CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

Arctic EVAPORATIVE COOLER USER MANUAL

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

DESICCANT DEHUMIDIFIER

Portable Air-conditioner

Portable Air-conditioner Use and Care Manual

MD2000 Dehumidifier with 2 litre Tank USER MANUAL

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

Mobile Air Conditioner Instruction Manual Model TC-N9KM

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

PORTABLE AIR CONDITIONER OWNER S MANUAL

MODEL: DC10RCDH / DC12RCDH

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

PORTABLE AIR CONDITIONER OWNER S MANUAL

Dimplex Air Conditioner DAC 12000R

CAP600AWS Compact Air Purifier with Plasma Ionizer USER MANUAL

Reverse Cycle Portable Air Conditioner with Dehumidifier

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

ARTICA. 8000Btu. Room Air Conditioners Portable Range

PORTABLE AIR CONDITIONER

AC-12200E Portable Air Conditioner

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Local Air Conditioner

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Instruction Manual Item No.: V~, 60Hz

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Portable Air Conditioner

PORTABLE AIR CONDITIONER MODEL NO: AC7000

COMPRESSOR DIGITAL DEHUMIDIFIER

Certified to CSA STD. C22.2 No.117

7. CARE AND MAINTENANCE

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

Premium Low Energy Compressor Dehumidifier with Digital Humidistat CD16LE 16 litres per day USER MANUAL

USER MANUAL PREMIUM LOW ENERGY COMPRESSOR DEHUMIDIFIER WITH DIGITAL HUMIDISTAT AND AIR PURIFIER. CD12LE 12 litres per day CD20LE 20 litres per day

Instruction Manual Item No.: V~, 60Hz

Local air conditioner

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

PORTABLE AIR CONDITIONER MODEL NO: AC9000

Portable Air Conditioner. Instruction Manual

P O R T A B L E Air Conditioner

30-pint Dehumidifier User Guide

air conditioner/dehumidifier 9000btu/hr

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

Instruction Manual. Portable Air Conditioner

IG9813 USER MANUAL. 12 Litre Dehumidifier White. Batch code:

EVAPORATIVE AIR COOLER SERVICE MANUAL

with plasma ioniser and Remote Control USER MANUAL

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

PORTABLE AIR CONDITIONER (LOCAL)

USER MANUAL DESD9L PREMIUM DESICCANT DEHUMIDIFIER

Dual-Hose Portable Air Conditioner User Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

Safety Instructions 2. Installation 4. Parts 5. Control Panel 6. Quick reference guide 9. Remote Control Features 12. How to Connect to WiFi 14

Portable Air Conditioner

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

PORTABLE AIR CONDITIONER (LOCAL)

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Premium Low Energy Compressor Digital Humidistat Dehumidifier & Air Purifier with UV and Plasma Ionizer

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

LOCAL AIR CONDITIONER

GDDEM10 DEHUMIDIFIER

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

IMPORTANT SAFETY INSTRUCTIONS

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Instruction Manual. Model: EPA 16 Portable Airconditioner

MD400 Intelligent Dehumidifier with Humidistat and 1.5 litres Tank USER MANUAL

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Moveable Air-conditioner User s Manual

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

EH0554 Indoor Climate Control

OPERATING INSTRUCTIONS

Owner s Manual Super-Slim Four-Way Cassette

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

OPERATING INSTRUCTIONS

Premium Low Energy Compressor Digital Humidistat Dehumidifier & Air Purifier with UV and Plasma Ionizer

USER MANUAL TPS-M5/M55/M555

PORTABLE AIR CONDITIONER (LOCAL)

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

EH0533 Indoor Climate Control

PC20-AMFII / PC40-AMF USER MANUAL

1.6kW Window / Wall Air Conditioner

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Portable Air-conditioner Use and Care Manual

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Transcription:

