Product Brief for Alarm Analytics V9.3 October 2013

Similar documents
Product Brief for Alarm Analytics V9.2 April 2010

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Introduction. Introduction

Exaquantum/ARA Alarm Reporting and Analysis

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

DON T JUST REPORT ON ALARMS, TAKE

PM-ANALYZE. Overview 1. System Configuration 2. Operation 3. Analysis of Alarms and process values. User Interface 4

VTScadaLIGHT for Small Water & Wastewater Systems

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Supervisor Standard Edition

Getting Started with Live Exceptions

Platform Services BACnet Alarm Management

L automazione al servizio della manutenzione

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

Monitor Alarms and Events

GMS GRAPHICAL MANAGEMENT SYSTEM

DynAMo Alarm & Operations Management

AC2000 Security Hub Security and Event Management System

Avigilon Control Center 5 System Integration Guide

Patriot Systems Limited

Oracle Communications Performance Intelligence Center

Intelligent alarm management

KEY FEATURES EASY ACCESS. Through web browser for both clients and administrators CLIENT MONITORING. Not dependent on access to site network

Samsung SDS BMS Ver.2.0. Technical Specification

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

Advanced Facility Air-Management Technology

Remote fiber testing to improve SLA s

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Patriot Systems Limited

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Monitoring Operator Guide. Access Control Manager Software Version

Alarm System Performance Metrics

Complexity made simple

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

ABB Ability System 800xA Alarm Management

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

Itron Water Loss Management Solutions. Advanced Digital Leak Detection Overview Session

MultiSite Monitor. Get the full performance picture from all your sites

D-Link Central Management System

Avigilon Control Center System Integration Guide

ANTIK Smart Home scheme. 2

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

Alarm Benchmark Module By Konnection Introduction Overview Description

Customized, End-to-End Facility Monitoring

2012 Honeywell Pacific Users Group. Sus tain.ability.

Experion LX Direct Station Specification

Facility Commander Complete, Integrated Command and Control

ABLOY REMOTE. Intelligent high security with wire-free key control. An ASSA ABLOY Group brand

Compact HMI Overview

WHITE PAPER FEBRUARY Oracle Retail: Optimize Performance and Reduce Business Risk

HikCentral Web Client. User Manual

Complete Security Solution

Recording Server PRELOADED

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Compact Product Suite Compact HMI 6.0 Overview ABB

ThermoControl 0 C - 10 C - 20 C - 30 C

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Oracle Communications Performance Intelligence Center

Datasheet Face Recognition [Genetec VMS]

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Datasheet Video Based Fire & Smoke Detection

REMOTE MONITORING AND ALARM SYSTEM

Home center 2.7 Windows client Installation guide

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

L automazione al servizio della manutenzione nell industria di processo

OnGuard 7.2 Resolved Issues

Intelligent Keys. A smart solution for recurring revenue

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

NGC-20 LOCAL CONTROL CENTRAL MONITORING

HikCentral Web Client. User Manual

FALCO Access Control. Product Training

Using ANM Mobile CHAPTER

DATAssure. Laboratory wireless alarm & monitoring system

UD-VMS510i. Surveillance Management Center

Architectural and Engineering Specification for a Security Management System. StarNet 2

Ovation Alarm Management System

Dr. Pete Gábor Vodafone Hungary. NB-IoT (Narrow Band Internet of Things)

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Before you install ProSeries Express Edition software for network use

Managing Network Alarms and Events

Architecting a Distributed FactoryTalk View SE Application

Access CONTROL. MANAGEMENT Software

The Top 10 Worst Performing Alarm Systems in Industry

Making the Most of Alarms

Daily Offsite; 30 days of backup available; Offsite Annual backup maintained for 5 years

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Simplex Panel Interface Guide

Universal Tag Locator. Operations management software for process facilities

Contamination Control for Electronic and Semiconductor Applications

GasGard 100 Control System

OnGuard 7.1 Resolved Issues

Transcription:

