PRODUCT OVERVIEW. Dehumidifiers

Similar documents
Heat pump systems and Chillers

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE Dehumidifiers for radiant cooling systems with heat recovery

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

> > > Heat pump systems. Water Chillers. Dehumidifiers

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

G E N E R A L C ATA L O G Dehumidif ers

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

FH - GH Dehumidifiers for radiant cooling systems

ERGON EQUIPMENT SA PRESENTATION

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

High efficiency air to water Heat pumps LZT series

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

recooler HP EQKR HEAT PUMP

CHAPTER 4. HVAC DELIVERY SYSTEMS

50A KP 70A KP 90A KP 120A KP 150A KP 210A

CDP 40 SWIMMING POOL DEHUMIDIFIER

LZT High efficiency air to water heat pumps with E.V.I. compressors

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Air-Cooling Evaporators

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control


CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Nordic Heat Pump Product Guide

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

HVAC Fundamentals & Refrigeration Cycle

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

Heat pump and energy recovery systems

R07. Answer any FIVE Questions All Questions carry equal marks *****

Liquid Desiccant Air Conditioning Systems

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

The Energy Mist System

GAS ABSORPTION HEAT PUMP

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

S-Therm Air to Water Heat Pumps

Air Conditioners. Summer

100% Outdoor Air Dehumidification Methods

ALFAMINI-ALFAMAX Central Station air handling units high efficiency for wellness areas

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Pressure Enthalpy Charts

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Air Conditioning Inspections for Buildings Condensers

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

DEHUMIDIFIERS & VENTILATORS

DAISHIBA Heating & Refrigeration Equipment Co., Ltd

Pool dehumidification. Airpool+

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

ASTRALPOOL HEAT PUMP CATALOGUE

Cozy Hi Wall Inverter Air conditioner

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

ThermoSaver TM Hot Gas Defrost System

COOLflow 4E PRODUCT RANGE

IDU22C, 22C1, 37C, 37C1, 55C, 75C

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Close control air conditioning

CRIMSON & CRIMSON MAX

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

Cozy Hi Wall Inverter Air conditioner

Midwest Industrial Initiative Webinar: Industrial Refrigeration

To Keep Docs Cool, Dry and Happy

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

ASTRALPOOL HEAT PUMP CATALOGUE

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

Transcription:

PRODUCT OVERVIEW Dehumidifiers

IdROS was formed in 1993 as a distribution company operating in the humidification and dehumidification sector of the air conditioning market. The expansion was rapid and, as the knowledge of the market sector increased, opportunities for the development of specialist products were identified. The decision was therefore taken in 2001 to invest in a production facility and to manufacture their own design products. Since then, the company has added chillers, heat pumps and air handling units to its product portfolio. Today, IdROS with its qualified staff, designs, develops and tests heat pumps, water chillers, dehumidifying systems and air handling units all based on the refrigerant cycle. The total range of idros products includes standard dehumidifiers with capacities from 25 to 3000 l/24h and heat pumps and water chillers with cooling and heating capacities from 5 to 900 kw. In addition to this, IdROS can offer a wide range of tailor made machines to meet any customer requirement. Expertise, quality, flexibility and enthusiasm are the other essential elements of the company that ensure we provide a rapid response with appropriately engineered solutions. 2

eat pumps igh efficiency air source and ground source heat pumps using state-of-the-art technology. Ranges from 10 kw to 200 kw (air source) and 7 kw to 660 kw (ground/water source). Dehumidifiers Dehumidifiers for use in swimming pools, cold rooms, industrial applications and passive cooling systems. Water Chillers Air cooled and water cooled packaged chillers to 1 MW capacity for both external and internal installation. Free cooling, split condenser and condensing unit versions also available. www.hidros.eu

What is umidity? The air we breathe contains water vapour the majority of which comes from the evaporation of water from lakes and oceans. This vapour is what we commonly describe as humidity. umidity is a basic requirement in various sectors of human activities but it is also an invisible element that can cause serious damage to processes and products. Why Control umidity? The control of humidity suppresses the growth of moulds thereby resulting in a healthier environment. It reduces corrosion problems, increases the reliability of electric and electronic components, increases the preservation time of foodstuffs, improves environmental comfort and removes obnoxious odours. Versions Base unit Unit with desuperheater In these versions, the air leaving the unit is always warmer than the incoming air. The thermal power generated by the unit depends on the thermo-hygrometric conditions of the environment. In these versions the air leaving the unit is in neutral thermal conditions. The exceeding thermal power is disposed of by the air or water desuperheater, placed on the unit and connected to the outside of the environment to be treated. 4

