Polytector III G999 for Ex zone 0

Similar documents
Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger X-am 7000 Multi-Gas Detection

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger X-am 7000 Multi-Gas Detection

ALTAIR 5X Multigas Detector

Monitores Personales. Personal Monitor

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ALTAIR 5X Multigas Detector Product Specification

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 2500 Multi-Gas Detector

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

1.1 Definitions of alert icons. For your safety

GasAlertMicroClip X3 Specifications

Dräger X-zone 5500 Area Monitoring

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

T.ex Single Gas Detector VISA

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Dräger X-am 5000 Multi-Gas Detector

Dräger X-zone 5500 Multi-Gas Detection Device

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Overview of Fixed Gas Detection, the GfG Product Range plus NEW PRODUCTS available in 2019

Products & Services. Portable gas detectors and fixed gas detection systems for all applications. GfG Gesellschaft für Gerätebau mbh

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Dräger Pac 8500 Single-Gas Detector

Dräger X-zone 5500 Area Monitoring

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

IMR IX176 Portable Gas Detector User Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

RAE Systems Systems. User Presentation. October Protection Through Detection

CO warning instruments and gas spillage detectors

VENTIS PRO SERIES. Product Guide

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Dräger Pac 8500 Single-Gas Detection Device

SAFESITE Multi-Threat Detection System

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

For the Safety of Your

Dräger Pac 6000 Single-Gas Detector

Hygrometer / Air Quality Meter

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Microtector II G460. Operation Manual. 1 to 7-Gas Detector

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Understanding the practicalities of using gas detectors in confined spaces

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Safe Operation Manual. Honeywell IQ Force Gas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Operate the Mutli-Gas Monitor PID

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

G-TECTA TM. Portable Gas Detection Instruments

We measure it. testo 316-Ex CH 4 testo 316-1

GAS DETECTION & RESPIRATORY PROTECTION

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Dräger Pac 3500 Single-Gas Detection Device

GX-2009 Portable Gas Monitor Operator s Manual

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

Dräger X-am 2500 (MQG 0011) Technical Manual

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Dräger Pac 6000 Single-Gas Detection Device

PROTÉGÉ ZM SINGLE GAS MONITOR

MICROTECTOR II G450 OPERATION MANUAL 1 TO 4-GAS DETECTOR

GAS ANALYSIS / DETECTION Gas Detector

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Microtector II G450. Operation Manual. 4-Gas Detector

IMR EX610. Portable Gas Detector. Operation Manual

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

IT S WHAT S INSIDE THAT

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

PERSONAL COMBUSTIBLE GAS DETECTOR

Issue 4 10/10/11. Part Number: 48160

E1000 Portable gas detector

Dräger Pac 3500 Single-Gas Detection Device

Portable Gas & Flame Detection Product Overview

Dräger Pac 7000 Single-Gas Detection Device

Microtector II G450. Operation Manual. 1 to 4-Gas Detector

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Operations Manual TS400. Test Station for G450/G460 Gas Detector

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Datalogging as standard

Dräger Catalytic Ex-Sensors DrägerSensors

Using the QRAE Plus personal multigas monitor

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Transcription:

Polytector III G999 for Ex zone 0 7 Sensor Personal Gas Monitor with smart pump, remote multiple instrument monitoring, two way communication and Man Down options

Record-breaking The G999 is the world s smallest and lightest 4-7 personal gas monitor with an integrated electrical suction pump and optional Radio communication. The G888 can detect toxic, flammable gases & vapours along with Oxygen depletion and enrichment. Numerous sensor combinations and comprehensive accessories ensure the G999 can can be used in a wide range of industry applications. A crocodile clip ensures safe retention Status display with an integrated Ex-protected lamp Time Easy operation The main functions - peak display, EX LED lamp, alarm reset, display zoom and rotating display can all be controlled with a simple keystroke and the device has a convenient 3 button user menu. Man-down alarm The G999 has been equipped with a mandown alarm. The time interval for when the alarm should be triggered can be individually set and password protected so that in critical cases no time is lost while initiating rescue measures. Wireless live measurement data The G999 can send realtime data by radio to a central GfG-Link or an operation centre. PC and tablet The visualisation software, GfG-Connect, can be used on Windows -based PCs or tablets. Up to 20 devices can be displayed as a list or with a detailed view. Radio reception with signal strength Battery status Display of the measured value Key assignment Graphic display with zoom function can be rotated through 180 Easy operation with 3 keys LED alarm bar Optical alarm system with colour change on the display IrDA interface and optional radio Slide switch to activate the pump 5 sensor sockets Alarm horn with 103dB(A) and vibration alarm 3/4 smart EC sensors 1 pluggable CC sensor 1 smart IR sensor 1 photo ionisation (PID) 1 hybrid (CC/CS) Data logger for 30,000 measured values Integrated explosion protected lamp Robust, slip-resistant and water-proof housing (IP67) Integrated pump Intake manifold

