EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

Similar documents
REPACKAGING A TRANSURANIC WASTE STREAM FOR WIPP DISPOSAL

COST EFFICIENT TRU WASTE PACKAGING AND A SAFER AND FASTER METHOD OF REMOVING TRU WASTE FROM GLOVEBOXES. S. D. Chunglo La Calhene Inc.

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Portable Survey Instruments NISP-RP-01

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

2.13 RADIOLOGICAL INCIDENTS and EMERGENCIES RCT STUDY GUIDE Identify in general how an RCT should respond to an emergency.

OHIO UNIVERSITY RADIATION SAFETY REVIEW

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

50(394) IEC. ore content meter ore sorting equipment overvoltage (of a Geiger-Müller county tube)...

Identify the following features and specifications for the ESP1

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

J. S. Baker J. A. Smith

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Depleted Uranium Waste Assay at AWE. T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK

DEEP GEOLOGIC REPOSITORY PROJECT JOINT REVIEW PANEL RESPONSE TO INFORMATION REQUEST EIS

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

HEALTH AND SAFETY MANUAL

Investigation report. Radiation resistance of fire detectors under the influence of radioactive gamma radiation

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Remote Gamma Imaging of High Dose Environments

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

Radiation Control and Monitoring System on the HTTR

Highlights from a recent test campaign in Finland with scalable neutron detectors

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Advanced Radiation Measurement Solutions

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

Radiation Monitoring Systems

Replacement of the Criticality Accident Alarm System in the Tokai Reprocessing Plant

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

American Nuclear Society (ANS)

DMC 2000 Personal Electronic Dosimeter

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

DMC 3000 Quick User s Guide

Radiation Safety for AREAL Phase 1

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Radiation Alert Frisker INTERNATIONAL

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

Portable Instruments For First Response & In-Situ Analysis of Radiation

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Telephone: +44 (0)

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

A NOVEL APPROACH TO DRUM VENTING AND DRUM MONITORING

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

Brine Generation Study

North American Technical Services

Dynamic Radon Detection Over Measurement

Radiation Monitoring Equipment

MODEL 3216 ROOF MOISTURE GAUGE

Consultation Draft. Issue 2. Good Practice Guide No. 29. The Examination, Testing and Calibration of Installed Radiation Protection Instruments

Radiation Safety Guidelines for Non-Users

WM 05 Conference, February 27 March 3, 2005, Tucson, AZ

Seismic Countermeasures for Environmental Radiation Monitoring System

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Quality Assurance of Radiation Protection Monitoring Instruments in India

Nuclear Associates

The European Commission s science and knowledge service. Building on core components of Technical Reachback

Instrumental technique (MCP detectors) - Kamalesh ( )

Radiation Monitoring System RMS

Containment of Basket Filtration Centrifuges ABSTRACT

Radioactive Contamination Monitor

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Beam Loss Position Monitoring with Optical Fibres at DELTA

Domestic Nuclear Detection Office (DNDO)

International Radiation Protection Association 11 th International Congress Madrid, Spain - May 23-28, 2004

Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

AGC Sputter Coating Glass Processing Guidelines

Surface Contamination Monitor. Operation Manual

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

Freiburger Materialforschungszentrum SG Material Characterization & Detector Technology. Albert-Ludwigs-Universität Freiburg

AERIAL RADIATION DETECTORS

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Small Controlled Area Radiography Fundamentals and Technology Advancements. J. R. Lapinskas, PhD and R. L. Kelly

Catawba Nuclear Station Delay Coil Chemical Decon Projects

product catalogue

minidose A compact and colorful personal electronic dosimeter, your family can use everyday.

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

Laboratory Impex Systems Ltd

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL

X-Ray Protection Program

Dosimeters/Survey meters

Co-60 irradiator for therapy level calibrations at SSDLs

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

Analytical X-Ray Safety Program

Vacuum Insulated Pipe

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

1. Attachment A Section A Product Specifications, #5 is being amended as follows:

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

Radiation Safety. Amplified.

