Technical Information OUSTF10

Similar documents
Technical Information OUSTF10

Technical Information OUSAF12

Technical Information OUSAF22

Technical Information OUSAF44

Technical Information OUSAF21

Operating Instructions OUSTF10

Technical Information OUSBT66

Operating Instructions OUSAF12

Technical Information OUSBT66

Condumax CLS16 and CLS16D

X56 Series Photometric Detectors

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Instruction Manual. optek-sensors AF56. optek-danulat GmbH Emscherbruchallee Essen

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

Operating Instructions Condumax CLS15/16/21

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

Application Overview: SmartSwitch

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Ultrasonic Level Measurement nivopuls FDU 10 S

Turbimax CUE21 / CUE22

Features and Benefits

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Features and Benefits

Flow Measurement SITRANS F C

Model TF56-N Sensor. 1. Using the instruction manual. 2. Returns and disposal. 3. Intended use. 4. Description of the TF56-N sensor

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Bristol Babcock Oil Content Monitor "oil in water"

Operating Instructions Indumax CLS54D

OPTISENS TUR 2000 Technical Datasheet

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

OMA-300 Process Analyzer

CLARITY II TURBIDIMETER

PUV, PIR and PFO Series BROCHURE

COMPACT FLAME CONTROLLER CFC 1000

Safety vacuum drying oven for flammable solvents

Turbimax CUE21 / CUE22

COMPACT FLAME CONTROLLER CFC 2000

GAS DETECTOR ST400EC PART.NO

SIMRAD GD10PE IR GAS DETECTOR

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Level Measurement Continuous level measurement Ultrasonic transmitters

Dräger Polytron Pulsar 2 Open Path Gas Detector

Flow Measurement SITRANS F C

Technical Specification VFD

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Environmentally Safe No Emissions

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

PureLine D. Technical Specification

WEDECO Quadron UV System

Lamp Supply (Recommended)

MagMaster MFE flowmeters feature an innovative multifrequency

Air operated diaphragm pumps. Catalogue 2011 rev 1

Dräger Polytron 5700 IR Detection of flammable gases and vapours

providing the perfect mix

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

SIMRAD GD10 IR GAS DETECTOR

Moisture and Hydrocarbon Dew Point Measurement

818 Series Low-Power Detectors

Ar-Mite TM Low Flow Armored Flowmeter

Prosonic S FDU91/91F/92/93/95/96

APPLIED. OMA-406R Rackmount Process Analyzer

Micro/Ultra Filtration System StamoClean CAT 430

SITRANS T temperature transmitters A broad product family for every application. sitrans

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Gas cylinder scale Model GCS-1

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Conductivity Electrode LRG Original Installation Instructions English

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Gas cooler series TC-Standard+ X2

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

General Specifications

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

PRODUCT DATA SHEET ilh8

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Portable central unit for several parameters

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

for Drinking Water Systems

Transcription:

TI00500C/07/EN/01.13 71157320 Products Solutions Services Technical Information Optical sensor combined with flow assembly OUA260 for measurement of turbidity and non-dissolved solids Application The scattered light turbidity sensor is used for measurement of nondissolved solids, emulsions, and immiscible fluids in process liquids. The sensor operates in the VIS/NIR region of the electromagnetic spectrum. It is suitable for a variety of industries. Turbidity measurement for Quality control/purity monitoring Condensate control Turbidity in Breweries Filter control Turbidty in potable water Heat exchanger in leak detection Turbidty in brine Your benefits Accurately measures low level particulates up to the equivalent of 0 to 200 FTU formazine or 0 to 200 ppm Diatomaceous Earth, using scattered light detection at 11 angle from excitation beam FM and ATEX approved explosion proof lamps for hazardous area applications Low voltage incandescent lamp provides long dependable life The can be fitted with long pass NIR filter to minimize color related measurement errors The OUA260 flow assembly used with the sensor offers the following benefits: Broad variety of wetted materials provides resistance against any process medium Flexible process adaptation with various process connections Hygienic versions with certified materials and SIP/CIP-resistance Air purge ports available for preventing condensate formation on the optical windows Pyrex windows deliver accurate and reproducible performance under industrial conditions, Quartz or Sapphire optional