ow a Dehumidifier works There are several methods to reduce the content of water vapor in the air. idros products provide dehumidification by condensation of the moisture using the refrigerant cycle. The method of operation is as follows. Firstly, the air is drawn in and passed through a cold finned coil. Inside the coil is cold refrigerant in a liquid/gas mixture. eat is absorbed Form the air to change the remaining liquid to gas. Absorbing heat from the air cools It to the dew point where it cannot contain the water vapour within it and this therefore condenses in the form of drops on the fins of the evaporator. The liquid water thus produced is collected in a condensate tray and is drained via a discharge pipe. The air is now cold and at saturation point, it must be heated back to room temperature. The energy that was absorbed from the air is present in the refrigerant gas and this, plus the electrical energy powering the unit, heats the refrigerant which is passed to a finned condensing coil. The cold, saturated air is passed over this coil and is heated. As its temperature rises, it expands and, because a lot of its moisture has been removed, is supplied in a warm, dry condition. Compressor Evaporator Fan Condenser Expantion device Unit with remote condenser Unit with Alpha cycle I A Fresh air Exhaust air E C D G B F In these versions there are two condensers: one air cooled and one water cooled, both mounted on the unit. The water condenser must be connected to an external source. The air leaving the unit can be cooled or heated by alternately activating the two capacitors; - Air cooled condenser activated: Air Dehumidified and heated - Water cooled condenser activated: Air Dehumidified and cooled. To increase the dehumidification capacity, particular systems are used that increase the value of specific dehumidification with the same air flow rate introduced into the room. These systems are called alpha-cycle systems. On average, an alpha cycle allows you to have from 20% to 30% more dehumidification capacity compared to a traditional dehumidifier, with the same amount of air flow treated. www.hidros.eu

Residential Applications It s perhaps dehumidifier s best known application: especially in the winter season such devices are used to remove moisture from humid environments with the presence of mold and poor ventilation. A typical case is the cellar or underground rooms where such equipment can also be used during the whole year. In such applications, the dehumidifier is widely used in the drying clothing in the winter time that in addition to decrease the content of water vapor in the air, as has been said previously, this unit also causes the relative heating, facilitating further thus the transfer by clothing of water vapor and subsequent drying. Another application of some importance in residential sector is drying screeds in the building, or drying environments after flooding. The use of a dehumidifier in this case accelerates the drying process in a very substantial, significantly reducing recovery times. Another application of great spread are the gyms, where in the winter period, given the considerable influx of people, the relative humidity reaches a level often intolerable. Industrial Applications idros dehumidifiers are used in a wide range of industrial applications: the plastics industry, paper, wood, packaging, the glass industry, marble industry. In all these areas, the common denominator is that the humidity must be maintained within certain levels so that the industrial process can be carried out successfully. The operating temperatures can be the most diverse and range from a few degrees above zero until reaching 50-60 C. The values of relative humidity may vary from 15-20% up to 50-60%. Due to this wide range of operating range used, they do not always have the same configuration, but have specific design depending on the concerned application. The sizing is therefore carried out according to the specific needs required by the application in question, that generally is a function of the value of temperature and humidity to ensure, the correct amount of water to be removed, the air flow rate and to ensure the duration of the production cycle. Pools and Wellness The water contained in indoor pools is generally heated to 27-28 C and this induces a high evaporation. The amount of steam is generally produced from a square meter of pool can vary from 100 to 250 g / h, depending on its temperature and physical activity of people present. To prevent any problems of condensation on the cold walls of the enclosure, or corrosion due to the presence of disinfectant agents in the water, it becomes necessary the installation of a dehumidification system. In most applications the dehumidifier integratesthe heating system of the air already present, in other systems it acts as a complete air handling unit enabling even the winter heating, summer cooling, heat recovery and fresh air treatment. 6