Transcription:

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS M. Gallegos, R. Ruby, E. J. Sullivan, R. J. Wishau Los Alamos National Laboratory ABSTRACT The Los Alamos National Laboratory (LANL) Operational Health Physics Group, with the support of the Nuclear Materials Technology Waste Management Group, has developed a wraparound shield for use with 0.208 cubic meter (55 gallon) drums containing transuranic (TRU) waste. The shield or drum cover as it is called, is innovative in its ability to attenuate both neutron and photon radiation associated with TRU waste. This poster presents information on the design, fabrication and field use of the drum cover. Design details to be presented include the composition of the shield including the materials used, thicknesses, weight, dimensions and fastener arrangement. Information on the source supplier for the shield materials, the fabrication vendor and the drum cover cost are provided. Shielding data show the unique effectiveness of the drum cover and its ability to reduce neutron and photon radiation exposures as low as reasonably achievable (ALARA). These data include x-ray testing of the assembled shield materials, as well as field experience reports on the drum cover using TRU waste containers and neutron source drums. The poster includes discussion and photographs of recent field uses for the drum cover, user experience and acceptance of the drum cover and suggestions for future use and enhancement of the drum cover design. INTRODUCTION Various operations at Los Alamos National Laboratory result in the generation of transuranic (TRU) waste. TRU waste refers to waste materials containing elements with atomic numbers greater than 92 and containing more than 3.7 kbq of alpha emitting TRU per gram of waste. A standard container for TRU waste is a 55 gallon steel drum. These drums are prepared at LANL for disposal at the Waste Isolation Pilot Plant (WIPP) the underground TRU waste repository near Carlsbad, New Mexico USA. Several organizations at the Laboratory are involved in the preparation, packaging, characterization, temporary storage, and monitoring of these TRU drums prior to their transfer to the WIPP. These organizations include the Waste Management and Environmental Compliance group (NMT-7) and the Risk Reduction and Environmental Stewardship Division Characterization (RRES-CH) group. In the course of their work these groups will occasionally encounter TRU drums with higher than usual radiation levels. Personnel will then shield the drums to reduce the radiation dose rates to levels that are As Low As Reasonably Achievable (ALARA) thereby reducing their radiation doses.

This poster provides information on the design, testing and field use of drum covers that were developed to shield the TRU waste drums. THE DRUM COVER Design Recently, the NMT Waste Management and Environmental Compliance group decided to develop its own TRU drum shield. This decision resulted following an unsuccessful search to find an existing shield product that would be effective for both neutron and photon radiation. The waste management personnel provided design goals for the shield. These goals included: Effectiveness in shielding both neutrons and photons Easy to install and remove Provide a separate shielded lid for the top of the drum Provide a contamination-resistant durable outer layer Be light in weight so that one person could install the shield Shield fastens tight around the drum Radiation protection personnel provided design specifications for the shield s materials and capabilities considering the radiation associated with TRU waste. The shielding materials and thicknesses were a design consideration because a good photon shield is usually a poor neutron shield and vice versa. In the case of TRU waste, the neutrons are mainly spontaneous fission neutrons and the photons are low-energy x-rays or gamma photons. The gamma photons are dominated by the 60 kev emissions from the buildup of Americium-241 produced by the decay of Plutonium-241. Supply Central Ltd. of Albuquerque, NM served as the product vendor who procured materials, fabricated and delivered the drum covers to LANL. The finished design includes the shield material that is encased in a waterproof easy-to-clean jacket of yellow Herculite 80. The shield wraps around 55 gallon drums and is cinched tight using Velcro straps and two cam-tightened buckle belts. The drum cover also comes with a shielded lid. The shielding is comprised of two materials shown in a sectional view in the photograph in Fig. 1. The neutron shield is made of a 7 mm thick sheet of borated polyurethane material. This shield is made by ThermoElectron RMP Corp. and is marketed under the product name Borated FLE Panel No. 227a. This flexible product is 9 weight percent boron and has a high hydrogen content, and is self-extinguishing when exposed to flame. The photon shielding consists of two 0.175 mm sheets of composite lead vinyl fabric glued to each side of the FLE panel.

Fig. 1. In the photograph in Fig.2 the drum cover is shown installed on a 55 gallon TRU waste drum. The drum cover measures 89 cm high by 203 cm in length and weighs 22.7 kg. The removable shield lid is of similar composition and weighs 8.6 kg and measures 66 cm in diameter with 15 cm side flaps. Fig. 2. Shield Effectiveness Several tests were performed to evaluate the effectiveness of the drum shield. The tests were made using shield material samples and using the full size shield installed on typical TRU drums. The tests were performed using simple radiation attenuation methods and standard commercially available radiation protection field instruments. Neutron Shielding Test Results Table I presents neutron shielding results. Measurements were taken using a TRU drum and the drum cover in shielded and unshielded configurations. The type of instrument and the manufacturer and model are shown. The attenuation factor is the ratio of the shielded dose rate to unshielded dose rate. A ratio of 0.81 equates to a 19% reduction factor.

