Technical Information OUSBT66

Similar documents
Technical Information OUSBT66

Technical Information OUSAF21

Technical Information OUSAF12

Technical Information OUSAF44

Technical Information OUSAF22

Technical Information OUSTF10

Technical Information OUSTF10

Condumax CLS16 and CLS16D

Operating Instructions OUSAF12

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Operating Instructions OUSTF10

Operating Instructions Indumax CLS54D

Specifications Wavelength Range: 190 nm to 800 nm continuous

Laser Distance Sensor Type M Analog-Output

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

Operating Instructions Condumax CLS15/16/21

Instruction Manual. optek-sensors AF56. optek-danulat GmbH Emscherbruchallee Essen

SECTION Fluorescent Dissolved Oxygen Measuring System

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

An FT-NIR Primer. NR800-A-006

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Turbimax CUE21 / CUE22

Features and Benefits

Portable central unit for several parameters

Features and Benefits

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

SECTION ph/orp Sensors

OMA-300 Process Analyzer

Challenges in industrial point sensing- NDIR John Saffell

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

sglux UV-SENSOR PROBES Catalogue

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

BENCHTOP FERMENTOR & BIOREACTOR SYSTEMS

MultiFix Central unit

Rinse connection adapter CPR 40

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Micro/Ultra Filtration System StamoClean CAT 430

Infrared Detectors. Special-Sensors for. Automation

Pyroelectric Infrared Sensor PIR

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

APPLIED. OMA-406R Rackmount Process Analyzer

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Exercise 1: IR Transmission and Reception

Turbimax CUE21 / CUE22

SPECTRAL INSTRUMENTATION

MultiFix Central unit

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

San Star Mixers. Versatile mixing solutions for cgmp applications in pharmaceutical, biotech, food and cosmetics

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

Effluent Monitoring. Solutions

SECTION Free/Available Chlorine Analysis System

CALIBRATION HOW IT WORKS

Chemical Processes in the Combustion

MARUTI ENGINEERING WORKS

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

CALIBRATION HOW IT WORKS

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

X56 Series Photometric Detectors

ZETA MAGNETIC AGITATORS

Air Resource Specialists, Inc.

2016 Catalogue. Bioreactor / Fermentor

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Benchtop System Overview

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Automation Technology for the Sugar Industry. ifm electronic -

818 Series Low-Power Detectors

Application Overview: SmartSwitch

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

BIOFLO /CELLIGEN 115 BENCHTOP FERMENTOR & BIOREACTOR VERSATILE L AUTOCLAVABLE SYSTEMS WITH EASY-TO-USE TOUCHSCREEN CONTROLS

Standard Specifications

PUV, PIR and PFO Series BROCHURE

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

ZETA Magnetic Agitators. For sterile liquid processing.

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

Understanding total measurement uncertainty in power meters and detectors

ProStar 325 UV-Vis Detector

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Table of Contents. 1. Mounting Tips... 2

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

Nexera-i Specifications Prominence-i Specifications

detectors UltiMate 3000 Variable Wavelength Detectors

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Electro Optical Components, Inc Skylane Boulevard, Suite D, Santa Rosa, CA Toll Free: 855-EOC

OPTISENS TUR 2000 Technical Datasheet

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Open-area Smoke Imaging Detector. Engineering Specification

Transcription:

TI00469C/07/EN/04.17 71396259 Products Solutions Services Technical Information NIR absorption sensor for the measurement of cell growth and biomass Application Cell growth in bacterial fermentation and applications in mammalian cell cultures Biomass in fermentation processes Monitoring of algae concentration Monitoring of crystallization processes Measurement of solids in: Your benefits Increased product yield thanks to fast and reliable absorption measurement in fermentation and crystallization applications Highest linearity and wide measuring range with LED lamp Suitable for pharmaceutical use: Stainless steel 1.4435 (AISI 316L) Sealless sapphire window without gaps High degree of product safety: Sterilizable and autoclavable CIP/SIP-resistant Cost-effective, time-efficient calibration with traceable plug-on filters For use in a wide range of applications: Variety of optical path lengths for different cell cultures and concentrations Process connection Pg 13.5 for installation in assemblies or head plates Suitable for lab-scale, pilot-scale and production-scale bioreactors Available in different lengths for different immersion depths

Function and system design Measuring principle Light absorption The measuring principle is based on the Lambert-Beer law. There is a linear dependency between the absorption of light and the concentration of the absorbing substance: A = -log(t) = ε. c. OPL T = I/I 0 T... Transmission I... Intensity of received light at detector I 0... Intensity of transmitted light of light source A... Absorption ε... Extinction coefficient c... Concentration OPL... Optical path length A light source emits radiation through the medium and the incident radiation is measured on the detector side. The intensity of the light is determined by a photodiode and converted to a photocurrent. The subsequent conversion to absorbance units (AU, OD) is performed in the associated transmitter. 1 OPL 2 3 2 5 4 1 Absorption measurement 1 Light source 2 Optical windows of the sensor 3 Detector 4 Measurement filter (depends on sensor, not provided on all sensors) 5 Medium flow A0029401 2 Endress+Hauser