www.hidros.eu

F - G Dehumidifiers for radiant cooling systems R407C R134a Available versions WZ Units supplied with double condenser (the first is an air condenser, the second is a water one) and of a logic which allows the dehumidification with neutrum air or with cooled air. Operation limits Room relative humidity (%) 100 90 80 70 60 50 40 Room relative humidity (%) 100 90 80 70 60 50 40 Dehumidification Ventilation 30 10 20 30 40 30 0 10 20 30 40 50 60 Models F Moisture removed (1) Cooling capacity (1) Total power input (1) Water flow Air flow Dimensions (xpx) Air Temperature ( C) Water Temperature ( C) 25 25WZ l/24h 20,1 20,1 W --- 1250 W 360 360 l/h 150 150 m 3 /h 250 250 mm 545x223x681 545x223x681 Models G 25 25WZ 50 50WZ 100 100WZ 200 200WZ Moisture removed (1) l/24h 20,1 20,1 48,5 48,5 87,2 87,2 164,0 164,0 Cooling capacity (1) W --- 1250 --- 3500 --- 6000 --- 11300 Total power input (1) W 340 340 700 700 1450 1450 2450 2450 Water flow l/h 150 150 500 500 600 600 900 900 Air flow m 3 /h 250 250 600 600 1000 1000 1850 1850 Dimensions (xpx) mm 582x582x257 582x582x352 730x800x392 930x888x464 (1)Room temperature 26 C; relative humidity 65% with cold water coil water inlet temp. 15 C. 8

GE - FE Dehumidifiers for radiant cooling systems with heat recovery R410A R134a Available versions STD The dehumidifiers with heat recovery of high efficiency were designed to provide dehumidification and fresh air in a residential area with very high energy efficiency, combined with radiant cooling systems. The units have been designed to grant the dehumidification either under conditions of thermally neutral air or in terms of air-cooled, managing small air flow thus avoiding annoying tiny air currents typical of traditional air conditioning systems. FC Free Cooling: allows the air to avoid unnecessary switching on the cooling circuit, thus granting excellent environmental conditions with high energy savings. The Free Cooling option is perfect in the middle seasons, when heating or cooling systems are not in use. Return Air (max. 50%) Return Air W.C. (max. 50%) Supply Air 100% Fresh Air (max. 50%) Exhaust Air (max. 50%) Models Useful dehumidification capacity (1) Total cooling Power (latent + sensible) (1) Efficiency winter recovery (2) Efficiency summer recovery (1) Compressor absorbed power (1) Outdoor air flow flow Dimensions (xpx) GE 26 GE 26FC GE 51 FE 26 l/24h 30,1 30,1 61,8 30,1 W 1380 1380 2820 1380 % 90 90 90 90 % 75 75 72 70 W 340 340 480 340 m 3 /h 80-130 80-130 140-250 80-130 m 3 /h 130-260 130-260 250-500 130-260 mm 732x1105x260 732x1355x260 835x1370x400 600x440x1125 (1) Room Temp. 26 C; 65% RU; Ambient Temp. 35 C; 50% RU; Fresh Air System volume 130 m 3 /h (GE26),250 m 3 /h(ge51); Water IN 15 C, Water Flow 250 l/h(ge26), 350l/GE51) - (from the net hygroscopic content of the external air). (2) Ambient Temp. -5 C; 80% RU, Room Temp. 20 C; 50% RU, maximum external air fllow. www.hidros.eu

BA - A Industrial dehumidifiers Inverter R407C R410A R134a Available versions BA A With cabinet. BA P Ductable vertical unit. AEVI Ductable horizontal unit. DC INVERTER Operation limits COP 4,1 R (%) 100 90 80 Dimensions P P 70 60 50 P 40 30 0 5 10 15 20 25 30 35 40 BA/A BA/P Room temperature ( C) A Model BA/A-P Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Moisture removed at 20 C - 60% Maximum input power Air Flow Dimensions BA/A (xpx) Dimensions BA/P (xpx) Model A Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Moisture removed at 20 C - 60% Maximum input power Air Flow Dimensions BA/A (xpx) 10 50 75 100 150 200 l/24h 40,1 56,6 77,3 113,1 143,5 l/24h 35,6 50,7 68,9 96,6 131,7 l/24h 25,8 35,6 51,3 71,5 96,6 kw 1,2 1,5 2,0 2,3 3,1 m 3/ h 500 800 1000 1400 1650 mm 760x260x750 1060x260x750 1060x260x750 1310x310x836 1310x310x836 mm 706x250x680 1006x250x680 1006x250x680 1255x300x770 1255x300x770 50 75 100 150 200 l/24h 39,0 56,7 77,4 118,3 146,7 l/24h 34,9 50,1 69,1 104,4 129,5 l/24h 25,6 35,4 50,7 75,7 92,5 kw 1,2 1,5 2,0 2,3 3,1 m 3/ h 500 800 1000 1400 1650 mm 710x700x360 900x980x460 900x980x460 1050x1160x530 1050x1160x530