Neutron Instrument/ Manufacturer Test 1 SWENDI-II / ThermoElectron PDM-303 / ALOKA Co. Ltd. Test 2 Bubble detector / BTI Table I Neutron shielding test results Detector type Unshielded Shielded (µsv/hr) (µsv/hr) Helium-3 counter tube Solid-state proton recoil Superheated liquid vapor bubble Ratio 30.2 24.5 0.81 35.7 25.8 0.72 670 µsv 428 µsv 0.63 The neutron reduction ranged from 19 % to 36 % for the measurements listed in Table 1 showing that the drum cover is partially effective in shielding neutrons. Photon Shielding Test Results Two types of effectiveness tests were performed to evaluate the drum cover s ability to shield photons. The first was to expose x-ray film using standard diagnostic x-ray equipment and the second was using active and passive dosimetry and commercially available radiation protection field instruments. For the x-ray testing shielded film was exposed and developed to determine the degree of effectiveness of the shield. A diagnostic x-ray machine (General Electric Model DD350) set to 80 kvp, 100 ma and 1/20 sec was used to expose shielded film. Optical densitometer readings for the shield sample indicated a transmission of less than 10% at this energy (or an attenuation of 90%). The x-ray test results were confirmed using lithium fluoride type thermoluminescent dosimeter (TLD) chips placed in unshielded and shielded geometry. The TLD results indicated an average transmission factor (ratio) of 0.1 or attenuation of greater than 90 %. A third photon shielding test used a 55 gallon drum containing TRU waste and radiation protection field instruments. Using the drum cover unshielded and shielded radiation measurements were taken from both the side and top of the TRU waste drum. These gamma photon measurements were made with a ThermoElectron SHP300A energy compensated lowlevel GM probe. Photon shield effectiveness test results are shown in Table II.

Table II Photon shielding test results Location of Reading Unshielded (µsv/hr) Shielded (µsv/hr) Ratio Top(through the 594 75.5 0.13 shield lid, drum 1) Side ( middle of 1052 136 0.13 drum 1) Side (drum bottom) 133 12 0.09 These measurements indicated that for the predominant TRU waste photon energies the drum cover is very effective in reducing the photon absorbed dose [1]. Reduction ratios indicate an 87 % to 91% reduction in the photons passing through the shield. User Experience with Drum Covers Los Alamos National Laboratory organizations including NMT-7 and RRES-CH have used the drum covers in their work with TRU waste containers. Interviews were conducted with a number of personnel in these organizations to learn about their experiences and acceptance of the drum cover as an ALARA tool for their work. In general users are satisfied with the shield performance, and the total weight of the drum cover. The drum cover is somewhat awkward to handle when working alone and preferably two people would install the drum cover onto a drum. A drum cover rating summary was prepared from interviews with the user groups and is shown below as Table III. Table III Drum cover rating summary Drum Cover Features Excellent Good Average Poor Comments Fit and tightness on the drum Ease of use of tightening belt Function of Velcro strap Some straps have torn requiring repair Ease of handling and lifting Somewhat difficult for one person to handle Effectiveness in shielding neutrons Effectiveness in shielding photons Cost effectiveness at unit price of $ 1395 Ease of cleaning Ease of storage when not in use Needs a large size shelf or storage cart

CONCLUSION The drum covers have proven to be effective in shielding personnel from radiation when working with TRU waste drums. The drum cover has satisfactorily met its design goals for weight and ease of installation. The drum covers were rated as excellent in their fit on the drums and their ability to be cleaned. Overall, the users are pleased with their performance. The drum cover is gaining acceptance with the users, and they have shown to be a worthwhile ALARA tool for reducing personnel radiation exposures. REFERENCES 1 R. J.Wishau, J. M. Castro, R. L. Huchton, Evaluation of a Neutron-Photon Shield for Transuranic Waste Containers, LA-UR-02-467, Los Alamos National Laboratory (2002).