Product Brief for Alarm Analytics V9.3 October 2013

Alarm Analytics V9.3 Product Brief October 2013 Complies with industry standards EEMUA 191 and OSHA PSM 1910.119 for Alarm Analytics, connects to all major databases ICONICS Alarm Analytics product enables plant personnel to Visualize, Analyze, and Manage alarm information in accordance with the industry best practices. The push for operational excellence in the manufacturing industry is driving the need for more effective alarm analytics. Proper analysis of alarms and events in a manufacturing plant can reveal significant opportunities for improving current operations and mitigating abnormal situations. BizViz Alarm Analytics captures and analyzes all alarm and event information to identify frequent alarms, chattering alarms, cross-correlated alarms, and many more alarm-related issues. This module also records, analyzes, and displays operator-initiated process changes, which then yield significant insight into the performance of the entire system. Features Benefits Store Alarms and Events to popular databases Captures and archives alarms, operator actions, and system events into SQL, Oracle, Access or MSDE. Analyze Alarms in real-time or by a specified time period Identifies unusual alarm occurrences, trends in plant alarms and control modules responsible for those alarms Benchmark alarm performance Benchmarks alarms vs. established standard EEMUA 191 recommended best practices. Deliver alarm information in industry Complies with standards set by OSHA PSM 1910.119. standard reports Leverage Microsoft Excel expertise Alarm Analytics is built on top of widely used Microsoft Excel Real-time Alarm Analytics drives Alarm Analytics provides up-to-the-minute reports that better process understanding show alarm frequency, statistics, user acknowledgements, alarm priority distributions or system events. Easy configuration with industry Predefined reports and wizards help focus on a plant standard predefined reports area, time period or event type. Identify areas for improvement Built-in Pareto charts to help rank alarms by frequency and categorize problematic areas such as tag chattering. Distribute Alarm Analytics reports via e-mail or fax Users can view reports in Excel, PDF, or HTML format on the Web or receive them via automated e-mail. Simplifies Incident Investigation Easily access all recorded events and operator actions. ICONICS 2013 Product Brief for Alarm Analytics V9.3 1

Alarm Analytics: Industry Standard-based Alarm Reporting Alarm Analytics, which is based on ICONICS BizViz ReportWorX and AlarmWorX32 Alarm Logger, provides advanced Alarm Analytics, Alarm Reporting, and Alarm Management. Alarm Analytics supports industry standards for Alarm Management issued by OSHA and EEMUA. The Alarm Analytics module contains 15 standard reports with advanced Alarm KPIs, including the following: 1. Alarm Distribution by Interval 2. Alarm Distribution by Interval with Priority 3. Alarm Distribution by Priority 4. Alarm Rate Distribution by Interval 5. Alarm Tag Chattering 6. Alarm Tag Frequency 7. Alarms from Worst Actors by Interval 8. Average Alarm Rate per Minor/Major Interval 9. Cross-Correlation Analysis 10. Operator Changes by Interval 11. Operator Response Time 12. Peak Alarm Rate Distribution 13. Standing Alarms at Time 14. Standing Alarms by Interval 15. Standing Alarms Duration Pre-Configured Templates Alarm Distribution by Interval This report provides a quick insight into the frequency of alarms over a specified interval. It shows an alarm transaction count per interval over a time range. The user specifies the time interval such as daily, weekly, or monthly and the report automatically adjusts the chart with the new interval values. In addition, the alarms can be separated out by priority according to priority levels that you can customize to match the standards at your facility. The color coding corresponds to alarm priority levels, which by default match the EEMUA standards for critical, high, medium and low. The Global Alarm Priority Manager allows the user to define the OPC Severity bands that correspond to their custom priorities if different from the EEMUA standards. ICONICS 2013 Product Brief for Alarm Analytics V9.3 2