Plant scheme BA A BA P A www.hidros.eu

DA - MA Industrial dehumidifiers R410A Available versions MA Z MA BT These versions are supplied with an air condenser and are used in those applications where it is necessary the simultaneous control of temperature and humidity. The units are supplied with a specific refrigerant circuit design to operate with a wide range of temperatures, they are also equipped with hot gas injection system (used to defrost the evaporator) and condensate discharge drip tray equipped with antifreeze heater, in case of operation in low ambient temperature conditions. Operation limits Dimensions R (%) 100 90 P 80 70 60 50 40 30 0 5 10 15 20 25 30 35 40 Room temperature ( C) Model DA Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Moisture removed at 20 C - 60% Maximum input power Air Flow Dimensions (xpx) Model MA Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Moisture removed at 20 C - 60% Maximum input power Air Flow Dimensions (xpx) 12 75 100 150 200 250 l/24h 56,6 76,5 111,0 145,3 190,3 l/24h 49,4 68,5 99,7 127,8 169,5 l/24h 34,5 50,2 66,6 90,6 122,4 kw 1,59 2,05 2,68 3,44 4,39 m 3/ h 800 1000 1500 1800 2000 mm 400x800x800 400x800x800 550x1060x1000 550x1060x1000 550x1060x1000 270 350 450 550 750 950 l/24h 185,1 262,3 336,3 425,0 596,4 759,7 l/24h 161,4 233,5 302,0 375,7 534,3 680,3 l/24h 111,4 168,5 223,9 267,1 391,0 501,0 kw 7,50 7,99 9,85 10,30 15,60 20,10 m 3/ h 3500 4200 4200 5500 7000 8500 mm 704x1154x1378 704x1154x1378 704x1154x1378 854x1504x1750 854x1504x1750 854x1504x1750

Outdoor Unit (Z) Possible configurations ASRI ASVE ASE www.hidros.eu

SBA - SA Swimming pool dehumidifiers R410A Available versions SBA A SBA P SA With cabinet. Ductable vertical unit. Ductable horizontal unit. Operation limits R (%) 100 90 80 Dimensions P P 70 60 50 P 40 30 10 15 20 25 30 35 40 SBA/A SBA/P Room temperature ( C) SA Model SBA/A-P Moisture removed at 30 C - 80% Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Nominal input power Air Flow Dimensions SBA/A (xpx) Dimensions SBA/P (xpx) Model SA Moisture removed at 30 C - 80% Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Nominal input power Air Flow Dimensions (xpx) 14 50 75 100 150 200 l/24h 49,0 73,0 95,0 155,0 190,0 l/24h 40,1 56,6 77,3 113,1 143,5 l/24h 35,6 50,7 68,9 96,6 131,7 kw 0,9 1,2 1,6 1,9 2,5 m 3/ h 500 800 1000 1400 1650 mm 760x260x750 1060x260x750 1060x260x750 1310x310x836 1310x310x836 mm 706x250x680 1006x250x680 1006x250x680 1255x300x770 1255x300x770 50 75 100 150 200 l/24h 49 73 95 155 190 l/24h 39,0 56,7 77,4 118,3 146,7 l/24h 34,9 50,1 69,1 104,4 129,5 kw 0,97 1,29 1,76 2,07 2,74 m 3/ h 500 800 1000 1400 1650 mm 710x700x360 900x980x460 900x980x460 1050x1160x530 1050x1160x530