AC12 AC12HP Portable Air Conditioner USER MANUAL

Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximise this product s performance. For over 60 years Amcor has specialised in complete indoor environmental control, manufacturing and marketing; dehumidifiers, portable air conditioners, coolers, air purifiers, ionisers and aroma therapy scent diffusers. These world class products incorporate the latest technological developments. QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors Near water If the power cable wires are frayed or cut Where small children may be left unattended If an extension lead may become overloaded Where it may be damaged by chemicals Where the power cable may be damaged Where there is a risk of interference by foreign objects On a slope or uneven surface This product is not for DIY repair Where there is a risk of fire, or close to a naked flame Where there is a risk of water falling on the unit

IMPORTANT Carefully read the instructions before operating the unit. This appliance is for indoor use only. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with the regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. This air conditioner has been tested and is safe to use. However, as with any electrical appliance - use it with care. Disconnect the power from the appliance before dismantling, assembling or cleaning. Avoid touching any moving parts within the appliance. Never insert fingers, pencils or any other objects though the guard. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects or edges. A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty. 3

Do not use the appliance for any purpose other than its intended use. The air conditioner must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. Avoid restarting the air conditioner unless 5 minutes have passed since being turned off. This prevents damage to the compressor. Never use the mains plug as a switch to start and turn off the air conditioner. Use the provided ON/OFF button located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms. Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills. For maximum performance the minimum distance from a wall or objects should be minimum 50cm. Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality. For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting. To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35. 4

1. Control Panel 2. Air outlet 3. Self closing louvres 4. Castors 5. Upper filter frame 6. Exhaust outlet 7. Lower filter frame 8. Rubber stopper 9. Drain screw cap 10. Power cord Check that all accessories are in the box and please read the instructions manual before assembling the unit. 1. Extendable slide bar 2. Screw, washer, nut (for slide bar) 3. Extendable exhaust hose (up to 1.5 meters) 4. Hose connector 5. Fishtail adapter 6. 10mm Drain pipe (AC12HP only) 7. Drain connector (AC12HP only) 8. Remote control 5

INSTALLATION Warning:Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must be kept upright and then placed on an even surface. 1. Extend one end of the hose and connect the hose connector, by twisting it a number of full rotations. 2. In the same way connect the fishtail adapter to the opposite end of the exhaust hose. 3. Twist the hose connector into the exhaust outlet on the rear of the unit. INSTALLATION OF WINDOW KIT 2. Make sure the unit is upright and there are no obstructions to the air inlet grills. NOTES: 3. With the hose and fishtail adaptor connected to the unit, push the end of the fishtail adaptor into the slot in the slide bar. 6 The window kit (slide bar and fishtail) can be used with sliding windows and doors. For other types of window, the fishtail should be used on its own. 1. Partially open the window and then fix the window kit to fill the opening in the window. To ensure efficient operation the opening should be as small as possible. The best form of installation is through a wall duct. The unit will need to be externally in heating mode (AC12HP only), ideally through the wall. By properly venting you expel cold air from your room while efficiently heating it. Your air conditioner should be used without a vent hose in dehumidifier mode. Please ensure an external water tank is used, monitored and regularly emptied before over spilling. Permanent plumbing can be also installed in dehumidifier mode, alternatively an external water pump can be fitted for unattended use. IMPORTANT SAFEGUARDS The length of the soft hose extends from 28 cm to 150 cm. If the hose is extended above this length the unit may malfunction and this can invalidate the warranty. The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat. Avoid bending the hose more than 30.