Each alarm count bar adds up to 100% of the total count, showing the percent of alarms at each priority. Superimposed on the chart is the total number of transitions into alarm per interval in the form of a line chart. The Alarm Distribution by Interval with Priority chart integrates into Excel s PivotTable functionality for its data. Figure 1: Alarm Distribution by Interval Figure 2: Alarm Distribution by Interval with Priority Alarm Distribution by Priority If the distribution of the alarms by priority only is important the best visualization report is Alarm Distribution by Priority. This simple pie chart allows for a quick insight into how many alarms you are experiencing at each priority level. The priority levels are set to EEMUA standards by default (critical, high, medium and low) and can be customized easily with the Global Alarm Priority Manager. Figure 3: Alarm Distribution by Priority Alarm Tag Frequency Figure 4: Alarm Tag Frequency This report indicates which alarm tags went into alarm most often over a given period of time. The report uses a Pareto chart to sort the alarms by number of occurrences, so the worst alarm is the first one in the chart. The user can configure the maximum number of rows to return in the report, effectively turning it into a Top 10 or Top X Pareto chart. ICONICS 2013 Product Brief for Alarm Analytics V9.3 3

Alarm Tag Chattering This report is represented by a table that shows alarm tags that go in and out of alarm repeatedly in a short period of time (chattering). The user specifies a time window and the maximum number of rows. If an alarm repeats within the time window it is considered a chattering alarm and part of a cluster. For each tag, the table also includes the number of clusters, the average occurrences per cluster and the total number of occurrences. The table is sorted by the Cluster Member Percentage. The percentage of occurrences that happen in a cluster (Cluster Member Percentage) is calculated as follows: Figure 5: Alarm Tag Chattering Cluster Member Percentage = (Avg. occurrences per cluster) * (# of clusters) / (total occurrences) Cross Correlation Analysis This analysis finds alarms that always (or usually) occur one after another which suggests correlation between two alarms. This process compares all combinations of pairs of alarm tags and the results for each alarm pair are shown in tabular format. The table shows the following important information: Occurrence Count The number of times the child tag occurred after the primary tag, within the time window. Predictability The percentage of time that the primary alarm occurred and the child alarm occurred within the time window i.e. 100% if the child alarm occurred every time the primary alarm occurred. Figure 6: Cross Correlation Significance The percentage of time the child alarm occurs within the window of the primary, i.e. 100% if the child alarm only occurs after the primary alarm within the time window. ICONICS 2013 Product Brief for Alarm Analytics V9.3 4

Operator Response Time and Operator Changes by Interval This report analyzes the time it takes an operator to respond to each alarm condition (Acknowledge, or ACK for short) and the time for the condition to Return to Normal (RTN). Since each row summarizes multiple occurrences, the Min, Max and Average values are shown. The table is sorted in descending order according to whatever the user selects while executing the report. The Operator Changes report by interval shows operator actions as defined in OPC Tracking event in GenEvent audit tracking system. Figure 7: Operator Response Time Standing Alarms at Time, by Interval and Duration Standing alarms are the ones that show up on the AlarmWorX32 viewer (i.e. active and/or unacknowledged alarms). A snapshot of the number of standing alarms is captured at the end of each interval and is displayed on a bar chart. The related reports include Standing Alarms at Time and Standing Alarm Duration. Figure 8: Standing Alarms by Interval ICONICS 2013 Product Brief for Alarm Analytics V9.3 5

Configuring Alarm Analytics Figure 9: Report Configurator Alarm Analytics users can now visualize all of their configured data sources in one centralized location and edit them through simple property dialogs. This leads to much better performance when loading and editing your reports. Another revolutionary new feature is the Layout Manager. By far the most noticeable difference for our users will be the ease with which they can now configure many cells for data. Hundreds of OPC tags can be added to a report in just seconds! Figure 10: Layout Manager Unified Web Interface Alarm Analytics leverages the power of the Unified Web Interface for V9.3, which allows users to visualize, execute, and manage their reports and transactions from any Webaccessible, thin-client browser. The Unified Web Interface is ideal for thin-client applications where access to the Alarm Analytics Server is restricted. Benefits of Unified Web Interface: Visualize reports with thinclient browser Execute and manage reports from central location Customize look and feel of your Web interface Sort and group reports for easier navigation Create Favorite folder Figure 11: Unified Web Interface ICONICS 2013 Product Brief for Alarm Analytics V9.3 6