Plant scheme SA SBA P SBA A www.hidros.eu

SDA - SMA Swimming pool dehumidifiers Inverter R407C R410A R134a Available versions SDA The series includes 5 models with air flows from 800 to 2000 m 3 /h. SMA The series includes 6 models with air flows from 3800 EVI to 8500 m 3 /h. DC INVERTER COP 4,1 Operation limits Dimensions R (%) 100 90 80 P 70 60 50 40 30 10 15 20 25 30 35 40 Room temperature ( C) Model SDA Moisture removed at 30 C - 80% Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Maximum input power Air Flow Dimensions (xpx) Model SMA Moisture removed at 30 C - 80% Moisture removed at 30 C - 60% Moisture removed at 27 C - 60% Maximum input power Air Flow Dimensions (xpx) 16 75 100 150 200 250 l/24h 73,0 95,2 157,1 194,3 240,2 l/24h 56,6 76,5 111,0 145,3 190,3 l/24h 49,4 68,5 99,7 127,8 169,5 kw 1,59 2,05 2,68 3,44 4,39 m 3/ h 800 1000 1500 1800 2000 mm 400x800x800 400x800x800 550x1060x1000 550x1060x1000 550x1060x1000 270 350 450 550 750 950 l/24h 263,1 340,2 418,8 566,8 751,1 939,3 l/24h 185,1 262,3 336,3 425,0 596,4 759,7 l/24h 161,4 233,5 302,0 375,7 534,3 680,3 kw 7,50 7,99 9,85 10,30 15,60 20,10 m 3/ h 3500 4200 4200 5500 7000 8500 mm 704x1154x1378 704x1154x1378 704x1154x1378 854x1504x1750 854x1504x1750 854x1504x1750

Outdoor Unit (Z) Plant scheme Possible configurations ASRI ASVE ASE www.hidros.eu

SR Swimming pool dehumidifiers Inverter R407C R410A Available R134a versions Operation limits WZ EVI DC INVERTER COP 4,1 Unit with heat recovery: The unit is designed to have one refrigerant circuit condensed by air, the other one condensed both by water and air. If the unit is supplied with the advanced control panel it is possible to set operation priorities (air or water). In the SR/WZ versions the heat recovery is designed to reject on the water about 50% of the total thermal load generated by the unit. When the heat recovery is activated, the supply air temperature of the unit is, basically, the same of the return air, so,in this case, the dehumidification is performed without air temperature increase. This operation mode is suitable during intermediate seasons when the humidity in the swimming pool has to be controlled but also the room air temperature overheating has to be avoided. R (%) 100 90 80 70 60 50 40 30 10 15 20 25 30 35 40 Room temperature ( C) Standard version WZ version G G F F A A B B I G G F F B E A A B C D I A B C D E F G I Compressor Expansion valve Solenoid valve eat recovery One way valve Evaporator Air filter Condenser ot watercoil (accessory) Fan SR Models Moisture removed 30 C - 80% Nominal input power 30 C - 80% Air flow Dimensions (xpx) 1100 1300 1500 1800 2200 3000 l/24h 1130 1285 1480 1855 2310 3050 m 3 /h 19,9 23,6 26,8 36,3 41,8 55,8 m 3 /h 9500 10500 13000 15000 17000 25000 mm 850x1870x1250 850x1870x1250 1105x2608x1566 1105x2608x1566 1105x2608x1566 1105x3608x1566 18

UTA Energy recovery high efficiency dehumidifiers R410A Available versions Dimensions UTA The energy recovery high efficiency dehumidifiers UTA range have been designed to grant the complete control of temperature, humidity, the energy recovery and the fresh air treatment in the covered swimming pools or in other applications with very high internal loads. The use of double-passagecross-flow energy recovery allows to increase up to 30% the dehumidification capacity in comparison to the traditional dehumidifiers. P UTAZ Version with temperature control: These versions are supplied with a remote condenser and are used in those applications where it is necessary the simultaneous control of temperature and humidity: Dehumidification mode: the internal condenser is activated; the unit dehumidifies and heats up the room temperature; Cooling mode: the remote condenser is activated; the unit dehumidifies and cools down the room temperature. Operation limits Room air relative humidity (%) 100 90 80 70 60 50 40 30 10 Standard operation 15 20 25 30 35 40 Room air temperature ( C) Room air temperature ( C) 40 35 30 25 20 15 10 5-20 Operation with DBRC Standard operation -10 0 10 20 30 40 Fresh air temperature ( C) UTA Models Moisture removed (1) Total air flow Maximum fresh air flow Dimensions (xpx) 015 020 028 035 042 052 060 l/24h 223,0 290,9 444,8 552,2 587,5 746,4 907,5 m 3 /h 1500 2000 2800 3500 4200 5200 6000 m 3 /h 450 600 845 1050 1260 1560 1800 mm 1000x640x1770 1000x640x1770 1500x750x1850 1500x750x1850 1950x1250x1950 1950x1250x1950 1950x1250x1950 (1) Room temperature 30 C; relative humidity 60%, fresh air 30% (-5 C 80%). www.hidros.eu

BROD.18GB.A Technical data shown in this booklet are not binding. IdROS Srl shall have the right to introduce at any time whatever modifications necessari to the improvement of the product.