GfG-Link The GfG-Link can connect from 1-4 or 5-10 devices. Both the user name of the device and the current measurement data is displayed on the GFG Link. The lifesaving man down alarm has a special status and is amplified by an unmistakable acoustic signal sequence and a red flashing alarm display. The GfG-Link display represents all connected devices and their current status. The open field range is approximately 700m (1400m radius) Pager function The GFG-Link can send short messages to the G999 and you can choose between free text on a PC or preconfigured standard messages with the GfG- Link. The short messages can be confirmed from the G888 with short standard replies such as OK. Alarm simulation In order to prepare your personnel for an emergency, the G999 is equipped with a training mode. It is possible to simulate instrument alarms via PC or the GfG-Link. GfG-Link 1 2 3 Man down alarm 4 6 5 7 8 9 Pre-alarm 10

Sensor Options Several versions are available: One version is: 1x combustible catalytic (CC), 1x infra- red (IR), up to 3x electrochemical (EC). The design of the G999 allows different sensor combinations ensuring most industry requirements are met. Sensors Using the best quality sensors ensures reliability, better accuracy, quick response and reduced cross sensitivity. Using smart sensors makes servicing easier. The infrared principle (NDIR) With only one IR measuring chamber, carbon dioxide and hydrocarbons can be simultaneously yet precisely detected as the sensor uses up to four gas-specific wavelengths. Absorption paths and wavelengths are perfectly adapted to gases and measuring ranges. Damage to the sensor by silicone compounds or hydrogen sulphide can be excluded with IR technology. The IR sensor has the advantage of heat tone sensors so that it is not damaged even at the highest gas concentrations. PID Photoionization Detector Highly volatile organic compounds (VOC) such as solvents, petrol vapours, die- sel fumes, or kerosene vapours, are harmful to health even in low ppm or ppb concentrations. The occupational limit value for most of the VOC is far below the Lower Explosion Limit (LEL) and cannot be detected with heat tone sensors. The PID sensor calibrated on isobutylene can detect these compounds at concentrations of less than 1 ppm. Hybrid sensor / Leakage lo- calisation In lots of applications a simple detection of combustible gases in the range from 0 to 100% LEL is not sufficient. The G999 can be equipped with a high quality GfG hybrid sensor which can measure methane from 0 to 10,000ppm, from 0 to 100% LEL and from 0 to 100Vol.%. It is possible to convert your gas warning device to a powerful leakage detector using the smart, electrical suction pump Main alarm: Highest alert level Pre-alarm: Caution! All measured values in the normal range

Smart suction pump The integrated highperformance pump is activated by closing the diffusion openings. The measured results are not falsified by the influences of gas in the direct environ- ment of the device. The suction capacity is designed for a distance of up to 100m or more. The current flow rate and the distance of the suction hose will be displayed on the screen providing the safest solution when performing free release measurements in confined spaces, tanks, cellar wells or ducts, also in the Ex zone 0. The pump end sensors are protected against dust and humidity with a filtering system. Large display & zoom function The clear graphic display can be rotated through 180 and can be conveniently read in any position it is worn, e.g. if you have attached it to your work clothes you have both hands free and can keep an eye on all the displayed values. The zoom function of the display facilitates the reading of the device while other PPE is worn e.g. under a breathing mask or without the need for reading glasses Alarm thresholds The alarm thresholds for oxygen and combustible gases as well as two current limits for toxic gases and explosion alarms provide comprehensive protection for the user. Long Term Value (LTV or (TWA) Short Term Value (STV) or (STEL) will be automatically monitored as mean value and the average value will be saved. All limits can be individually set and pass code protected. Data logger The integrated data logger simultaneously records up to 12 measured values and saves internally up to 30,000 measured values (500 hours at 1 minute logging intervals). The saved data can be conveniently read via the smart cap or drop-in charger. Safety meets design The G999 combines technical innovation with captivating design. An independent committee of experts have commended the outstanding performance in design and functionality, with special consideration given to the size and weight of the device. The sensor cover of the Polytector III G999 can be individually designed with colours, if desired. In this way, you can distinguish differently equipped devices at a glance.