Function and system design Measuring principle General Information Turbidity is the visual appearance of a liquid containing suspended solids. The presence of these solids causes light to be scattered and absorbed, making the liquid appear 'turbid'. The amount of light that is scattered or absorbed in a liquid can be used in a measurement system to determine the actual level of turbidity. The simplified optical diagram below illustrates the basic principles of scattering measurements. A focused parallel beam of light is projected through the liquid. This beam is called the Direct Beam and is measured by the Direct Light detector. If the fluid in the sample cell is free of particles, then all light projected from the lamp is seen by the Direct Light detector. If particles are present in the fluid, then light is scattered in all directions, most of the scattering taking place in a forward direction. The optical system was designed to measure scattered light centered around 11 angle in the forward direction. This viewing angle of the Scatter Light detector assures that the maximum available scatter signal is detected. 4 3 6 2 5 1 7 8 Simplified forward scatter optical diagram 1 Lamp 2 Aperture lenses 3 Optional long pass NIR (780 nm and above) 4 Sample area 5 Scatter beam 6 7 8 A0016789 Scatter beam detector Direct beam detector Anti-reflection coated broad band neutral density filter Options Installation in hazardous areas The explosion-proof lamp housing allows for installation in hazardous areas. This sensor version is rated for FM Class 1, Division 1, Groups B, C, D and ATEX II 2G EExd IIC T5. 2 Endress+Hauser

Measuring system A complete measuring system comprises: Transmitter Memograph CVM40 Optical sensor Flow assembly OUA260 Cable set OUK20 Example of a measuring system 1 Cable set OUK20 2 Transmitter Memograph CVM40 3 Optical sensor 4 Flow assembly OUA260 A0016746 Input Measured variable Measuring range Wavelengths Turbidity in FTU (Formazin Turbidity Units) or ppm Measuring range 0 to 200 FTU or 0 to 200 ppm DE Broadband (VIS and NIR) Long pass (780 nm and above) Optical path length 40 mm standard Endress+Hauser 3

Wiring Electrical connection The sensor is connected to the transmitter via the pre-terminated and labeled cable set OUK20 (to be ordered separately). Terminals and labeling might vary with the transmitter in use. Connecting cable for A Power supply for lamp B Signal transmission of scatter and direct detectors A0014860 Terminal CVM40 Cable OUK20 for sensor Core Assignment S1.S GY Shield S1.1 RD Sensor Scatter + S1.2 BK Sensor Scatter - S2.S GY Shield S2.1 WH Sensor Direct + S2.2 GN Sensor Direct - V1.1 YE (Bold) Lamp voltage + V1.3 YE (Thin) Lamp sense + V1.4 BK (Thin) Lamp sense - V1.2 BK (Bold) Lamp voltage - Cable length Cable connectors max. 100 m (328 ft) Nickel-plated brass 4 Endress+Hauser

Installation Installation instructions Sensors are designed for in-line use with the related OUA260 flow assembly. The flow assembly can be installed either directly in a process line or in a by-pass line. The sensor cannot be used without the OUA260. Make sure that the sensor and detector housings are horizontal. This will ensure that the optical window surfaces are in a vertical position which will help to prevent buildup on the window surfaces. Install the sensor upstream of pressure regulators. Allow adequate space for the connection of cables at the ends of the lamp and the detector housing. Operating sensors under pressure will help to avoid air or gas bubble creation. Sensor installation A Preferred B Avoid C Acceptable D Best E 1 2 Never Process flow Process piping a0007110 Environment Ambient temperature 0 to 55 C (32 to 131 F) Storage temperature -20 to 70 C (-4 to 158 F) Relative humidity 5 to 95 % Ingress protection IP 65 (NEMA 4) Endress+Hauser 5

Process Process temperature 0 to 90 C (32 to 194 F) continuous max. 130 C (266 F) for 2 hours Process pressure up to 100 bar (1450 psi), depending on material, line size and process connection of flow assembly Mechanical construction Design, dimensions The sensor dimensions depend on the flow assembly. Design of with OUA260 flow assembly 1 Lamp assembly 2 OUA260 flow assembly (to be ordered separately) 3 Detector assembly A0016754 Lamp assembly type "A" Dimension Detector assembly type "B" Dimension Standard lamp 151.3 mm (5.96") 106.7 mm (4.20") Detector and lamp may vary depending on options ordered. Flow assembly OUA260 Process connections: Tri-clamp, weld stubs, tube compression fittings, Swagelok, ANSI flange, DIN flange (further connections available on request) Materials: SS316L, Kynar (further materials such as titanium, Hastelloy, etc. available on request) Line size: ½" to 4" (DN 6 to DN 100), Sanitary connections must be 2" or larger Path length: 40 mm Windows: Quartz, Sapphire O-rings: EPDM, Viton, Kalrez, Silicone (further materials available on request) For flowcell dimensions please refer to OUA260 documentation. Make sure to leave an additional clearance of approx. 5 cm (2") at the lamp end and detector end of the sensor to allow for installation of the sensor cables. 6 Endress+Hauser