FEATURES AND OPERATION FEATURES 1. Self-evaporative system - no external water tank needed 2. Designer inspired luxury model 3. Louvres outlet closes when shutting down the unit, this prevents dust and dirt entering the machine. 4. Bright LED screen, indicates temperature and operation mode 5. On/Off timer function allows you to choose when the unit operates. 6. Compressor protection technology OPERATION ON/OFF Press POWER to switch the unit On or Off COOLING MODE After the machine is turned on, it will automatically enter cooling mode with a desired temperature of 22 and low fan speed. Press MODE to select cooling mode, the cooling mode indicator will be lit. Press the UP and DOWN buttons to adjust the desired temperature (between 16 and 31 ). Press SPEED to select the fan speed (high, medium and low). HEATING MODE (AC12HP) Press MODE to select heating mode, the heating mode indicator will be lit. Press the UP and DOWN buttons to adjust the desired temperature (between 16 to 31 ). Press SPEED to select fan speed (high, medium and low). DEHUMIDIFY MODE Press MODE to select dehumidify mode, the dehumidifying mode indicator will be lit. When using dehumidify mode the sleep function cannot be used and the fan speed is low. The dehumidifier does not need to be externally vented, but continuous drainage should be set up for the moisture collected. FAN MODE Press MODE to select fan mode, the fan mode indicator will be lit. Press FAN to select fan speed (high, medium and low). Desired temperature and sleep function cannot be used. TIMER MODE You can only set the auto-shut off timer while the unit is operating (On). You can only set the auto-start timer while the unit is in standby (Off). Under standby mode, press TIMER to setup the power-on time. The timer indicator turns will be lit. Under power-on mode, press TIMER to setup power-off time. The timer indicator turns will be lit. Use the UP and DOWN buttons to adjust the duration of the timer between 1-24 hours. Timer functions cannot be repeated or combined. Manual power on / off operations will cancel the timer. 7

FEATURES AND OPERATION SLEEP MODE While in cooling pressing the SLEEP button will put the unit in sleep mode. The fan speed will change to low. It will automatically increase the desired temperature by 1 after an hour and by a further 1 after a further hour. This means the unit will spend less time with the compressor running, and so run quieter. The sleep function cannot be used in dehumidify and fan modes. If the water tank is filled, the unit is put into standby or the mode is changed, sleep mode will be cancelled. SWING MODE After machine turns on, press the SWING button, the inner louver will swing continuously left and right; by pressing the button again the movement will stop and the louver remain in that position. COMPRESSOR PROTECTION There is a 3 minutes compressor start delay after power on or restart. REMOTE CONTROL 1. Power : Press to turn the unit on/off. 2. TIMER :Press to set the timer. Once set, selected duration will flash 5 times as confirmation. Under power-on or standby mode, press this button to setup the on/off timer between 1~24. 3. Down : Press to decrease the desired temperature, or the timer duration after pressing the timer button. 4. Mode : Press to choose between cooling, heating (AC12HP only), dehumidifying or fan modes. 5. Up : Press to increase the desired temperature, or the timer duration after pressing the timer button. 6. Fan : Press to change between low/medium/high fan speeds. 7. Sleep : (Only in cooling mode) :Press to enable sleep mode. 8. Swing : Press to control swing function. The air conditioner responds to all signals that are sent by the remote control. Two AAA-batteries are required to use the remote control. Note: the air flow direction cannot be adjusted with the remote control. IMPORTANT: There is a 3 minutes delay on power on. In order to protect the life of the compressor and electronic components please do not switch on the unit for at least 5 minutes after you turned the unit off. 8

WATER-DRAINAGE MANUAL DRAINAGE When the internal water tank is full the unit will stop working. Shut off the unit and unplug. Avoid moving the model abruptly as this may cause water to spill from the internal tank. Place a tray under the water plug. Unscrew the Drain plug cap and remove the rubber stopper - water will drain from the internal tank. Put the rubber stopper back and screw the drain plug cap back into place. Rubber stopper Drain plug cap CONTINUOUS DRAINAGE: Unscrew the drain plug cap and remove the rubber stopper. Fit the drain connector within the cap Connect a suitable pipe to the water outlet to remove the water out continuously. Note: This model is self-evaporative, which reduces the need to empty the water tank. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the selfevaporate facility. Drain connector Drain plug cap Drain pipe (size: 10 mm) MAINTENANCE CLEANING Turn off the unit and unplug from the mains before cleaning or performing any maintenance. CLEAN THE SURFACE Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. AIR FILTER CLEANING Clean the air filters every 2 weeks. If the air filter is blocked with dust, the performance of the unit will be significantly affected. Pull out the top and bottom filters as pictured below Wash the air filters by immersing them in warm (about 40 ) water with a neutral detergent. Rinse it and then dry it thoroughly. Carefully re-install air filters END OF SEASON MAINTENANCE 1. Pull out the plug from the drainage hole and empty the internal tank. You should ensure the tank is fully drained by leaning the unit backwards. 2. Then switch the unit to Fan mode, 3. Keep the unit in this mode for half day. Doing this helps to keep the inside of the unit dry and prevents mold developing 4. Turn off the unit and unplug 5. Ensure the water tank is empty before replacing the rubber bung and drain cap. 6. Coil the wire and bind it together, then put it into the accessories space. 7. Separate the air-exhausted pipe and store it safely. 8. Cover the unit and keep it in a dry place. 9. Take the batteries out of remote control and store, or dispose, them safely 9