USB Dongle for Radio communications Open Field 700m Other antennas on request Holster with belt Optimum protection against soiling Float sensor For the clearance measurement of water bearing channels and wells Stainless steel telescopic suction tube For the clearance measurement of channels, wells, containers and confined spaces Only use in EX zone 0 Available in the lengths 1.36m and 1.92m Antistatic special hose with filter For the protection against humidity and particles Available in the lengths 3m and 6m

Technical data Polytector III G999 Electrochemical (EC) measuring principle: Up to 4 different sensors: Toxic gases and oxygen (ppm / Vol.-%) Catalytic sensor (CC): Flammable gases and vapours (up to 100% LEL) Infrared (IR): Carbon dioxide (Vol.-%) Hydrocarbons (100 % LEL and Vol.-%) Expected service life of the sensor Up to 5 years; depending on the sensor type Device versions: G999C 3x electrochemical sensors (EC) 1x catalytic sensor (CC) 1x infrared double sensor (IR1, IR2/IR3) G999P 3x electrochemical sensors (EC) 1x photo ionisation sensor PID 1x infrared double sensor (IR1, IR2/IR3) G999E 4x electrochemical sensors (EC) 1x infrared double sensor (IR1, IR2/IR3) Measuring gas supply: Diffusion / integrated electrical suction pump Display: Illuminated LCD graphics display with colour change for the alarm display can be turned by 180, automatic zoom for best readability Alarms: Three or two current value and two exposure level alarms, battery alarm depending on the type of gas Optical alarm: Colour of the display depends on the alarm status of the device (green/orange/red), 360 all-round red LED Acoustical alarm: 103 db (A) loud and can be Reduced to 90 db (A) Temperature: Operation: Storage: Humidity: Operation and storage: -20 C.. +50 C -25 C.. +55 C (Recommended 0.. +30 C) 5.. 95 % rh Pressure: Operation and storage: 70.. 130 kpa Zero point / Sensitivity adjustment: User-friendly, automatic adjustment via AutoCal function, manual adjustment in the sensor menu Energy supply: NiMH battery Charging: Charging and trickle charging via the charger or docking station Device runtime depending on the equipment: 15h EC+CC+IR+radio 18h EC+CC+IR 22h EC+PID+IR+radio 42h EC+CC(PS) 52h EC+radio 130h EC Charging times: About 6h if the battery is flat About 3h after a shift (with 3xEC+CC+IR sensors) Dimensions: 68 x 135 x 30 mm (WxHxD) Display diagonal 55 mm Weight: up to 395g depending on the sensor equipment Housing material: Rubberised polycarbonate Protection class: IP67 Automatic maintenance reminder: Display when switching on Data logger: About 500h data recording (interval of 1 minute) 30,000 measured values, 12 values simultaneously Intervals can be set (1 s - 60 min) Recording of mean, peak or instantaneous values can be selected Type examination certificate: BVS 15 ATEX E 064X IECEx BVS 15.0056X Labelling and ignition protection class: ATEX for G999E, G999P II 1G Ex ia IIC T4 Ga I M1 Ex ia I Ma IECEx Ex ia d IIC T4 Ga M1 Ex ia I Ma ATEX for G999C II 2G Ex ia db IIC T4 Gb I M2 Ex ia db I Mb IECEx Ex ia db IIC T4 Gb Ex ia db I Mb Wireless: 868MHz Europe 915MHz USA Bluetooth (available as of 2019) GfG Europe Ltd Unit 8 Griggs Business Centre West Street Coggeshall CO6 1NT Essex UK Tel.: +44 (0) 1376 561463 Fax: +44 (0) 1376 561704 www.gfgeurope.co.uk sales@gfgeurope.com