Measuring system An optical measuring system comprises: sensor (photometer) Transmitter, for example Liquiline CM44P Sensor cable, for example CUK80 1 2 3 4 2 Example of a measuring system with a photometer sensor 1 Bioreactor (example) 2 sensor 3 CM44P transmitter 4 CUK80 sensor cable A0029711 Input Measured variable Measuring range Wavelength Optical path length NIR-absorption 0 to 4 AU 0 to 8 OD (depending on the optical path length) 880 nm 5, 10 or 20 mm Power supply Electrical connection The sensor is connected to the transmitter using the pre-terminated or labeled sensor fixed cable. Endress+Hauser 3

TP RD OG BN BN BK BK 3 Sensor cable A0029260 CM44P terminal CVM40 terminal Cable color Assignment P+ V1.1 BN Lamp voltage + S+ V1.3 BN Detection of lamp voltage + S- V1.4 BK Detection of lamp voltage - P- V1.2 BK Lamp voltage - A (1) S1.1 RD Sensor + C(1) S1.2 OG Sensor - SH (1) S1.S TP Shield Cable length Maximum 20 m (65 ft) Lamp voltage Sensor version Lamp type Lamp voltage [V] -xxxxx LED 7.5 ± 0.1 Installation Installation instructions The sensor can be installed up to the horizontal in an assembly, support or suitable process connection. Other angles of inclination are not recommended. 4 Permitted mounting angle A0029251 4 Endress+Hauser

Mounting in pipes Detail A 5 3 Detail A 90 3 2 1 4 5 2 5 Permitted and unacceptable installation positions in pipes A0029258 Comply with the following conditions. Otherwise you run the risk of damaging the measuring point or obtaining incorrect measured values. The diameter of the pipe must be at least 50 mm (2"). Install the sensor in places with consistent flow conditions. The best installation location is in the ascending pipe (item 1). Installation in the horizontal pipe (item 5) is also possible. Do not install the sensor in places where air pockets or bubbles occur ( 5, item 3) or where sedimentation may occur (item 2). Avoid installation in the down pipe (item 4). Align the sensor in such a way that the medium flows through the measuring gap (self-cleaning effect). Environment Ambient temperature Storage temperature 0 to 55 C (32 to 130 F) 0 to 70 C (32 to 160 F) Humidity 5 to 95 % Degree of protection IP 68, Fischer connector (up to 2 m (6.6 ft) water column for 24 h) Process Process temperature Process pressure 0 to 90 C (32 to 194 F) continuous Max. 135 C (275 F) for 2 hours maximum Max. 10 bar (150 psi) absolute, at 90 C (194 F) Endress+Hauser 5

Mechanical construction Design, dimensions Ø 12 (0.47) Ø 20 (0.79) D A: 120 (4.72) B: 225 (8.86) C: 360 (14.17) 62 (2.44) 6 Dimensions in mm (inch) A Version with shaft length 120 mm (4.72") B Version with shaft length 225 mm (8.86") C Version with shaft length 360 mm (14.17") D Optical path length: 5, 10 or 20 mm A0029244 Weight Approx. 0.2 kg (0.44 lbs) Materials Sensor Stainless steel 1.4435 (316L) Window Sapphire Process connections Pg 13.5 Surface roughness Light source R a < 0.76 μm (30 μin) LED Ordering information Product page Product Configurator www.endress.com/ousbt66 On the product page there is a "Configure" button to the right of the product image Configure. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. Click the tab for this CAD and select the desired file type using picklists. Scope of delivery The scope of delivery consists of the following : sensor Operating Instructions Ordering the sensor together with a transmitter: If you select the calibration option in the Product Configurator for the transmitter, the complete measuring system (transmitter, sensor, cable) is factory-calibrated and shipped as one package. If you have any queries: Please contact your supplier or local sales center. 6 Endress+Hauser

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your Service or Sales Center. Assembly Unifit CPA442 Installation assembly for food, biotechnology and pharmaceutics With EHEDG and 3A certificate Product Configurator on the product page: www.endress.com/cpa442 Technical Information TI00306C Cleanfit CPA875 Retractable process assembly for sterile and hygienic applications For in-line measurement with standard 12 mm sensors for parameters such as ph, ORP and oxygen Product Configurator on the product page: www.endress.com/cpa875 Technical Information TI01168C Calibration calibration kit 2/0.35 AU Order no.: 71128340 Endress+Hauser 7

www.addresses.endress.com