System Requirements The BizViz Alarm Analytics product includes ReportWorX and AlarmWorX32 Logger and requires the following minimum hardware, software, and operating system components. System requirements may vary based on application size, system performance requirements, and loading factors. Microsoft Windows 2000 Professional or 2000 Server, or Windows XP Professional, or Windows Server 2003 MSDE 2000, SQL Server 2000, SQL Server Express, or SQL Server 2005 Microsoft.NET Framework 2.0 Microsoft Excel 2003 or greater Microsoft Internet Explorer 6.0 or greater Pentium 4 CPU, 2.0 GHz or greater At least 1 GB of available RAM Alarm Analytics Licensing Options Alarm Analytics comes in two configurations: Standard: Includes 15 industry standard Alarm Analytics pre-configured templates, ReportWorX - Standard Edition and AlarmWorX32 - Unlimited. Enterprise: Includes 15 industry standard Alarm Analytics pre-configured templates, ReportWorX - Enterprise Edition and AlarmWorX32 - Unlimited for the ability to create and run an unlimited number of custom, user defined, Alarm Analytics report. ICONICS 2013 Product Brief for Alarm Analytics V9.3 7

Founded in 1986, ICONICS is an award-winning independent software developer offering real-time visualization, HMI/SCADA, energy, fault detection, manufacturing intelligence, MES and a suite of analytics solutions for operational excellence. ICONICS solutions are installed in 70% of the Fortune 500 companies around the world, helping customers to be more profitable, agile and efficient, to improve quality and be more sustainable. ICONICS products are used in manufacturing, building automation, oil & gas, renewable energy, utilities, water/wastewater, pharmaceuticals, automotive and many other industries. ICONICS advanced visualization, productivity, and sustainability solutions are built on its flagship products: GENESIS64 HMI/SCADA, Hyper Historian plant historian, AnalytiX solution suite and MobileHMI mobile apps. Delivering information anytime, anywhere, ICONICS solutions scale from the smallest standalone embedded projects to the largest enterprise applications. ICONICS promotes an international culture of innovation, creativity and excellence in product design, development, technical support, training, sales and consulting services for end users, systems integrators, OEMs and Channel Partners. ICONICS has over 300,000 applications installed in multiple industries worldwide. World Headquarters 100 Foxborough Blvd. Foxborough, MA, USA, 02035 Tel: 508 543 8600 Email: us@iconics.com Web: www.iconics.com Czech Republic Tel: 420 377 183 420 Email: czech@iconics.com Italy Tel: 39 010 46 0626 Email: italy@iconics.com Germany Tel: 49 2241 16 508 0 Email: germany@iconics.com Netherlands Tel: 31 252 228 588 Email: holland@iconics.com France Tel: 33 4 50 19 11 80 Email: france@iconics.com UK Tel: 44 1384 246 700 Email: uk@iconics.com Australia Tel: 61 2 9605 1333 Email: australia@iconics.com China Tel: 86 10 8494 2570 Email: china@iconics.com India Tel: 91 22 67291029 Email: india@iconics.com www.iconics.com 2015 ICONICS, Inc. All rights reserved. Specifications are subject to change without notice. AnalytiX and its respective modules are registered trademarks of ICONICS, Inc. GENESIS64, GENESIS32, Hyper Historian, BizViz, PortalWorX, MobileHMI and their respective modules, OPC-To-The-Core, and Visualize Your Enterprise are trademarks of ICONICS, Inc. Other product and company names mentioned herein may be trademarks of their respective owners.