Technical Information OUSAF44

Similar documents
Technical Information OUSAF22

Technical Information OUSAF12

Technical Information OUSAF21

Technical Information OUSTF10

Technical Information OUSBT66

Technical Information OUSBT66

Technical Information OUSTF10

Operating Instructions OUSAF12

Operating Instructions OUSTF10

Condumax CLS16 and CLS16D

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

Operating Instructions Condumax CLS15/16/21

Operating Instructions Indumax CLS54D

Specifications Wavelength Range: 190 nm to 800 nm continuous

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Laser Distance Sensor Type M Analog-Output

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Instruction Manual. optek-sensors AF56. optek-danulat GmbH Emscherbruchallee Essen

PUV, PIR and PFO Series BROCHURE

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

An FT-NIR Primer. NR800-A-006

COMPACT FLAME CONTROLLER CFC 2000

OMA-300 Process Analyzer

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

COMPACT FLAME CONTROLLER CFC 1000

SIMRAD GD10 IR GAS DETECTOR

SPECTRAL INSTRUMENTATION

Turbimax CUE21 / CUE22

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Chemical Processes in the Combustion

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SIMRAD GD10PE IR GAS DETECTOR

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Druck DPI 705/DPI 705 IS Series

Temperature Measurement Transmitters for field mounting

Application Overview: SmartSwitch

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

for Drinking Water Systems

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Equipment specifications (D6)

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Turbimax CUE21 / CUE22

sglux UV-SENSOR PROBES Catalogue

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Digital Sensors Erythema Sensor PMA2101

Intrinsically Safe Transmitters, Option Code 2n

Table of Contents. 1. Mounting Tips... 2

APPLIED. OMA-406R Rackmount Process Analyzer

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

PURPOSE OF THE PROCEDURE

Rosemount 4500 Hygienic Pressure Transmitter. Start

ProStar 325 UV-Vis Detector

Gas cylinder scale Model GCS-1

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Dräger PIR 7200 Toxic Gas Detection Transmitter

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Dräger Polytron 8000 Stationary gas detector (EC)

Understanding total measurement uncertainty in power meters and detectors

Transmission Photometer UV / VIS / NIR / IR. Reflection Photometer VIS / NIR / IR

818 Series Low-Power Detectors

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Lamp Supply (Recommended)

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

UV measurements for medical applications using SiC photodiodes

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

CALIBRATION HOW IT WORKS

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

DF1151-Ex Infrared flame detector

Flame Detection Jon Sarfas

Continuous Gas Analyzers, in-situ

Transcription:

TI00416C/07/EN/13.16 71316935 Products Solutions Services Technical Information Optical sensor combined with the OUA260 flow assembly for the measurement of UV absorption Application The sensor measures the spectral absorption of process liquids in the ultraviolet region of the electromagnetic spectrum. Measurement of protein concentrations Chromatography monitoring Filtration monitoring Concentration measurement of organic compounds Detection of aromates Your benefits Improved process control and easier quality control thanks to quick and reliable monitoring of product concentration Measuring range up to 2.5 AU or 50 OD (depending on optical path length) Measurement of UV absorption at discrete wavelengths between 254 nm and 365 nm Outstanding filter properties for highest linearity Direct concurrence with laboratory values Integrated reference detector for lamp compensation Gas discharge lamp for long service life and stable measured values Patented Easycal system (optional) Cost-effective, time-efficient calibration Easy, in-line calibration which is traceable to NIST without any liquid standards FM- and ATEX-approved lamps for applications in the hazardous area Compliance with life sciences sector thanks to hygienic design and FDA- and USPcompliant sealing materials High degree of product safety as SIP/CIP-resistant High product yield thanks to low volume requirements Maximum durability in all applications owing to wide range of materials and process connections Can be adapted to process requirements: Optional air purge ports to prevent the formation of condensate on the optical windows Optional adjuster for optical path length