Weight Sensor Lamp housings Lamp: Hazardous lamp with SS-braided cable (1.2 m (4ft)) and junction box (FM Ex-sensor only): ATEX lamp Detector housings Detector: 0.54 kg (1.19 lbs) 3.2 kg (6.66 lbs) 1.34 kg (2.95 lbs) 0.72 kg (1.59 lbs) Flow assembly OUA260 (assembled with windows and window rings, no sensor) TC 2", 316 SS: 1.88 kg (4.15 lbs) TC 4", 316 SS: 3.38 kg (7.45 lbs) For other options please consult the Technical Information for the OUA260 flowcell. Materials Sensor housing: Stainless Steel 316L Light source Detectors Filters Collimated lamp Lamp life: Typically 10,000 hours Visible/IR enhanced silicon detectors, hermetically sealed Multilayer long pass NIR filter > 780 nm optional Certificates and approvals Ex approval ATEX II 2G EEx d IIC T5 FM Cl.1, Div. 1, Group B, C, D FDA All non metallic wetted parts as in rubber and plastics comply with FDA Regulations 21 CFR 177.2600. The plastic and elastomeric wetted parts of the sensor have passed the bio-reactivity tests according to USP <87> and <88> class VI. Endress+Hauser 7

Ordering information Product page You can create a complete and valid order code by using the configurator on the internet product page. Enter the following address to access the product page: www.products.endress.com/ Online configurator 1. You can choose from the following options on the product page located on the right: 2. Click "Configure this product". 3. The configurator opens in a separate window. You can now configure your device and receive the complete order code that applies for the device. 4. Afterwards, export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the page. Product structure The following product structure represents the status of printing. You can create a complete and valid order code on the Internet using the configurator tool. Sensor Wavelength W W/o Filter (visible range + NIR) X Long Pass NIR Y Special version, TSP-no. to be spec. Calibration 0 0-200 FTU 1 0-20 FTU 2 0-2 FTU 3 0-200 ppm DE 4 0-20 ppm DE 5 0-2 ppm DE 9 Special version, TSP-no. to be spec. Lamp B Collimated Incandescent Lamp Approval 0 Non-hazardous area 1 FM Class 1, Div 1, Groups B, C, D 2 ATEX II 2G Eex d IIC T5 Assembly A Single order / spare part B Assembled with assembly, position Y Special version, TSP-no. to be spec. - Complete order code 8 Endress+Hauser

Cable set OUK20 Sensor 1 2 OUSAF21/OUSAF22 3 OUSAF23 Transmitter A OUM900 Series B OUM600 Series C OUM700 Series D Memograph CVM40 Cable length 10 10 ft / 3 m 15 15 ft /4.5 m 25 25 ft / 7.5 m 50 50 ft / 15 m 80... ft; cable 90... m; cable Barrier A Non-hazardous area B FM Busbar C ATEX Busbar D FM DIN rail E ATEX DIN rail OUK20- Complete order code Scope of delivery The scope of delivery depends on the ordered version. Isolated order 1 detector and lamp assembly without flow assembly Operating Instructions Assembled to flow assembly Detector and lamp assembly mounted OUA260 flow assembly Operating Instructions When the sensor is ordered together with a transmitter, the complete measuring system is factorycalibrated and shipped as one package. Endress+Hauser 9

Accessories The most important accessories that could be delivered at the time this document went to print are listed below. For information on accessories that are not listed here, please contact your local service or sales representation. Flow assembly OUA260 flow assembly For sensor installation in pipe lines Materials: stainless steel 316L or Kynar (further materials available on request) Many process connections and pathlength versions available Order according to product structure, see Technical Information TI418C/07/EN always requires 40 mm optical path length Transmitter Cable CVM40 Memograph Graphic transmitter for inline photometers and data manager Order according to product structure, see Technical Information TI457C/07/EN OUK20 cable set Pre-terminated or labeled cable set for connection of sensors Order according to product structure 10 Endress+Hauser