuse This warranty is void in case of any damage to the mattress resulting from improper installation, unauthorized repairs, improper accessories, or abuse. Sterling Sleep Systems APPF, Inc. 7274 Lampson Avenue, Garden Grove, CA 92841 Phone (714) 891-3191 Fax (714) 891-6770 www.sterlingsleep.com O WNMAN SS REV 02/09 6

Warranty Claim Form Customer's Responsibilities If damage to your mattress is due to seam failure or defective material, clearly mark the damaged area with a marking pen. Drain the mattress completely and return it to your dealer. If your dealer recommends factory service, send it freight prepaid to: Sterling Sleep Systems, APPF, Inc., 7274 Lampson Ave., Garden Grove, California 92841 Proof of Purchase Daytime Phone Cause of Failure Method of Payment Shipping Address Call our factory Customer Service for instructions first before returning your mattress. Limitations and exclusions: Any and all implied warranties are limited to the duration of the written warranty. All consequential and incidental damages are specifically excluded. Our warranty liability is limited to replacement of defective product only. 1. Include a copy of your proof of purchase to establish ownership, date product was first used. 2. Daytime Telephone Number - Where you can be reached if we have a question 3. Cause of Product Failure Seam Leak Corner Leak Valve Leak Other 4. Credit Card - to prepay return freight VISA MASTER CARD AMEX Card Number Name as appears on Card Expiration Date Signature 5. Name Address - Where you want the replacement water bed sent. No P.O. boxes please. C ity State Zip 6. A complete copy of this form must be sent for warranty claim. Date of Purchase Dealer's N ame/a ddress Mattress Model Size Note: Shifting of wave control system is not covered by warranty. If you have any questions please call Customer Service at (714) 891-3191, 8 AM 5 PM PST, or e-mail your questions to Sales@sterlingsleep.com 7