Function and system design Measuring principle Light absorption The measuring principle is based on the Lambert-Beer law. There is a linear dependency between the absorption of light and the concentration of the absorbing substance: A = -loga m = ε. c. OPL A... absorption, A m... absorption measured by detector ε... Extinction coefficient c... Concentration OPL... Optical path length A light source emits radiation through the medium and the incident radiation is measured on the detector side. Once the light has passed through a filter for wavelength selection, the intensity of the light is determined by a photodiode and converted to a photocurrent. The subsequent conversion to transmission (%) or absorbance units (AU, OD) is performed in the associated transmitter. 1 2 OPL 3 A m 8 A R 7 6 2 5 4 1 Absorption measurement with reference 1 Light source 2 Optical windows 3 Measurement filter 4 Measuring detector 5 Lens 6 Medium flow 7 Reference filter 8 Reference detector A0029412 Measuring system An optical measuring system comprises: Sensor (photometer) Liquiline CM44P transmitter Cable set CUK80 Assembly to suit the sensor, e.g. OUA260 2 Endress+Hauser

1 2 7 3 6 5 4 2 Example of a measuring system with a photometer sensor 1 pipe 5 Flow assembly OUA260 2 Transmitter CM44P 6 Sensor: light source (lamp) 3 Cable set CUK80 7 Cable set CUK80 4 Sensor: detector Input Measured variable Measuring range Wavelength UV absorption 0 to 2.5 AU Max. 50 OD (depending on the optical path length) Discrete wavelength at 254, 280, 295, 302, 313 or 365 nm More available on request Power supply Electrical connection The sensor is connected to the transmitter using the pre-terminated or labeled cable set CUK80 (for connection to CM44P) or OUK40 (for connection to CVM40). The terminals and labeling may vary depending on the transmitter in use. The cable set must be ordered separately. Endress+Hauser 3

YE YE A B GY RD WH GN GY B 3 connecting cable A Light source (lamp) power supply B Signals of measurement and reference detector A0028385 CM44P terminal CVM40 terminal Cable color Assignment P+ V1.1 YE (thick) Lamp voltage + S+ V1.3 YE (thin) Detection of lamp voltage + P- V1.2 (thick) Lamp voltage - S- V1.4 (thin) Detection of lamp voltage - A (1) S1.1 RD Measuring detector sensor + C(1) S1.2 Measuring detector sensor - SH (1) S1.S GY Shield A (2) S2.1 WH Sensor reference + C(2) S2.2 GN Sensor reference - SH (2) S2.S GY Shield Cable length Maximum 100 m (330 ft) Lamp voltage Sensor version Lamp type Lamp voltage [V] -xxxx Dual beam, low-pressure mercury lamp 11.9 ± 0.1 Versions for use in hazardous areas Safety instructions for electrical apparatus in explosion-hazardous areas, XA01403C Connecting the detector using a safety barrier The photometer sensors use silicon photovoltaic cells as detectors which are operated in the current mode. The detectors are intrinsically safe and can be deployed in Zone 1 environments. The safe area is separated from the hazardous area by one safety barrier MTL7760AC. 4 Endress+Hauser

90 (3.54) 105 (4.13) 12.6 (0.5) 4 Safety barrier, dimensions in mm (inch) The safety barrier may only have a very low leak current since the optical signals from the sensor can be in the nanoampere range. Therefore, the sensor cable shield is connected to the ground terminal of the barrier. On delivery, the CUK80 detector cable is permanently wired to the safety barrier. All you have to do is simply connect the individual cable ends to the detector and transmitter. Photometer (Det.) MTL7760ac CM44P RD 3 4 GY 1 2 RD GY C (1) A (1) SH (1) Connecting the hazardous area lamp using a junction box The hazardous area lamp (EXP-1) must be connected to the transmitter using a certified junction box. For versions with FM approval, the junction box is included in the delivery and already preterminated on the lamp side. You simply have to connect the cable of the transmitter (CUK80) to the terminals of the junction box. For versions with ATEX approval, the junction box is not included in the delivery and it and the cable glands required must be provided by the customer at the place of installation. You must connect the cables entirely on your own (CUK80 of transmitter and lamp cable of photometer sensor). Endress+Hauser 5