TROUBLESHOOTING Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Problem Reason Solution The unit does not work The unit does not seem to perform. No power supply. Plug in and turn on the unit. Water-full indicator illuminated. Drain the internal water tank. Timer function is active. Cancel the timer function. Room temperature too low or too high. Use only in ambient temperatures between 7-40. In direct sunlight. Windows or doors open. Large amount of people or a heat source in the room. Filter is very dirty. Air inlet or air outlet is blocked Room temperature is lower than the desired temperature set. Draw the curtains, UV affects use air conditioner. Close windows and turn on another air conditioner. Clean or change the air filter Clear out debris. Change the desired temperature. The unit is loud The unit is not on a flat surface. Put the unit on flat surface. Place a piece of carpet under the unit to prevent vibrations. Compressor does not work Remote control doesn t work E1 on LED Overheating protection is active. Operating distance is too far. Control panel has not received the signal from remote control. The batteries are flat. Room temperature sensor is abnormal. Check the vent pipe is not restricted. Restart the unit after 10 minutes when compressor has cooled. Move remote control closer to the unit and make sure it aims at the air-outlet grille. Replace the batteries Temperature not within 5-40 operating range. If the temperature within operating range refer to the retailer or manufacturer. E2 on LED Coil temperature sensor is abnormal. Refer to the retailer or manufacturer. OTHERS Water tank is full inside the machine Anti-freezing protection. No refrigerant or there is very little refrigerant. High pressure protection. Drain water from drain port at bottom rear of the unit. Defrosting the coils within the unit. Normal operation will resume automatically. No user input is required. Refer to the retailer or manufacturer. After inside gas pressure comes down, it will function normally. No user input needed. If the above solutions do not resolve the problem please contact the retailer or manufacturer. 10

APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres. TECHNICAL DATA Model 11 AC12/AC12HP Cooling Capacity KW/BTU 3.51/12000 Heating Capacity KW/BTU 2.93/10000 Cooling Rated Input W 1500 Heating Rated Input W 1270 Mains 220-240 V / 50 Hz Current Cooling / Heating A 5.97/5.62 Refrigerant R410A Moisture Removal L/Day 50 EER Rating Permitted Excessive Operating Pressure Suction / Discharge MPa 0.8/3.2 Maximum Allowable Pressure MPa 5.0 Compressor A Rotary Fan Speed 3 Noise db(a) Sound Pressure Sound Power Thermostat 16-31 Timer h 1-24 Type: FSD / 50F Fuse Parameter Voltage: AC 250V;F;3.15AL Net Weight kg 29 Dimension(L*D*H) mm 400 x 370 x 800 Unit must be vented outside when in Air Cooling mode. For the purposes of EU regulation EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy 54 65

AMCOR UK SUPPORT Please, for your own convenience, make these simple checks before calling the service line. Has the unit been standing upright? (for at least 2 hrs) Is the unit plugged into the mains? Is the fuse OK? Switch the unit on and wait three minutes to see if the issue is resolved. Check whether the water tank is full. If the unit still fails to operate call: 0871 620 1057 Office hours: 9AM - 5PM Monday to Friday Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA 12