EXP 1 ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D 3 4 PE YE YE WH GN GY CM44P P+ S+ S- P- A (2) C (2) SH (2) 27 30 5 Connecting the hazardous area lamp to CM44P using a junction box A0029441 Installation Installation instructions A D B E C 6 Mounting angles. The arrows indicate the direction of medium flow in the pipe. A Preferred mounting angle B Optimum mounting angle C Acceptable mounting angle D Mounting angle to be avoided E Forbidden mounting angle A0028250 6 Endress+Hauser

Environment Ambient temperature range Storage temperature 0 to 55 C (32 to 130 F) -10 to +70 C (+10 to +160 F) Humidity 5 to 95 % Degree of protection IP 65 (NEMA 4) for all optical parts Process Process temperature Process pressure 0 to 90 C (32 to 194 F) continuous Max. 130 C (266 F) for 2 hours Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly Mechanical construction Design, dimensions C A B 7 Sensor module A Dimension of lamp, depends on lamp type, see table B Dimension of detector, see table C Assembly, see Technical Information for assembly A0028305 Lamp type Dimension A in mm (inch) Standard lamp 142 (5.60) Detector type Dimension B in mm (inch) Standard with reference rod 60.2 (2.37) Easycal 69 (2.70) The total length of the sensor module is derived from the lengths of the lamp, the detector and the assembly. The dimensions of the OUA260 assembly are provided in Technical Information, TI00418C. When connecting the sensor cable, make sure you maintain an additional distance of 5 cm (2") on both the lamp side and the detector side of the sensor. Endress+Hauser 7

Weight Sensor UV lamp UV lamp with wire-braided cable (1.2 m (4 ft)) and junction box (sensor for hazardous area) Easycal detector Standard detector OUA260 assembly TC ¼" TC 1" TC 2" TC 4" 0.58 kg (1.28 lbs) 3.2 kg (6.66 lbs) 0.65 kg (1.43 lbs) 0.36 kg (0.794 lbs) 1.14 kg (2.51 lbs) 1.39 kg (3.07 lbs) 1.88 kg (4.15 lbs) 3.38 kg (7.45 lbs) Materials Sensor housing Stainless steel 316 OUA260 assembly Cable connection ends Stainless steel 316, 316L or Kynar or customer-specific material Depends on version Nickel-plated brass Light source Pre-set, low-pressure mercury lamp Lamp operating life: typically 3000 h, at least 1000 h Detector UV silicon detectors, hermetically sealed Filter Multilayer interference filter, designed for extreme UV conditions Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D FDA conformity All non-metal parts in contact with medium, such as rubber and plastic parts, meet the requirements of FDA 21 CFR 177.2600. The plastic and elastomer parts of the sensor in contact with medium have passed the biological reactivity tests according to USP <87> and <88> Class VI. Ordering information Product page www.endress.com/ousaf44 Product Configurator On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 8 Endress+Hauser

3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. Scope of delivery The scope of delivery consists of the following depending on the version ordered: sensor Detector and lamp module without flow assembly or Detector and lamp module mounted on OUA260 flow assembly Operating Instructions If the sensor is ordered with a transmitter, the complete measuring system is factory-calibrated and shipped as one package. If you have any questions, please contact your supplier or your local sales center. Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Flow assembly OUA260 Flow assembly for hygienic sensors For sensor installation in pipes Materials: stainless steel 316, 316L or Kynar (other materials available on request) Wide variety of process connections and path lengths available Product Configurator on the product page: www.endress.com/oua260 Technical Information TI00418C Cable Calibration CUK80 cable set Pre-terminated and labeled cables for connecting analog photometer sensors Product Configurator on the product page: www.endress.com/cuk80 EasyCal retrofit kit Patented system traceable to NIST for the online calibration of UV absorption sensors Order numbers: 254 nm: 71210149 280 nm: 71210150 295 nm: 71210156 302 nm: 71210153 313 nm: 71210151 365 nm: 71210152 Reference rod Order number: 71108543 Endress+Hauser 9

www.addresses.endress.com